메뉴 건너뛰기




Volumn 26, Issue 4, 2011, Pages 837-849

High versus low implant insertion torque: A histologic, histomorphometric, and biomechanical study in the sheep mandible

Author keywords

Biomechanics; Bone compression; Dental implants; Histology; Insertion torque; Primary stability

Indexed keywords

ANIMAL; ARTICLE; BIOMECHANICS; BONE DENSITY; BONE REGENERATION; COMPRESSIVE STRENGTH; DENTAL PROCEDURE; DEVICE REMOVAL; FEMALE; MANDIBLE; METHODOLOGY; PHYSIOLOGY; POROSITY; SHEEP; TOOTH IMPLANTATION; TOOTH PROSTHESIS; TORQUE; VIBRATION; WOUND HEALING;

EID: 84555204343     PISSN: 08822786     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (104)

References (45)
  • 1
    • 0031061750 scopus 로고    scopus 로고
    • Implant-retained mandibular overdentures with immediate loading. A retrospective multicenter study on 226 consecutive cases
    • Chiapasco M, Gatti C, Rossi E, Haefliger W, Markwalder TH. Implant-retained mandibular overdentures with immediate loading. A retrospective multicenter study on 226 consecutive cases. Clin Oral Implants Res 1997;8:48-57.
    • (1997) Clin Oral Implants Res , vol.8 , pp. 48-57
    • Chiapasco, M.1    Gatti, C.2    Rossi, E.3    Haefliger, W.4    Markwalder, T.H.5
  • 2
    • 0029348226 scopus 로고
    • Immediate loading of bilaterally splinted titanium root-form implants in fixed prosthodontics-A technique reexamined: Two case reports
    • Salama H, Rose LF, Salama M, Betts NJ. Immediate loading of bilaterally splinted titanium root-form implants in fixed prosthodontics-A technique reexamined: Two case reports. Int J Periodontics Restorative Dent 1995;15:344-361.
    • (1995) Int J Periodontics Restorative Dent , vol.15 , pp. 344-361
    • Salama, H.1    Rose, L.F.2    Salama, M.3    Betts, N.J.4
  • 3
    • 0025618219 scopus 로고
    • Immediate fixed interim prostheses supported by two-stage threaded implants:Methodology and results
    • Schnitman PA, Wohrle PS, Rubenstein JE. Immediate fixed interim prostheses supported by two-stage threaded implants:Methodology and results. J Oral Implantol 1990;16:96-105.
    • (1990) J Oral Implantol , vol.16 , pp. 96-105
    • Schnitman, P.A.1    Wohrle, P.S.2    Rubenstein, J.E.3
  • 4
    • 0031136510 scopus 로고    scopus 로고
    • Immediate loading of threaded implants at stage 1 surgery in edentulous arches: Ten consecutive case reports with 1- to 5-year data
    • Tarnow DP, Emtiaz S, Classi A. Immediate loading of threaded implants at stage 1 surgery in edentulous arches: Ten consecutive case reports with 1- to 5-year data. Int J Oral Maxillofac Implants 1997;12:319-324.
    • (1997) Int J Oral Maxillofac Implants , vol.12 , pp. 319-324
    • Tarnow, D.P.1    Emtiaz, S.2    Classi, A.3
  • 6
    • 0141831255 scopus 로고    scopus 로고
    • Restoration of partially edentulous patients using dental implants with a microtextured surface:A prospective comparison of delayed and immediate full occlusal loading
    • Cannizzaro G, Leone M. Restoration of partially edentulous patients using dental implants with a microtextured surface:A prospective comparison of delayed and immediate full occlusal loading. Int J Oral Maxillofac Implants 2003;18:512-522.
    • (2003) Int J Oral Maxillofac Implants , vol.18 , pp. 512-522
    • Cannizzaro, G.1    Leone, M.2
  • 7
    • 0027792232 scopus 로고
    • Histologic analysis of a screw implant retrieved from man: Influence of early loading and primary stability
    • Piattelli A, Trisi P, Romasco N, Emanuelli M. Histologic analysis of a screw implant retrieved from man: Influence of early loading and primary stability. J Oral Implantol 1993;19:303-306.
    • (1993) J Oral Implantol , vol.19 , pp. 303-306
    • Piattelli, A.1    Trisi, P.2    Romasco, N.3    Emanuelli, M.4
  • 8
    • 0027830480 scopus 로고
    • An histologic and histomorphometric study of bone reactions to unloaded and loaded non-submerged single implants in monkeys: A pilot study
    • Piattelli A, Ruggeri A, Franchi M, Romasco N, Trisi P. An histologic and histomorphometric study of bone reactions to unloaded and loaded non-submerged single implants in monkeys: A pilot study. J Oral Implantol 1993;19:314-320.
    • (1993) J Oral Implantol , vol.19 , pp. 314-320
    • Piattelli, A.1    Ruggeri, A.2    Franchi, M.3    Romasco, N.4    Trisi, P.5
  • 9
    • 0030981647 scopus 로고    scopus 로고
    • Immediate loading of titanium plasma-sprayed screw-shaped implants in man: A clinical and histological report of two cases
    • Piattelli A, Paolantonio M, Corigliano M, Scarano A. Immediate loading of titanium plasma-sprayed screw-shaped implants in man: A clinical and histological report of two cases. J Periodontol 1997;68:591-597.
    • (1997) J Periodontol , vol.68 , pp. 591-597
    • Piattelli, A.1    Paolantonio, M.2    Corigliano, M.3    Scarano, A.4
  • 10
    • 0027597595 scopus 로고
    • A light microscopy, scanning electron microscopy and laser scanning microscopy analysis of retrieved blade implants after 7 to 20 years of clinical function
    • Trisi P, Piattelli A, Quaranta M, Emanuelli M. A light microscopy, scanning electron microscopy and laser scanning microscopy analysis of retrieved blade implants after 7 to 20 years of clinical function. J Periodontol 1993;64:374-378.
    • (1993) J Periodontol , vol.64 , pp. 374-378
    • Trisi, P.1    Piattelli, A.2    Quaranta, M.3    Emanuelli, M.4
  • 12
    • 0034139407 scopus 로고    scopus 로고
    • Considerations preliminary to the application of early and immediate loading protocols in dental implantology
    • Szmukler-Moncler S, Piattelli A, Favero GA, Dubruille JH. Considerations preliminary to the application of early and immediate loading protocols in dental implantology. Clin Oral Implants Res 2000;11:12-25.
    • (2000) Clin Oral Implants Res , vol.11 , pp. 12-25
    • Szmukler-Moncler, S.1    Piattelli, A.2    Favero, G.A.3    Dubruille, J.H.4
  • 13
    • 0034574211 scopus 로고    scopus 로고
    • Measurements comparing the initial stability of five designs of dental implants: A human cadaver study
    • O’Sullivan D, Sennerby L, Meredith N. Measurements comparing the initial stability of five designs of dental implants: A human cadaver study. Clin Implant Dent Relat Res 2000;2:85-92.
    • (2000) Clin Implant Dent Relat Res , vol.2 , pp. 85-92
    • O’Sullivan, D.1    Sennerby, L.2    Meredith, N.3
  • 15
    • 0026826756 scopus 로고
    • A morphometric and biomechanic comparison of titanium implants inserted in rabbit cortical and cancellous bone
    • Sennerby L, Thomsen P, Ericson LE. A morphometric and biomechanic comparison of titanium implants inserted in rabbit cortical and cancellous bone. Int J Oral Maxillofac Implants 1992;7:62-71.
    • (1992) Int J Oral Maxillofac Implants , vol.7 , pp. 62-71
    • Sennerby, L.1    Thomsen, P.2    Ericson, L.E.3
  • 16
    • 0031197165 scopus 로고    scopus 로고
    • A comparative study of removal torque of endosseous implants in the fibula, iliac crest and scapula of cadavers: Preliminary report
    • Niimi A, Ozeki K, Ueda M, Nakayama B. A comparative study of removal torque of endosseous implants in the fibula, iliac crest and scapula of cadavers: Preliminary report. Clin Oral Implants Res 1997;8:286-289.
    • (1997) Clin Oral Implants Res , vol.8 , pp. 286-289
    • Niimi, A.1    Ozeki, K.2    Ueda, M.3    Nakayama, B.4
  • 17
    • 0002332517 scopus 로고
    • Biology of fracture repair
    • Browner BD, Jupiter JB, Levine AM, Trafton PG (eds), Philadelphia:Saunders
    • Schenk RK. Biology of fracture repair. In: Browner BD, Jupiter JB, Levine AM, Trafton PG (eds). Skeletal Trauma. Philadelphia:Saunders, 1992:31-76.
    • (1992) Skeletal Trauma , pp. 31-76
    • Schenk, R.K.1
  • 18
    • 0021960062 scopus 로고
    • Bone remodeling in response to in vivo fatigue microdamage
    • Burr DB, Martin RB, Schaffler MB, Radin EL. Bone remodeling in response to in vivo fatigue microdamage. J Biomech 1985; 18:189-200.
    • (1985) J Biomech , vol.18 , pp. 189-200
    • Burr, D.B.1    Martin, R.B.2    Schaffler, M.B.3    Radin, E.L.4
  • 19
    • 0027462103 scopus 로고
    • Increased intracortical remodeling following fatigue damage
    • Mori S, Burr DB. Increased intracortical remodeling following fatigue damage. Bone 1993;14:103-109.
    • (1993) Bone , vol.14 , pp. 103-109
    • Mori, S.1    Burr, D.B.2
  • 21
    • 0023302919 scopus 로고
    • Integration of screw implants in the rabbit: A 1-year follow-up of removal torque of titanium implants
    • Johansson C, Albrektsson T. Integration of screw implants in the rabbit: A 1-year follow-up of removal torque of titanium implants. Int J Oral Maxillofac Implants 1987;2:69-75
    • (1987) Int J Oral Maxillofac Implants , vol.2 , pp. 69-75
    • Johansson, C.1    Albrektsson, T.2
  • 22
    • 0342601513 scopus 로고    scopus 로고
    • Biomechanical characterization of osseointegration during healing: An experimental in vivo study in the rat
    • Brånemark R, Ohrnell LO, Nilsson P, Thomsen P. Biomechanical characterization of osseointegration during healing: An experimental in vivo study in the rat. Biomaterials 1997;18:969-978.
    • (1997) Biomaterials , vol.18 , pp. 969-978
    • Brånemark, R.1    Ohrnell, L.O.2    Nilsson, P.3    Thomsen, P.4
  • 23
    • 0001047110 scopus 로고
    • The influence of various titanium surfaces on the interface shear strength between implants and bone
    • Heimke G, Soltesz U, Lee AJC (eds), Clinical Implant Materials:Proceedings of the Eighth European Conference on Biomaterials, Heidelberg, FRG, September 7-9,1989. Amsterdam:Elsevier Science
    • Wilke HJ, Claes L, Steinemann SG. The influence of various titanium surfaces on the interface shear strength between implants and bone. In: Heimke G, Soltesz U, Lee AJC (eds). Advance in Biomaterials, vol 9. Clinical Implant Materials:Proceedings of the Eighth European Conference on Biomaterials, Heidelberg, FRG, September 7-9,1989. Amsterdam:Elsevier Science, 1990:309-314.
    • (1990) Advance in Biomaterials , vol.9 , pp. 309-314
    • Wilke, H.J.1    Claes, L.2    Steinemann, S.G.3
  • 24
    • 0033196990 scopus 로고    scopus 로고
    • Rate of pull-out strength gain of dual-etched titanium implants: A comparative study in rabbits
    • Baker D, London RM, O’Neal R. Rate of pull-out strength gain of dual-etched titanium implants: A comparative study in rabbits. Int J Oral Maxillofac Implants 1999;14:722-728.
    • (1999) Int J Oral Maxillofac Implants , vol.14 , pp. 722-728
    • Baker, D.1    London, R.M.2    O’Neal, R.3
  • 26
    • 84995760324 scopus 로고    scopus 로고
    • Clinical outcome of tapered implants placed with high insertion torques (up to 176 Ncm) [abstract]
    • Khayat P, Arnal H, Tourbah B, Sennerby L. Clinical outcome of tapered implants placed with high insertion torques (up to 176 Ncm) [abstract]. Clin Oral Implants Res 2008;19:855.
    • (2008) Clin Oral Implants Res , vol.19 , pp. 855
    • Khayat, P.1    Arnal, H.2    Tourbah, B.3    Sennerby, L.4
  • 27
    • 37249059880 scopus 로고    scopus 로고
    • Comparative histomorphometry and resonance frequency analysis of implants with moderately rough surfaces in a loaded animal model
    • Al Nawas B, Groetz KA, Goetz H, Duschner H, Wagner W. Comparative histomorphometry and resonance frequency analysis of implants with moderately rough surfaces in a loaded animal model. Clin Oral Implants Res 2008;19:1-8.
    • (2008) Clin Oral Implants Res , vol.19 , pp. 1-8
    • Al Nawas, B.1    Groetz, K.A.2    Goetz, H.3    Duschner, H.4    Wagner, W.5
  • 28
    • 37249055018 scopus 로고    scopus 로고
    • Relevance of resonance frequency analysis to evaluate dental implant stability: Simulation and histomorphometrical animal experiments
    • Ito Y, Sato D, Yoneda S, Ito D, Kondo H, Kasugai S. Relevance of resonance frequency analysis to evaluate dental implant stability: Simulation and histomorphometrical animal experiments. Clin Oral Implants Res 2008;19:9-14.
    • (2008) Clin Oral Implants Res , vol.19 , pp. 9-14
    • Ito, Y.1    Sato, D.2    Yoneda, S.3    Ito, D.4    Kondo, H.5    Kasugai, S.6
  • 29
    • 0031152189 scopus 로고    scopus 로고
    • The application of resonance frequency measurements to study the stability of titanium implants during healing in the rabbit tibia
    • Meredith N, Shagaldi F, Alleyne D, Sennerby L, Cawley P. The application of resonance frequency measurements to study the stability of titanium implants during healing in the rabbit tibia. Clin Oral Implants Res 1997;8:234-243.
    • (1997) Clin Oral Implants Res , vol.8 , pp. 234-243
    • Meredith, N.1    Shagaldi, F.2    Alleyne, D.3    Sennerby, L.4    Cawley, P.5
  • 31
    • 0032151752 scopus 로고    scopus 로고
    • Assessment of implant stability as a prognostic determinant
    • Meredith N. Assessment of implant stability as a prognostic determinant. Int J Prosthodont 1998;11:491-501.
    • (1998) Int J Prosthodont , vol.11 , pp. 491-501
    • Meredith, N.1
  • 32
    • 0033302106 scopus 로고    scopus 로고
    • Implant stability measurements using resonance frequency analysis in the grafted maxilla: A cross-sectional pilot study
    • Rasmusson L, Stegersjo G, Kahnberg KE, Sennerby L. Implant stability measurements using resonance frequency analysis in the grafted maxilla: A cross-sectional pilot study. Clin Implant Dent Relat Res 1999;1:70-74
    • (1999) Clin Implant Dent Relat Res , vol.1 , pp. 70-74
    • Rasmusson, L.1    Stegersjo, G.2    Kahnberg, K.E.3    Sennerby, L.4
  • 33
    • 0141915197 scopus 로고    scopus 로고
    • Effects of various titanium surface configurations on osseointegration and clinical implant stability
    • Lang NP, Karring T, Lindhe J (eds), Berlin:Quintessenz
    • Buser D. Effects of various titanium surface configurations on osseointegration and clinical implant stability. In: Lang NP, Karring T, Lindhe J (eds). Proceedings of the 3rd European Workshop on Periodontology: Implant Dentistry. Berlin:Quintessenz, 1999:88-101.
    • (1999) Proceedings of the 3rd European Workshop on Periodontology: Implant Dentistry , pp. 88-101
    • Buser, D.1
  • 36
    • 0036987398 scopus 로고    scopus 로고
    • Stability measurements of osseointegrated implants using Osstell in partially edentulous jaws after 1 year of loading: A pilot study
    • Balleri P, Cozzolino A, Ghelli L, Momicchioli G, Varriale A. Stability measurements of osseointegrated implants using Osstell in partially edentulous jaws after 1 year of loading: A pilot study. Clin Implant Dent Relat Res 2002;4:128-132.
    • (2002) Clin Implant Dent Relat Res , vol.4 , pp. 128-132
    • Balleri, P.1    Cozzolino, A.2    Ghelli, L.3    Momicchioli, G.4    Varriale, A.5
  • 37
    • 0036618288 scopus 로고    scopus 로고
    • Resonance frequency and removal torque analysis of implants with turned and anodized surface oxides
    • Sul YT, Johansson CB, Jeong Y, Wennerberg A, Albrektsson T. Resonance frequency and removal torque analysis of implants with turned and anodized surface oxides. Clin Oral Implants Res 2002;13:252-259.
    • (2002) Clin Oral Implants Res , vol.13 , pp. 252-259
    • Sul, Y.T.1    Johansson, C.B.2    Jeong, Y.3    Wennerberg, A.4    Albrektsson, T.5
  • 38
    • 0031152189 scopus 로고    scopus 로고
    • The application of resonance frequency measurements to study the stability of titanium implants during healing in the rabbit tibia
    • Meredith N, Shagaldi F, Alleyne D, Sennerby L, Cawley P. The application of resonance frequency measurements to study the stability of titanium implants during healing in the rabbit tibia. Clin Oral Implants Res 1997;8:234-243.
    • (1997) Clin Oral Implants Res , vol.8 , pp. 234-243
    • Meredith, N.1    Shagaldi, F.2    Alleyne, D.3    Sennerby, L.4    Cawley, P.5
  • 39
    • 0035235831 scopus 로고    scopus 로고
    • Effects of implant design and surface on bone regeneration and implant stability: An experimental study in the dog mandible
    • Rasmusson L, Kahnberg KE, Tan A. Effects of implant design and surface on bone regeneration and implant stability: An experimental study in the dog mandible. Clin Implant Dent Relat Res 2001;3:2-8.
    • (2001) Clin Implant Dent Relat Res , vol.3 , pp. 2-8
    • Rasmusson, L.1    Kahnberg, K.E.2    Tan, A.3
  • 40
    • 34547700240 scopus 로고    scopus 로고
    • Clinical study on the primary stability of two dental implant systems with resonance frequency analysis
    • Rabel A, Kohler SG, Schmidt-Westhausen AM. Clinical study on the primary stability of two dental implant systems with resonance frequency analysis. Clin Oral Investig 2007;11:257-265.
    • (2007) Clin Oral Investig , vol.11 , pp. 257-265
    • Rabel, A.1    Kohler, S.G.2    Schmidt-Westhausen, A.M.3
  • 41
    • 0033176199 scopus 로고    scopus 로고
    • A comparison between cutting torque and resonance frequency measurements of maxillary implants. A 20-month clinical study
    • Friberg B, Sennerby L, Meredith N, Lekholm U. A comparison between cutting torque and resonance frequency measurements of maxillary implants. A 20-month clinical study. Int J Oral Maxillofac Surg 1999;28:297-303.
    • (1999) Int J Oral Maxillofac Surg , vol.28 , pp. 297-303
    • Friberg, B.1    Sennerby, L.2    Meredith, N.3    Lekholm, U.4
  • 42
    • 7744240100 scopus 로고    scopus 로고
    • Cutting torque measurements in conjunction with implant placement in grafted and nongrafted maxillas as an objective evaluation of bone density:A possible method for identifying early implant failures?
    • Johansson B, Back T, Hirsch JM. Cutting torque measurements in conjunction with implant placement in grafted and nongrafted maxillas as an objective evaluation of bone density:A possible method for identifying early implant failures? Clin Implant Dent Relat Res 2004;6:9-15.
    • (2004) Clin Implant Dent Relat Res , vol.6 , pp. 9-15
    • Johansson, B.1    Back, T.2    Hirsch, J.M.3
  • 43
    • 33746375362 scopus 로고    scopus 로고
    • Biomechanical aspects of initial intraosseous stability and implant design:A quantitative micro-morphometric analysis
    • Akca K, Chang TL, Tekdemir I, Fanuscu MI. Biomechanical aspects of initial intraosseous stability and implant design:A quantitative micro-morphometric analysis. Clin Oral Implants Res 2006;17:465-472.
    • (2006) Clin Oral Implants Res , vol.17 , pp. 465-472
    • Akca, K.1    Chang, T.L.2    Tekdemir, I.3    Fanuscu, M.I.4
  • 44
    • 0032135409 scopus 로고    scopus 로고
    • Bone healing capacity of titanium plasma-sprayed and hydroxylapatitecoated oral implants
    • Vercaigne S, Wolke JG, Naert I, Jansen JA. Bone healing capacity of titanium plasma-sprayed and hydroxylapatitecoated oral implants. Clin Oral Implants Res 1998;9:261-271.
    • (1998) Clin Oral Implants Res , vol.9 , pp. 261-271
    • Vercaigne, S.1    Wolke, J.G.2    Naert, I.3    Jansen, J.A.4
  • 45
    • 67650892092 scopus 로고    scopus 로고
    • Is insertion torque correlated to bone-implant contact percentage in the early healing period? A histological and histomorphometrical evaluation of 17 human-retrieved dental implants
    • Degidi M, Perrotti V, Strocchi R, Piattelli A, Iezzi G. Is insertion torque correlated to bone-implant contact percentage in the early healing period? A histological and histomorphometrical evaluation of 17 human-retrieved dental implants. Clin Oral Implants Res 2009;20:778-781.
    • (2009) Clin Oral Implants Res , vol.20 , pp. 778-781
    • Degidi, M.1    Perrotti, V.2    Strocchi, R.3    Piattelli, A.4    Iezzi, G.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.