메뉴 건너뛰기




Volumn 103, Issue 3, 2015, Pages 649-660

In vitro and in vivo corrosion properties of new iron-manganese alloys designed for cardiovascular applications

Author keywords

biocompatibility; biodegradation; congenital heart defects; FeMn alloys

Indexed keywords

ALLOYING; ALLOYS; BIOCOMPATIBILITY; BIODEGRADATION; CORROSION; CORROSION RESISTANCE; IRON; MAGNESIUM; MAGNESIUM ALLOYS; MANGANESE; MANGANESE ALLOYS; MICROBIOLOGY; SCANNING ELECTRON MICROSCOPY; STENTS;

EID: 84925678152     PISSN: 15524973     EISSN: 15524981     Source Type: Journal    
DOI: 10.1002/jbm.b.33234     Document Type: Article
Times cited : (98)

References (30)
  • 2
    • 0035091160 scopus 로고    scopus 로고
    • Intravascular and intracardiac stents used in congenital heart disease
    • Okubo M, Benson LN,. Intravascular and intracardiac stents used in congenital heart disease. Curr Opin Cardiol 2001; 16: 84-91.
    • (2001) Curr Opin Cardiol , vol.16 , pp. 84-91
    • Okubo, M.1    Benson, L.N.2
  • 3
    • 0023153178 scopus 로고
    • Intravascular stents to prevent occlusion and restenosis after transluminal angioplasty
    • Sigwart U, Puel J, Mirkovitch V, Joffre F, Kappenberger L,. Intravascular stents to prevent occlusion and restenosis after transluminal angioplasty. N Engl J Med 1987; 316: 701-706.
    • (1987) N Engl J Med , vol.316 , pp. 701-706
    • Sigwart, U.1    Puel, J.2    Mirkovitch, V.3    Joffre, F.4    Kappenberger, L.5
  • 5
    • 0035256068 scopus 로고    scopus 로고
    • Corrosion behavior of a welded stainless-steel orthopedic implant
    • Reclaru L, Lerf R, Eschler PY, Meyer JM,. Corrosion behavior of a welded stainless-steel orthopedic implant. Biomaterials 2001; 22: 269-279.
    • (2001) Biomaterials , vol.22 , pp. 269-279
    • Reclaru, L.1    Lerf, R.2    Eschler, P.Y.3    Meyer, J.M.4
  • 6
    • 0037276254 scopus 로고    scopus 로고
    • Microvascular response of striated muscle to metal debris. A comparative in vivo study with titanium and stainless steel
    • Kraft CN, Diedrich O, Burian B, Schmitt O, Wimmer MA,. Microvascular response of striated muscle to metal debris. A comparative in vivo study with titanium and stainless steel. J Bone Joint Surg Br 2003; 85: 133-141.
    • (2003) J Bone Joint Surg Br , vol.85 , pp. 133-141
    • Kraft, C.N.1    Diedrich, O.2    Burian, B.3    Schmitt, O.4    Wimmer, M.A.5
  • 7
    • 0346850951 scopus 로고    scopus 로고
    • Corrosion behavior of nitinol wires in body fluid environments
    • Carroll WM, Kelly MJ,. Corrosion behavior of nitinol wires in body fluid environments. J Biomed Mater Res A 2003; 67: 1123-1130.
    • (2003) J Biomed Mater Res A , vol.67 , pp. 1123-1130
    • Carroll, W.M.1    Kelly, M.J.2
  • 9
    • 0034778878 scopus 로고    scopus 로고
    • A novel approach to temporary stenting: Degradable cardiovascular stents produced from corrodible metal - Results 6-18 months after implantation into New Zealand white rabbits
    • Peuster M, Wohlsein P, Brügmann M, Ehlerding M, Seidler K, Fink C, Brauer H, Fischer A, Hausdorf G,. A novel approach to temporary stenting: degradable cardiovascular stents produced from corrodible metal-Results 6-18 months after implantation into New Zealand white rabbits. Heart 2001; 86: 563-569.
    • (2001) Heart , vol.86 , pp. 563-569
    • Peuster, M.1    Wohlsein, P.2    Brügmann, M.3    Ehlerding, M.4    Seidler, K.5    Fink, C.6    Brauer, H.7    Fischer, A.8    Hausdorf, G.9
  • 10
    • 28844497993 scopus 로고    scopus 로고
    • Control of smooth muscle cell proliferation by ferrous iron
    • Mueller PP, May T, Perz A, Hauser H, Peuster M,. Control of smooth muscle cell proliferation by ferrous iron. Biomaterials 2006; 27: 2193-2200.
    • (2006) Biomaterials , vol.27 , pp. 2193-2200
    • Mueller, P.P.1    May, T.2    Perz, A.3    Hauser, H.4    Peuster, M.5
  • 11
    • 33744988409 scopus 로고    scopus 로고
    • Long-term biocompatibility of a corrodible peripheral iron stent in the porcine descending aorta
    • Peuster M, Hesse C, Schloo T, Fink C, Beerbaum P, von Schnakenburg C,. Long-term biocompatibility of a corrodible peripheral iron stent in the porcine descending aorta. Biomaterials 2006; 27: 4955-4962.
    • (2006) Biomaterials , vol.27 , pp. 4955-4962
    • Peuster, M.1    Hesse, C.2    Schloo, T.3    Fink, C.4    Beerbaum, P.5    Von Schnakenburg, C.6
  • 13
    • 33746035363 scopus 로고    scopus 로고
    • New interests in magnesium
    • Williams D,. New interests in magnesium. Med Device Technol 2006; 17: 9-10.
    • (2006) Med Device Technol , vol.17 , pp. 9-10
    • Williams, D.1
  • 14
    • 28844481103 scopus 로고    scopus 로고
    • Magnesium and its alloys as orthopedic biomaterials
    • Staiger MP, Pietak AM, Huadmai J, Dias G,. Magnesium and its alloys as orthopedic biomaterials. Biomaterials 2006; 27: 1728-1734.
    • (2006) Biomaterials , vol.27 , pp. 1728-1734
    • Staiger, M.P.1    Pietak, A.M.2    Huadmai, J.3    Dias, G.4
  • 20
    • 77950219251 scopus 로고    scopus 로고
    • Development and biocompatibility of a novel corrodible fluoride-coated magnesium-calcium alloy with improved degradation kinetics and adequate mechanical properties for cardiovascular applications
    • Drynda A, Hassel T, Hoehn R, Perz A, Bach FW, Peuster M,. Development and biocompatibility of a novel corrodible fluoride-coated magnesium-calcium alloy with improved degradation kinetics and adequate mechanical properties for cardiovascular applications. J Biomed Mater Res A 2010; 93: 763-775.
    • (2010) J Biomed Mater Res A , vol.93 , pp. 763-775
    • Drynda, A.1    Hassel, T.2    Hoehn, R.3    Perz, A.4    Bach, F.W.5    Peuster, M.6
  • 21
    • 84872684004 scopus 로고    scopus 로고
    • Biocompatibility of fluoride-coated magnesium-calcium alloys with optimized degradation kinetics in a subcutaneous mouse model
    • Drynda A, Seibt J, Hassel T, Bach FW, Peuster M,. Biocompatibility of fluoride-coated magnesium-calcium alloys with optimized degradation kinetics in a subcutaneous mouse model. J Biomed Mater Res A 2013; 101: 33-43.
    • (2013) J Biomed Mater Res A , vol.101 , pp. 33-43
    • Drynda, A.1    Seibt, J.2    Hassel, T.3    Bach, F.W.4    Peuster, M.5
  • 22
    • 77954535213 scopus 로고    scopus 로고
    • Influence of Fe(II) and Fe (III) on the expression of genes related to cholesterol- and fatty acid metabolism in human vascular smooth muscle cells
    • Drynda A, Hoehn R, Peuster M,. Influence of Fe(II) and Fe (III) on the expression of genes related to cholesterol- and fatty acid metabolism in human vascular smooth muscle cells. J Mater Sci Mater Med 2010; 21: 1655-1663.
    • (2010) J Mater Sci Mater Med , vol.21 , pp. 1655-1663
    • Drynda, A.1    Hoehn, R.2    Peuster, M.3
  • 23
    • 77649201086 scopus 로고    scopus 로고
    • Degradable metallic biomaterials: Design and development of Fe-Mn alloys for stents
    • Hermawan H, Dubé D, Mantovani D,. Degradable metallic biomaterials: design and development of Fe-Mn alloys for stents. J Biomed Mater Res A 2010; 93: 1-11.
    • (2010) J Biomed Mater Res A , vol.93 , pp. 1-11
    • Hermawan, H.1    Dubé, D.2    Mantovani, D.3
  • 24
    • 77954684596 scopus 로고    scopus 로고
    • Fe-Mn alloys for metallic biodegradable stents: Degradation and cell viability studies
    • Hermawan H, Purnama A, Dube D, Couet J, Mantovani D,. Fe-Mn alloys for metallic biodegradable stents: Degradation and cell viability studies. Acta Biomater 2010; 6: 1852-1860.
    • (2010) Acta Biomater , vol.6 , pp. 1852-1860
    • Hermawan, H.1    Purnama, A.2    Dube, D.3    Couet, J.4    Mantovani, D.5
  • 25
    • 0015822275 scopus 로고
    • Culture of human endothelial cells derived from umbilical veins. Identification by morphologic and immunologic criteria
    • Jaffe EA, Nachman RL, Becker CG, Minick CR,. Culture of human endothelial cells derived from umbilical veins. Identification by morphologic and immunologic criteria. J Clin Invest 1973; 52: 2745-2756.
    • (1973) J Clin Invest , vol.52 , pp. 2745-2756
    • Jaffe, E.A.1    Nachman, R.L.2    Becker, C.G.3    Minick, C.R.4
  • 26
    • 84907126089 scopus 로고
    • Embedding in epoxy resins for ultrathin sectioning in electron microscopy
    • Richardson KC, Jarett L, Finke EH,. Embedding in epoxy resins for ultrathin sectioning in electron microscopy. Stain Technol 1960; 35: 313-323.
    • (1960) Stain Technol , vol.35 , pp. 313-323
    • Richardson, K.C.1    Jarett, L.2    Finke, E.H.3
  • 28
    • 84898044856 scopus 로고    scopus 로고
    • New insights into manganese toxicity and speciation
    • Michalke B, Fernsebner K,. New insights into manganese toxicity and speciation. J Trace Elem Med Biol 2014; 28: 106-116.
    • (2014) J Trace Elem Med Biol , vol.28 , pp. 106-116
    • Michalke, B.1    Fernsebner, K.2
  • 29
    • 79959843295 scopus 로고    scopus 로고
    • Appendix: Normal blood values: Selected reference values for neonatal, pediatric, and adult populations
    • Hoffman R. Benz E.J. Shattil S.S. et al., editors. 5th ed. Philadelphia, PA: Elsevier Churchill Livingstone;. p
    • Yee DL, Bollard CM, Geaghan SM,. Appendix: Normal blood values: Selected reference values for neonatal, pediatric, and adult populations. In:, Hoffman R, Benz EJ, Shattil SS, et al., editors. Hematology: Basic Principles and Practice, 5th ed. Philadelphia, PA: Elsevier Churchill Livingstone; 2008. p 164.
    • (2008) Hematology: Basic Principles and Practice , pp. 164
    • Yee, D.L.1    Bollard, C.M.2    Geaghan, S.M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.