메뉴 건너뛰기




Volumn 21, Issue 1, 2008, Pages 15-20

Short-term effects of biocorrodible iron stents in porcine coronary arteries

Author keywords

[No Author keywords available]

Indexed keywords

CHROMIUM; COBALT; FIBRIN; IRON;

EID: 38749145234     PISSN: 08964327     EISSN: 15408183     Source Type: Journal    
DOI: 10.1111/j.1540-8183.2007.00319.x     Document Type: Article
Times cited : (224)

References (23)
  • 1
    • 0023153178 scopus 로고
    • Intravascular stents to prevent occlusion and restenosis after transluminal angioplasty
    • Sigwart U, Puel J, Mirkovitch V, et al. Intravascular stents to prevent occlusion and restenosis after transluminal angioplasty. N Engl J Med 1987 316 : 701 706.
    • (1987) N Engl J Med , vol.316 , pp. 701-706
    • Sigwart, U.1    Puel, J.2    Mirkovitch, V.3
  • 2
    • 0141765805 scopus 로고    scopus 로고
    • Sirolimus-eluting stents versus standard stents in patients with stenosis in a native coronary artery
    • Moses JW, Leon MB, Popma JJ, et al. Sirolimus-eluting stents versus standard stents in patients with stenosis in a native coronary artery. N Engl J Med 2003 349 : 1315 1323.
    • (2003) N Engl J Med , vol.349 , pp. 1315-1323
    • Moses, J.W.1    Leon, M.B.2    Popma, J.J.3
  • 3
    • 0034888007 scopus 로고    scopus 로고
    • Pressure rinsing of coronary stents immediately before implantation reduces inflammation and neointimal hyperplasia
    • Bayes-Genis A, Camrud AR, Jorgenson M, et al. Pressure rinsing of coronary stents immediately before implantation reduces inflammation and neointimal hyperplasia. J Am Coll Cardiol 2001 38 : 562 568.
    • (2001) J Am Coll Cardiol , vol.38 , pp. 562-568
    • Bayes-Genis, A.1    Camrud, A.R.2    Jorgenson, M.3
  • 4
    • 0346668290 scopus 로고    scopus 로고
    • Influence of stent design and deployment technique on neointima formation and vascular remodeling
    • Konig A, Schiele TM, Rieber J, et al. Influence of stent design and deployment technique on neointima formation and vascular remodeling. Z Kardiol 2002 91 Suppl 3 98 102.
    • (2002) Z Kardiol , vol.91 , Issue.3 , pp. 98-102
    • Konig, A.1    Schiele, T.M.2    Rieber, J.3
  • 5
    • 33745233024 scopus 로고    scopus 로고
    • Pathology of drug-eluting stents in humans: Delayed healing and late thrombotic risk
    • Joner M, Finn AV, Farb A, et al. Pathology of drug-eluting stents in humans: Delayed healing and late thrombotic risk. J Am Coll Cardiol 2006 48 : 193 202.
    • (2006) J Am Coll Cardiol , vol.48 , pp. 193-202
    • Joner, M.1    Finn, A.V.2    Farb, A.3
  • 6
    • 22144474043 scopus 로고    scopus 로고
    • Differential response of delayed healing and persistent inflammation at sites of overlapping sirolimus- or paclitaxel-eluting stents
    • Finn AV, Kolodgie FD, Harnek J, et al. Differential response of delayed healing and persistent inflammation at sites of overlapping sirolimus- or paclitaxel-eluting stents. Circulation 2005 112 : 270 278.
    • (2005) Circulation , vol.112 , pp. 270-278
    • Finn, A.V.1    Kolodgie, F.D.2    Harnek, J.3
  • 7
    • 1542646974 scopus 로고    scopus 로고
    • Drug-eluting versus bare metal coronary stents: Long-term human pathology: Findings from different coronary arteries in the same patient
    • Guagliumi G, Virmani R, Musumeci G, et al. Drug-eluting versus bare metal coronary stents: Long-term human pathology: Findings from different coronary arteries in the same patient. Ital Heart J 2003 4 : 713 720.
    • (2003) Ital Heart J , vol.4 , pp. 713-720
    • Guagliumi, G.1    Virmani, R.2    Musumeci, G.3
  • 8
    • 33644775142 scopus 로고    scopus 로고
    • Clinical efficacy of polymer-based paclitaxel-eluting stents in the treatment of complex, long coronary artery lesions from a multicenter, randomized trial: Support for the use of drug-eluting stents in contemporary clinical practice
    • TAXUS VI Investigators.
    • Dawkins KD, Grube E, Guagliumi G, et al. TAXUS VI Investigators. Clinical efficacy of polymer-based paclitaxel-eluting stents in the treatment of complex, long coronary artery lesions from a multicenter, randomized trial: Support for the use of drug-eluting stents in contemporary clinical practice. Circulation 2005 112 : 3306 3313.
    • (2005) Circulation , vol.112 , pp. 3306-3313
    • Dawkins, K.D.1    Grube, E.2    Guagliumi, G.3
  • 9
    • 33845319222 scopus 로고    scopus 로고
    • For the BASKET-LATE Investigators. Late clinical events after clopidogrel discontinuation may limit the benefit of drug-eluting versus bare-metal stents: An observational study of drug-eluting versus bare-metal stents
    • Pfisterer M, Brunner-La Rocca HP, Buser PT, et al., for the BASKET-LATE Investigators. Late clinical events after clopidogrel discontinuation may limit the benefit of drug-eluting versus bare-metal stents: An observational study of drug-eluting versus bare-metal stents. J Am Coll Cardiol 2006 48 : 2584 2591.
    • (2006) J Am Coll Cardiol , vol.48 , pp. 2584-2591
    • Pfisterer, M.1    Brunner-La Rocca, H.P.2    Buser, P.T.3
  • 10
    • 33846125284 scopus 로고    scopus 로고
    • Clopidogrel use and long-term clinical outcomes after drug-eluting stent implantation
    • Eisenstein EL, Anstrom KJ, Kong DF, et al. Clopidogrel use and long-term clinical outcomes after drug-eluting stent implantation. JAMA 2007 297 : 209 211.
    • (2007) JAMA , vol.297 , pp. 209-211
    • Eisenstein, E.L.1    Anstrom, K.J.2    Kong, D.F.3
  • 11
    • 0037286702 scopus 로고    scopus 로고
    • Biodegradable stents as a platform to drug loading
    • Tsuji T, Tamai H, Igaki K, et al. Biodegradable stents as a platform to drug loading. Int J Cardiovasc Intervent 2003 5 : 13 16.
    • (2003) Int J Cardiovasc Intervent , vol.5 , pp. 13-16
    • Tsuji, T.1    Tamai, H.2    Igaki, K.3
  • 12
    • 0031689471 scopus 로고    scopus 로고
    • Intramural delivery of a specific tyrosine kinase inhibitor with biodegradable stent suppresses the restenotic changes of the coronary artery in pigs in vivo
    • Yamawaki T, Shimokawa H, Kozai T, et al. Intramural delivery of a specific tyrosine kinase inhibitor with biodegradable stent suppresses the restenotic changes of the coronary artery in pigs in vivo. J Am Coll Cardiol 1998 32 : 780 786.
    • (1998) J Am Coll Cardiol , vol.32 , pp. 780-786
    • Yamawaki, T.1    Shimokawa, H.2    Kozai, T.3
  • 13
    • 3242877692 scopus 로고    scopus 로고
    • Long-term assessment of a novel biodegradable paclitaxel-eluting coronary poly-lactide stent
    • Vogt F, Stein A, Rettemeier G, et al. Long-term assessment of a novel biodegradable paclitaxel-eluting coronary poly-lactide stent. Eur Heart J 2004 25 : 1330 1340.
    • (2004) Eur Heart J , vol.25 , pp. 1330-1340
    • Vogt, F.1    Stein, A.2    Rettemeier, G.3
  • 14
    • 0034912732 scopus 로고    scopus 로고
    • Biodegradation of the copolymeric polylactide stent: Long-term follow-up in a rabbit aorta model
    • Hietala EM, Salminen US, Stahls A, et al. Biodegradation of the copolymeric polylactide stent: Long-term follow-up in a rabbit aorta model. J Vasc Res 2001 38 : 361 369.
    • (2001) J Vasc Res , vol.38 , pp. 361-369
    • Hietala, E.M.1    Salminen, U.S.2    Stahls, A.3
  • 15
    • 0007488634 scopus 로고    scopus 로고
    • Initial and 6-month results of biodegradable poly-l-lactic acid coronary stents in humans
    • Tamai H, Igaki K, Kyo E, et al. Initial and 6-month results of biodegradable poly-l-lactic acid coronary stents in humans. Circulation 2000 102 : 399 404.
    • (2000) Circulation , vol.102 , pp. 399-404
    • Tamai, H.1    Igaki, K.2    Kyo, E.3
  • 16
    • 0029761378 scopus 로고    scopus 로고
    • Marked inflammatory sequelae to implantation of biodegradable and nonbiodegradable polymers in porcine coronary arteries
    • van der Giessen W, Lincoff M, Schwartz R, et al. Marked inflammatory sequelae to implantation of biodegradable and nonbiodegradable polymers in porcine coronary arteries. Circulation 1996 94 : 1690 1697.
    • (1996) Circulation , vol.94 , pp. 1690-1697
    • Van Der Giessen, W.1    Lincoff, M.2    Schwartz, R.3
  • 17
    • 0038486163 scopus 로고    scopus 로고
    • Biocorrosion of magnesium alloys: A new principle in cardiovascular implant technology?
    • Heublein B, Rohde R, Kaese V, et al. Biocorrosion of magnesium alloys: A new principle in cardiovascular implant technology? Heart 2003 89 : 651 656.
    • (2003) Heart , vol.89 , pp. 651-656
    • Heublein, B.1    Rohde, R.2    Kaese, V.3
  • 18
    • 33749640689 scopus 로고    scopus 로고
    • Safety and efficacy of bioabsorbable magnesium alloy stents in porcine coronary arteries
    • Waksman R, Pakala R, Kuchulakanti PK, et al. Safety and efficacy of bioabsorbable magnesium alloy stents in porcine coronary arteries. Catheter Cardiovasc Interv 2006 68 : 607 617.
    • (2006) Catheter Cardiovasc Interv , vol.68 , pp. 607-617
    • Waksman, R.1    Pakala, R.2    Kuchulakanti, P.K.3
  • 19
    • 0034778878 scopus 로고    scopus 로고
    • A novel approach to temporary stenting: Degradable cardiovascular stents produced from corrodible metal-results 6-18 months after implantation into New Zealand white rabbits
    • Peuster M, Wohlsein P, Brugmann M, et al. A novel approach to temporary stenting: Degradable cardiovascular stents produced from corrodible metal-results 6-18 months after implantation into New Zealand white rabbits. Heart 2001 86 : 563 569.
    • (2001) Heart , vol.86 , pp. 563-569
    • Peuster, M.1    Wohlsein, P.2    Brugmann, M.3
  • 20
    • 0026515530 scopus 로고
    • Restenosis and the proportional neointimal response to coronary artery injury: Results in a porcine model
    • Schwartz RS, Huber KC, Murphy JG, et al. Restenosis and the proportional neointimal response to coronary artery injury: Results in a porcine model. J. Am. Coll Cardiol 1992 19 : 267 274.
    • (1992) J. Am. Coll Cardiol , vol.19 , pp. 267-274
    • Schwartz, R.S.1    Huber, K.C.2    Murphy, J.G.3
  • 21
    • 0033599057 scopus 로고    scopus 로고
    • Disorders of iron metabolism
    • Andrews NC. Disorders of iron metabolism. N Engl J Med 1999 341 : 1986 1995.
    • (1999) N Engl J Med , vol.341 , pp. 1986-1995
    • Andrews, N.C.1
  • 22
    • 0031931030 scopus 로고    scopus 로고
    • A randomized trial of three iron dextran infusion methods for anemia in EPO-treated dialysis patients
    • Auerbach M, Winchester J, Wahab A, et al. A randomized trial of three iron dextran infusion methods for anemia in EPO-treated dialysis patients. Am J Kidney Dis 1998 31 : 81 86.
    • (1998) Am J Kidney Dis , vol.31 , pp. 81-86
    • Auerbach, M.1    Winchester, J.2    Wahab, A.3
  • 23
    • 0023939763 scopus 로고
    • Clinical use of the total dose intravenous infusion of iron dextran
    • Auerbach M, Witt D, Toler W, et al. Clinical use of the total dose intravenous infusion of iron dextran. J Lab Clin Med 1988 111 : 566 570.
    • (1988) J Lab Clin Med , vol.111 , pp. 566-570
    • Auerbach, M.1    Witt, D.2    Toler, W.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.