메뉴 건너뛰기




Volumn 21, Issue 1, 2014, Pages 185-188

The accuracy of component alignment in custom cutting blocks compared with conventional total knee arthroplasty instrumentation: Prospective control trial

Author keywords

Accuracy; Custom cutting blocks; Mechanical axis; Rotational axis; Total knee arthroplasty

Indexed keywords

HEMOGLOBIN;

EID: 84892477015     PISSN: 09680160     EISSN: 18735800     Source Type: Journal    
DOI: 10.1016/j.knee.2013.08.003     Document Type: Article
Times cited : (50)

References (35)
  • 3
    • 33847736288 scopus 로고    scopus 로고
    • Failure mechanisms after unicompartmental and tricompartmental primary knee replacement with cement
    • Furnes O., Espehaug B., Lie S.A., Vollset S.E., Engesaeter L.B., Havelin L.I. Failure mechanisms after unicompartmental and tricompartmental primary knee replacement with cement. J Bone Joint Surg 2007, 89:519-525.
    • (2007) J Bone Joint Surg , vol.89 , pp. 519-525
    • Furnes, O.1    Espehaug, B.2    Lie, S.A.3    Vollset, S.E.4    Engesaeter, L.B.5    Havelin, L.I.6
  • 4
    • 0029936939 scopus 로고    scopus 로고
    • Survivorship analysis of the Kinematic Stabilizer total knee replacement: a 10-to 14-year follow-up
    • Emmerson K.P., Moran C.G., Pinder I.M. Survivorship analysis of the Kinematic Stabilizer total knee replacement: a 10-to 14-year follow-up. J Bone Joint Surg Br 1996, 78-B:441-445.
    • (1996) J Bone Joint Surg Br , pp. 441-445
    • Emmerson, K.P.1    Moran, C.G.2    Pinder, I.M.3
  • 5
    • 0017353885 scopus 로고
    • Influence of positioning of prosthesis in total knee replacement
    • Lotke P.A., Ecker M.L. Influence of positioning of prosthesis in total knee replacement. J Bone Joint Surg 1977, 59:77-79.
    • (1977) J Bone Joint Surg , vol.59 , pp. 77-79
    • Lotke, P.A.1    Ecker, M.L.2
  • 6
    • 0023835093 scopus 로고
    • Mechanisms of failure in total knee arthroplasty
    • Moreland J.R. Mechanisms of failure in total knee arthroplasty. Clin Orthop Relat Res 1988, 266:49-64.
    • (1988) Clin Orthop Relat Res , vol.266 , pp. 49-64
    • Moreland, J.R.1
  • 7
    • 0027175876 scopus 로고
    • Long-term complications after total knee arthroplasty with or without resurfacing of the patella
    • Boyd A.D., Ewald F.C., Thomas W.H. Long-term complications after total knee arthroplasty with or without resurfacing of the patella. J Bone Joint Surg Am 1993, 75(5):674.
    • (1993) J Bone Joint Surg Am , vol.75 , Issue.5 , pp. 674
    • Boyd, A.D.1    Ewald, F.C.2    Thomas, W.H.3
  • 8
    • 0029126656 scopus 로고
    • Flexion space configuration in total knee arthroplasty
    • Laskin R.S. Flexion space configuration in total knee arthroplasty. J Arthroplasty 1995, 10:657-660.
    • (1995) J Arthroplasty , vol.10 , pp. 657-660
    • Laskin, R.S.1
  • 10
    • 37349078592 scopus 로고    scopus 로고
    • Custom-fit total knee arthroplasty (OtisKnee) results in malalignment
    • Klatt B.A., Goyal N., Austin M.S., Hozack W.J. Custom-fit total knee arthroplasty (OtisKnee) results in malalignment. J Arthroplasty 2008, 23(1):26-29.
    • (2008) J Arthroplasty , vol.23 , Issue.1 , pp. 26-29
    • Klatt, B.A.1    Goyal, N.2    Austin, M.S.3    Hozack, W.J.4
  • 11
    • 58149354595 scopus 로고    scopus 로고
    • Results of an initial experience with custom fit positioning total knee arthroplasty in a series of 48 patients
    • Howell S.M., Kuznik K., Hull M.L., Siston R.A. Results of an initial experience with custom fit positioning total knee arthroplasty in a series of 48 patients. Orthopedics 2008, 31:857.
    • (2008) Orthopedics , vol.31 , pp. 857
    • Howell, S.M.1    Kuznik, K.2    Hull, M.L.3    Siston, R.A.4
  • 12
    • 72349096775 scopus 로고    scopus 로고
    • Initial experience with custom-fit total knee replacement: intra-operative events and long-leg coronal alignment
    • Spencer B.A., Mont M.A., McGrath M.S., Boyd B., Mitrick M.F. Initial experience with custom-fit total knee replacement: intra-operative events and long-leg coronal alignment. Int Orthop 2009, 33:1571-1575.
    • (2009) Int Orthop , vol.33 , pp. 1571-1575
    • Spencer, B.A.1    Mont, M.A.2    McGrath, M.S.3    Boyd, B.4    Mitrick, M.F.5
  • 13
    • 83555176169 scopus 로고    scopus 로고
    • The value of patient-matched instrumentation in total knee arthroplasty
    • Noble J.W., Moore C.A., Liu N. The value of patient-matched instrumentation in total knee arthroplasty. J Arthroplasty 2012, 28:153-155.
    • (2012) J Arthroplasty , vol.28 , pp. 153-155
    • Noble, J.W.1    Moore, C.A.2    Liu, N.3
  • 14
    • 0032418168 scopus 로고    scopus 로고
    • Malrotation causing patellofemoral complications after total knee arthroplasty
    • Berger R.A., Crossett L.S., Jacobs J.J., Rubash H.E. Malrotation causing patellofemoral complications after total knee arthroplasty. Clin Orthop Relat Res 1998, 356:144-153.
    • (1998) Clin Orthop Relat Res , vol.356 , pp. 144-153
    • Berger, R.A.1    Crossett, L.S.2    Jacobs, J.J.3    Rubash, H.E.4
  • 15
    • 0027400765 scopus 로고
    • Determining the rotational alignment of the femoral component in total knee arthroplasty using the epicondylar axis
    • Berger R.A., Rubash H.E., Seel M.J., Warren H.T., Crosset L.S. Determining the rotational alignment of the femoral component in total knee arthroplasty using the epicondylar axis. Clin Orthop Relat Res 1993, 286:40-47.
    • (1993) Clin Orthop Relat Res , vol.286 , pp. 40-47
    • Berger, R.A.1    Rubash, H.E.2    Seel, M.J.3    Warren, H.T.4    Crosset, L.S.5
  • 16
    • 53649099385 scopus 로고    scopus 로고
    • Alignment in total knee replacement
    • Sikorski J.M. Alignment in total knee replacement. J Bone Joint Surg Br 2008, 90-B:1121-1127.
    • (2008) J Bone Joint Surg Br , pp. 1121-1127
    • Sikorski, J.M.1
  • 18
    • 0024447575 scopus 로고
    • Total condylar prosthesis: 10- to 12-year results of a cemented knee replacement
    • Vince K.G., Insall J.N., Kelly M.A. Total condylar prosthesis: 10- to 12-year results of a cemented knee replacement. J Bone Joint Surg Br 1989, 71-B:793-797.
    • (1989) J Bone Joint Surg Br , pp. 793-797
    • Vince, K.G.1    Insall, J.N.2    Kelly, M.A.3
  • 19
    • 34250223372 scopus 로고    scopus 로고
    • Factors associated with the loss of thickness of polyethylene tibial bearings after knee arthroplasty
    • Collier M.B., Engh C.A., McAuley J.P., Engh G.A. Factors associated with the loss of thickness of polyethylene tibial bearings after knee arthroplasty. J Bone Joint Surg 2007, 89-A:1306-1314.
    • (2007) J Bone Joint Surg , pp. 1306-1314
    • Collier, M.B.1    Engh, C.A.2    McAuley, J.P.3    Engh, G.A.4
  • 21
    • 10444234298 scopus 로고    scopus 로고
    • The effect of valgus/varus malalignment on load distribution in total knee replacements
    • Werner F.W., Ayers D.C., Maletsky L.P., Rullkoetter P.J. The effect of valgus/varus malalignment on load distribution in total knee replacements. J Biomech 2005, 38:349-355.
    • (2005) J Biomech , vol.38 , pp. 349-355
    • Werner, F.W.1    Ayers, D.C.2    Maletsky, L.P.3    Rullkoetter, P.J.4
  • 22
    • 77956999796 scopus 로고    scopus 로고
    • Effect of postoperative mechanical axis alignment on the fifteen-year survival of modern, cemented total knee replacements
    • Parratte S., Pagnano Mw, Trousdale R.T., Berry D.J. Effect of postoperative mechanical axis alignment on the fifteen-year survival of modern, cemented total knee replacements. J Bone Joint Surg 2010, 92:2143-2149.
    • (2010) J Bone Joint Surg , vol.92 , pp. 2143-2149
    • Parratte, S.1    Pagnano, M.2    Trousdale, R.T.3    Berry, D.J.4
  • 23
    • 80052794633 scopus 로고    scopus 로고
    • The effect of post-operative mechanical axis alignment on the survival of primary total knee replacements after a follow-up of 15years
    • Bonner T.J., Eardley W.G., Patterson P., Gregg P.J. The effect of post-operative mechanical axis alignment on the survival of primary total knee replacements after a follow-up of 15years. J Bone Joint Surg Br 2011, 93-B:1217-1222.
    • (2011) J Bone Joint Surg Br , pp. 1217-1222
    • Bonner, T.J.1    Eardley, W.G.2    Patterson, P.3    Gregg, P.J.4
  • 24
    • 1342305509 scopus 로고    scopus 로고
    • Low reproducibility of the intra-operative measurement of the transepicondylar axis during total knee replacement
    • Jenny J.Y., Boeri C. Low reproducibility of the intra-operative measurement of the transepicondylar axis during total knee replacement. Acta Orthop Scand 2004, 75(1):74-77.
    • (2004) Acta Orthop Scand , vol.75 , Issue.1 , pp. 74-77
    • Jenny, J.Y.1    Boeri, C.2
  • 25
    • 29244473544 scopus 로고    scopus 로고
    • Conventional instruments in total knee replacement. What should we do with them?
    • Shakespeare D. Conventional instruments in total knee replacement. What should we do with them?. Knee 2006, 13:1-6.
    • (2006) Knee , vol.13 , pp. 1-6
    • Shakespeare, D.1
  • 26
    • 52949115261 scopus 로고    scopus 로고
    • Comparative study between computer assisted-navigation and conventional technique in minimally invasive surgery total knee arthroplasty, prospective control study
    • Chotanaputi T., Ongnamthip P., Teeraleekul K., Kraturerk C. Comparative study between computer assisted-navigation and conventional technique in minimally invasive surgery total knee arthroplasty, prospective control study. J Med Assoc Thai 2008, 91(9):1382-1388.
    • (2008) J Med Assoc Thai , vol.91 , Issue.9 , pp. 1382-1388
    • Chotanaputi, T.1    Ongnamthip, P.2    Teeraleekul, K.3    Kraturerk, C.4
  • 27
    • 0242610028 scopus 로고    scopus 로고
    • How accurate is current TKR instrumentation?
    • Stulberg S.D. How accurate is current TKR instrumentation?. Clin Orthop Relat Res 2003, 416:177-184.
    • (2003) Clin Orthop Relat Res , vol.416 , pp. 177-184
    • Stulberg, S.D.1
  • 28
    • 0033747697 scopus 로고    scopus 로고
    • Axial alignment of the lower extremity in Chinese adults
    • Tang W.M., Zhu Y.H., Chiu K.Y. Axial alignment of the lower extremity in Chinese adults. J Bone Joint Surg 2000, 82-A(11):1603-1608.
    • (2000) J Bone Joint Surg , Issue.11 , pp. 1603-1608
    • Tang, W.M.1    Zhu, Y.H.2    Chiu, K.Y.3
  • 29
    • 42449157210 scopus 로고    scopus 로고
    • Accuracy of femoral rotational alignment in total knee arthroplasty using computer assisted navigation
    • Restrepo C., Hozack W.J., Orozco F., Parvizi J. Accuracy of femoral rotational alignment in total knee arthroplasty using computer assisted navigation. Comput Aided Surg 2008, 13(3):167-172.
    • (2008) Comput Aided Surg , vol.13 , Issue.3 , pp. 167-172
    • Restrepo, C.1    Hozack, W.J.2    Orozco, F.3    Parvizi, J.4
  • 30
    • 79955944501 scopus 로고    scopus 로고
    • Imageless computer assisted versus conventional total knee replacement: a Bayesian meta-analysis of 23 comparative studies
    • Brin Y.S., Nikolaou V.S., Joseph L., Zukor D.J., Antoniou J. Imageless computer assisted versus conventional total knee replacement: a Bayesian meta-analysis of 23 comparative studies. Int Orthop 2011, 35:331-339.
    • (2011) Int Orthop , vol.35 , pp. 331-339
    • Brin, Y.S.1    Nikolaou, V.S.2    Joseph, L.3    Zukor, D.J.4    Antoniou, J.5
  • 32
    • 80052857490 scopus 로고    scopus 로고
    • Computer-assisted techniques versus conventional guides for component alignment in total knee arthroplasty: a randomized controlled trial
    • Blakeney W.G., Khan R.J., Wall S.J. Computer-assisted techniques versus conventional guides for component alignment in total knee arthroplasty: a randomized controlled trial. J Bone Joint Surg 2011, 93(15):1377-1384.
    • (2011) J Bone Joint Surg , vol.93 , Issue.15 , pp. 1377-1384
    • Blakeney, W.G.1    Khan, R.J.2    Wall, S.J.3
  • 33
    • 79956364562 scopus 로고    scopus 로고
    • Critical review of the current practice for computer-assisted navigation in total knee replacement surgery: cost-effectiveness and clinical outcome
    • Desai A.S., Dramis A., Kendoff D., Board T.N. Critical review of the current practice for computer-assisted navigation in total knee replacement surgery: cost-effectiveness and clinical outcome. Curr Rev Musculoskelet Med 2011, 4:11-15.
    • (2011) Curr Rev Musculoskelet Med , vol.4 , pp. 11-15
    • Desai, A.S.1    Dramis, A.2    Kendoff, D.3    Board, T.N.4
  • 34
    • 40749098983 scopus 로고    scopus 로고
    • Minimally invasive imageless computer-navigated knee surgery: initial results
    • Chandrasekaran S., Molnar R.B. Minimally invasive imageless computer-navigated knee surgery: initial results. J Arthroplasty 2008, 23(3):441-445.
    • (2008) J Arthroplasty , vol.23 , Issue.3 , pp. 441-445
    • Chandrasekaran, S.1    Molnar, R.B.2
  • 35
    • 84871608257 scopus 로고    scopus 로고
    • Sagittal cutting error changes femoral anteroposterior sizing in total knee arthroplasty
    • Nakahara H., Matsuda S., Okazaki, Tashiro Y., Iwamoto Y. Sagittal cutting error changes femoral anteroposterior sizing in total knee arthroplasty. Clin Orthop Relat Res 2012, 470:3560-3565.
    • (2012) Clin Orthop Relat Res , vol.470 , pp. 3560-3565
    • Nakahara, H.1    Matsuda, S.2    Okazaki3    Tashiro, Y.4    Iwamoto, Y.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.