메뉴 건너뛰기




Volumn 4, Issue 11, 2014, Pages 868-874

Biodegradable metal stents: A focused review on materials and clinical studies

Author keywords

Biodegradable Metals; Biodegradable Stent; Coronary Artery Disease; Iron; Magnesium; Zinc

Indexed keywords

ALLOY; IRON; MAGNESIUM; NITINOL; STAINLESS STEEL; ZINC;

EID: 84921324952     PISSN: 21579083     EISSN: 21579091     Source Type: Journal    
DOI: 10.1166/jbt.2014.1263     Document Type: Article
Times cited : (36)

References (41)
  • 4
    • 28844497993 scopus 로고    scopus 로고
    • Control of smooth muscle cell proliferation by ferrous iron
    • P. P. Mueller, T. May, A. Perz, H. Hauser, and M. Peuster, Control of smooth muscle cell proliferation by ferrous iron. Biomaterials 27, 2193 (2006).
    • (2006) Biomaterials , vol.27 , pp. 2193
    • Mueller, P.P.1    May, T.2    Perz, A.3    Hauser, H.4    Peuster, M.5
  • 6
    • 23844511571 scopus 로고    scopus 로고
    • Healing achilles–serolimus versus paclitaxel
    • D. J. Molitermo, Healing achilles–serolimus versus paclitaxel. New England Journal of Medicine 353, 724 (2005).
    • (2005) Newengland Journal of Medicine , vol.353 , pp. 724
    • Molitermo, D.J.1
  • 7
    • 33847167065 scopus 로고    scopus 로고
    • Early and late coronary stent thrombosis of sirolimus-eluting and paclitaxel-eluting stents in routine clinical practice: Data from a large two-institutional cohort study
    • J. Daemen, P. Wenaweser, and K. Tsuchida, Early and late coronary stent thrombosis of sirolimus-eluting and paclitaxel-eluting stents in routine clinical practice: Data from a large two-institutional cohort study. Lancet 369, 667 (2007).
    • (2007) Lancet , vol.369 , pp. 667
    • Daemen, J.1    Wenaweser, P.2    Tsuchida, K.3
  • 8
    • 33745233024 scopus 로고    scopus 로고
    • Pathology of drug-eluting stents in human: Delayed healing and late thrombosis risk
    • M. Joner, A. V. Finn, and A. Farb, Pathology of drug-eluting stents in human: Delayed healing and late thrombosis risk. Journal of Amer-ical College of Cardiology 48, 193 (2006).
    • (2006) Journal of Amer-Ical College of Cardiology , vol.48 , pp. 193
    • Joner, M.1    Finn, A.V.2    Farb, A.3
  • 9
    • 0037137302 scopus 로고    scopus 로고
    • Mechanism of late in-stent restenosis after implantation of a paclitaxel derivate-eluting polymer stent system in humans
    • R. Virmani, F. Liistro, and G. Stankovic, Mechanism of late in-stent restenosis after implantation of a paclitaxel derivate-eluting polymer stent system in humans. Circulation 106, 2649 (2002).
    • (2002) Circulation , vol.106 , pp. 2649
    • Virmani, R.1    Liistro, F.2    Stankovic, G.3
  • 11
    • 77952378647 scopus 로고    scopus 로고
    • Late stent malapposition risk is higher after drug-eluting stent compared with bare-metal stent implantation and associates with late stent thrombosis
    • A. K. Hassan, S. C. Bergheanu, T. Stijnen, B. L. van der Hoeven, J. D. Snoep, J. W. Plevier, M. J. Schalij, and J. W. Jukema, Late stent malapposition risk is higher after drug-eluting stent compared with bare-metal stent implantation and associates with late stent thrombosis. European Heart Journal 31, 1172 (2010).
    • (2010) European Heart Journal , vol.31 , pp. 1172
    • Hassan, A.K.1    Bergheanu, S.C.2    Stijnen, T.3    Van Der Hoeven, B.L.4    Snoep, J.D.5    Plevier, J.W.6    Schalij, M.J.7    Jukema, J.W.8
  • 12
    • 77951915002 scopus 로고    scopus 로고
    • Degradable metallic biomaterials: The concept, current developments and future directions
    • H. Hermawan and D. Mantovani, Degradable metallic biomaterials: The concept, current developments and future directions. Minerva Biotecnol. 21, 207 (2009).
    • (2009) Minerva Biotecnol , vol.21 , pp. 207
    • Hermawan, H.1    Mantovani, D.2
  • 15
    • 0037421516 scopus 로고    scopus 로고
    • Magnesium: Nutrition and metabolism
    • J. Vormann, Magnesium: Nutrition and metabolism. Molecular Aspects of Medicine 24, 27 (2003).
    • (2003) Molecular Aspects of Medicine , vol.24 , pp. 27
    • Vormann, J.1
  • 16
    • 0038486163 scopus 로고    scopus 로고
    • Biocorrosion of magnesium alloys: A new principle in cadiovascular implant technology
    • B. Heublein, B. Rohde, V. Kaese, M. Niemeyer, W. Hartung, and A. Haverich, Biocorrosion of magnesium alloys: A new principle in cadiovascular implant technology. Heart 89, 651 (2003).
    • (2003) Heart , vol.89 , pp. 651
    • Heublein, B.1    Rohde, B.2    Kaese, V.3    Niemeyer, M.4    Hartung, W.5    Haverich, A.6
  • 19
    • 34249655184 scopus 로고    scopus 로고
    • Temporary scaffolding of coronary arteries with bioab-sorbable magnesium stents: A prospective, non-randomised multi-centre trial
    • R. Erbel, C. Di Mario, J. Bartunek, J. Bonnier, B. de Bruyne, F. R. Eberli, et al., Temporary scaffolding of coronary arteries with bioab-sorbable magnesium stents: A prospective, non-randomised multi-centre trial. Lancet 369, 1869 (2007).
    • (2007) Lancet , vol.369 , pp. 1869
    • Erbel, R.1    Di Mario, C.2    Bartunek, J.3    Bonnier, J.4    De Bruyne, B.5    Eberli, F.R.6
  • 21
    • 33744988409 scopus 로고    scopus 로고
    • Long term biocompatibility of a corrodible peripheral iron stent in the porcine descending aorta
    • M. Peuster, C. Hesse, T. Schloo, C. Fink, P. Beerbaum, and C. V. Schnakenburg, Long term biocompatibility of a corrodible peripheral iron stent in the porcine descending aorta. Biomaterials 27, 4955 (2006).
    • (2006) Biomaterials , vol.27 , pp. 4955
    • Peuster, M.1    Hesse, C.2    Schloo, T.3    Fink, C.4    Beerbaum, P.5    Schnakenburg, C.V.6
  • 22
    • 84925678152 scopus 로고    scopus 로고
    • In vitro and in vivo corrosion properties of new iron-manganese alloys designed for cardiovascular applications
    • 00B, 000
    • A. Drynda, T. Hassel, F. W. Bach, and M. Peuster, In vitro and in vivo corrosion properties of new iron-manganese alloys designed for cardiovascular applications. Journal of Biomedical Materials Research B 00B, 000 (2014), DOI:10.1002/jbm.b.33234.
    • (2014) Journal of Biomedical Materials Research B
    • Drynda, A.1    Hassel, T.2    Bach, F.W.3    Peuster, M.4
  • 23
    • 77954673809 scopus 로고    scopus 로고
    • Developments in metallic biodegradable stents
    • H. Hermawan, D. Dube, and D. Mantovani, Developments in metallic biodegradable stents. Acta Biomaterialia 6, 1693 (2010).
    • (2010) Acta Biomaterialia , vol.6 , pp. 1693
    • Hermawan, H.1    Dube, D.2    Mantovani, D.3
  • 25
    • 84877289884 scopus 로고    scopus 로고
    • Zinc exhibits ideal physiological corrosion behavior for bioabsorbable stents
    • P. K. Bowen, J. Drelich, and J. Goldman, Zinc exhibits ideal physiological corrosion behavior for bioabsorbable stents. Advanced Materials 25, 2577 (2013).
    • (2013) Advanced Materials , vol.25 , pp. 2577
    • Bowen, P.K.1    Drelich, J.2    Goldman, J.3
  • 26
    • 79961009882 scopus 로고    scopus 로고
    • Mechanical and corrosion properties of newly developed biodegradable Zn-based alloys for bone fixation
    • D. Vojtech, J. Kubasek, J. Serak, and P. Novak, Mechanical and corrosion properties of newly developed biodegradable Zn-based alloys for bone fixation. Acta Biomaterialia 7, 3515 (2011).
    • (2011) Acta Biomaterialia , vol.7 , pp. 3515
    • Vojtech, D.1    Kubasek, J.2    Serak, J.3    Novak, P.4
  • 29
    • 0034778878 scopus 로고    scopus 로고
    • A novel approach to temporary stenting: Degradable cardiovascular stents produced from corodble metal-results 6-18 months after implantation into New Zealand white rabbits
    • M. Peuster, P. Wohlsein, M. Brugmann, M. Ehlerding, K. Seidler, C. Fink, H. Brauer, A. Fischer, and G. Hausdorf, A novel approach to temporary stenting: Degradable cardiovascular stents produced from corodble metal-results 6-18 months after implantation into New Zealand white rabbits. Heart 86, 563 (2001).
    • (2001) Heart , vol.86 , pp. 563
    • Peuster, M.1    Wohlsein, P.2    Brugmann, M.3    Ehlerding, M.4    Seidler, K.5    Fink, C.6    Brauer, H.7    Fischer, A.8    Hausdorf, G.9
  • 31
    • 12144250767 scopus 로고    scopus 로고
    • Preliminary results after application of absorable metal stents in patients with critical limb ischemia
    • P. Peeters, M. Bosiers, J. Verbist, K. Deloose, and B. Heublein, Preliminary results after application of absorable metal stents in patients with critical limb ischemia. Journal of Endovascular Therapy 12, 1 (2005).
    • (2005) Journal of Endovascular Therapy , vol.12 , pp. 1
    • Peeters, P.1    Bosiers, M.2    Verbist, J.3    Deloose, K.4    Heublein, B.5
  • 33
    • 28844455504 scopus 로고    scopus 로고
    • Firt successful implantation of a biodegradable metal stent into the left pulmonary artery of a preterm baby
    • P. Zartner, R. Cesnjevar, H. Singer, and M. Weyand, Firt successful implantation of a biodegradable metal stent into the left pulmonary artery of a preterm baby. Catheterization and Cardiovascular Interventions 66, 590 (2005).
    • (2005) Catheterization and Cardiovascular Interventions , vol.66 , pp. 590
    • Zartner, P.1    Cesnjevar, R.2    Singer, H.3    Weyand, M.4
  • 35
    • 34547940121 scopus 로고    scopus 로고
    • In vitro and in vivo biocompatibility testing of absorbable metal stents
    • A. Loos, R. Rohde, A. Haverich, and S. Barlach, In vitro and in vivo biocompatibility testing of absorbable metal stents. Macromolecular Symposia 253, 103 (2007).
    • (2007) Macromolecular Symposia , vol.253 , pp. 103
    • Loos, A.1    Rohde, R.2    Haverich, A.3    Barlach, S.4
  • 37
    • 62149102609 scopus 로고    scopus 로고
    • Negative vascular reodelling after implantation of bioabsorbable magnesium alloy stents in porcine coronary arteries: A randomised comparison with bare-metal and sirolimus-eluting stents
    • M. Maeng, L. O. Jensen, E. Falk, H. R. Andersen, and L. Thuesen, Negative vascular reodelling after implantation of bioabsorbable magnesium alloy stents in porcine coronary arteries: A randomised comparison with bare-metal and sirolimus-eluting stents. Heart 95, 241 (2009).
    • (2009) Heart , vol.95 , pp. 241
    • Maeng, M.1    Jensen, L.O.2    Falk, E.3    Andersen, H.R.4    Thuesen, L.5
  • 38
    • 0037290055 scopus 로고    scopus 로고
    • Degradation of tungsten coils implanted into the subclavian artery of New Zealand white rabbits is not associated with local or systemic toxicity
    • M. Peuster, C. Fink, P. Wohlsein, M. Bruegmann, A. Gunther, V. Kaese, M. Niemeyer, H. Haferkamp, and C. van Schnakenburg, Degradation of tungsten coils implanted into the subclavian artery of New Zealand white rabbits is not associated with local or systemic toxicity. Biomaterials 24, 393 (2003).
    • (2003) Biomaterials , vol.24 , pp. 393
    • Peuster, M.1    Fink, C.2    Wohlsein, P.3    Bruegmann, M.4    Gunther, A.5    Kaese, V.6    Niemeyer, M.7    Haferkamp, H.8    Van Schnakenburg, C.9
  • 41
    • 77954682989 scopus 로고    scopus 로고
    • Assessing the biocompatibility of degradable metallic materials: State-of-the-art and focus on the potential of genetic regulation
    • A. Purnama, H. Hermawan, J. Couet, and D. Mantovani, Assessing the biocompatibility of degradable metallic materials: State-of-the-art and focus on the potential of genetic regulation. Acta Biomateri-alia 6, 1800 (2010).
    • (2010) Acta Biomateri-Alia , vol.6 , pp. 1800
    • Purnama, A.1    Hermawan, H.2    Couet, J.3    Mantovani, D.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.