-
1
-
-
0028909841
-
Epidemiology of trauma deaths: A reassessment
-
Sauaia A, Moore FA, Moore EE, et al. Epidemiology of trauma deaths: a reassessment. J Trauma. 1995;38:185-193.
-
(1995)
J Trauma
, vol.38
, pp. 185-193
-
-
Sauaia, A.1
Moore, F.A.2
Moore, E.E.3
-
3
-
-
15944366571
-
Hemorrhage control in the battlefield: Role of new hemostatic agents
-
Alam HB, Burris D, DaCorta JA, Rhee P. Hemorrhage control in the battlefield: Role of new hemostatic agents. Mil Med. 2005;170:63-69.
-
(2005)
Mil Med
, vol.170
, pp. 63-69
-
-
Alam, H.B.1
Burris, D.2
DaCorta, J.A.3
Rhee, P.4
-
4
-
-
1942421711
-
Controlling bleeding in the field: Hemostatic powders and dressings debut in the prehospital setting
-
Robinson K. Controlling bleeding in the field: hemostatic powders and dressings debut in the prehospital setting. J Emerg Nurs. 2004; 30:160-161.
-
(2004)
J Emerg Nurs
, vol.30
, pp. 160-161
-
-
Robinson, K.1
-
5
-
-
4344664437
-
Methods for improved hemorrhage control
-
Holcomb JB. Methods for improved hemorrhage control. Crit Care. 2004;8:S57-S60.
-
(2004)
Crit Care
, vol.8
-
-
Holcomb, J.B.1
-
6
-
-
16544369438
-
Hemostatic dressings for the first responder: A review
-
Neuffer MC, McDivitt J, Rose D, et al. Hemostatic dressings for the first responder: a review. Mil Med. 2004;169:716-720.
-
(2004)
Mil Med
, vol.169
, pp. 716-720
-
-
Neuffer, M.C.1
McDivitt, J.2
Rose, D.3
-
7
-
-
85026169465
-
Advanced hemostatic dressing development program: Animal model selection criteria and results of a study of nine hemostatic dressings in a model of severe large venous hemorrhage and hepatic injury in Swine
-
Pusateri AE, Modrow HE, Harris RA, et al. Advanced hemostatic dressing development program: animal model selection criteria and results of a study of nine hemostatic dressings in a model of severe large venous hemorrhage and hepatic injury in Swine. J Trauma. 2003;55:518-526.
-
(2003)
J Trauma
, vol.55
, pp. 518-526
-
-
Pusateri, A.E.1
Modrow, H.E.2
Harris, R.A.3
-
8
-
-
0037299544
-
Comparison of 10 different hemostatic dressings in an aortic injury
-
Sondeen JL, Pusateri AE, Coppes VG, Gaddy CE, Holcomb JB. Comparison of 10 different hemostatic dressings in an aortic injury. J Trauma. 2003;54:280-285.
-
(2003)
J Trauma
, vol.54
, pp. 280-285
-
-
Sondeen, J.L.1
Pusateri, A.E.2
Coppes, V.G.3
Gaddy, C.E.4
Holcomb, J.B.5
-
9
-
-
0037803489
-
Comparative analysis of hemostatic agents in a swine model of lethal groin injury
-
Alam HB, Uy GB, Miller D, et al. Comparative analysis of hemostatic agents in a swine model of lethal groin injury. J Trauma. 2003;54:1077-1082.
-
(2003)
J Trauma
, vol.54
, pp. 1077-1082
-
-
Alam, H.B.1
Uy, G.B.2
Miller, D.3
-
10
-
-
0028920586
-
Efficacy of a fibrin hemostatic bandage in controlling hemorrhage from experimental arterial injuries
-
Larson MJ, Bowersox JC, Lim RC, Jr., Hess JR. Efficacy of a fibrin hemostatic bandage in controlling hemorrhage from experimental arterial injuries. Arch Surg. 1995;130:420-422.
-
(1995)
Arch Surg
, vol.130
, pp. 420-422
-
-
Larson, M.J.1
Bowersox, J.C.2
Lim Jr., R.C.3
Hess, J.R.4
-
11
-
-
0030877569
-
Hemostatic efficacy of a fibrin sealant-based topical agent in a femoral artery injury model: A randomized, blinded, placebo-controlled study
-
Jackson MR, Friedman SA, Carter AJ, et al. Hemostatic efficacy of a fibrin sealant-based topical agent in a femoral artery injury model: a randomized, blinded, placebo-controlled study. J Vasc Surg. 1997; 26:274-280.
-
(1997)
J Vasc Surg
, vol.26
, pp. 274-280
-
-
Jackson, M.R.1
Friedman, S.A.2
Carter, A.J.3
-
12
-
-
0031983293
-
Efficacy of a dry fibrin sealant dressing for hemorrhage control after ballistic injury
-
Holcomb J, MacPhee M, Hetz S, Harris R, Pusateri A, Hess J. Efficacy of a dry fibrin sealant dressing for hemorrhage control after ballistic injury. Arch Surg. 1998;133:32-35.
-
(1998)
Arch Surg
, vol.133
, pp. 32-35
-
-
Holcomb, J.1
MacPhee, M.2
Hetz, S.3
Harris, R.4
Pusateri, A.5
Hess, J.6
-
13
-
-
0032944682
-
Effect of dry fibrin sealant dressings versus gauze packing on blood loss in grade V liver injuries in resuscitated swine
-
Holcomb JB, Pusateri AE, Harris RA, et al. Effect of dry fibrin sealant dressings versus gauze packing on blood loss in grade V liver injuries in resuscitated swine. J Trauma. 1999;46:49-57.
-
(1999)
J Trauma
, vol.46
, pp. 49-57
-
-
Holcomb, J.B.1
Pusateri, A.E.2
Harris, R.A.3
-
14
-
-
0032793270
-
Dry fibrin sealant dressings reduce blood loss, resuscitation volume, and improve survival in hypothermic coagulopathic swine with grade V liver injuries
-
Holcomb JB, Pusateri AE, Harris RA, et al. Dry fibrin sealant dressings reduce blood loss, resuscitation volume, and improve survival in hypothermic coagulopathic swine with grade V liver injuries. J Trauma. 1999;47:233-240.
-
(1999)
J Trauma
, vol.47
, pp. 233-240
-
-
Holcomb, J.B.1
Pusateri, A.E.2
Harris, R.A.3
-
15
-
-
0035102924
-
Effect of fibrin bandage fibrinogen concentration on blood loss after grade V liver injury in swine
-
Pusateri AE, Holcomb JB, Harris RA, et al. Effect of fibrin bandage fibrinogen concentration on blood loss after grade V liver injury in swine. Mil Med. 2001;166:217-222.
-
(2001)
Mil Med
, vol.166
, pp. 217-222
-
-
Pusateri, A.E.1
Holcomb, J.B.2
Harris, R.A.3
-
16
-
-
3042850440
-
Structural design of the dry fibrin sealant dressing and its impact on the hemostatic efficacy of the product
-
Pusateri AE, Kheirabadi BS, Delgado AV, et al. Structural design of the dry fibrin sealant dressing and its impact on the hemostatic efficacy of the product. J Biomed Mater Res. 2004;70B:114-121.
-
(2004)
J Biomed Mater Res
, vol.70 B
, pp. 114-121
-
-
Pusateri, A.E.1
Kheirabadi, B.S.2
Delgado, A.V.3
-
17
-
-
0035137590
-
Treatment of grade 4 renal stab wounds with absorbable fibrin adhesive bandage in a porcine model
-
Morey AF, Anema JG, Harris R, et al. Treatment of grade 4 renal stab wounds with absorbable fibrin adhesive bandage in a porcine model. J Urol. 2001;165:955-958.
-
(2001)
J Urol
, vol.165
, pp. 955-958
-
-
Morey, A.F.1
Anema, J.G.2
Harris, R.3
-
18
-
-
24644458324
-
Hemostatic efficacy of two advanced dressings in an aortic hemorrhage model in swine
-
Kheirabadi BS, Acheson EM, Deguzman R, et al. Hemostatic efficacy of two advanced dressings in an aortic hemorrhage model in swine. J Trauma. 2005;59:25-34.
-
(2005)
J Trauma
, vol.59
, pp. 25-34
-
-
Kheirabadi, B.S.1
Acheson, E.M.2
Deguzman, R.3
-
19
-
-
30044437888
-
Comparison of hemorrhage control agents applied to lethal extremity arterial hemorrhage in swine
-
Acheson EM, Kheirabadi BS, Deguzman R, Dick EJ Jr., Holcomb JB. Comparison of hemorrhage control agents applied to lethal extremity arterial hemorrhage in swine. J Trauma. 2005;59:865-874.
-
(2005)
J Trauma
, vol.59
, pp. 865-874
-
-
Acheson, E.M.1
Kheirabadi, B.S.2
Deguzman, R.3
Dick Jr., E.J.4
Holcomb, J.B.5
-
20
-
-
0032828986
-
Intraoperative use of the absorbable fibrin adhesive bandage: Long term effects
-
Cornum R, Bell J, Gresham V, Brinkley W, Beall D, MacPhee M. Intraoperative use of the absorbable fibrin adhesive bandage: long term effects. J Urol. 1999;162:1817-1820.
-
(1999)
J Urol
, vol.162
, pp. 1817-1820
-
-
Cornum, R.1
Bell, J.2
Gresham, V.3
Brinkley, W.4
Beall, D.5
MacPhee, M.6
-
21
-
-
0030833290
-
Implications of new dry fibrin sealant technology for trauma surgery
-
Holcomb JB, Pusateri AE, Hess JR, et al. Implications of new dry fibrin sealant technology for trauma surgery. Surg Clin North Am. 1997;77:943-952.
-
(1997)
Surg Clin North Am
, vol.77
, pp. 943-952
-
-
Holcomb, J.B.1
Pusateri, A.E.2
Hess, J.R.3
-
22
-
-
0034029856
-
Comparison of poly-N-acetyl glucosamine (P-GlcNAc) with absorbable collagen (Actifoam), and fibrin sealant (Bolheal) for achieving hemostasis in a swine model of splenic hemorrhage
-
Chan MW, Schwaitzberg SD, Demcheva M, et al. Comparison of poly-N-acetyl glucosamine (P-GlcNAc) with absorbable collagen (Actifoam), and fibrin sealant (Bolheal) for achieving hemostasis in a swine model of splenic hemorrhage. J Trauma. 2000;48:454-457.
-
(2000)
J Trauma
, vol.48
, pp. 454-457
-
-
Chan, M.W.1
Schwaitzberg, S.D.2
Demcheva, M.3
-
23
-
-
0037243875
-
Effect of a chitosan-based hemostatic dressing on blood loss and survival in a model of severe venous hemorrhage and hepatic injury in swine
-
Pusateri AE, McCarthy SJ, Gregory KW, et al. Effect of a chitosan-based hemostatic dressing on blood loss and survival in a model of severe venous hemorrhage and hepatic injury in swine. J Trauma. 2003;54:177-182.
-
(2003)
J Trauma
, vol.54
, pp. 177-182
-
-
Pusateri, A.E.1
McCarthy, S.J.2
Gregory, K.W.3
-
24
-
-
4043049404
-
Mechanisms of poly-N-acetyl glucosamine polymer-mediated hemostasis: Platelet interactions
-
Thatte HS, Zagarins S, Khuri SF, Fischer TH. Mechanisms of poly-N-acetyl glucosamine polymer-mediated hemostasis: platelet interactions. J Trauma. 2004;57:S13-S21.
-
(2004)
J Trauma
, vol.57
-
-
Thatte, H.S.1
Zagarins, S.2
Khuri, S.F.3
Fischer, T.H.4
-
26
-
-
4043092049
-
Hemostasis in the absence of clotting factors
-
Favuzza J, Hechtman HB. Hemostasis in the absence of clotting factors. J Trauma. 2004;57:S42-S44.
-
(2004)
J Trauma
, vol.57
-
-
Favuzza, J.1
Hechtman, H.B.2
-
27
-
-
4043117617
-
In vitro effects of poly-N-acetyl glucosamine on the activation of platelets in platelet-rich plasma with and without red blood cells
-
Valeri CR, Srey R, Tilahun D, Ragno G. In vitro effects of poly-N-acetyl glucosamine on the activation of platelets in platelet-rich plasma with and without red blood cells. J Trauma. 2004;57:S22-S25.
-
(2004)
J Trauma
, vol.57
-
-
Valeri, C.R.1
Srey, R.2
Tilahun, D.3
Ragno, G.4
-
28
-
-
4043131636
-
Comparison of poly-N-acetyl glucosamine with commercially available topical hemostats for achieving hemostasis in coagulopathic models of splenic hemorrhage
-
Schwaitzberg SD, Chan MW, Cole DJ, et al. Comparison of poly-N-acetyl glucosamine with commercially available topical hemostats for achieving hemostasis in coagulopathic models of splenic hemorrhage. J Trauma. 2004;57:S29-S32.
-
(2004)
J Trauma
, vol.57
-
-
Schwaitzberg, S.D.1
Chan, M.W.2
Cole, D.J.3
-
29
-
-
0032828610
-
A pilot study evaluating the efficacy of a fully acetylated poly-N-acetyl glucosamine membrane formulation as a topical hemostatic agent
-
Cole DJ, Connolly RJ, Chan MW, Schwaitzberg SD, Byrne TK, Adams DB, et al. A pilot study evaluating the efficacy of a fully acetylated poly-N-acetyl glucosamine membrane formulation as a topical hemostatic agent. Surgery. 1999;126:510-517.
-
(1999)
Surgery
, vol.126
, pp. 510-517
-
-
Cole, D.J.1
Connolly, R.J.2
Chan, M.W.3
Schwaitzberg, S.D.4
Byrne, T.K.5
Adams, D.B.6
-
30
-
-
7244234579
-
Modified rapid deployment hemostat bandage terminates bleeding in coagulopathic patients with severe visceral injuries
-
King DR, Cohn SM, Proctor KG. Modified rapid deployment hemostat bandage terminates bleeding in coagulopathic patients with severe visceral injuries. J Trauma. 2004;57:756-759.
-
(2004)
J Trauma
, vol.57
, pp. 756-759
-
-
King, D.R.1
Cohn, S.M.2
Proctor, K.G.3
-
31
-
-
4043158428
-
Application of the poly-N-acetyl glucosamine-derived rapid deployment hemostat trauma dressing in severe/lethal Swine hemorrhage trauma models
-
Connolly RJ. Application of the poly-N-acetyl glucosamine-derived rapid deployment hemostat trauma dressing in severe/lethal Swine hemorrhage trauma models. J Trauma. 2004;57:S26-S28.
-
(2004)
J Trauma
, vol.57
-
-
Connolly, R.J.1
-
32
-
-
0043237350
-
The RDH bandage: Hemostasis and survival in a lethal aortotomy hemorrhage model
-
Vournakis JN, Demcheva M, Whitson AB, Finkielsztein S, Connolly RJ. The RDH bandage: hemostasis and survival in a lethal aortotomy hemorrhage model. J Surg Res. 2003;113:1-5.
-
(2003)
J Surg Res
, vol.113
, pp. 1-5
-
-
Vournakis, J.N.1
Demcheva, M.2
Whitson, A.B.3
Finkielsztein, S.4
Connolly, R.J.5
-
33
-
-
0042821712
-
Modified rapid deployment hemostat bandage reduces blood loss and mortality in coagulopathic pigs with severe liver injury
-
Jewelewicz DD, Cohn SM, Crookes BA, Proctor KG. Modified rapid deployment hemostat bandage reduces blood loss and mortality in coagulopathic pigs with severe liver injury. J Trauma. 2003; 55:275-280.
-
(2003)
J Trauma
, vol.55
, pp. 275-280
-
-
Jewelewicz, D.D.1
Cohn, S.M.2
Crookes, B.A.3
Proctor, K.G.4
-
34
-
-
2942705909
-
Application of a zeolite hemostatic agent achieves 100% survival in a lethal model of complex groin injury in Swine
-
Alam HB, Chen Z, Jaskille A, et al. Application of a zeolite hemostatic agent achieves 100% survival in a lethal model of complex groin injury in Swine. J Trauma. 2004;56:974-983.
-
(2004)
J Trauma
, vol.56
, pp. 974-983
-
-
Alam, H.B.1
Chen, Z.2
Jaskille, A.3
-
35
-
-
33645549194
-
A Special Report on the chitosan-based hemostatic dressing: Experience in current combat operations
-
Wedmore I, McManus JG, Pusateri AE, Holcomb JB. A Special Report on the chitosan-based hemostatic dressing: Experience in current combat operations. J Trauma. 2006;60:655-658.
-
(2006)
J Trauma
, vol.60
, pp. 655-658
-
-
Wedmore, I.1
McManus, J.G.2
Pusateri, A.E.3
Holcomb, J.B.4
-
36
-
-
4744341799
-
Application of a granular mineral-based hemostatic agent (QuikClot) to reduce blood loss after grade V liver injury in swine
-
Pusateri AE, Delgado AV, Dick EJ Jr., et al.. Application of a granular mineral-based hemostatic agent (QuikClot) to reduce blood loss after grade V liver injury in swine. J Trauma. 2004;57:555-562.
-
(2004)
J Trauma
, vol.57
, pp. 555-562
-
-
Pusateri, A.E.1
Delgado, A.V.2
Dick Jr., E.J.3
-
37
-
-
4444363225
-
Thermal injury resulting from application of a granular mineral hemostatic agent
-
Wright JK, Kalns J, Wolf EA, et al. Thermal injury resulting from application of a granular mineral hemostatic agent. J Trauma. 2004; 57:224-230.
-
(2004)
J Trauma
, vol.57
, pp. 224-230
-
-
Wright, J.K.1
Kalns, J.2
Wolf, E.A.3
-
38
-
-
0842343476
-
Intracorporeal use of the hemostatic agent QuickClot in a coagulopathic patient with combined thoracoabdominal penetrating trauma
-
Wright FL, Hua HT, Velmahos G, et al. Intracorporeal use of the hemostatic agent QuickClot in a coagulopathic patient with combined thoracoabdominal penetrating trauma. J Trauma. 2004; 56:205-208.
-
(2004)
J Trauma
, vol.56
, pp. 205-208
-
-
Wright, F.L.1
Hua, H.T.2
Velmahos, G.3
-
39
-
-
0034572907
-
An alternative pathway for preclinical research in fluid management
-
Sibbald WJ. An alternative pathway for preclinical research in fluid management. Crit Care. 2000;4:S8-S15.
-
(2000)
Crit Care
, vol.4
-
-
Sibbald, W.J.1
|