메뉴 건너뛰기




Volumn 26, Issue 4, 2015, Pages 442-446

Healing of implants installed in over- or under-prepared sites - An experimental study in dogs

Author keywords

Animal study; Bone healing; Dental implants; Histology; Implant dentistry; Insertion torque; Rotational mobility; Spin

Indexed keywords

TOOTH IMPLANT;

EID: 84924208671     PISSN: 09057161     EISSN: 16000501     Source Type: Journal    
DOI: 10.1111/clr.12390     Document Type: Article
Times cited : (35)

References (25)
  • 1
    • 34547315515 scopus 로고    scopus 로고
    • A retrospective analysis of 44 implants with no rotational primary stability used for fixed prosthesis anchorage
    • Balshi, S.F., Wolfinger, G.J. & Balshi, T.J. (2007) A retrospective analysis of 44 implants with no rotational primary stability used for fixed prosthesis anchorage. The International Journal of Oral Maxillofacial Implants 22: 467-471.
    • (2007) The International Journal of Oral Maxillofacial Implants , vol.22 , pp. 467-471
    • Balshi, S.F.1    Wolfinger, G.J.2    Balshi, T.J.3
  • 2
    • 0003009638 scopus 로고
    • The influence of force, motion, and related quantities on the response of bone to implants
    • In: Fitzgerald, R. Jr, ed., New York: Raven Press.
    • Brunski, J.B. (1988) The influence of force, motion, and related quantities on the response of bone to implants. In: Fitzgerald, R. Jr, ed. Non Cemented Total Hip Arthroplasty, 43. New York: Raven Press.
    • (1988) Non Cemented Total Hip Arthroplasty , pp. 43
    • Brunski, J.B.1
  • 3
    • 84860890234 scopus 로고    scopus 로고
    • Implants inserted with low insertion torque values for intraoral welded full-arch prosthesis: 1-year follow-up
    • Degidi, M., Daprile, G. & Piattelli, A. (2012) Implants inserted with low insertion torque values for intraoral welded full-arch prosthesis: 1-year follow-up. Clinical Implant Dentistry & Related Research 14(Suppl. 1): e39-e45. doi:10.1111/j.1708-8208.2011.00345.x.
    • (2012) Clinical Implant Dentistry & Related Research , vol.14 , pp. e39-e45
    • Degidi, M.1    Daprile, G.2    Piattelli, A.3
  • 5
    • 0030155422 scopus 로고    scopus 로고
    • Loss of osseointegration caused by occlusal load of oral implants. A clinical and radiographic study in monkeys
    • Isidor, F. (1996) Loss of osseointegration caused by occlusal load of oral implants. A clinical and radiographic study in monkeys. Clinical Oral Implants Research 7: 143-152.
    • (1996) Clinical Oral Implants Research , vol.7 , pp. 143-152
    • Isidor, F.1
  • 6
    • 0031061799 scopus 로고    scopus 로고
    • Histological evaluation of peri-implant bone at implants subjected to occlusal overload or plaque accumulation
    • Isidor, F. (1997) Histological evaluation of peri-implant bone at implants subjected to occlusal overload or plaque accumulation. Clinical Oral Implants Research 8: 1-9.
    • (1997) Clinical Oral Implants Research , vol.8 , pp. 1-9
    • Isidor, F.1
  • 7
    • 0030155740 scopus 로고    scopus 로고
    • Influence of initial implant mobility on the integration of titanium implants. An experimental study in rabbits
    • Ivanoff, C.J., Sennerby, L. & Lekholm, U. (1996) Influence of initial implant mobility on the integration of titanium implants. An experimental study in rabbits. Clinical Oral Implants Research 7: 120-127.
    • (1996) Clinical Oral Implants Research , vol.7 , pp. 120-127
    • Ivanoff, C.J.1    Sennerby, L.2    Lekholm, U.3
  • 8
    • 84908608817 scopus 로고    scopus 로고
    • Secondary stability of microthickness hydroxyapatite-coated dental implants installed without primary stability in dogs
    • [Epub ahead of print].
    • Jung, U.W., Kim, S., Lee, I.K., Kim, M.S., Lee, J.S. & Kim, H.J. (2013) Secondary stability of microthickness hydroxyapatite-coated dental implants installed without primary stability in dogs. Clinical Oral Implants Research doi: 10.1111/clr.12226. [Epub ahead of print].
    • (2013) Clinical Oral Implants Research
    • Jung, U.W.1    Kim, S.2    Lee, I.K.3    Kim, M.S.4    Lee, J.S.5    Kim, H.J.6
  • 9
    • 84899868691 scopus 로고    scopus 로고
    • Reosseointegration of mechanically disintegrated implants in dogs: mechanical and histometric analyses
    • [Epub ahead of print].
    • Kim, S., Lee, J.S., Hwang, J.W., Kim, M.S., Choi, S.H. & Jung, U.W. (2013) Reosseointegration of mechanically disintegrated implants in dogs: mechanical and histometric analyses. Clinical Oral Implants Research doi: 10.1111/clr.12135. [Epub ahead of print].
    • (2013) Clinical Oral Implants Research
    • Kim, S.1    Lee, J.S.2    Hwang, J.W.3    Kim, M.S.4    Choi, S.H.5    Jung, U.W.6
  • 10
    • 33646502118 scopus 로고    scopus 로고
    • Significance of primary stability for osseointegration of dental implants
    • Lioubavina-Hack, N., Lang, N.P. & Karring, T. (2006) Significance of primary stability for osseointegration of dental implants. Clinical Oral Implants Research 17: 244-250.
    • (2006) Clinical Oral Implants Research , vol.17 , pp. 244-250
    • Lioubavina-Hack, N.1    Lang, N.P.2    Karring, T.3
  • 11
    • 33748098501 scopus 로고    scopus 로고
    • Reintegration success of osseotite implants after intentional countertorque liberation in the edentulous human mandible
    • Lucente, J., Galante, J., Trisi, P. & Kenealy, J.N. (2006) Reintegration success of osseotite implants after intentional countertorque liberation in the edentulous human mandible. Implant Dentistry 15: 178-185.
    • (2006) Implant Dentistry , vol.15 , pp. 178-185
    • Lucente, J.1    Galante, J.2    Trisi, P.3    Kenealy, J.N.4
  • 13
    • 0026921680 scopus 로고
    • Fixture design and overload influence marginal bone loss and fixture success in the Branemark system
    • Quirynen, M., Naert, I. & van Steenberghe, D. (1992) Fixture design and overload influence marginal bone loss and fixture success in the Branemark system. Clinical Oral Implants Research 3: 104-111.
    • (1992) Clinical Oral Implants Research , vol.3 , pp. 104-111
    • Quirynen, M.1    Naert, I.2    van Steenberghe, D.3
  • 14
    • 84924208671 scopus 로고    scopus 로고
    • Influence of immediate loading on healing of implants installed with different insertion torques - an experimental study in dogs
    • [Epub ahead of print].
    • Rea, M., Botticelli, D., Ricci, S., Soldini, C., González González, G. & Lang, N.P. (2013) Influence of immediate loading on healing of implants installed with different insertion torques - an experimental study in dogs. Clinical Oral Implants Research doi: 10.1111/clr.12305. [Epub ahead of print].
    • (2013) Clinical Oral Implants Research
    • Rea, M.1    Botticelli, D.2    Ricci, S.3    Soldini, C.4    González González, G.5    Lang, N.P.6
  • 15
    • 0035650821 scopus 로고    scopus 로고
    • Early loading of sandblasted and acid-etched (SLA) implants: a prospective split-mouth comparative study
    • Roccuzzo, M., Bunino, M., Prioglio, F. & Bianchi, S.D. (2001) Early loading of sandblasted and acid-etched (SLA) implants: a prospective split-mouth comparative study. Clinical Oral Implants Research 12: 572-578.
    • (2001) Clinical Oral Implants Research , vol.12 , pp. 572-578
    • Roccuzzo, M.1    Bunino, M.2    Prioglio, F.3    Bianchi, S.D.4
  • 16
    • 76949084768 scopus 로고    scopus 로고
    • Diagnosis of implant stability and its impact on implant survival: a prospective case series study
    • Rodrigo, D., Aracil, L., Martin, C. & Sanz, M. (2010) Diagnosis of implant stability and its impact on implant survival: a prospective case series study. Clinical Oral Implants Research 21: 255-261.
    • (2010) Clinical Oral Implants Research , vol.21 , pp. 255-261
    • Rodrigo, D.1    Aracil, L.2    Martin, C.3    Sanz, M.4
  • 17
    • 2942657499 scopus 로고    scopus 로고
    • Early loading (2 or 6 weeks) of sandblasted and acid-etched (SLA) ITI implants in the posterior mandible. A 1-year randomized controlled clinical trial
    • Salvi, G.E., Gallini, G. & Lang, N.P. (2004) Early loading (2 or 6 weeks) of sandblasted and acid-etched (SLA) ITI implants in the posterior mandible. A 1-year randomized controlled clinical trial. Clinical Oral Implants Research 15: 142-149.
    • (2004) Clinical Oral Implants Research , vol.15 , pp. 142-149
    • Salvi, G.E.1    Gallini, G.2    Lang, N.P.3
  • 18
    • 0026192166 scopus 로고
    • Histopathologic characteristics of peri-implant soft tissue in Branemark implants with 2 distinct clinical and radiological patterns. A histometric and ultrastructural study
    • Sanz, M., Alandez, J., Lazaro, P., Calvo, J.L., Quirynen, M. & van Steenberghe, D. (1991) Histopathologic characteristics of peri-implant soft tissue in Branemark implants with 2 distinct clinical and radiological patterns. A histometric and ultrastructural study. Clinical Oral Implants Research 2: 128-134.
    • (1991) Clinical Oral Implants Research , vol.2 , pp. 128-134
    • Sanz, M.1    Alandez, J.2    Lazaro, P.3    Calvo, J.L.4    Quirynen, M.5    van Steenberghe, D.6
  • 19
    • 0026521288 scopus 로고
    • Hydroxyapatite coating modifies implant membrane formation. Controlled micromotion studied in dogs
    • Søballe, K., Brockstedt-Rasmussen, H., Hansen, E.S. & Bunger, C. (1992) Hydroxyapatite coating modifies implant membrane formation. Controlled micromotion studied in dogs. Acta Orthopaedica Scandinavica 63: 128-140.
    • (1992) Acta Orthopaedica Scandinavica , vol.63 , pp. 128-140
    • Søballe, K.1    Brockstedt-Rasmussen, H.2    Hansen, E.S.3    Bunger, C.4
  • 21
    • 38549134337 scopus 로고    scopus 로고
    • Immediate occlusal loading and tilted implants for the rehabilitation of the atrophic edentulous maxilla: 1-year interim results of a multicenter prospective study
    • Testori, T., Del Fabbro, M., Capelli, M., Zuffetti, F., Francetti, L. & Weinstein, R.L. (2008) Immediate occlusal loading and tilted implants for the rehabilitation of the atrophic edentulous maxilla: 1-year interim results of a multicenter prospective study. Clinical Oral Implant Research 19: 227-232.
    • (2008) Clinical Oral Implant Research , vol.19 , pp. 227-232
    • Testori, T.1    Del Fabbro, M.2    Capelli, M.3    Zuffetti, F.4    Francetti, L.5    Weinstein, R.L.6
  • 23
    • 84555204343 scopus 로고    scopus 로고
    • High versus low implant insertion torque: a histologic, histomorphometric, and biomechanical study in the sheep mandible
    • Trisi, P., Todisco, M., Consolo, U. & Travaglini, D. (2011) High versus low implant insertion torque: a histologic, histomorphometric, and biomechanical study in the sheep mandible. The International Journal of Oral Maxillofacial Implants 26: 837-849.
    • (2011) The International Journal of Oral Maxillofacial Implants , vol.26 , pp. 837-849
    • Trisi, P.1    Todisco, M.2    Consolo, U.3    Travaglini, D.4
  • 24
    • 33846951753 scopus 로고    scopus 로고
    • The effect of micro-motion on the tissue response around immediately loaded roughened titanium implants in the rabbit
    • Vandamme, K., Naert, I., Geris, L., Vander Sloten, J., Puers, R. & Duyck, J. (2007) The effect of micro-motion on the tissue response around immediately loaded roughened titanium implants in the rabbit. European Journal of Oral Sciences 115: 21-29.
    • (2007) European Journal of Oral Sciences , vol.115 , pp. 21-29
    • Vandamme, K.1    Naert, I.2    Geris, L.3    Vander Sloten, J.4    Puers, R.5    Duyck, J.6
  • 25
    • 68549092607 scopus 로고    scopus 로고
    • Effects of titanium surface topography on bone integration: a systematic review
    • Wennerberg, A. & Albrektsson, T. (2009) Effects of titanium surface topography on bone integration: a systematic review. Clinical Oral Implants Research 20(Suppl. 4): 172-184.
    • (2009) Clinical Oral Implants Research , vol.20 , pp. 172-184
    • Wennerberg, A.1    Albrektsson, T.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.