1
-
-
33751003791
-
Treatment of in-stent restenosis-Back to the future?
-
Camenzind E,. Treatment of in-stent restenosis-Back to the future? N Engl J Med 2006; 355: 2149-2151.
-
(2006)
N Engl J Med
, vol.355
, pp. 2149-2151
-
-
Camenzind, E.1
-
2
-
-
33847766568
-
Analysis of 14 trials comparing sirolimus-eluting stents with bare-metal stents
-
DOI 10.1056/NEJMoa067484
-
Kastrati A, Mehilli J, Pache J, Kaiser C, Valgimigli M, Kelbaek H, Menichelli M, Sabate M, Suttorp MJ, Baumgart D, Seyfarth M, Pfisterer ME, Schomig A,. Analysis of 14 trials comparing sirolimus-eluting stents with bare-metal stents. N Engl J Med 2007; 356: 1030-1039. (Pubitemid 46376803)
-
(2007)
New England Journal of Medicine
, vol.356
, Issue.10
, pp. 1030-1039
-
-
Kastrati, A.1
Mehilli, J.2
Pache, J.3
Kaiser, C.4
Valgimigli, M.5
Kelbaek, H.6
Menichelli, M.7
Sabate, M.8
Suttorp, M.J.9
Baumgart, D.10
Seyfarth, M.11
Pfisterer, M.E.12
Schomig, A.13
-
3
-
-
0034597889
-
Nickel and molybdenum contact allergies in patients with coronary in-stent restenosis
-
Koster R, Vieluf D, Kiehn M, Sommerauer M, Kahler J, Baldus S, Meinertz T, Hamm CW,. Nickel and molybdenum contact allergies in patients with coronary in-stent restenosis. Lancet 2000; 356: 1895-1897.
-
(2000)
Lancet
, vol.356
, pp. 1895-1897
-
-
Koster, R.1
Vieluf, D.2
Kiehn, M.3
Sommerauer, M.4
Kahler, J.5
Baldus, S.6
Meinertz, T.7
Hamm, C.W.8
-
4
-
-
70350489464
-
Revolutionizing biodegradable metals
-
Yun YH, Dong ZY, Lee N, Liu YJ, Xue DC, Guo XF, Kuhlmann J, Doepke A, Halsall HB, Heineman W, Sundaramurthy S, Schulz MJ, Yin ZZ, Shanov V, Hurd D, Nagy P, Li WF, Fox C,. Revolutionizing biodegradable metals. Mater Today 2009; 12: 22-32.
-
(2009)
Mater Today
, vol.12
, pp. 22-32
-
-
Yun, Y.H.1
Dong, Z.Y.2
Lee, N.3
Liu, Y.J.4
Xue, D.C.5
Guo, X.F.6
Kuhlmann, J.7
Doepke, A.8
Halsall, H.B.9
Heineman, W.10
Sundaramurthy, S.11
Schulz, M.J.12
Yin, Z.Z.13
Shanov, V.14
Hurd, D.15
Nagy, P.16
Li, W.F.17
Fox, C.18
-
5
-
-
53149150602
-
Fully biodegradable coronary stents progress to date
-
Ramcharitar S, Serruys PW,. Fully biodegradable coronary stents progress to date. Am J Cardiovasc Drugs 2008; 8: 305-314.
-
(2008)
Am J Cardiovasc Drugs
, vol.8
, pp. 305-314
-
-
Ramcharitar, S.1
Serruys, P.W.2
-
6
-
-
0034713815
-
Biodegradable stents: 'Fulfilling the mission and stepping away'
-
Colombo A, Karvouni E,. Biodegradable stents-"Fulfilling the mission and stepping away". Circulation 2000; 102: 371-373. (Pubitemid 30490672)
-
(2000)
Circulation
, vol.102
, Issue.4
, pp. 371-373
-
-
Colombo, A.1
Karvouni, E.2
-
8
-
-
77954673809
-
Developments in metallic biodegradable stents
-
Hermawan H, Dube D, Mantovani D,. Developments in metallic biodegradable stents. Acta Biomater 2010; 6: 1693-1697.
-
(2010)
Acta Biomater
, vol.6
, pp. 1693-1697
-
-
Hermawan, H.1
Dube, D.2
Mantovani, D.3
-
9
-
-
33644874083
-
Novel magnetic resonance-compatible coronary stent-The absorbable magnesium-alloy stent
-
Eggebrecht H, Rodermann J, Hunold P, Schmermund A, Bose D, Haude M, Erbel R,. Novel magnetic resonance-compatible coronary stent-The absorbable magnesium-alloy stent. Circulation 2005; 112: E303-E304.
-
(2005)
Circulation
, vol.112
-
-
Eggebrecht, H.1
Rodermann, J.2
Hunold, P.3
Schmermund, A.4
Bose, D.5
Haude, M.6
Erbel, R.7
-
10
-
-
34249655184
-
Temporary scaffolding of coronary arteries with bioabsorbable magnesium stents: a prospective, non-randomised multicentre trial
-
DOI 10.1016/S0140-6736(07)60853-8, PII S0140673607608538
-
Erbel R, Di Mario C, Bartunek J, Bonnier J, de Bruyne B, Eberli FR, Erne P, Haude M, Heublein B, Horrigan M, Ilsley C, Bose D, Koolen J, Luscher TF, Weissman N, Waksman R,. Temporary scaffolding of coronary arteries with bioabsorbable magnesium stents: A prospective, non-randomised multicentre trial. Lancet 2007; 369: 1869-1875. (Pubitemid 46829357)
-
(2007)
Lancet
, vol.369
, Issue.9576
, pp. 1869-1875
-
-
Erbel, R.1
Di Mario, C.2
Bartunek, J.3
Bonnier, J.4
De Bruyne, B.5
Eberli, F.R.6
Erne, P.7
Haude, M.8
Heublein, B.9
Horrigan, M.10
Ilsley, C.11
Bose, D.12
Koolen, J.13
Luscher, T.F.14
Weissman, N.15
Waksman, R.16
-
11
-
-
33749640689
-
Safety and efficacy of bioabsorbable magnesium alloy stents in porcine coronary arteries
-
DOI 10.1002/ccd.20727
-
Waksman R, Pakala R, Kuchulakanti PK, Baffour R, Hellinga D, Seabron R, Tio FO, Wittchow E, Hartwig S, Harder C, Rohde R, Heublein B, Andreae A, Waldmann KH, Haverich A,. Safety and efficacy of bioabsorbable magnesium alloy stents in porcine coronary arteries. Catheter Cardiovasc Interv 2006; 68: 607-617. (Pubitemid 44546055)
-
(2006)
Catheterization and Cardiovascular Interventions
, vol.68
, Issue.4
, pp. 607-617
-
-
Waksman, R.1
Pakala, R.2
Kuchulakanti, P.K.3
Baffour, R.4
Hellinga, D.5
Seabron, R.6
Tio, F.O.7
Wittchow, E.8
Hartwig, S.9
Harder, C.10
Rohde, R.11
Heublein, B.12
Andreae, A.13
Waldmann, K.-H.14
Haverich, A.15
-
12
-
-
0038486163
-
Biocorrosion of magnesium alloys: A new principle in cardiovascular implant technology?
-
Heublein B, Rohde R, Kaese V, Niemeyer M, Hartung W, Haverich A,. Biocorrosion of magnesium alloys: A new principle in cardiovascular implant technology? Heart 2003; 89: 651-656. (Pubitemid 36606211)
-
(2003)
Heart
, vol.89
, Issue.6
, pp. 651-656
-
-
Heublein, B.1
Rohde, R.2
Kaese, V.3
Niemeyer, M.4
Hartung, W.5
Haverich, A.6
-
13
-
-
2442507751
-
Six- and Twelve-Month Results from First Human Experience Using Everolimus-Eluting Stents with Bioabsorbable Polymer
-
DOI 10.1161/01.CIR.0000128850.84227.FD
-
Grube E, Sonoda S, Ikeno F, Honda Y, Kar S, Chan C, Gerckens U, Lansky AJ, Fitzgerald PJ,. Six- and twelve-month results from first human experience using everolimus-eluting stents with bioabsorbable polymer. Circulation 2004; 109: 2168-2171. (Pubitemid 38625391)
-
(2004)
Circulation
, vol.109
, Issue.18
, pp. 2168-2171
-
-
Grube, E.1
Sonoda, S.2
Ikeno, F.3
Honda, Y.4
Kar, S.5
Chan, C.6
Gerckens, U.7
Lansky, A.J.8
Fitzgerald, P.J.9
-
14
-
-
0007488634
-
Initial and 6-month results of biodegradable poly-l-lactic acid coronary stents in humans
-
Tamai H, Igaki K, Kyo E, Kosuga K, Kawashima A, Matsui S, Komori H, Tsuji T, Motohara S, Uehata H,. Initial and 6-month results of biodegradable poly- L -lactic acid coronary stents in humans. Circulation 2000; 102: 399-404. (Pubitemid 30490677)
-
(2000)
Circulation
, vol.102
, Issue.4
, pp. 399-404
-
-
Tamai, H.1
Igaki, K.2
Kyo, E.3
Kosuga, K.4
Kawashima, A.5
Matsui, S.6
Komori, H.7
Tsuji, T.8
Motohara, S.9
Uehata, H.10
-
15
-
-
0034580276
-
Synthetic biodegradable polymers as orthopedic devices
-
Middleton JC, Tipton AJ,. Synthetic biodegradable polymers as orthopedic devices. Biomaterials 2000; 21: 2335-2346.
-
(2000)
Biomaterials
, vol.21
, pp. 2335-2346
-
-
Middleton, J.C.1
Tipton, A.J.2
-
16
-
-
33744988409
-
Long-term biocompatibility of a corrodible peripheral iron stent in the porcine descending aorta
-
DOI 10.1016/j.biomaterials.2006.05.029, PII S0142961206004923
-
Peuster M, Hesse C, Schloo T, Fink C, Beerbaum P, von Schnakenburg C,. Long-term biocompatibility of a corrodible peripheral iron stent in the porcine descending aorta. Biomaterials 2006; 27: 4955-4962. (Pubitemid 43866928)
-
(2006)
Biomaterials
, vol.27
, Issue.28
, pp. 4955-4962
-
-
Peuster, M.1
Hesse, C.2
Schloo, T.3
Fink, C.4
Beerbaum, P.5
Von Schnakenburg, C.6
-
17
-
-
77954667713
-
Electroformed iron as new biomaterial for degradable stents: Development process and structure-properties relationship
-
Moravej M, Prima F, Fiset M, Mantovani D,. Electroformed iron as new biomaterial for degradable stents: Development process and structure-properties relationship. Acta Biomater 2010; 6: 1726-1735.
-
(2010)
Acta Biomater
, vol.6
, pp. 1726-1735
-
-
Moravej, M.1
Prima, F.2
Fiset, M.3
Mantovani, D.4
-
18
-
-
77954665666
-
Electroformed pure iron as a new biomaterial for degradable stents: In vitro degradation and preliminary cell viability studies
-
Moravej M, Purnama A, Fiset M, Couet J, Mantovani D,. Electroformed pure iron as a new biomaterial for degradable stents: In vitro degradation and preliminary cell viability studies. Acta Biomater 2010; 6: 1843-1851.
-
(2010)
Acta Biomater
, vol.6
, pp. 1843-1851
-
-
Moravej, M.1
Purnama, A.2
Fiset, M.3
Couet, J.4
Mantovani, D.5
-
19
-
-
77649201086
-
Degradable metallic biomaterials: Design and development of Fe-Mn alloys for stents
-
Hermawan H, Dube D, Mantovani D,. Degradable metallic biomaterials: Design and development of Fe-Mn alloys for stents. J Biomed Mater Res A 2010; 93A: 1-11.
-
(2010)
J Biomed Mater Res A
, vol.93 A
, pp. 1-11
-
-
Hermawan, H.1
Dube, D.2
Mantovani, D.3
-
20
-
-
9244220627
-
Drug-eluting bioabsorbable magnesium stent
-
DOI 10.1111/j.1540-8183.2004.04081.x
-
di Mario C, Griffiths H, Goktekin O, Peeters N, Verbist J, Bosiers M, Deloose K, Heublein B, Rohde R, Kasese V, Isley C, Erbel R,. Drug-eluting bioabsorbable magnesium stent. J Interv Cardiol 2004; 17: 391-395. (Pubitemid 39552594)
-
(2004)
Journal of Interventional Cardiology
, vol.17
, Issue.6
, pp. 391-395
-
-
Di Mario, C.1
Griffiths, H.2
Goktekin, O.3
Peeters, N.4
Verbist, J.5
Bosiers, M.6
Deloose, K.7
Heublein, B.8
Rohde, R.9
Kasese, V.10
Ilsley, C.11
Erbel, R.12
-
21
-
-
38749145234
-
Short-term effects of biocorrodible iron stents in porcine coronary arteries
-
DOI 10.1111/j.1540-8183.2007.00319.x
-
Waksman R, Pakala R, Baffour R, Seabron R, Hellinga D, Tio FO,. Short-term effects of biocorrodible iron stents in porcine coronary arteries. J Interv Cardiol 2008; 21: 15-20. (Pubitemid 351178402)
-
(2008)
Journal of Interventional Cardiology
, vol.21
, Issue.1
, pp. 15-20
-
-
Waksman, R.1
Pakala, R.2
Baffour, R.3
Seabron, R.4
Hellinga, D.5
Tio, F.O.6
-
22
-
-
0034778878
-
A novel approach to temporary stenting: Degradable cardiovascular stents produced from corrodible metal - Results 6-18 months after implantation into New Zealand white rabbits
-
Peuster M, Wohlsein P, Brugmann M, Ehlerding M, Seidler K, Fink C, Brauer H, Fischer A, Hausdorf G,. A novel approach to temporary stenting: Degradable cardiovascular stents produced from corrodible metal-Results 6-18 months after implantation into New Zealand white rabbits. Heart 2001; 86: 563-569. (Pubitemid 32999872)
-
(2001)
Heart
, vol.86
, Issue.5
, pp. 563-569
-
-
Peuster, M.1
Wohlsein, P.2
Brugmann, M.3
Ehlerding, M.4
Seidler, K.5
Fink, C.6
Brauer, H.7
Fischer, A.8
Hausdorf, G.9
-
25
-
-
34248670151
-
Corrosion degradation and prevention by surface modification of biometallic materials
-
DOI 10.1007/s10856-006-0016-y
-
Singh R, Dahotre NB,. Corrosion degradation and prevention by surface modification of biometallic materials. J Mater Sci Mater Med 2007; 18: 725-751. (Pubitemid 46766556)
-
(2007)
Journal of Materials Science: Materials in Medicine
, vol.18
, Issue.5
, pp. 725-751
-
-
Singh, R.1
Dahotre, N.B.2
-
26
-
-
64949130692
-
The emerging role of phosphate in vascular calcification
-
Giachelli CM,. The emerging role of phosphate in vascular calcification. Kidney Int 2009; 75: 890-897.
-
(2009)
Kidney Int
, vol.75
, pp. 890-897
-
-
Giachelli, C.M.1
-
27
-
-
33646157733
-
Role of the sodium-dependent phosphate cotransporter. Pit-1, in vascular smooth muscle cell calcification
-
Li X, Yang HY, Giachelli CM,. Role of the sodium-dependent phosphate cotransporter. Pit-1, in vascular smooth muscle cell calcification. Circ Res 2006; 98: 905-912.
-
(2006)
Circ Res
, vol.98
, pp. 905-912
-
-
Li, X.1
Yang, H.Y.2
Giachelli, C.M.3
-
28
-
-
0034730291
-
Phosphate regulation of vascular smooth muscle cell calcification
-
Jono S, McKee MD, Murry CE, Shioi A, Nishizawa Y, Mori K, Morii H, Giachelli CM,. Phosphate regulation of vascular smooth muscle cell calcification. Circ Res 2000; 87: E10-E17.
-
(2000)
Circ Res
, vol.87
-
-
Jono, S.1
McKee, M.D.2
Murry, C.E.3
Shioi, A.4
Nishizawa, Y.5
Mori, K.6
Morii, H.7
Giachelli, C.M.8
-
30
-
-
0002199776
-
Characterization of iron oxides commonly formed as corrosion products on steel
-
Oh SJ, Cook DC, Townsend HE,. Characterization of iron oxides commonly formed as corrosion products on steel. Hyperfine Inter 1998; 112: 59-65. (Pubitemid 128510717)
-
(1998)
Hyperfine Interactions
, vol.112
, Issue.1-4
, pp. 59-65
-
-
Oh, S.J.1
Cook, D.C.2
Townsend, H.E.3
-
31
-
-
19944393951
-
Micro-Raman investigation of iron oxide films and powders produced by sol-gel syntheses
-
Bersani D, Lottici PP, Montenero A,. Micro-Raman investigation of iron oxide films and powders produced by sol-gel syntheses. J Raman Spectrosc 1999; 30: 355-360.
-
(1999)
J Raman Spectrosc
, vol.30
, pp. 355-360
-
-
Bersani, D.1
Lottici, P.P.2
Montenero, A.3
-
32
-
-
66649136224
-
Raman spectroscopy of iron oxides and (oxy)hydroxides at low laser power and possible applications in environmental magnetic studies
-
Hanesch M,. Raman spectroscopy of iron oxides and (oxy)hydroxides at low laser power and possible applications in environmental magnetic studies. Geophys J Int 2009; 177: 941-948.
-
(2009)
Geophys J Int
, vol.177
, pp. 941-948
-
-
Hanesch, M.1
-
33
-
-
38349172403
-
Raman spectroscopic studies of the corrosion of model iron electrodes in sodium chloride solution
-
Larroumet D, Greenfield D, Akid R, Yarwood J,. Raman spectroscopic studies of the corrosion of model iron electrodes in sodium chloride solution. J Raman Spectrosc 2007; 38: 1577-1585.
-
(2007)
J Raman Spectrosc
, vol.38
, pp. 1577-1585
-
-
Larroumet, D.1
Greenfield, D.2
Akid, R.3
Yarwood, J.4
|