메뉴 건너뛰기




Volumn 7, Issue 12, 2014, Pages 8168-8188

Biocompatibility of advanced manufactured titanium implants-A review

Author keywords

3 D printing; Additive manufacturing; Biocompatibility; CP Ti; Cytotoxicity; Implants; Metal injection moulding; Powder metallurgy; Ti6Al4V; Titanium

Indexed keywords

3D PRINTERS; BIOCOMPATIBILITY; BIOMEDICAL EQUIPMENT; BONE; CLINICAL RESEARCH; CYTOTOXICITY; DENTAL PROSTHESES; INJECTION MOLDING; METALS; POROSITY; POWDER METALLURGY; POWDER METALS; PROCESSING; TITANIUM; TITANIUM ALLOYS; TITANIUM CASTINGS;

EID: 84921316054     PISSN: None     EISSN: 19961944     Source Type: Journal    
DOI: 10.3390/ma7128168     Document Type: Review
Times cited : (548)

References (49)
  • 1
    • 46949099962 scopus 로고    scopus 로고
    • Biomedical applications of titanium and its alloys
    • Elias, C.N.; Lima, J.H.C.; Valiev, R.; Meyers, M.A. Biomedical applications of titanium and its alloys. JOM 2008, 60, 46-49.
    • (2008) JOM , vol.60 , pp. 46-49
    • Elias, C.N.1    Lima, J.H.C.2    Valiev, R.3    Meyers, M.A.4
  • 3
    • 84971721829 scopus 로고
    • Regulation of biomaterials and medical devices
    • Mueller, E.; Kammula, R.; Marlowe, D. Regulation of biomaterials and medical devices. MRS Bull. 1991, 16, 39-41.
    • (1991) MRS Bull. , vol.16 , pp. 39-41
    • Mueller, E.1    Kammula, R.2    Marlowe, D.3
  • 4
    • 84866685104 scopus 로고    scopus 로고
    • Titanium powder metallurgy: A review-Part 1
    • Froes, F.H. Titanium powder metallurgy: A review-Part 1. Adv. Mater. Process. 2012, 170, 16-22.
    • (2012) Adv. Mater. Process. , vol.170 , pp. 16-22
    • Froes, F.H.1
  • 7
    • 0018031653 scopus 로고
    • Electrochemical and surface analytical characterization of titanium and titanium hydride thin-film electrode oxidation
    • Quinn, R.K.; Armstrong, N.R. Electrochemical and surface analytical characterization of titanium and titanium hydride thin-film electrode oxidation. J. Electrochem. Soc. 1978, 125, 1790-1796.
    • (1978) J. Electrochem. Soc. , vol.125 , pp. 1790-1796
    • Quinn, R.K.1    Armstrong, N.R.2
  • 8
    • 0036210742 scopus 로고    scopus 로고
    • Influence of fluoride content and pH on the corrosion resistance of titanium and its alloys
    • Schiff, N.; Grosgogeat, B.; Lissac, M.; Dalard, F. Influence of fluoride content and pH on the corrosion resistance of titanium and its alloys. Biomaterials 2002, 23, 1995-2002.
    • (2002) Biomaterials , vol.23 , pp. 1995-2002
    • Schiff, N.1    Grosgogeat, B.2    Lissac, M.3    Dalard, F.4
  • 9
    • 0026589019 scopus 로고
    • Physico-chemical considerations of titanium as a biomaterial
    • Tengvall, P.; Lundström, I. Physico-chemical considerations of titanium as a biomaterial. Clin. Mater. 1992, 9, 115-134.
    • (1992) Clin. Mater. , vol.9 , pp. 115-134
    • Tengvall, P.1    Lundström, I.2
  • 11
    • 0019663098 scopus 로고
    • A 15-year study of osseointegrated implants in the treatment of the edentulous jaw
    • Adell, R.; Lekholm, U.; Rockler, B.; Brånemark, P.I. A 15-year study of osseointegrated implants in the treatment of the edentulous jaw. Int. J. Oral Maxillof. 1981, 10, 387-416.
    • (1981) Int. J. Oral Maxillof. , vol.10 , pp. 387-416
    • Adell, R.1    Lekholm, U.2    Rockler, B.3    Brånemark, P.I.4
  • 12
    • 84921294800 scopus 로고    scopus 로고
    • Standard Specification for Unalloyed Titanium for Surgical Implant Applications (UNS R50250, UNS R50400, UNS R50550, UNS R50700); ASTM F67-13; American Society for Testing Materials: West Conshohocken, PA, USA
    • Standard Specification for Unalloyed Titanium for Surgical Implant Applications (UNS R50250, UNS R50400, UNS R50550, UNS R50700); ASTM F67-13; American Society for Testing Materials: West Conshohocken, PA, USA, 2013.
    • (2013)
  • 13
    • 84921314846 scopus 로고    scopus 로고
    • Standard Specification for Wrought Titanium-6 Aluminum-4 Vanadium ELI (Extra Low Interstitial) Alloy for Surgical Implant Applications (UNS R56401); ASTM F136-13; American Society for Testing Materials: West Conshohocken, PA, USA
    • Standard Specification for Wrought Titanium-6 Aluminum-4 Vanadium ELI (Extra Low Interstitial) Alloy for Surgical Implant Applications (UNS R56401); ASTM F136-13; American Society for Testing Materials: West Conshohocken, PA, USA, 2013.
    • (2013)
  • 14
    • 84873717271 scopus 로고    scopus 로고
    • Correlation of metal injection moulded Ti6Al4V yield strength with resonance frequency (PCRT) measurements
    • Sidambe, A.T.; Choong, W.L.; Hamilton, H.G.C.; Todd, I. Correlation of metal injection moulded Ti6Al4V yield strength with resonance frequency (PCRT) measurements. Mater. Sci. Eng. A Struct. 2013, 568, 220-227.
    • (2013) Mater. Sci. Eng. A Struct. , vol.568 , pp. 220-227
    • Sidambe, A.T.1    Choong, W.L.2    Hamilton, H.G.C.3    Todd, I.4
  • 15
    • 39749114969 scopus 로고    scopus 로고
    • Study on microstructure and mechanical properties of laser rapid forming Inconel 718
    • Zhao, X.; Chen, L.; Xin, L.; Huang, W. Study on microstructure and mechanical properties of laser rapid forming Inconel 718. Mater. Sci. Eng. A Struct. 2008, 478, 119-124.
    • (2008) Mater. Sci. Eng. A Struct. , vol.478 , pp. 119-124
    • Zhao, X.1    Chen, L.2    Xin, L.3    Huang, W.4
  • 18
    • 75149134663 scopus 로고    scopus 로고
    • Mechanical evaluation of porous titanium (Ti6Al4V) structures with electron beam melting (EBM)
    • Parthasarathy, J.; Starly, B.; Raman, S.; Christensen, A. Mechanical evaluation of porous titanium (Ti6Al4V) structures with electron beam melting (EBM). J. Mech. Behav. Biomed. Mater. 2010, 3, 249-259.
    • (2010) J. Mech. Behav. Biomed. Mater. , vol.3 , pp. 249-259
    • Parthasarathy, J.1    Starly, B.2    Raman, S.3    Christensen, A.4
  • 23
    • 84954569649 scopus 로고    scopus 로고
    • ISO 22068-14; International Organisation for Standardisation ISO: Geneva, Switzerland
    • Sintered-Metal Injection-Moulded Materials-Specifications; ISO 22068-14; International Organisation for Standardisation ISO: Geneva, Switzerland, 2014.
    • (2014) Sintered-Metal Injection-Moulded Materials-Specifications
  • 25
    • 84869168489 scopus 로고    scopus 로고
    • Titanium powder metallurgy: A review-Part 2
    • Froes, F.H. Titanium powder metallurgy: A review-Part 2. Adv. Mater. Process. 2012, 170, 26-29.
    • (2012) Adv. Mater. Process. , vol.170 , pp. 26-29
    • Froes, F.H.1
  • 26
    • 84355161961 scopus 로고    scopus 로고
    • The future of dental devices is digital
    • Van Noort, R. The future of dental devices is digital. Dent. Mater. 2012, 28, 3-12.
    • (2012) Dent. Mater. , vol.28 , pp. 3-12
    • Van Noort, R.1
  • 27
    • 59649128181 scopus 로고    scopus 로고
    • High cycle fatigue behaviour of Ti-6Al-4V fabricated by metal injection moulding technology
    • Ferri, O.M.; Ebel, T.; Bormann, R. High cycle fatigue behaviour of Ti-6Al-4V fabricated by metal injection moulding technology. Mat. Sci. Eng. A Struct. 2009, 504, 107-113.
    • (2009) Mat. Sci. Eng. A Struct. , vol.504 , pp. 107-113
    • Ferri, O.M.1    Ebel, T.2    Bormann, R.3
  • 30
    • 79955636988 scopus 로고    scopus 로고
    • Biocompatibility of metal injection molded versus wrought ASTM F562 (MP35N) and ASTM F1537 (CCM) cobalt alloys
    • Chen, H.; Sago, A.; West, S.; Farina, J.; Eckert, J.; Broadley, M. Biocompatibility of metal injection molded versus wrought ASTM F562 (MP35N) and ASTM F1537 (CCM) cobalt alloys. BioMed. Mater. Eng. 2011, 21, 1-7.
    • (2011) BioMed. Mater. Eng. , vol.21 , pp. 1-7
    • Chen, H.1    Sago, A.2    West, S.3    Farina, J.4    Eckert, J.5    Broadley, M.6
  • 31
    • 84881407567 scopus 로고    scopus 로고
    • Additive manufacturing (AM) and nanotechnology: Promises and challenges
    • Ivanova, O.; Williams, C.; Campbell, T. Additive manufacturing (AM) and nanotechnology: Promises and challenges. Rapid Prototyp. J. 2013, 19, 353-364.
    • (2013) Rapid Prototyp. J. , vol.19 , pp. 353-364
    • Ivanova, O.1    Williams, C.2    Campbell, T.3
  • 32
    • 78049433701 scopus 로고    scopus 로고
    • The origin of microstructural diversity, texture, and mechanical properties in electron beam melted Ti-6Al-4V
    • Al-Bermani, S.S.; Blackmore, M.L.; Zhang, W.; Todd, I. The origin of microstructural diversity, texture, and mechanical properties in electron beam melted Ti-6Al-4V. Metall. Mater. Trans. A 2010, 41A, 3422-3434.
    • (2010) Metall. Mater. Trans. A , vol.41 A , pp. 3422-3434
    • Al-Bermani, S.S.1    Blackmore, M.L.2    Zhang, W.3    Todd, I.4
  • 34
    • 67650786995 scopus 로고    scopus 로고
    • Electron beam-melted, free-form-fabricated titanium alloy implants: Material surface characterization and early bone response in rabbits
    • Thomsen, P.; Malmström, J.; Emanuelsson, L.; René, M.; Snis, A. Electron beam-melted, free-form-fabricated titanium alloy implants: Material surface characterization and early bone response in rabbits. J. Biomed. Mater. Res. B 2009, 90B, 35-44.
    • (2009) J. Biomed. Mater. Res. B , vol.90 B , pp. 35-44
    • Thomsen, P.1    Malmström, J.2    Emanuelsson, L.3    René, M.4    Snis, A.5
  • 35
    • 84871320779 scopus 로고    scopus 로고
    • Evaluation of biological properties of electron beam melted Ti6Al4V implant with biomimetic coating in vitro and in vivo
    • Li, X.; Feng, Y.F.; Wang, C.T.; Li, G.C.; Lei, W.; Zhang, Z.Y.; Wang, L. Evaluation of biological properties of electron beam melted Ti6Al4V implant with biomimetic coating in vitro and in vivo. PLos One 2012, 7, e52049, doi:10.1371/journal.pone.0052049.
    • (2012) PLos One , vol.7
    • Li, X.1    Feng, Y.F.2    Wang, C.T.3    Li, G.C.4    Lei, W.5    Zhang, Z.Y.6    Wang, L.7
  • 36
    • 84990329928 scopus 로고    scopus 로고
    • Long-term biocompatibility and osseointegration of electron beam melted, free-form-fabricated solid and porous titanium alloy: Experimental studies in sheep
    • Palmquist, A.; Snis, A.; Emanuelsson, L.; Browne, M.; Thomsen, P. Long-term biocompatibility and osseointegration of electron beam melted, free-form-fabricated solid and porous titanium alloy: Experimental studies in sheep. J. BioMater. Appl. 2013, 27, 1003-1016.
    • (2013) J. BioMater. Appl. , vol.27 , pp. 1003-1016
    • Palmquist, A.1    Snis, A.2    Emanuelsson, L.3    Browne, M.4    Thomsen, P.5
  • 37
    • 0042861273 scopus 로고    scopus 로고
    • Development of individual three-dimensional bone substitutes using "selective laser melting"
    • Hollander, D.A.; Wirtz, T.; Walter, M.V.; Linker, R.; Schultheis, A.; Paar, O. Development of individual three-dimensional bone substitutes using "selective laser melting". Eur. J. Trauma 2003, 4, 228-234.
    • (2003) Eur. J. Trauma , vol.4 , pp. 228-234
    • Hollander, D.A.1    Wirtz, T.2    Walter, M.V.3    Linker, R.4    Schultheis, A.5    Paar, O.6
  • 41
  • 43
    • 84860261987 scopus 로고    scopus 로고
    • Metal injection molding of alloys for implantable medical devices
    • Sago, J.A.; Broadley, M.W.; Eckert, J.K. Metal injection molding of alloys for implantable medical devices. 2012, 48, 41-49.
    • (2012) , vol.48 , pp. 41-49
    • Sago, J.A.1    Broadley, M.W.2    Eckert, J.K.3
  • 44
    • 84902330574 scopus 로고    scopus 로고
    • Influence of surface aspects and properties of MIM titanium alloys for medical applications
    • Auzene, D.; Mallejac, C.; Demangel, C.; Lebel, F.; Duval, J.L.; Vigneron, P.; Puippe, J.C. Influence of surface aspects and properties of MIM titanium alloys for medical applications. PIM Int. 2012, 6, 57-61.
    • (2012) PIM Int. , vol.6 , pp. 57-61
    • Auzene, D.1    Mallejac, C.2    Demangel, C.3    Lebel, F.4    Duval, J.L.5    Vigneron, P.6    Puippe, J.C.7
  • 47
    • 34548523637 scopus 로고    scopus 로고
    • Processing and biocompatibility evaluation of laser processed porous titanium
    • Xue, W.; Krishna, B.V.; Bandyopadhyay, A.; Bose, S. Processing and biocompatibility evaluation of laser processed porous titanium. Acta Biomater. 2007, 3, 1007-1018.
    • (2007) Acta Biomater. , vol.3 , pp. 1007-1018
    • Xue, W.1    Krishna, B.V.2    Bandyopadhyay, A.3    Bose, S.4
  • 48
    • 76949097204 scopus 로고    scopus 로고
    • Influence of porosity on mechanical properties and in vivo response of Ti6Al4V implants
    • Bandyopadhyay, A.; Espana, F.; Balla, V.K.; Bose, S.; Ohgami, Y.; Davies, N.M. Influence of porosity on mechanical properties and in vivo response of Ti6Al4V implants. Acta Biomater. 2010, 6, 1640-1648.
    • (2010) Acta Biomater. , vol.6 , pp. 1640-1648
    • Bandyopadhyay, A.1    Espana, F.2    Balla, V.K.3    Bose, S.4    Ohgami, Y.5    Davies, N.M.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.