메뉴 건너뛰기




Volumn 25, Issue 10, 2014, Pages 1169-1174

Secondary stability of microthickness hydroxyapatite-coated dental implants installed without primary stability in dogs

Author keywords

Histomorphometry; Hydroxyapatite; Implant stability; Implant surface; Titanium

Indexed keywords

BIOMATERIAL; HYDROXYAPATITE; TITANIUM; TOOTH IMPLANT;

EID: 84908608817     PISSN: 09057161     EISSN: 16000501     Source Type: Journal    
DOI: 10.1111/clr.12226     Document Type: Article
Times cited : (18)

References (32)
  • 1
    • 4644241352 scopus 로고    scopus 로고
    • Early bone formation adjacent to rough and turned endosseous implant surfaces. An experimental study in the dog
    • Abrahamsson, I., Berglundh, T., Linder, E., Lang, N.P. & Lindhe, J. (2004) Early bone formation adjacent to rough and turned endosseous implant surfaces. An experimental study in the dog.. Clinical Oral Implants Research 15: 381-392.
    • (2004) Clinical Oral Implants Research , vol.15 , pp. 381-392
    • Abrahamsson, I.1    Berglundh, T.2    Linder, E.3    Lang, N.P.4    Lindhe, J.5
  • 2
    • 0029396732 scopus 로고
    • Evaluation of the clinical predictability of hydroxyapatitecoated endosseous dental implants: a review of the literature
    • Biesbrock, A.R. & Edgerton, M. (1995) Evaluation of the clinical predictability of hydroxyapatitecoated endosseous dental implants: a review of the literature. The International Journal of Oral & Maxillofacial Implants 10: 712-720.
    • (1995) The International Journal of Oral & Maxillofacial Implants , vol.10 , pp. 712-720
    • Biesbrock, A.R.1    Edgerton, M.2
  • 3
    • 0020823258 scopus 로고
    • Osseointegration and its experimental background
    • Branemark, P.I. (1983) Osseointegration and its experimental background. Journal of Prosthetic Dentistry 50: 399-410.
    • (1983) Journal of Prosthetic Dentistry , vol.50 , pp. 399-410
    • Branemark, P.I.1
  • 4
    • 0030087954 scopus 로고    scopus 로고
    • Influence of annealing temperature on rf magnetron sputtered calcium phosphate coatings
    • van Dijk, K., Schaeken, H.G., Wolke, J.G. & Jansen, J.A. (1996) Influence of annealing temperature on rf magnetron sputtered calcium phosphate coatings. Biomaterials 17: 405-410.
    • (1996) Biomaterials , vol.17 , pp. 405-410
    • van Dijk, K.1    Schaeken, H.G.2    Wolke, J.G.3    Jansen, J.A.4
  • 7
    • 0030155740 scopus 로고    scopus 로고
    • Influence of initial implant mobility on the integration of titanium implants. An experimental study in rabbits
    • Ivanoff, C.J., Sennerby, L. & Lekholm, U. (1996) Influence of initial implant mobility on the integration of titanium implants. An experimental study in rabbits. Clinical Oral Implants Research 7: 120-127.
    • (1996) Clinical Oral Implants Research , vol.7 , pp. 120-127
    • Ivanoff, C.J.1    Sennerby, L.2    Lekholm, U.3
  • 9
    • 33847691446 scopus 로고    scopus 로고
    • Healing of surgically created circumferential gap around non-submerged-type implants in dogs: a histomorphometric study
    • Jung, U.-W., Kim, C.-S., Choi, S.-H., Cho, K.-S., Inoue, T. & Kim, C.-K. (2007) Healing of surgically created circumferential gap around non-submerged-type implants in dogs: a histomorphometric study. Clinical Oral Implants Research 18: 171-178.
    • (2007) Clinical Oral Implants Research , vol.18 , pp. 171-178
    • Jung, U.-W.1    Kim, C.-S.2    Choi, S.-H.3    Cho, K.-S.4    Inoue, T.5    Kim, C.-K.6
  • 10
    • 84867603063 scopus 로고    scopus 로고
    • Osseointegration of dental implants installed without mechanical engagement: a histometric analysis in dogs
    • Jung, U.W., Kim, S., Kim, Y.H., Cha, J.K., Lee, I.S. & Choi, S.H. (2012b) Osseointegration of dental implants installed without mechanical engagement: a histometric analysis in dogs. Clinical Oral Implants Research 23: 1297-1301.
    • (2012) Clinical Oral Implants Research , vol.23 , pp. 1297-1301
    • Jung, U.W.1    Kim, S.2    Kim, Y.H.3    Cha, J.K.4    Lee, I.S.5    Choi, S.H.6
  • 11
    • 84875893911 scopus 로고    scopus 로고
    • Bone apposition on implants coated with calcium phosphate by ion beam assisted deposition in oversized drilled sockets: a histologic and histometric analysis in dogs
    • Kim, M.S., Jung, U.W., Kim, S., Lee, J.S., Lee, I.S. & Choi, S.H. (2013) Bone apposition on implants coated with calcium phosphate by ion beam assisted deposition in oversized drilled sockets: a histologic and histometric analysis in dogs. Journal of Periodontal & Implant Science 43: 18-23.
    • (2013) Journal of Periodontal & Implant Science , vol.43 , pp. 18-23
    • Kim, M.S.1    Jung, U.W.2    Kim, S.3    Lee, J.S.4    Lee, I.S.5    Choi, S.H.6
  • 14
    • 0031061758 scopus 로고    scopus 로고
    • Stability of hydroxyapatite-coatings on titanium oral implants (imz). 2 retrieved cases
    • Liao, H., Fartash, B. & Li, J. (1997) Stability of hydroxyapatite-coatings on titanium oral implants (imz). 2 retrieved cases. Clinical Oral Implants Research 8: 68-72.
    • (1997) Clinical Oral Implants Research , vol.8 , pp. 68-72
    • Liao, H.1    Fartash, B.2    Li, J.3
  • 15
    • 33646502118 scopus 로고    scopus 로고
    • Significance of primary stability for osseointegration of dental implants
    • Lioubavina-Hack, N., Lang, N.P. & Karring, T. (2006) Significance of primary stability for osseointegration of dental implants. Clinical Oral Implants Research 17: 244-250.
    • (2006) Clinical Oral Implants Research , vol.17 , pp. 244-250
    • Lioubavina-Hack, N.1    Lang, N.P.2    Karring, T.3
  • 16
    • 0032151752 scopus 로고    scopus 로고
    • Assessment of implant stability as a prognostic determinant
    • Meredith, N. (1998) Assessment of implant stability as a prognostic determinant. The International Journal of Prosthodontics 11: 491-501.
    • (1998) The International Journal of Prosthodontics , vol.11 , pp. 491-501
    • Meredith, N.1
  • 17
    • 84875951155 scopus 로고    scopus 로고
    • nparLD: an R software package for the nonparametric analysis of longitudinal data in factorial experiments
    • Noguchi, K., Gel, Y.R., Brunner, E. & Konietschke, F. (2012) nparLD: an R software package for the nonparametric analysis of longitudinal data in factorial experiments. Journal of Statistical Software 50: 1-23.
    • (2012) Journal of Statistical Software , vol.50 , pp. 1-23
    • Noguchi, K.1    Gel, Y.R.2    Brunner, E.3    Konietschke, F.4
  • 18
    • 0026538167 scopus 로고
    • Structure, solubility and bond strength of thin calcium phosphate coatings produced by ion beam sputter deposition
    • Ong, J.L., Lucas, L.C., Lacefield, W.R. & Rigney, E.D. (1992) Structure, solubility and bond strength of thin calcium phosphate coatings produced by ion beam sputter deposition. Biomaterials 13: 249-254.
    • (1992) Biomaterials , vol.13 , pp. 249-254
    • Ong, J.L.1    Lucas, L.C.2    Lacefield, W.R.3    Rigney, E.D.4
  • 19
    • 0032233376 scopus 로고    scopus 로고
    • Factors affecting implant mobility at placement and integration of mobile implants at uncovering
    • Orenstein, I.H., Tarnow, D.P., Morris, H.F. & Ochi, S. (1998) Factors affecting implant mobility at placement and integration of mobile implants at uncovering. Journal of Periodontology 69: 1404-1412.
    • (1998) Journal of Periodontology , vol.69 , pp. 1404-1412
    • Orenstein, I.H.1    Tarnow, D.P.2    Morris, H.F.3    Ochi, S.4
  • 21
    • 14844350576 scopus 로고    scopus 로고
    • The effects of ion beam-assisted deposition of hydroxyapatite on the grit-blasted surface of endosseous implants in rabbit tibiae
    • Park, Y.S., Yi, K.Y., Lee, I.S., Han, C.H. & Jung, Y.C. (2005) The effects of ion beam-assisted deposition of hydroxyapatite on the grit-blasted surface of endosseous implants in rabbit tibiae. The International Journal of Oral & Maxillofacial Implants 20: 31-38.
    • (2005) The International Journal of Oral & Maxillofacial Implants , vol.20 , pp. 31-38
    • Park, Y.S.1    Yi, K.Y.2    Lee, I.S.3    Han, C.H.4    Jung, Y.C.5
  • 22
    • 0026826756 scopus 로고
    • A morphometric and biomechanic comparison of titanium implants inserted in rabbit cortical and cancellous bone
    • Sennerby, L., Thomsen, P. & Ericson, L.E. (1992) A morphometric and biomechanic comparison of titanium implants inserted in rabbit cortical and cancellous bone. The International Journal of Oral & Maxillofacial Implants 7: 62-71.
    • (1992) The International Journal of Oral & Maxillofacial Implants , vol.7 , pp. 62-71
    • Sennerby, L.1    Thomsen, P.2    Ericson, L.E.3
  • 26
    • 0023471993 scopus 로고
    • The effect of surface macrotexture and hydroxylapatite coating on the mechanical strengths and histologic profiles of titanium implant materials
    • Thomas, K.A., Kay, J.F., Cook, S.D. & Jarcho, M. (1987) The effect of surface macrotexture and hydroxylapatite coating on the mechanical strengths and histologic profiles of titanium implant materials. Journal of Biomedical Materials Research 21: 1395-1414.
    • (1987) Journal of Biomedical Materials Research , vol.21 , pp. 1395-1414
    • Thomas, K.A.1    Kay, J.F.2    Cook, S.D.3    Jarcho, M.4
  • 27
    • 0034584296 scopus 로고    scopus 로고
    • Stability of the bone-implant complex. Results of longitudinal testing to 60 months with the periotest device on endosseous dental implants
    • Truhlar, R.S., Morris, H.F. & Ochi, S. (2000) Stability of the bone-implant complex. Results of longitudinal testing to 60 months with the periotest device on endosseous dental implants. Annals of Periodontology 5: 42-55.
    • (2000) Annals of Periodontology , vol.5 , pp. 42-55
    • Truhlar, R.S.1    Morris, H.F.2    Ochi, S.3
  • 28
    • 65649109402 scopus 로고    scopus 로고
    • The effect of post heat treatment of hydroxyapatitecoated implants on the healing of circumferential coronal defects in dogs
    • Um, Y.J., Song, J.E., Chae, G.J., Jung, U.W., Chung, S.M., Lee, I.S., Cho, K.S. & Choi, S.H. (2009) The effect of post heat treatment of hydroxyapatitecoated implants on the healing of circumferential coronal defects in dogs. Thin Solid Films 517: 5375-5379.
    • (2009) Thin Solid Films , vol.517 , pp. 5375-5379
    • Um, Y.J.1    Song, J.E.2    Chae, G.J.3    Jung, U.W.4    Chung, S.M.5    Lee, I.S.6    Cho, K.S.7    Choi, S.H.8
  • 29
    • 40549086917 scopus 로고    scopus 로고
    • Comparison of biological characteristics of mesenchymal stem cells grown on two different titanium implant surfaces
    • Wang, C.Y., Zhao, B.H., Ai, H.J. & Wang, Y.W. (2008) Comparison of biological characteristics of mesenchymal stem cells grown on two different titanium implant surfaces. Biomedical Materials (Bristol, England) 3: 015004.
    • (2008) Biomedical Materials (Bristol, England) , vol.3 , pp. 015004
    • Wang, C.Y.1    Zhao, B.H.2    Ai, H.J.3    Wang, Y.W.4
  • 31
    • 84875485147 scopus 로고    scopus 로고
    • Effect of model parameters on finite element analysis of micromotions in implant dentistry
    • Winter, W., Klein, D. & Karl, M. (2013) Effect of model parameters on finite element analysis of micromotions in implant dentistry. The Journal of Oral Implantology 39: 23-29.
    • (2013) The Journal of Oral Implantology , vol.39 , pp. 23-29
    • Winter, W.1    Klein, D.2    Karl, M.3
  • 32
    • 0028454994 scopus 로고
    • Thin hydroxyapatite coating produced by the ion beam dynamic mixing method
    • Yoshinari, M., Ohtsuka, Y. & Derand, T. (1994) Thin hydroxyapatite coating produced by the ion beam dynamic mixing method. Biomaterials 15: 529-535.
    • (1994) Biomaterials , vol.15 , pp. 529-535
    • Yoshinari, M.1    Ohtsuka, Y.2    Derand, T.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.