-
1
-
-
0030982409
-
Simultaneous acquisition of spatial harmonics (SMASH): fast imaging with radiofrequency coil arrays
-
Sodickson D, Manning W,. Simultaneous acquisition of spatial harmonics (SMASH): fast imaging with radiofrequency coil arrays. Magn Reson Med 1997; 38: 591-603.
-
(1997)
Magn Reson Med
, vol.38
, pp. 591-603
-
-
Sodickson, D.1
Manning, W.2
-
2
-
-
0032712873
-
SENSE: sensitivity encoding for fast MRI
-
Pruessmann K, Weiger M, Scheidegger MB, Boesiger P,. SENSE: sensitivity encoding for fast MRI. Magn Reson Med 1999; 42.5: 952-962.
-
(1999)
Magn Reson Med
, vol.425
, pp. 952-962
-
-
Pruessmann, K.1
Weiger, M.2
Scheidegger, M.B.3
Boesiger, P.4
-
3
-
-
0036263907
-
Generalized autocalibrating partially parallel acquisitions (GRAPPA)
-
Griswold M, Jakob P, Heidemann RM, Nittka M, Jellus V, Wang J, Kiefer B, Haase A,. Generalized autocalibrating partially parallel acquisitions (GRAPPA). Magn Reson Imaging 2002; 47.6: 1202-1210.
-
(2002)
Magn Reson Imaging
, vol.476
, pp. 1202-1210
-
-
Griswold, M.1
Jakob, P.2
Heidemann, R.M.3
Nittka, M.4
Jellus, V.5
Wang, J.6
Kiefer, B.7
Haase, A.8
-
4
-
-
0035156514
-
Use of multicoil arrays for separation of signal from multiple slices simultaneously excited
-
Larkman D, Hajnal J, Herlihy AH, Coutts GA, Young IR, Ehnholm G,. Use of multicoil arrays for separation of signal from multiple slices simultaneously excited. J Magn Reson Imaging 2001; 13: 313-317.
-
(2001)
J Magn Reson Imaging
, vol.13
, pp. 313-317
-
-
Larkman, D.1
Hajnal, J.2
Herlihy, A.H.3
Coutts, G.A.4
Young, I.R.5
Ehnholm, G.6
-
5
-
-
77955292827
-
Multiband multislice GE-EPI at 7 tesla, with 16-fold acceleration using partial parallel imaging with application to high spatial and temporal whole-brain fMRI
-
Moeller S, Yacoub E, Olman CA, Auerbach E, Strupp J, Harel N, Uʇurbil K,. Multiband multislice GE-EPI at 7 tesla, with 16-fold acceleration using partial parallel imaging with application to high spatial and temporal whole-brain fMRI. Magn Reson Med 2010; 63: 1144-1153.
-
(2010)
Magn Reson Med
, vol.63
, pp. 1144-1153
-
-
Moeller, S.1
Yacoub, E.2
Olman, C.A.3
Auerbach, E.4
Strupp, J.5
Harel, N.6
Uʇurbil, K.7
-
6
-
-
78650982393
-
Multiplexed echo planar imaging for sub-second whole brain FMRI and fast diffusion imaging
-
Feinberg D, Moeller S, Smith S, Auerbach E, Ramanna S, Glasser MF, Miller K, Uʇurbil K, Yacoub E,. Multiplexed echo planar imaging for sub-second whole brain FMRI and fast diffusion imaging. PLoS One 2010; 5: e15710.
-
(2010)
PLoS One
, vol.5
-
-
Feinberg, D.1
Moeller, S.2
Smith, S.3
Auerbach, E.4
Ramanna, S.5
Glasser, M.F.6
Miller, K.7
Uʇurbil, K.8
Yacoub, E.9
-
7
-
-
14744304684
-
Controlled aliasing in parallel imaging results in higher acceleration (CAIPIRINHA) for multi-slice imaging
-
Breuer F, Blaimer M, Heidemann RM, Mueller MF, Griswold MA, Jakob PM,. Controlled aliasing in parallel imaging results in higher acceleration (CAIPIRINHA) for multi-slice imaging. Magn Reson Med 2005; 53: 684-691.
-
(2005)
Magn Reson Med
, vol.53
, pp. 684-691
-
-
Breuer, F.1
Blaimer, M.2
Heidemann, R.M.3
Mueller, M.F.4
Griswold, M.A.5
Jakob, P.M.6
-
8
-
-
80054818311
-
Power independent of number of slices (PINS) radiofrequency pulses for low-power simultaneous multislice excitation
-
Norris D, Koopmans PJ, Boyacioʇlu R, Barth M,. Power independent of number of slices (PINS) radiofrequency pulses for low-power simultaneous multislice excitation. Magn Reson Med 2011; 66: 1234-1240.
-
(2011)
Magn Reson Med
, vol.66
, pp. 1234-1240
-
-
Norris, D.1
Koopmans, P.J.2
Boyacioʇlu, R.3
Barth, M.4
-
9
-
-
84890799962
-
Application of PINS radiofrequency pulses to reduce power deposition in RARE/turbo spin echo imaging of the human head
-
Norris D, Boyacioʇlu R, Schulz J, Barth M, Koopmans PJ,. Application of PINS radiofrequency pulses to reduce power deposition in RARE/turbo spin echo imaging of the human head. Magn Reson Med 2014; 71: 44-49.
-
(2014)
Magn Reson Med
, vol.71
, pp. 44-49
-
-
Norris, D.1
Boyacioʇlu, R.2
Schulz, J.3
Barth, M.4
Koopmans, P.J.5
-
10
-
-
79954440483
-
CAIPIRINHA accelerated SSFP imaging
-
Stäb D, Ritter C, Breuer F, Weng AM, Hahn D, Köstler H,. CAIPIRINHA accelerated SSFP imaging. Magn Reson Med 2011; 65: 157-164.
-
(2011)
Magn Reson Med
, vol.65
, pp. 157-164
-
-
Stäb, D.1
Ritter, C.2
Breuer, F.3
Weng, A.M.4
Hahn, D.5
Köstler, H.6
-
11
-
-
84859705233
-
Blipped-controlled aliasing in parallel imaging for simultaneous multislice echo planar imaging with reduced g-factor penalty
-
Setsompop K, Gagoski B, Polimeni JR, Witzel T, Wedeen VJ, Wald LL,. Blipped-controlled aliasing in parallel imaging for simultaneous multislice echo planar imaging with reduced g-factor penalty. Magn Reson Med 2012; 67: 1210-1224.
-
(2012)
Magn Reson Med
, vol.67
, pp. 1210-1224
-
-
Setsompop, K.1
Gagoski, B.2
Polimeni, J.R.3
Witzel, T.4
Wedeen, V.J.5
Wald, L.L.6
-
12
-
-
84865413556
-
Improving diffusion MRI using simultaneous multi-slice echo planar imaging
-
Setsompop K, Cohen-Adad J, Gagoski B, Raij T, Yendiki A, Keil B, Wedeen VJ, Wald LL,. Improving diffusion MRI using simultaneous multi-slice echo planar imaging. Neuroimage 2012; 63: 569-580.
-
(2012)
Neuroimage
, vol.63
, pp. 569-580
-
-
Setsompop, K.1
Cohen-Adad, J.2
Gagoski, B.3
Raij, T.4
Yendiki, A.5
Keil, B.6
Wedeen, V.J.7
Wald, L.L.8
-
13
-
-
84887995851
-
Arterial spin labeling with simultaneous multi-slice echo planar imaging
-
Feinberg D, Beckett A, Chen L,. Arterial spin labeling with simultaneous multi-slice echo planar imaging. Magn Reson Med 2013; 70: 1500-1506.
-
(2013)
Magn Reson Med
, vol.70
, pp. 1500-1506
-
-
Feinberg, D.1
Beckett, A.2
Chen, L.3
-
14
-
-
84887988512
-
Whole brain perfusion measurements using arterial spin labeling with multiband acquisition
-
Kim T, Shin W, Zhao T, Beall EB, Lowe MJ, Bae KT,. Whole brain perfusion measurements using arterial spin labeling with multiband acquisition. Magn Reson Med 2013; 70: 1653-1661.
-
(2013)
Magn Reson Med
, vol.70
, pp. 1653-1661
-
-
Kim, T.1
Shin, W.2
Zhao, T.3
Beall, E.B.4
Lowe, M.J.5
Bae, K.T.6
-
15
-
-
85027925114
-
Slice accelerated gradient-echo spin-echo dynamic susceptibility contrast imaging with blipped CAIPI for increased slice coverage
-
Eichner C, Jafari-Khouzani K, Cauley S, et al., Slice accelerated gradient-echo spin-echo dynamic susceptibility contrast imaging with blipped CAIPI for increased slice coverage. Magn Reson Med 2013. doi: 10.1002/mrm.24960.
-
(2013)
1Magn Reson Med
-
-
Eichner, C.1
Jafari-Khouzani, K.2
Cauley, S.3
-
16
-
-
33644812347
-
Controlled aliasing in volumetric parallel imaging (2D CAIPIRINHA)
-
Breuer F, Blaimer M, Mueller MF, Seiberlich N, Heidemann RM, Griswold MA, Jakob PM,. Controlled aliasing in volumetric parallel imaging (2D CAIPIRINHA). Magn Reson Med 2006; 55.3: 549-556.
-
(2006)
Magn Reson Med
, vol.553
, pp. 549-556
-
-
Breuer, F.1
Blaimer, M.2
Mueller, M.F.3
Seiberlich, N.4
Heidemann, R.M.5
Griswold, M.A.6
Jakob, P.M.7
-
17
-
-
84875369285
-
Autocalibrating CAIPIRINHA: reformulating CAIPIRINHA as a 3D problem
-
Melbourne, Australia
-
Zhu K, Kerr A, Pauly J,. Autocalibrating CAIPIRINHA: reformulating CAIPIRINHA as a 3D problem. In Proceedings of the 20th Annual Meeting of ISMRM, Melbourne, Australia, 2012. p. 518.
-
(2012)
Proceedings of the 20th Annual Meeting of ISMRM
, pp. 518
-
-
Zhu, K.1
Kerr, A.2
Pauly, J.3
-
18
-
-
84900796823
-
Three-dimensional Fourier encoding of simultaneously excited slices: generalized acquisition and reconstruction framework
-
Zahneisen B, Poser BA, Ernst T, Stenger VA,. Three-dimensional Fourier encoding of simultaneously excited slices: generalized acquisition and reconstruction framework. Magn. Reson Med 2014; 71: 2071-2081.
-
(2014)
Magn. Reson Med
, vol.71
, pp. 2071-2081
-
-
Zahneisen, B.1
Poser, B.A.2
Ernst, T.3
Stenger, V.A.4
-
19
-
-
33644800462
-
Bunched phase encoding (BPE): a new fast data acquisition method in MRI
-
Moriguchi H, Duerk J,. Bunched phase encoding (BPE): a new fast data acquisition method in MRI. Magn Reson Med 2006; 55.3: 633-648.
-
(2006)
Magn Reson Med
, vol.553
, pp. 633-648
-
-
Moriguchi, H.1
Duerk, J.2
-
20
-
-
62649120885
-
Using the GRAPPA operator and the generalized sampling theorem to reconstruct undersampled non-Cartesian data
-
Seiberlich N, Breuer F, Ehses P, Moriguchi H, Blaimer M, Jakob PM, Griswold MA,. Using the GRAPPA operator and the generalized sampling theorem to reconstruct undersampled non-Cartesian data. Magn Reson Med 2009; 61.3: 705-715.
-
(2009)
Magn Reson Med
, vol.613
, pp. 705-715
-
-
Seiberlich, N.1
Breuer, F.2
Ehses, P.3
Moriguchi, H.4
Blaimer, M.5
Jakob, P.M.6
Griswold, M.A.7
-
21
-
-
33644813019
-
Further scan time reduction of bunched phase encoding using sensitivity encoding
-
Miami Beach, Florida, USA
-
Moriguchi H, Sunshine J, Duerk J,. Further scan time reduction of bunched phase encoding using sensitivity encoding. In Proceedings of the 13th Annual Meeting of ISMRM, Miami Beach, Florida, USA, 2005. p. 287
-
(2005)
Proceedings of the 13th Annual Meeting of ISMRM
, pp. 287
-
-
Moriguchi, H.1
Sunshine, J.2
Duerk, J.3
-
22
-
-
49049120688
-
Zigzag sampling for improved parallel imaging
-
Breuer F, Moriguchi H, Seiberlich N, Blaimer M, Jakob PM, Duerk JL, Griswold MA,. Zigzag sampling for improved parallel imaging. Magn Reson Med 2008; 60.2: 474-478.
-
(2008)
Magn Reson Med
, vol.602
, pp. 474-478
-
-
Breuer, F.1
Moriguchi, H.2
Seiberlich, N.3
Blaimer, M.4
Jakob, P.M.5
Duerk, J.L.6
Griswold, M.A.7
-
23
-
-
77955102061
-
SPIRiT: iterative self consistent parallel imaging reconstruction from arbitrary k space
-
Lustig M, Pauly J,. SPIRiT: iterative self consistent parallel imaging reconstruction from arbitrary k space. Magn Reson Med 2010; 64: 457-471.
-
(2010)
Magn Reson Med
, vol.64
, pp. 457-471
-
-
Lustig, M.1
Pauly, J.2
-
24
-
-
84866740085
-
Denoising sparse images from GRAPPA using the nullspace method
-
Weller D, Polimeni J, Grady L, Wald LL, Adalsteinsson E, Goyal VK,. Denoising sparse images from GRAPPA using the nullspace method. Magn Reson Med 2012; 68: 1176-1189.
-
(2012)
Magn Reson Med
, vol.68
, pp. 1176-1189
-
-
Weller, D.1
Polimeni, J.2
Grady, L.3
Wald, L.L.4
Adalsteinsson, E.5
Goyal, V.K.6
-
25
-
-
77955586915
-
Combination of compressed sensing and parallel imaging for highly accelerated first pass cardiac perfusion MRI
-
Otazo R, Kim D, Axel J, Sodickson. DK,. Combination of compressed sensing and parallel imaging for highly accelerated first pass cardiac perfusion MRI. Magn Reson Med 2010; 64.3: 767-776.
-
(2010)
Magn Reson Med
, vol.643
, pp. 767-776
-
-
Otazo, R.1
Kim, D.2
Axel, J.3
Sodickson, D.K.4
-
26
-
-
73149123165
-
Accelerating SENSE using compressed sensing
-
Liang D, Liu B, Wang J, Ying L,. Accelerating SENSE using compressed sensing. Magn Reson Med 2009; 62.6: 1574-1584.
-
(2009)
Magn Reson Med
, vol.626
, pp. 1574-1584
-
-
Liang, D.1
Liu, B.2
Wang, J.3
Ying, L.4
-
27
-
-
84875230943
-
Wave-CAIPIRINHA: A Method for Reducing g-Factors in Highly Acclerated 3D Acquisitions
-
Motreal, Quebec, Canada
-
Setsompop K, Gagoski B, Polimeni J, Wald L,. Wave-CAIPIRINHA: A Method for Reducing g-Factors in Highly Acclerated 3D Acquisitions. In Proceedings of the 20th Annual Meeting of ISMRM, Motreal, Quebec, Canada, 2011. p. 478.
-
(2011)
Proceedings of the 20th Annual Meeting of ISMRM
, pp. 478
-
-
Setsompop, K.1
Gagoski, B.2
Polimeni, J.3
Wald, L.4
-
28
-
-
0034794323
-
Advances in sensitivity encoding with arbitrary k-space trajectories
-
Pruessmann K, Weiger M, M., Börnert P, Boesiger P., Advances in sensitivity encoding with arbitrary k-space trajectories. Magn Reson Med 2001; 46: 638-651.
-
(2001)
Magn Reson Med
, vol.46
, pp. 638-651
-
-
Pruessmann, K.1
Weiger, M.M.2
Börnert, P.3
Boesiger, P.4
-
29
-
-
84868524848
-
Fiber orientation-dependent white matter contrast in gradient echo MRI
-
Wharton S, Bowtell R,. Fiber orientation-dependent white matter contrast in gradient echo MRI. Proc Natl Acad Sci U S A 2012; 109: 18559-18564.
-
(2012)
Proc Natl Acad Sci U S A
, vol.109
, pp. 18559-18564
-
-
Wharton, S.1
Bowtell, R.2
-
30
-
-
4243162030
-
Susceptibility weighted imaging (SWI)
-
Haacke E, Xu Y, Cheng YCN, Reichenbach JR,. Susceptibility weighted imaging (SWI). Magn Reson Med 2004; 52: 612-618.
-
(2004)
Magn Reson Med
, vol.52
, pp. 612-618
-
-
Haacke, E.1
Xu, Y.2
Cheng, Y.C.N.3
Reichenbach, J.R.4
-
31
-
-
77956305947
-
Susceptibility mapping as a means to visualize veins and quantify oxygen saturation
-
Haacke E, Tang J, Neelavalli J, Cheng Y,. Susceptibility mapping as a means to visualize veins and quantify oxygen saturation. J Magn Reson Imaging 2010; 32: 663-676.
-
(2010)
J Magn Reson Imaging
, vol.32
, pp. 663-676
-
-
Haacke, E.1
Tang, J.2
Neelavalli, J.3
Cheng, Y.4
-
32
-
-
73349121926
-
Quantitative susceptibility map reconstruction from MR phase data using bayesian regularization: validation and application to brain imaging
-
De Rochefort L, Liu T, Kressler B, Liu J, Spincemaille P, Lebon V, Wu J, Wang Y,. Quantitative susceptibility map reconstruction from MR phase data using bayesian regularization: validation and application to brain imaging. Magn Reson Med 2010; 63: 194-206.
-
(2010)
Magn Reson Med
, vol.63
, pp. 194-206
-
-
De Rochefort, L.1
Liu, T.2
Kressler, B.3
Liu, J.4
Spincemaille, P.5
Lebon, V.6
Wu, J.7
Wang, Y.8
-
33
-
-
78650953898
-
Quantitative imaging of intrinsic magnetic tissue properties using MRI signal phase: an approach to in vivo brain iron metabolism?
-
Schweser F, Deistung A, Lehr BW, Reichenbach JR,. Quantitative imaging of intrinsic magnetic tissue properties using MRI signal phase: an approach to in vivo brain iron metabolism? Neuroimage 2011; 54: 2789-807.
-
(2011)
Neuroimage
, vol.54
, pp. 2789-2807
-
-
Schweser, F.1
Deistung, A.2
Lehr, B.W.3
Reichenbach, J.R.4
-
34
-
-
80051676166
-
Morphology enabled dipole inversion (MEDI) from a single-angle acquisition: comparison with COSMOS in human brain imaging
-
Liu T, Liu J, de Rochefort L, Spincemaille P, Khalidov I, Ledoux JR, Wang Y,. Morphology enabled dipole inversion (MEDI) from a single-angle acquisition: comparison with COSMOS in human brain imaging. Magn Reson Med 2011; 66: 777-783.
-
(2011)
Magn Reson Med
, vol.66
, pp. 777-783
-
-
Liu, T.1
Liu, J.2
De Rochefort, L.3
Spincemaille, P.4
Khalidov, I.5
Ledoux, J.R.6
Wang, Y.7
-
35
-
-
0025034429
-
Three-dimensional magnetization-prepared rapid gradient-echo imaging (3D MP RAGE)
-
Mugler J, Brookeman J,. Three-dimensional magnetization-prepared rapid gradient-echo imaging (3D MP RAGE). Magn Reson Med 1990; 15: 152-157.
-
(1990)
Magn Reson Med
, vol.15
, pp. 152-157
-
-
Mugler, J.1
Brookeman, J.2
-
36
-
-
84855463623
-
Magnetic susceptibility anisotropy of human brain in vivo and its molecular underpinnings
-
Li W, Wu B, Avram AV, Liu C,. Magnetic susceptibility anisotropy of human brain in vivo and its molecular underpinnings. Neuroimage 2012; 59: 2088-2097.
-
(2012)
Neuroimage
, vol.59
, pp. 2088-2097
-
-
Li, W.1
Wu, B.2
Avram, A.V.3
Liu, C.4
-
37
-
-
84355161789
-
Whole brain susceptibility mapping using compressed sensing
-
Wu B, Li W, Guidon A, Liu C,. Whole brain susceptibility mapping using compressed sensing. Magn Reson Med 2012; 67: 137-147.
-
(2012)
Magn Reson Med
, vol.67
, pp. 137-147
-
-
Wu, B.1
Li, W.2
Guidon, A.3
Liu, C.4
-
38
-
-
84907954001
-
Adalsteinsson E, Wald LL, Setsompop K. Fast quantitative susceptibility mapping with L1 regularization and automatic parameter selection
-
Bilgic B, Fan A, Polimeni JR, Cauley SF, Bianciardi M, Adalsteinsson E, Wald LL, Setsompop K. Fast quantitative susceptibility mapping with L1 regularization and automatic parameter selection. Magn Reson Med 2014; 72: 1444-1459.
-
(2014)
Magn Reson Med
, vol.72
, pp. 1444-1459
-
-
Bilgic, B.1
Fan, A.2
Polimeni, J.R.3
Cauley, S.F.4
Bianciardi, M.5
-
40
-
-
0032059889
-
Simple correction method for k-space trajectory deviations in MRI
-
Duyn J, Yang Y, Frank J, van der Veen J,. Simple correction method for k-space trajectory deviations in MRI. J Magn Reson 1998; 132: 150-153.
-
(1998)
J Magn Reson
, vol.132
, pp. 150-153
-
-
Duyn, J.1
Yang, Y.2
Frank, J.3
Van Der Veen, J.4
-
41
-
-
34250364567
-
Joint image reconstruction and sensitivity estimation in SENSE (JSENSE)
-
Ying L, Sheng J,. Joint image reconstruction and sensitivity estimation in SENSE (JSENSE). Magn Reson Med 2007; 57: 1196-1202.
-
(2007)
Magn Reson Med
, vol.57
, pp. 1196-1202
-
-
Ying, L.1
Sheng, J.2
-
42
-
-
79956216640
-
Design optimization of a 32-channel head coil at 7 T
-
Stockholm, Sweden
-
Keil B, Triantafyllou C, Hamm M, Wald LL,. Design optimization of a 32-channel head coil at 7 T. In Proceedings of the 18th Annual Meeting of ISMRM, Stockholm, Sweden, 2010. p. 1493
-
(2010)
Proceedings of the 18th Annual Meeting of ISMRM
, pp. 1493
-
-
Keil, B.1
Triantafyllou, C.2
Hamm, M.3
Wald, L.L.4
-
43
-
-
0036828879
-
Fast robust automated brain extraction
-
Smith S,. Fast robust automated brain extraction. Hum Brain Mapp 2002; 17: 143-155.
-
(2002)
Hum Brain Mapp
, vol.17
, pp. 143-155
-
-
Smith, S.1
-
44
-
-
20144364751
-
Application of a Fourier-based method for rapid calculation of field inhomogeneity due to spatial variation of magnetic susceptibility
-
Marques JP, Bowtell R,. Application of a Fourier-based method for rapid calculation of field inhomogeneity due to spatial variation of magnetic susceptibility. Concepts Magn Reson Part B Magn Reson Eng 2005; 25B: 65-78.
-
(2005)
Concepts Magn Reson Part B Magn Reson Eng
, vol.25 B
, pp. 65-78
-
-
Marques, J.P.1
Bowtell, R.2
-
45
-
-
84855422550
-
Morphology enabled dipole inversion for quantitative susceptibility mapping using structural consistency between the magnitude image and the susceptibility map
-
Liu J, Liu T, de Rochefort L, et al., Morphology enabled dipole inversion for quantitative susceptibility mapping using structural consistency between the magnitude image and the susceptibility map. Neuroimage 2012; 59: 2560-2568.
-
(2012)
Neuroimage
, vol.59
, pp. 2560-2568
-
-
Liu, J.1
Liu, T.2
De Rochefort, L.3
-
46
-
-
60349091024
-
Calculation of susceptibility through multiple orientation sampling (COSMOS): a method for conditioning the inverse problem from measured magnetic field map to susceptibility source image in MRI
-
Liu T, Spincemaille P, de Rochefort L, Kressler B, Wang Y,. Calculation of susceptibility through multiple orientation sampling (COSMOS): a method for conditioning the inverse problem from measured magnetic field map to susceptibility source image in MRI. Magn Reson Med 2009; 61: 196-204.
-
(2009)
Magn Reson Med
, vol.61
, pp. 196-204
-
-
Liu, T.1
Spincemaille, P.2
De Rochefort, L.3
Kressler, B.4
Wang, Y.5
-
47
-
-
84902366194
-
Fast image reconstruction with L2-regularization
-
Bilgic B, Chatnuntawech I, Fan AP, Setsompop K, Cauley SF, Wald LL, Adalsteinsson E,. Fast image reconstruction with L2-regularization. J Magn Reson Imaging 2014; 40: 181-191.
-
(2014)
J Magn Reson Imaging
, vol.40
, pp. 181-191
-
-
Bilgic, B.1
Chatnuntawech, I.2
Fan, A.P.3
Setsompop, K.4
Cauley, S.F.5
Wald, L.L.6
Adalsteinsson, E.7
-
48
-
-
0023691906
-
Simultaneous multislice acquisition of MR images
-
Weaver J,. Simultaneous multislice acquisition of MR images. Magn Reson Med 1988; 8: 275-284.
-
(1988)
Magn Reson Med
, vol.8
, pp. 275-284
-
-
Weaver, J.1
-
49
-
-
77952738897
-
Susceptibility tensor imaging
-
Liu C,. Susceptibility tensor imaging. Magn Reson Med 2010; 63: 1471-1477.
-
(2010)
Magn Reson Med
, vol.63
, pp. 1471-1477
-
-
Liu, C.1
-
50
-
-
0034821969
-
Suppression of cerebrospinal fluid and blood flow artifacts in FLAIR MR imaging with a single-slab three-dimensional pulse sequence: initial experience 1
-
Kallmes D, Hui F, Mugler J,. Suppression of cerebrospinal fluid and blood flow artifacts in FLAIR MR imaging with a single-slab three-dimensional pulse sequence: initial experience 1. Radiology 2001; 221: 251-255.
-
(2001)
Radiology
, vol.221
, pp. 251-255
-
-
Kallmes, D.1
Hui, F.2
Mugler, J.3
-
51
-
-
77950543769
-
Three dimensional echo-planar imaging at 7 Tesla
-
Poser B, Koopmans P, Witzel T, Wald L, Barth M,. Three dimensional echo-planar imaging at 7 Tesla. Neuroimage 2010; 51: 261-266.
-
(2010)
Neuroimage
, vol.51
, pp. 261-266
-
-
Poser, B.1
Koopmans, P.2
Witzel, T.3
Wald, L.4
Barth, M.5
-
52
-
-
22744443729
-
Single-shot 3D imaging techniques improve arterial spin labeling perfusion measurements
-
Günther M, Oshio K, Feinberg D,. Single-shot 3D imaging techniques improve arterial spin labeling perfusion measurements. Magn Reson 2005; 54: 491-498.
-
(2005)
Magn Reson
, vol.54
, pp. 491-498
-
-
Günther, M.1
Oshio, K.2
Feinberg, D.3
-
53
-
-
0022214476
-
Inner volume MR imaging: technical concepts and their application
-
Feinberg D, Hoenninger J, Crooks L, Kaufman L, Watts JC, Arakawa. M,. Inner volume MR imaging: technical concepts and their application. Radiology 1985; 156: 743-747.
-
(1985)
Radiology
, vol.156
, pp. 743-747
-
-
Feinberg, D.1
Hoenninger, J.2
Crooks, L.3
Kaufman, L.4
Watts, J.C.5
Arakawa, M.6
|