메뉴 건너뛰기




Volumn 260, Issue 1, 2011, Pages 248-256

Reduced image noise at low-dose multidetector CT of the abdomen with prior image constrained compressed sensing algorithm

Author keywords

[No Author keywords available]

Indexed keywords

ABDOMEN; ADULT; AGED; ALGORITHM; ANALYTICAL PARAMETERS; ARTICLE; BODY MASS; CLINICAL ARTICLE; CLINICAL EFFECTIVENESS; CLINICAL PROTOCOL; COMPUTED TOMOGRAPHIC COLONOGRAPHY; CONTROLLED STUDY; DOSE RESPONSE; FEMALE; HUMAN; IMAGE QUALITY; LOW ENERGY RADIATION; MALE; MULTIDETECTOR COMPUTED TOMOGRAPHY; NOISE REDUCTION; OPTICAL RESOLUTION; PRIOR IMAGE CONSTRAINED COMPRESSED SENSING ALGORITHM; PRIORITY JOURNAL; RADIATION DOSE; RETROSPECTIVE STUDY;

EID: 79959559491     PISSN: 00338419     EISSN: 15271315     Source Type: Journal    
DOI: 10.1148/radiol.11101380     Document Type: Article
Times cited : (77)

References (30)
  • 1
    • 36549007486 scopus 로고    scopus 로고
    • Computed tomography - An increasing source of radiation exposure
    • DOI 10.1056/NEJMra072149
    • Brenner DJ, Hall EJ. Computed tomography: an increasing source of radiation exposure. N Engl J Med 2007;357(22):2277-2284. (Pubitemid 350190758)
    • (2007) New England Journal of Medicine , vol.357 , Issue.22 , pp. 2277-2284
    • Brenner, D.J.1    Hall, E.J.2
  • 2
    • 0004159024 scopus 로고
    • National Council on Radiation Protection and Measurements. Bethesda, Md: National Council on Radiation Protection and Measurements
    • National Council on Radiation Protection and Measurements. Ionizing radiation exposure of the population of the United States. Bethesda, Md: National Council on Radiation Protection and Measurements, 1987.
    • (1987) Ionizing Radiation Exposure of the Population of the United States
  • 4
    • 25144433343 scopus 로고    scopus 로고
    • Use of an automatic exposure control mechanism for dose optimization in multi-detector row CT examinations: Clinical evaluation
    • DOI 10.1148/radiol.2363041220
    • Mulkens TH, Bellinck P, Baeyaert M, et al. Use of an automatic exposure control mechanism for dose optimization in multi-detector row CT examinations: clinical evaluation. Radiology 2005;237(1):213-223. (Pubitemid 41346166)
    • (2005) Radiology , vol.237 , Issue.1 , pp. 213-223
    • Mulkens, T.H.1    Bellinck, P.2    Baeyaert, M.3    Ghysen, D.4    Van Dijck, X.5    Mussen, E.6    Venstermans, C.7    Termote, J.-L.8
  • 5
    • 33645562681 scopus 로고    scopus 로고
    • CT dose reduction and dose management tools: Overview of available options
    • DOI 10.1148/rg.262055138
    • McCollough CH, Bruesewitz MR, Kofler JM Jr. CT dose reduction and dose management tools: overview of available options. RadioGraphics 2006;26(2):503-512. (Pubitemid 43515321)
    • (2006) Radiographics , vol.26 , Issue.2 , pp. 503-512
    • McCollough, C.H.1    Bruesewitz, M.R.2    Kofler Jr., J.M.3
  • 7
    • 0034055634 scopus 로고    scopus 로고
    • Dose reduction in computed tomography by attenuation-based on-line modulation of tube current: Evaluation of six anatomical regions
    • Greess H, Wolf H, Baum U, et al. Dose reduction in computed tomography by attenuation-based on-line modulation of tube current: evaluation of six anatomical regions. Eur Radiol 2000;10(2):391-394. (Pubitemid 30136846)
    • (2000) European Radiology , vol.10 , Issue.2 , pp. 391-394
    • Greess, H.1    Wolf, H.2    Baum, U.3    Lell, M.4    Pirkl, M.5    Kalender, W.6    Bautz, W.A.7
  • 8
    • 27744466794 scopus 로고    scopus 로고
    • Automatic exposure control in CT: Are we done yet?
    • McCollough CH. Automatic exposure control in CT: are we done yet? Radiology 2005;237(3):755-756.
    • (2005) Radiology , vol.237 , Issue.3 , pp. 755-756
    • McCollough, C.H.1
  • 9
    • 0032744531 scopus 로고    scopus 로고
    • Dose reduction in CT by anatomically adapted tube current modulation. I. Simulation studies
    • Gies M, Kalender WA, Wolf H, Suess C. Dose reduction in CT by anatomically adapted tube current modulation. I. Simulation studies. Med Phys 1999;26(11):2235-2247.
    • (1999) Med Phys , vol.26 , Issue.11 , pp. 2235-2247
    • Gies, M.1    Kalender, W.A.2    Wolf, H.3    Suess, C.4
  • 10
    • 0032742081 scopus 로고    scopus 로고
    • Dose reduction in CT by anatomically adapted tube current modulation. II. Phantom measurements
    • Kalender WA, Wolf H, Suess C. Dose reduction in CT by anatomically adapted tube current modulation. II. Phantom measurements. Med Phys 1999;26(11):2248-2253.
    • (1999) Med Phys , vol.26 , Issue.11 , pp. 2248-2253
    • Kalender, W.A.1    Wolf, H.2    Suess, C.3
  • 11
    • 0019364103 scopus 로고
    • The effect of mAs variation upon computed tomography image quality as evaluated by in vivo and in vitro studies
    • Haaga JR, Miraldi F, MacIntyre W, LiPuma JP, Bryan PJ, Wiesen E. The effect of mAs variation upon computed tomography image quality as evaluated by in vivo and in vitro studies. Radiology 1981;138(2):449-454. (Pubitemid 11179610)
    • (1981) Radiology , vol.138 , Issue.2 , pp. 449-454
    • Haaga, J.R.1    Miraldi, F.2    MacIntyre, W.3
  • 12
    • 70349571711 scopus 로고    scopus 로고
    • Radiation dose reduction in time-resolved CT angiography using highly constrained back projection reconstruction
    • Supanich M, Tao Y, Nett B, et al. Radiation dose reduction in time-resolved CT angiography using highly constrained back projection reconstruction. Phys Med Biol 2009;54(14):4575-4593.
    • (2009) Phys Med Biol , vol.54 , Issue.14 , pp. 4575-4593
    • Supanich, M.1    Tao, Y.2    Nett, B.3
  • 13
    • 75349092506 scopus 로고    scopus 로고
    • Low-tube-voltage, high-tube-current multidetector abdominal CT: Improved image quality and decreased radiation dose with adaptive statistical iterative reconstruction algorithm - Initial clinical experience
    • Marin D, Nelson RC, Schindera ST, et al. Low-tube-voltage, high-tube-current multidetector abdominal CT: improved image quality and decreased radiation dose with adaptive statistical iterative reconstruction algorithm - initial clinical experience. Radiology 2010;254(1):145-153.
    • (2010) Radiology , vol.254 , Issue.1 , pp. 145-153
    • Marin, D.1    Nelson, R.C.2    Schindera, S.T.3
  • 14
    • 77949865226 scopus 로고    scopus 로고
    • Reducing abdominal CT radiation dose with adaptive statistical iterative reconstruction technique
    • Prakash P, Kalra MK, Kambadakone AK, et al. Reducing abdominal CT radiation dose with adaptive statistical iterative reconstruction technique. Invest Radiol 2010;45(4):202-210.
    • (2010) Invest Radiol , vol.45 , Issue.4 , pp. 202-210
    • Prakash, P.1    Kalra, M.K.2    Kambadakone, A.K.3
  • 15
    • 74749087439 scopus 로고    scopus 로고
    • Innovations in CT dose reduction strategy: Application of the adaptive statistical iterative reconstruction algorithm
    • Silva AC, Lawder HJ, Hara A, Kujak J, Pavlicek W. Innovations in CT dose reduction strategy: application of the adaptive statistical iterative reconstruction algorithm. AJR Am J Roentgenol 2010;194(1):191-199.
    • (2010) AJR Am J Roentgenol , vol.194 , Issue.1 , pp. 191-199
    • Silva, A.C.1    Lawder, H.J.2    Hara, A.3    Kujak, J.4    Pavlicek, W.5
  • 16
    • 35649025312 scopus 로고    scopus 로고
    • A three-dimensional statistical approach to improved image quality for multislice helical CT
    • DOI 10.1118/1.2789499
    • Thibault JB, Sauer KD, Bouman CA, Hsieh J. A three-dimensional statistical approach to improved image quality for multislice helical CT. Med Phys 2007;34(11):4526-4544. (Pubitemid 350029675)
    • (2007) Medical Physics , vol.34 , Issue.11 , pp. 4526-4544
    • Thibault, J.-B.1    Sauer, K.D.2    Bouman, C.A.3    Hsieh, J.4
  • 17
    • 38849164794 scopus 로고    scopus 로고
    • Prior image constrained compressed sensing (PICCS): A method to accurately reconstruct dynamic CT images from highly undersampled projection data sets
    • DOI 10.1118/1.2836423
    • Chen GH, Tang J, Leng S. Prior image constrained compressed sensing (PICCS): a method to accurately reconstruct dynamic CT images from highly undersampled projection data sets. Med Phys 2008;35(2):660-663. (Pubitemid 351190885)
    • (2008) Medical Physics , vol.35 , Issue.2 , pp. 660-663
    • Chen, G.-H.1    Tang, J.2    Leng, S.3
  • 18
    • 77955813464 scopus 로고    scopus 로고
    • Prior image constrained compressed sensing (PICCS) and applications in x-ray computed tomography
    • Chen GH, Tang J, Nett B, Qi Z, Leng S, Szczykutowicz T. Prior image constrained compressed sensing (PICCS) and applications in x-ray computed tomography. Curr Med Imaging Rev 2010;6(2):119-134.
    • (2010) Curr Med Imaging Rev , vol.6 , Issue.2 , pp. 119-134
    • Chen, G.H.1    Tang, J.2    Nett, B.3    Qi, Z.4    Leng, S.5    Szczykutowicz, T.6
  • 19
    • 34648819024 scopus 로고    scopus 로고
    • Effective dose determination using an anthropomorphic phantom and metal oxide semiconductor field effect transistor technology for clinical adult body multidetector array computed tomography protocols
    • DOI 10.1097/RCT.0b013e31802d3dd2, PII 0000472820070700000009
    • Hurwitz LM, Yoshizumi TT, Goodman PC, et al. Effective dose determination using an anthropomorphic phantom and metal oxide semiconductor field effect transistor technology for clinical adult body multidetector array computed tomography protocols. J Comput Assist Tomogr 2007;31(4):544-549. (Pubitemid 47457667)
    • (2007) Journal of Computer Assisted Tomography , vol.31 , Issue.4 , pp. 544-549
    • Hurwitz, L.M.1    Yoshizumi, T.T.2    Goodman, P.C.3    Frush, D.P.4    Nguyen, G.5    Toncheva, G.6    Lowry, C.7
  • 20
    • 4644221703 scopus 로고    scopus 로고
    • Sixteen-detector row CT of abdomen and pelvis: Study for optimization of z-axis modulation technique performed in 153 patients
    • DOI 10.1148/radiol.2331031505
    • Kalra MK, Maher MM, Kamath RS, et al. Sixteen-detector row CT of abdomen and pelvis: study for optimization of z-axis modulation technique performed in 153 patients. Radiology 2004;233(1):241-249. (Pubitemid 39280980)
    • (2004) Radiology , vol.233 , Issue.1 , pp. 241-249
    • Kalra, M.K.1    Maher, M.M.2    Kamath, R.S.3    Horiuchi, T.4    Toth, T.L.5    Halpern, E.F.6    Saini, S.7
  • 21
    • 77954708865 scopus 로고    scopus 로고
    • Reducing the radiation dose for CT colonography using adaptive statistical iterative reconstruction: A pilot study
    • Flicek KT, Hara AK, Silva AC, Wu Q, Peter MB, Johnson CD. Reducing the radiation dose for CT colonography using adaptive statistical iterative reconstruction: a pilot study. AJR Am J Roentgenol 2010;195(1):126-131.
    • (2010) AJR Am J Roentgenol , vol.195 , Issue.1 , pp. 126-131
    • Flicek, K.T.1    Hara, A.K.2    Silva, A.C.3    Wu, Q.4    Peter, M.B.5    Johnson, C.D.6
  • 22
    • 77649173768 scopus 로고
    • Longitudinal data analysis using generalized linear models
    • Liang KY, Zeger SL. Longitudinal data analysis using generalized linear models. Biometrika 1986;73:13-22.
    • (1986) Biometrika , vol.73 , pp. 13-22
    • Liang, K.Y.1    Zeger, S.L.2
  • 23
    • 70149113077 scopus 로고    scopus 로고
    • R Development Core Team. Vienna, Austria: R Foundation for Statistical Computing
    • R Development Core Team. R: a language and environment for statistical computing. Vienna, Austria: R Foundation for Statistical Computing, 2009.
    • (2009) R: A Language and Environment for Statistical Computing
  • 24
    • 72049098502 scopus 로고    scopus 로고
    • ACR Colon Cancer Committee white paper: Status of CT colonography 2009
    • McFarland EG, Fletcher JG, Pickhardt P, et al. ACR Colon Cancer Committee white paper: status of CT colonography 2009. J Am Coll Radio l 2009;6(11):756-772.e4.
    • (2009) J Am Coll Radiol , vol.6 , Issue.11
    • McFarland, E.G.1    Fletcher, J.G.2    Pickhardt, P.3
  • 26
    • 42949177399 scopus 로고    scopus 로고
    • Screening and surveillance for the early detection of colorectal cancer and adenomatous polyps, 2008: A joint guideline from the American Cancer Society, the US Multi-Society Task Force on Colorectal Cancer, and the American College of Radiology
    • Levin B, Lieberman DA, McFarland B, et al. Screening and surveillance for the early detection of colorectal cancer and adenomatous polyps, 2008: a joint guideline from the American Cancer Society, the US Multi-Society Task Force on Colorectal Cancer, and the American College of Radiology. CA Cancer J Clin 2008;58(3):130-160.
    • (2008) CA Cancer J Clin , vol.58 , Issue.3 , pp. 130-160
    • Levin, B.1    Lieberman, D.A.2    McFarland, B.3
  • 28
    • 34249071667 scopus 로고    scopus 로고
    • Cost-effectiveness of colorectal cancer screening with computed tomography colonography: The impact of not reporting diminutive lesions
    • DOI 10.1002/cncr.22668
    • Pickhardt PJ, Hassan C, Laghi A, Zullo A, Kim DH, Morini S. Cost-effectiveness of colorectal cancer screening with computed tomography colonography: the impact of not reporting diminutive lesions. Cancer 2007;109(11):2213-2221. (Pubitemid 46801550)
    • (2007) Cancer , vol.109 , Issue.11 , pp. 2213-2221
    • Pickhardt, P.J.1    Hassan, C.2    Laghi, A.3    Zullo, A.4    Kim, D.H.5    Morini, S.6
  • 29
    • 77952310162 scopus 로고    scopus 로고
    • Evaluation of image quality and lesion perception by human readers on 3D CT colonography: Comparison of standard and low radiation dose
    • Fisichella VA, Båth M, Allansdotter Johnsson A, et al. Evaluation of image quality and lesion perception by human readers on 3D CT colonography: comparison of standard and low radiation dose. Eur Radiol 2010;20(3):630-639.
    • (2010) Eur Radiol , vol.20 , Issue.3 , pp. 630-639
    • Fisichella, V.A.1    Båth, M.2    Allansdotter Johnsson, A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.