-
1
-
-
0033772492
-
Partially parallel imaging with localized sensitivities (PILS)
-
Griswold MA, Jakob PM, Nittka M, Goldfarb JW, Haase A. Partially parallel imaging with localized sensitivities (PILS). Magn Reson Med 2000;44:602-609.
-
(2000)
Magn Reson Med
, vol.44
, pp. 602-609
-
-
Griswold, M.A.1
Jakob, P.M.2
Nittka, M.3
Goldfarb, J.W.4
Haase, A.5
-
4
-
-
0036263907
-
Generalized autocalibrating partially parallel acquisitions (GRAPPA)
-
Griswold MA, Jakob PM, Heidemann RM, Mathias Nittka, Jellus V, Wang J, Kiefer B, Haase A. Generalized autocalibrating partially parallel acquisitions (GRAPPA). Magn Reson Med 2002;47:1202-1210.
-
(2002)
Magn Reson Med
, vol.47
, pp. 1202-1210
-
-
Griswold, M.A.1
Jakob, P.M.2
Heidemann, R.M.3
Nittka, M.4
Jellus, V.5
Wang, J.6
Kiefer, B.7
Haase, A.8
-
5
-
-
0030982409
-
Simultaneous acquisition of spatial harmonics (SMASH): Fast imaging with radiofrequency coil arrays
-
Sodickson DK, Manning WJ. Simultaneous acquisition of spatial harmonics (SMASH): fast imaging with radiofrequency coil arrays. Magn Reson Med 1997;38:591-603.
-
(1997)
Magn Reson Med
, vol.38
, pp. 591-603
-
-
Sodickson, D.K.1
Manning, W.J.2
-
7
-
-
0033854213
-
Sensitivity profiles from an array of coils for encoding and reconstruction in parallel (SPACE RIP)
-
Kyriakos WE, Panych LP, Kacher DF, Westin C-F, Bao SM, Mulkern RV, Jolesz FA. Sensitivity profiles from an array of coils for encoding and reconstruction in parallel (SPACE RIP). Magn Reson Med 2000;44:301-308.
-
(2000)
Magn Reson Med
, vol.44
, pp. 301-308
-
-
Kyriakos, W.E.1
Panych, L.P.2
Kacher, D.F.3
Westin, C.-F.4
Bao, S.M.5
Mulkern, R.V.6
Jolesz, F.A.7
-
8
-
-
0036188010
-
Self-calibrating parallel imaging with automatic coil sensitivity extraction
-
McKenzie CA, Yeh EN, Ohliger MA, Price MD, Sodickson DK. Self-calibrating parallel imaging with automatic coil sensitivity extraction. Magn Reson Med 2002;47:529-538.
-
(2002)
Magn Reson Med
, vol.47
, pp. 529-538
-
-
McKenzie, C.A.1
Yeh, E.N.2
Ohliger, M.A.3
Price, M.D.4
Sodickson, D.K.5
-
9
-
-
0035032781
-
Adaptive sensitivity encoding incorporating temporal filtering (TSENSE)
-
Kellman P, Epstein FH, McVeigh ER. Adaptive sensitivity encoding incorporating temporal filtering (TSENSE). Magn Reson Med 2001;45:846-852.
-
(2001)
Magn Reson Med
, vol.45
, pp. 846-852
-
-
Kellman, P.1
Epstein, F.H.2
McVeigh, E.R.3
-
10
-
-
3543128963
-
UNFOLD-SENSE: A parallel MRI method with self-calibration and artifact suppression
-
Madore B. UNFOLD-SENSE: a parallel MRI method with self-calibration and artifact suppression. Magn Reson Med 2004;52:310-320.
-
(2004)
Magn Reson Med
, vol.52
, pp. 310-320
-
-
Madore, B.1
-
11
-
-
0032751897
-
Unaliasing by Fourier-encoding the overlaps using the temporal dimension (UNFOLD) applied to cardiac imaging and fMRI
-
Madore B, Glover GH, Pelc NJ. Unaliasing by Fourier-encoding the overlaps using the temporal dimension (UNFOLD) applied to cardiac imaging and fMRI. Magn Reson Med 1999;42:813-828.
-
(1999)
Magn Reson Med
, vol.42
, pp. 813-828
-
-
Madore, B.1
Glover, G.H.2
Pelc, N.J.3
-
14
-
-
0037904043
-
A wavelet-based approximation of surface coil sensitivity profiles for correction of image intensity inhomogeneity and parallel imaging reconstruction
-
Lin F-H, Chen Y-J, Belliveau JW, Wald LL. A wavelet-based approximation of surface coil sensitivity profiles for correction of image intensity inhomogeneity and parallel imaging reconstruction. Hum Brain Mapp 2003;19:96-111.
-
(2003)
Hum Brain Mapp
, vol.19
, pp. 96-111
-
-
Lin, F.-H.1
Chen, Y.-J.2
Belliveau, J.W.3
Wald, L.L.4
-
15
-
-
0034794323
-
Advances in sensitivity encoding with arbitrary k-space trajectories
-
Pruessmann KP, Weiger M, Böernert P. Advances in sensitivity encoding with arbitrary k-space trajectories. Magn Reson Med 2001;46:638-651.
-
(2001)
Magn Reson Med
, vol.46
, pp. 638-651
-
-
Pruessmann, K.P.1
Weiger, M.2
Böernert, P.3
-
16
-
-
2942755647
-
Dynamic field map estimation using a spiral-in/spiral-out acquisition
-
Sutton BP, Noll DC, Fessler JA. Dynamic field map estimation using a spiral-in/spiral-out acquisition. Magn Reson Imaging 2004;51:1194-1204.
-
(2004)
Magn Reson Imaging
, vol.51
, pp. 1194-1204
-
-
Sutton, B.P.1
Noll, D.C.2
Fessler, J.A.3
-
17
-
-
10044289695
-
POCSENSE: POCS-based reconstruction method for sensitivity encoded magnetic resonance imaging
-
Samsonov AA, Kholmovski EG, Parker DL, Johnson CR. POCSENSE: POCS-based reconstruction method for sensitivity encoded magnetic resonance imaging. Magn Reson Med 2004;52:1397-1406.
-
(2004)
Magn Reson Med
, vol.52
, pp. 1397-1406
-
-
Samsonov, A.A.1
Kholmovski, E.G.2
Parker, D.L.3
Johnson, C.R.4
-
18
-
-
11144352758
-
On Tikhonov regularization for image reconstruction in parallel MRI
-
San Francisco, CA, USA
-
Ying L, Xu D, Liang Z-P. On Tikhonov regularization for image reconstruction in parallel MRI. In: Proceedings of the 26th Annual International Conference of IEEE EMBS, San Francisco, CA, USA, 2004. p 1056-1059.
-
(2004)
Proceedings of the 26th Annual International Conference of IEEE EMBS
, pp. 1056-1059
-
-
Ying, L.1
Xu, D.2
Liang, Z.-P.3
-
19
-
-
34248152020
-
Efficient variable density SENSE reconstruction
-
Miami Beach, FL, USA, Abstract 2418
-
King KF. Efficient variable density SENSE reconstruction. In: Proceedings of the 13th Annual Meeting of ISMRM, Miami Beach, FL, USA, 2005 (Abstract 2418).
-
(2005)
Proceedings of the 13th Annual Meeting of ISMRM
-
-
King, K.F.1
-
20
-
-
34250355786
-
Optimizing SENSE for dynamic imaging
-
Miami Beach, FL, USA, Abstract 2419
-
Xu D, Ying L, Jacob M, Liang Z-P. Optimizing SENSE for dynamic imaging. In: Proceedings of the 13th Annual Meeting of ISMRM, Miami Beach, FL, USA, 2005 (Abstract 2419).
-
(2005)
Proceedings of the 13th Annual Meeting of ISMRM
-
-
Xu, D.1
Ying, L.2
Jacob, M.3
Liang, Z.-P.4
|