메뉴 건너뛰기




Volumn 86, Issue 2, 2015, Pages 201-207

Comparison of planned and achieved implant position in total knee arthroplasty with patient-specific positioning guides

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; AGED; ARTICLE; CLINICAL ARTICLE; COMPUTER ASSISTED TOMOGRAPHY; COMPUTER PROGRAM; FEMALE; HUMAN; KNEE RADIOGRAPHY; MALE; NUCLEAR MAGNETIC RESONANCE IMAGING; POSTOPERATIVE PERIOD; ROTATING HINGE KNEE PROSTHESIS; SURGICAL TECHNIQUE; TOTAL KNEE REPLACEMENT; ANIMAL; COHORT ANALYSIS; COMPARATIVE STUDY; COMPUTER ASSISTED SURGERY; KNEE; KNEE ARTHROPLASTY; KNEE PROSTHESIS; MIDDLE AGED; PREOPERATIVE CARE; PROCEDURES; RADIOGRAPHY; TREATMENT OUTCOME; VERY ELDERLY;

EID: 84925947299     PISSN: 17453674     EISSN: 17453682     Source Type: Journal    
DOI: 10.3109/17453674.2014.985154     Document Type: Article
Times cited : (15)

References (25)
  • 2
    • 0032418168 scopus 로고    scopus 로고
    • Malrotation causing patellofemoral complications after total knee arthroplasty
    • Berger R A, Crossett L S, Jacobs J J, Rubash H E. Malrotation causing patellofemoral complications after total knee arthroplasty. Clin Orthop Relat Res 1998; (356): 144-53.
    • (1998) Clin Orthop Relat Res , Issue.356 , pp. 144-153
    • Berger, R.A.1    Crossett, L.S.2    Jacobs, J.J.3    Rubash, H.E.4
  • 3
    • 84865313117 scopus 로고    scopus 로고
    • Preliminary experience with the patientspecific templating total knee arthroplasty
    • Boonen B, Schotanus M G, Kort N P. Preliminary experience with the patientspecific templating total knee arthroplasty. Acta Orthop 2012; 83 (4): 387- 93.
    • (2012) Acta Orthop , vol.83 , Issue.4 , pp. 387-393
    • Boonen, B.1    Schotanus, M.G.2    Kort, N.P.3
  • 4
    • 84874668905 scopus 로고    scopus 로고
    • A prospective randomised controlled study of patient-specific cutting guides compared with conventional instrumentation in total knee replacement
    • Chareancholvanich K, Narkbunnam R, Pornrattanamaneewong C. A prospective randomised controlled study of patient-specific cutting guides compared with conventional instrumentation in total knee replacement. Bone Joint J 2013; 95-B (3): 354-9.
    • (2013) Bone Joint J , vol.95-B , Issue.3 , pp. 354-359
    • Chareancholvanich, K.1    Narkbunnam, R.2    Pornrattanamaneewong, C.3
  • 6
    • 84892477015 scopus 로고    scopus 로고
    • The accuracy of component alignment in custom cutting blocks compared with conventional total knee arthroplasty instrumentation: Prospective control trial
    • Chotanaphuti T, Wangwittayakul V, Khuangsirikul S, Foojareonyos T. The accuracy of component alignment in custom cutting blocks compared with conventional total knee arthroplasty instrumentation: prospective control trial. Knee 2014; 21 (1): 185-8.
    • (2014) Knee , vol.21 , Issue.1 , pp. 185-188
    • Chotanaphuti, T.1    Wangwittayakul, V.2    Khuangsirikul, S.3    Foojareonyos, T.4
  • 7
    • 84898842627 scopus 로고    scopus 로고
    • A comparison of conventional and patient-specific instruments in total knee arthroplasty
    • Daniilidis K, Tibesku C O. A comparison of conventional and patient-specific instruments in total knee arthroplasty. Int Orthop 2014; 38 (3): 503-8.
    • (2014) Int Orthop , vol.38 , Issue.3 , pp. 503-508
    • Daniilidis, K.1    Tibesku, C.O.2
  • 8
    • 34147151141 scopus 로고    scopus 로고
    • Alignments and clinical results in conventional and navigated total knee arthroplasty
    • Ensini A, Catani F, Leardini A, Romagnoli M, Giannini S. Alignments and clinical results in conventional and navigated total knee arthroplasty. Clin Orthop Relat Res 2007; 457: 156-62.
    • (2007) Clin Orthop Relat Res , vol.457 , pp. 156-162
    • Ensini, A.1    Catani, F.2    Leardini, A.3    Romagnoli, M.4    Giannini, S.5
  • 9
    • 79957805832 scopus 로고    scopus 로고
    • Short-term outcome of 1,465 computer-navigated primary total knee replacements 2005- 2008
    • Gothesen O, Espehaug B, Havelin L, Petursson G, Furnes O. Short-term outcome of 1,465 computer-navigated primary total knee replacements 2005- 2008. Acta Orthop 2011; 82 (3): 293-300.
    • (2011) Acta Orthop , vol.82 , Issue.3 , pp. 293-300
    • Gothesen, O.1    Espehaug, B.2    Havelin, L.3    Petursson, G.4    Furnes, O.5
  • 10
    • 34249791470 scopus 로고    scopus 로고
    • Alignment and orientation of the components in total knee replacement with and without navigation support: A prospective, randomised study
    • Kim Y H, Kim J S, Yoon S H. Alignment and orientation of the components in total knee replacement with and without navigation support: a prospective, randomised study. J Bone Joint Surg Br 2007; 89 (4): 471-6.
    • (2007) J Bone Joint Surg Br , vol.89 , Issue.4 , pp. 471-476
    • Kim, Y.H.1    Kim, J.S.2    Yoon, S.H.3
  • 11
    • 84898596325 scopus 로고    scopus 로고
    • A comparison of alignment using patient specific guides, computer navigation and conventional instrumentation in total knee arthroplasty
    • Macdessi S J, Jang B, Harris I A, Wheatley E, Bryant C, Chen D B. A comparison of alignment using patient specific guides, computer navigation and conventional instrumentation in total knee arthroplasty. Knee 2014; 21 (2): 406-9.
    • (2014) Knee , vol.21 , Issue.2 , pp. 406-409
    • Macdessi, S.J.1    Jang, B.2    Harris, I.A.3    Wheatley, E.4    Bryant, C.5    Chen, D.B.6
  • 12
    • 0035379922 scopus 로고    scopus 로고
    • Effect of femoral and tibial component position on patellar tracking following total knee arthroplasty: 10-year follow-up of Miller-Galante i knees
    • Matsuda S, Miura H, Nagamine R, Urabe K, Hirata G, Iwamoto Y. Effect of femoral and tibial component position on patellar tracking following total knee arthroplasty: 10-year follow-up of Miller-Galante I knees. Am J Knee Surg 2001; 14 (3): 152-6.
    • (2001) Am J Knee Surg , vol.14 , Issue.3 , pp. 152-156
    • Matsuda, S.1    Miura, H.2    Nagamine, R.3    Urabe, K.4    Hirata, G.5    Iwamoto, Y.6
  • 14
    • 84878234059 scopus 로고    scopus 로고
    • Patient specific cutting guides versus an imageless, computer-assisted surgery system in total knee arthroplasty
    • Nam D, Maher P A, Rebolledo B J, Nawabi D H, McLawhorn A S, Pearle A D. Patient specific cutting guides versus an imageless, computer-assisted surgery system in total knee arthroplasty. Knee 2013; 20(4): 263-7.
    • (2013) Knee , vol.20 , Issue.4 , pp. 263-267
    • Nam, D.1    Maher, P.A.2    Rebolledo, B.J.3    Nawabi, D.H.4    McLawhorn, A.S.5    Pearle, A.D.6
  • 15
    • 84865102501 scopus 로고    scopus 로고
    • Improved accuracy of alignment with patient-specific positioning guides compared with manual instrumentation in TKA
    • Ng V Y, DeClaire J H, Berend K R, Gulick B C, Lombardi A V, Jr. Improved accuracy of alignment with patient-specific positioning guides compared with manual instrumentation in TKA. Clin Orthop Relat Res 2012; 470 (1): 99-107.
    • (2012) Clin Orthop Relat Res , vol.470 , Issue.1 , pp. 99-107
    • Ng, V.Y.1    Declaire, J.H.2    Berend, K.R.3    Gulick, B.C.4    Lombardi, A.V.5
  • 17
    • 4444354636 scopus 로고    scopus 로고
    • Navigation in total-knee arthroplasty: CT-based implantation compared with the conventional technique
    • Perlick L, Bathis H, Tingart M, Perlick C, Grifka J. Navigation in total-knee arthroplasty: CT-based implantation compared with the conventional technique. Acta Orthop Scand 2004; 75 (4): 464-70.
    • (2004) Acta Orthop Scand , vol.75 , Issue.4 , pp. 464-470
    • Perlick, L.1    Bathis, H.2    Tingart, M.3    Perlick, C.4    Grifka, J.5
  • 20
    • 26044441611 scopus 로고    scopus 로고
    • The variability of femoral rotational alignment in total knee arthroplasty
    • Siston R A, Patel J J, Goodman S B, Delp S L, Giori N J. The variability of femoral rotational alignment in total knee arthroplasty. J Bone Joint Surg Am 2005; 87 (10): 2276-80.
    • (2005) J Bone Joint Surg Am , vol.87 , Issue.10 , pp. 2276-2280
    • Siston, R.A.1    Patel, J.J.2    Goodman, S.B.3    Delp, S.L.4    Giori, N.J.5
  • 21
    • 84871613896 scopus 로고    scopus 로고
    • Patient-specific total knee arthroplasty required frequent surgeon-directed changes
    • Stronach B M, Pelt C E, Erickson J, Peters C L. Patient-specific total knee arthroplasty required frequent surgeon-directed changes. Clin Orthop Relat Res 2013; 471(1): 169-74.
    • (2013) Clin Orthop Relat Res , vol.471 , Issue.1 , pp. 169-174
    • Stronach, B.M.1    Pelt, C.E.2    Erickson, J.3    Peters, C.L.4
  • 22
    • 38149084127 scopus 로고    scopus 로고
    • Computerassisted total knee arthroplasty versus the conventional technique: How precise is navigation in clinical routine
    • Tingart M, Luring C, Bathis H, Beckmann J, Grifka J, Perlick L. Computerassisted total knee arthroplasty versus the conventional technique: how precise is navigation in clinical routine? Knee Surg Sports Traumatol Arthrosc 2008; 16 (1): 44-50.
    • (2008) Knee Surg Sports Traumatol Arthrosc , vol.16 , Issue.1 , pp. 44-50
    • Tingart, M.1    Luring, C.2    Bathis, H.3    Beckmann, J.4    Grifka, J.5    Perlick, L.6
  • 24
    • 84896345373 scopus 로고    scopus 로고
    • Component alignment during total knee arthroplasty with use of standard or custom instrumentation: A randomized clinical trial using computed tomography for postoperative alignment measurement
    • Woolson S T, Harris A H, Wagner D W, Giori N J. Component alignment during total knee arthroplasty with use of standard or custom instrumentation: a randomized clinical trial using computed tomography for postoperative alignment measurement. J Bone Joint Surg Am 2014; 96 (5): 366-72.
    • (2014) J Bone Joint Surg Am , vol.96 , Issue.5 , pp. 366-372
    • Woolson, S.T.1    Harris, A.H.2    Wagner, D.W.3    Giori, N.J.4
  • 25
    • 43349106247 scopus 로고    scopus 로고
    • Computer navigation did not improve alignment in a lower-volume total knee practice
    • Yau W P, Chiu K Y, Zuo J L, Tang W M, Ng T P. Computer navigation did not improve alignment in a lower-volume total knee practice. Clin Orthop Relat Res 2008; 466 (4): 935-45.
    • (2008) Clin Orthop Relat Res , vol.466 , Issue.4 , pp. 935-945
    • Yau, W.P.1    Chiu, K.Y.2    Zuo, J.L.3    Tang, W.M.4    Ng, T.P.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.