-
1
-
-
0026508892
-
Perfusion imaging
-
Detre JA, Leigh JS, Williams DS, Koretsky AP,. Perfusion imaging. Magn Reson Med 1992; 23: 37-45.
-
(1992)
Magn Reson Med
, vol.23
, pp. 37-45
-
-
Detre, J.A.1
Leigh, J.S.2
Williams, D.S.3
Koretsky, A.P.4
-
2
-
-
0031966050
-
Quantitative imaging of perfusion using a single subtraction (QUIPSS and QUIPSS II)
-
Wong EC, Buxton RB, Frank LR,. Quantitative imaging of perfusion using a single subtraction (QUIPSS and QUIPSS II). Magn Reson Med 1998; 39: 702-708.
-
(1998)
Magn Reson Med
, vol.39
, pp. 702-708
-
-
Wong, E.C.1
Buxton, R.B.2
Frank, L.R.3
-
3
-
-
77957314670
-
Modified pulsed continuous arterial spin labeling for labeling of a single artery
-
Dai W, Robson PM, Shankaranarayanan A, Alsop DC,. Modified pulsed continuous arterial spin labeling for labeling of a single artery. Magn Reson Med 2010; 64: 975-982.
-
(2010)
Magn Reson Med
, vol.64
, pp. 975-982
-
-
Dai, W.1
Robson, P.M.2
Shankaranarayanan, A.3
Alsop, D.C.4
-
4
-
-
22744443729
-
Single-shot 3D imaging techniques improve arterial spin labeling perfusion measurements
-
Gunther M, Oshio K, Feinberg DA,. Single-shot 3D imaging techniques improve arterial spin labeling perfusion measurements. Magn Reson Med 2005; 54: 491-498.
-
(2005)
Magn Reson Med
, vol.54
, pp. 491-498
-
-
Gunther, M.1
Oshio, K.2
Feinberg, D.A.3
-
5
-
-
27644542697
-
Continuous arterial spin labeling perfusion measurements using single shot 3D GRASE at 3 T
-
Fernandez-Seara MA, Wang Z, Wang J, Rao HY, Guenther M, Feinberg DA, Detre JA,. Continuous arterial spin labeling perfusion measurements using single shot 3D GRASE at 3 T. Magn Reson Med 2005; 54: 1241-1247.
-
(2005)
Magn Reson Med
, vol.54
, pp. 1241-1247
-
-
Fernandez-Seara, M.A.1
Wang, Z.2
Wang, J.3
Rao, H.Y.4
Guenther, M.5
Feinberg, D.A.6
Detre, J.A.7
-
6
-
-
24144462588
-
Continuous ASL (CASL) perfusion MRI with an array coil and parallel imaging at 3T
-
Wang Z, Wang J, Connick TJ, Wetmore GS, Detre JA,. Continuous ASL (CASL) perfusion MRI with an array coil and parallel imaging at 3T. Magn Reson Med 2005; 54: 732-737.
-
(2005)
Magn Reson Med
, vol.54
, pp. 732-737
-
-
Wang, Z.1
Wang, J.2
Connick, T.J.3
Wetmore, G.S.4
Detre, J.A.5
-
7
-
-
0032712873
-
SENSE: Sensitivity encoding for fast MRI
-
Pruessmann KP, Weiger M, Scheidegger MB, Boesiger P,. SENSE: sensitivity encoding for fast MRI. Magn Reson Med 1999; 42: 952-962.
-
(1999)
Magn Reson Med
, vol.42
, pp. 952-962
-
-
Pruessmann, K.P.1
Weiger, M.2
Scheidegger, M.B.3
Boesiger, P.4
-
8
-
-
0033936617
-
Noise reduction in 3D perfusion imaging by attenuating the static signal in arterial spin tagging (ASSIST)
-
Ye FQ, Frank JA, Weinberger DR, McLaughlin AC,. Noise reduction in 3D perfusion imaging by attenuating the static signal in arterial spin tagging (ASSIST). Magn Reson Med 2000; 44: 92-100.
-
(2000)
Magn Reson Med
, vol.44
, pp. 92-100
-
-
Ye, F.Q.1
Frank, J.A.2
Weinberger, D.R.3
McLaughlin, A.C.4
-
9
-
-
0035156514
-
Use of multicoil arrays for separation of signal from multiple slices simultaneously excited
-
Larkman DJ, Hajnal JV, Herlihy AH, Coutts GA, Young IR, Ehnholm G,. Use of multicoil arrays for separation of signal from multiple slices simultaneously excited. J Magn Reson Imaging 2001; 13: 313-317.
-
(2001)
J Magn Reson Imaging
, vol.13
, pp. 313-317
-
-
Larkman, D.J.1
Hajnal, J.V.2
Herlihy, A.H.3
Coutts, G.A.4
Young, I.R.5
Ehnholm, G.6
-
10
-
-
84859708291
-
Simultaneous slice excitationand reconstruction for single shot EPI
-
Seattle, Washington, USA, Abstract 293
-
Nunes RG, Hajnal JV, Golay X, Larkman DJ,. Simultaneous slice excitationand reconstruction for single shot EPI. In Proceedings of the 14th Annual Meeting of ISMRM, Seattle, Washington, USA, 2006. Abstract 293.
-
(2006)
Proceedings of the 14th Annual Meeting of ISMRM
-
-
Nunes, R.G.1
Hajnal, J.V.2
Golay, X.3
Larkman, D.J.4
-
11
-
-
78650982393
-
Multiplexed echo planar imaging for sub-second whole brain FMRI and fast diffusion imaging
-
Feinberg DA, Moeller S, Smith SM, Auerbach E, Ramanna S, Gunther M, Glasser MF, Miller KL, Ugurbil K, Yacoub E,. Multiplexed echo planar imaging for sub-second whole brain FMRI and fast diffusion imaging. PLoS One 2010; 5: e15710.
-
(2010)
PLoS One
, vol.5
-
-
Feinberg, D.A.1
Moeller, S.2
Smith, S.M.3
Auerbach, E.4
Ramanna, S.5
Gunther, M.6
Glasser, M.F.7
Miller, K.L.8
Ugurbil, K.9
Yacoub, E.10
-
12
-
-
77955292827
-
Multiband multislice GE-EPI at 7 tesla, with 16-fold acceleration using partial parallel imaging with application to high spatial and temporal whole-brain fMRI
-
Moeller S, Yacoub E, Olman CA, Auerbach E, Strupp J, Harel N, Ugurbil K,. Multiband multislice GE-EPI at 7 tesla, with 16-fold acceleration using partial parallel imaging with application to high spatial and temporal whole-brain fMRI. Magn Reson Med 2010; 63: 1144-1153.
-
(2010)
Magn Reson Med
, vol.63
, pp. 1144-1153
-
-
Moeller, S.1
Yacoub, E.2
Olman, C.A.3
Auerbach, E.4
Strupp, J.5
Harel, N.6
Ugurbil, K.7
-
13
-
-
84859705233
-
Blipped-controlled aliasing in parallel imaging for simultaneous multislice echo planar imaging with reduced g-factor penalty
-
Setsompop K, Gagoski BA, Polimeni JR, Witzel T, Wedeen VJ, Wald LL,. Blipped-controlled aliasing in parallel imaging for simultaneous multislice echo planar imaging with reduced g-factor penalty. Magn Reson Med 2012; 67: 1210-1224.
-
(2012)
Magn Reson Med
, vol.67
, pp. 1210-1224
-
-
Setsompop, K.1
Gagoski, B.A.2
Polimeni, J.R.3
Witzel, T.4
Wedeen, V.J.5
Wald, L.L.6
-
14
-
-
84865413556
-
Improving diffusion MRI using simultaneous multi-slice echo planar imaging
-
Setsompop K, Cohen-Adad J, Gagoski BA, Raij T, Yendiki A, Keil B, Wedeen VJ, Wald LL,. Improving diffusion MRI using simultaneous multi-slice echo planar imaging. Neuroimage 2012; 63: 569-580.
-
(2012)
Neuroimage
, vol.63
, pp. 569-580
-
-
Setsompop, K.1
Cohen-Adad, J.2
Gagoski, B.A.3
Raij, T.4
Yendiki, A.5
Keil, B.6
Wedeen, V.J.7
Wald, L.L.8
-
15
-
-
0029151256
-
Quantification of relative cerebral blood flow change by flow-sensitive alternating inversion recovery (FAIR) technique: Application to functional mapping
-
Kim SG,. Quantification of relative cerebral blood flow change by flow-sensitive alternating inversion recovery (FAIR) technique: application to functional mapping. Magn Reson Med 1995; 34: 293-301.
-
(1995)
Magn Reson Med
, vol.34
, pp. 293-301
-
-
Kim, S.G.1
-
16
-
-
0141841839
-
Pediatric perfusion imaging using pulsed arterial spin labeling
-
Wang J, Licht DJ, Jahng GH, Liu CS, Rubin JT, Haselgrove J, Zimmerman RA, Detre JA,. Pediatric perfusion imaging using pulsed arterial spin labeling. J Magn Reson Imaging 2003; 18: 404-413.
-
(2003)
J Magn Reson Imaging
, vol.18
, pp. 404-413
-
-
Wang, J.1
Licht, D.J.2
Jahng, G.H.3
Liu, C.S.4
Rubin, J.T.5
Haselgrove, J.6
Zimmerman, R.A.7
Detre, J.A.8
-
17
-
-
85067327884
-
Evaluation of new ASL 3D GRASE sequences using parallel imaging, segmented and interleaved k-space at 3T with 12- and 32-channel Coils
-
Honolulu, Hawaii, USA, Abstract 0622
-
Feinberg D, Ramanna S, Guenther M,. Evaluation of new ASL 3D GRASE sequences using parallel imaging, segmented and interleaved k-space at 3T with 12- and 32-channel Coils. In Proceedings of the 17th Annual Meeting of ISMRM, Honolulu, Hawaii, USA, 2006. Abstract 0622.
-
(2006)
Proceedings of the 17th Annual Meeting of ISMRM
-
-
Feinberg, D.1
Ramanna, S.2
Guenther, M.3
-
18
-
-
0036325034
-
Comparison of quantitative perfusion imaging using arterial spin labeling at 1.5 and 4.0 Tesla
-
Wang J, Alsop DC, Li L, Listerud J, Gonzalez-At JB, Schnall MD, Detre JA,. Comparison of quantitative perfusion imaging using arterial spin labeling at 1.5 and 4.0 Tesla. Magn Reson Med 2002; 48: 242-254.
-
(2002)
Magn Reson Med
, vol.48
, pp. 242-254
-
-
Wang, J.1
Alsop, D.C.2
Li, L.3
Listerud, J.4
Gonzalez-At, J.B.5
Schnall, M.D.6
Detre, J.A.7
-
19
-
-
0031932352
-
Self-navigated spiral fMRI: Interleaved versus single-shot
-
Glover GH, Lai S,. Self-navigated spiral fMRI: interleaved versus single-shot. Magn Reson Med 1998; 39: 361-368.
-
(1998)
Magn Reson Med
, vol.39
, pp. 361-368
-
-
Glover, G.H.1
Lai, S.2
-
20
-
-
84875275149
-
Comparison of 2D and 3D single-shot ASL perfusion fMRI sequences
-
Vidorreta M, Wang Z, Rodriguez I, Pastor MA, Detre JA, Fernandez-Seara MA,. Comparison of 2D and 3D single-shot ASL perfusion fMRI sequences. Neuroimage 2012; 66C: 662-671.
-
(2012)
Neuroimage
, vol.66 C
, pp. 662-671
-
-
Vidorreta, M.1
Wang, Z.2
Rodriguez, I.3
Pastor, M.A.4
Detre, J.A.5
Fernandez-Seara, M.A.6
-
21
-
-
84875218349
-
Ultra-fast MRI of the human brain with simultaneous multi-slice imaging
-
Feinberg DA, Setsompop K,. Ultra-fast MRI of the human brain with simultaneous multi-slice imaging. J Magn Reson 2013; 229: 90-100.
-
(2013)
J Magn Reson
, vol.229
, pp. 90-100
-
-
Feinberg, D.A.1
Setsompop, K.2
|