메뉴 건너뛰기




Volumn 18, Issue S1, 2014, Pages S43-S47

How can dialyzer designs improve solute clearances for hemodialysis patients?

Author keywords

Adsorption; Dialyzer; Diffusion; Hemodiafiltration; Hemodialysis

Indexed keywords

POLYMER; POLYSULFONE; POVIDONE; DIALYSIS FLUID;

EID: 84910642358     PISSN: 14927535     EISSN: 15424758     Source Type: Journal    
DOI: 10.1111/hdi.12223     Document Type: Article
Times cited : (26)

References (36)
  • 1
    • 41949083941 scopus 로고    scopus 로고
    • History of haemodialyzers' design
    • Twardowski ZJ. History of haemodialyzers' design. Hemodial Int. 2008; 12:173-210.
    • (2008) Hemodial Int , vol.12 , pp. 173-210
    • Twardowski, Z.J.1
  • 2
    • 0001682993 scopus 로고
    • Development of parallel flow artificial kidney
    • Kiil F. Development of parallel flow artificial kidney. Acta Chir Scand. 1960; (Suppl 253):142-150.
    • (1960) Acta Chir Scand , pp. 142-150
    • Kiil, F.1
  • 4
    • 0000640950 scopus 로고
    • Does membrane biocompatibility effect cardiovascular stability in critically ill patients treated by machine haemofiltration?
    • Davenport A, Davison AM, Will EJ. Does membrane biocompatibility effect cardiovascular stability in critically ill patients treated by machine haemofiltration? Kidney Int. 1993; 43(Suppl 41):S230-S234.
    • (1993) Kidney Int. , vol.43 , pp. S230-S234
    • Davenport, A.1    Davison, A.M.2    Will, E.J.3
  • 5
    • 0028129728 scopus 로고
    • Biocompatible membranes in acute renal failure: Prospective case-controlled study
    • Schiffl H, Lang SM, König A, Strasser T, Haider MC, Held E. Biocompatible membranes in acute renal failure: Prospective case-controlled study. Lancet. 1994; 344:570-572.
    • (1994) Lancet , vol.344 , pp. 570-572
    • Schiffl, H.1    Lang, S.M.2    König, A.3    Strasser, T.4    Haider, M.C.5    Held, E.6
  • 6
    • 70349983058 scopus 로고    scopus 로고
    • Can dialyzer membrane selection affect outcomes in patients with acute kidney injury requiring dialysis?
    • Davenport A. Can dialyzer membrane selection affect outcomes in patients with acute kidney injury requiring dialysis? Hemodial Int. 2009; 13(Suppl 1):S13-S17.
    • (2009) Hemodial Int , vol.13 , pp. S13-S17
    • Davenport, A.1
  • 7
    • 53349096953 scopus 로고    scopus 로고
    • The role of dialyzer membrane flux in bio-incompatibility
    • Davenport A. The role of dialyzer membrane flux in bio-incompatibility. Hemodial Int. 2008; 12(Suppl 2):S29-S33.
    • (2008) Hemodial Int , vol.12 , pp. S29-S33
    • Davenport, A.1
  • 8
    • 0036097466 scopus 로고    scopus 로고
    • Hemodialyzer: From macro-design to membrane nanostructure; the case of the FX-class of hemodialyzers
    • Ronco C, Bowry SK, Brendolan A, etal. Hemodialyzer: From macro-design to membrane nanostructure; the case of the FX-class of hemodialyzers. Kidney Int Suppl. 2002; 80:126-142.
    • (2002) Kidney Int Suppl , vol.80 , pp. 126-142
    • Ronco, C.1    Bowry, S.K.2    Brendolan, A.3
  • 9
    • 0025650083 scopus 로고
    • The effect of the direction of dialysate flow on the efficiency of CAVHD
    • Davenport A, Will EJ, Davison AM. The effect of the direction of dialysate flow on the efficiency of CAVHD. Blood Purif. 1990; 8:329-336.
    • (1990) Blood Purif , vol.8 , pp. 329-336
    • Davenport, A.1    Will, E.J.2    Davison, A.M.3
  • 10
    • 33746852029 scopus 로고    scopus 로고
    • Dialyzer clearances and mass transfer-area coefficients for small solutes at low dialysate flow rates
    • Leypoldt JK, Kamerath CD, Gilson JF, Friederichs G. Dialyzer clearances and mass transfer-area coefficients for small solutes at low dialysate flow rates. ASAIO J. 2006; 52:404-409.
    • (2006) ASAIO J , vol.52 , pp. 404-409
    • Leypoldt, J.K.1    Kamerath, C.D.2    Gilson, J.F.3    Friederichs, G.4
  • 11
    • 77953526220 scopus 로고    scopus 로고
    • Membrane designs and composition for hemodialysis, hemofiltration and hemodialfiltration: Past, present and future
    • Davenport A. Membrane designs and composition for hemodialysis, hemofiltration and hemodialfiltration: Past, present and future. Minerva Urol Nefrol. 2010; 62:29-40.
    • (2010) Minerva Urol Nefrol , vol.62 , pp. 29-40
    • Davenport, A.1
  • 13
    • 84863194535 scopus 로고    scopus 로고
    • Computational modeling of effects of mechanical shaking on hemodynamics in hollow fibers
    • Kim JC, Garzotto F, Cruz DN, etal. Computational modeling of effects of mechanical shaking on hemodynamics in hollow fibers. Int J Artif Organs. 2012; 35:301-307.
    • (2012) Int J Artif Organs , vol.35 , pp. 301-307
    • Kim, J.C.1    Garzotto, F.2    Cruz, D.N.3
  • 14
    • 67449141668 scopus 로고    scopus 로고
    • Beta2-microglobulin and phosphate clearances using a wearable artificial kidney: A pilot study
    • Gura V, Davenport A, Beizai M, Ezon C, Ronco C. Beta2-microglobulin and phosphate clearances using a wearable artificial kidney: A pilot study. Am J Kidney Dis. 2009; 54:104-111.
    • (2009) Am J Kidney Dis , vol.54 , pp. 104-111
    • Gura, V.1    Davenport, A.2    Beizai, M.3    Ezon, C.4    Ronco, C.5
  • 15
    • 84864690447 scopus 로고    scopus 로고
    • Experimental evaluation of flow and dialysis performance of hollow-fiber dialyzers with different packing densities
    • Hirano A, Kida S, Yamamoto K, Sakai K. Experimental evaluation of flow and dialysis performance of hollow-fiber dialyzers with different packing densities. J Artif Organs. 2012; 15:168-175.
    • (2012) J Artif Organs , vol.15 , pp. 168-175
    • Hirano, A.1    Kida, S.2    Yamamoto, K.3    Sakai, K.4
  • 16
    • 0034868776 scopus 로고    scopus 로고
    • Increases in mass transfer-area coefficients and urea Kt/V with increasing dialysate flow rate are greater for high-flux dialyzers
    • Leypoldt JK, Cheung AK. Increases in mass transfer-area coefficients and urea Kt/V with increasing dialysate flow rate are greater for high-flux dialyzers. Am J Kidney Dis. 2001; 38:575-579.
    • (2001) Am J Kidney Dis , vol.38 , pp. 575-579
    • Leypoldt, J.K.1    Cheung, A.K.2
  • 17
    • 80052579441 scopus 로고    scopus 로고
    • Dialysate flow rate and delivered Kt/Vurea for dialyzers with enhanced dialysate flow distribution
    • Ward RA, Idoux JW, Hamdan H, Ouseph R, Depner TA, Golper TA. Dialysate flow rate and delivered Kt/Vurea for dialyzers with enhanced dialysate flow distribution. Clin J Am Soc Nephrol. 2011; 6:2235-2239.
    • (2011) Clin J Am Soc Nephrol , vol.6 , pp. 2235-2239
    • Ward, R.A.1    Idoux, J.W.2    Hamdan, H.3    Ouseph, R.4    Depner, T.A.5    Golper, T.A.6
  • 18
    • 79251537796 scopus 로고    scopus 로고
    • Evaluation of dialyzer jacket structure and hollow-fiber dialysis membranes to achieve high dialysis performance
    • Hirano A, Yamamoto K, Matsuda M, etal. Evaluation of dialyzer jacket structure and hollow-fiber dialysis membranes to achieve high dialysis performance. Ther Apher Dial. 2011; 15:66-74.
    • (2011) Ther Apher Dial , vol.15 , pp. 66-74
    • Hirano, A.1    Yamamoto, K.2    Matsuda, M.3
  • 19
    • 66449096594 scopus 로고    scopus 로고
    • Computational evaluation of dialysis fluid flow in dialyzers with variously designed jackets
    • Yamamoto K, Matsuda M, Hirano A, etal. Computational evaluation of dialysis fluid flow in dialyzers with variously designed jackets. Artif Organs. 2009; 33:481-486.
    • (2009) Artif Organs , vol.33 , pp. 481-486
    • Yamamoto, K.1    Matsuda, M.2    Hirano, A.3
  • 20
    • 84869215762 scopus 로고    scopus 로고
    • New high-cutoff dialyzer allows improved middle molecule clearance without an increase in albumin loss: A clinical crossover comparison in extended dialysis
    • Schmidt JJ, Hafer C, Clajus C, etal. New high-cutoff dialyzer allows improved middle molecule clearance without an increase in albumin loss: A clinical crossover comparison in extended dialysis. Blood Purif. 2012; 34:246-252.
    • (2012) Blood Purif , vol.34 , pp. 246-252
    • Schmidt, J.J.1    Hafer, C.2    Clajus, C.3
  • 21
    • 58149177638 scopus 로고    scopus 로고
    • Serum free-light chain removal by high cutoff hemodialysis: Optimizing removal and supportive care
    • Hutchison CA, Harding S, Mead G, etal. Serum free-light chain removal by high cutoff hemodialysis: Optimizing removal and supportive care. Artif Organs. 2008; 32:910-917.
    • (2008) Artif Organs , vol.32 , pp. 910-917
    • Hutchison, C.A.1    Harding, S.2    Mead, G.3
  • 22
    • 80054960787 scopus 로고    scopus 로고
    • Role of dialysis technology in the removal of uremic toxins
    • Davenport A. Role of dialysis technology in the removal of uremic toxins. Hemodial Int. 2011; 15(Suppl 1):S49-S53.
    • (2011) Hemodial Int , vol.15 , pp. S49-S53
    • Davenport, A.1
  • 23
    • 72949119098 scopus 로고    scopus 로고
    • Protein-bound uraemic toxin removal in haemodialysis and post-dilution haemodiafiltration
    • Krieter DH, Hackl A, Rodriguez A, etal. Protein-bound uraemic toxin removal in haemodialysis and post-dilution haemodiafiltration. Nephrol Dial Transplant. 2010; 25:212-218.
    • (2010) Nephrol Dial Transplant , vol.25 , pp. 212-218
    • Krieter, D.H.1    Hackl, A.2    Rodriguez, A.3
  • 24
    • 78149298714 scopus 로고    scopus 로고
    • Dialyzers designed to increase internal filtration do not result in significantly increased platelet activation and thrombin generation
    • Vernon K, Peasegood J, Riddell A, Davenport A. Dialyzers designed to increase internal filtration do not result in significantly increased platelet activation and thrombin generation. Nephron Clin Pract. 2011; 117:c403-c408.
    • (2011) Nephron Clin Pract , vol.117 , pp. c403-c408
    • Vernon, K.1    Peasegood, J.2    Riddell, A.3    Davenport, A.4
  • 25
    • 84858407902 scopus 로고    scopus 로고
    • Improvement of blood compatibility on polysulfone-polyvinylpyrrolidone blend films as a model membrane of dialyzer by physical adsorption of recombinant soluble human thrombomodulin (ART-123)
    • Omichi M, Matsusaki M, Maruyama I, Akashi M. Improvement of blood compatibility on polysulfone-polyvinylpyrrolidone blend films as a model membrane of dialyzer by physical adsorption of recombinant soluble human thrombomodulin (ART-123). J Biomater Sci Polym Ed. 2012; 23:593-608.
    • (2012) J Biomater Sci Polym Ed , vol.23 , pp. 593-608
    • Omichi, M.1    Matsusaki, M.2    Maruyama, I.3    Akashi, M.4
  • 26
    • 84874615642 scopus 로고    scopus 로고
    • Online haemodiafiltration: Definition, dose quantification and safety revisited
    • EUDIAL group
    • Tattersall JE, Ward RA, EUDIAL group. Online haemodiafiltration: Definition, dose quantification and safety revisited. Nephrol Dial Transplant. 2013; 28:542-550.
    • (2013) Nephrol Dial Transplant , vol.28 , pp. 542-550
    • Tattersall, J.E.1    Ward, R.A.2
  • 27
    • 80054918065 scopus 로고    scopus 로고
    • Does online hemodiafiltration lead to reduction in trace elements and vitamins?
    • Cross J, Davenport A. Does online hemodiafiltration lead to reduction in trace elements and vitamins? Hemodial Int. 2011; 15:509-514.
    • (2011) Hemodial Int , vol.15 , pp. 509-514
    • Cross, J.1    Davenport, A.2
  • 28
    • 9644294204 scopus 로고    scopus 로고
    • Short bacterial DNA fragments: Detection in dialysate and induction of cytokines
    • Schindler R, Beck W, Deppisch R, etal. Short bacterial DNA fragments: Detection in dialysate and induction of cytokines. J Am Soc Nephrol. 2004; 15:3207-3214.
    • (2004) J Am Soc Nephrol , vol.15 , pp. 3207-3214
    • Schindler, R.1    Beck, W.2    Deppisch, R.3
  • 29
    • 84866045427 scopus 로고    scopus 로고
    • Targeted complement inhibition as a promising strategy for preventing inflammatory complications in hemodialysis
    • DeAngelis RA, Reis ES, Ricklin D, Lambris JD. Targeted complement inhibition as a promising strategy for preventing inflammatory complications in hemodialysis. Immunobiology. 2012; 217:1097-1105.
    • (2012) Immunobiology , vol.217 , pp. 1097-1105
    • DeAngelis, R.A.1    Reis, E.S.2    Ricklin, D.3    Lambris, J.D.4
  • 30
    • 80054938445 scopus 로고    scopus 로고
    • Optimization of heparin anticoagulation for haemodialysis
    • Davenport A. Optimization of heparin anticoagulation for haemodialysis. Hemodial Int. 2011; 15(Suppl 1):S43-S48.
    • (2011) Hemodial Int , vol.15 , pp. S43-S48
    • Davenport, A.1
  • 31
    • 23044433339 scopus 로고    scopus 로고
    • Assessment of the heparin-binding AN69 ST hemodialysis membrane: II. Clinical studies without heparin administration
    • Lavaud S, Paris B, Maheut H, etal. Assessment of the heparin-binding AN69 ST hemodialysis membrane: II. Clinical studies without heparin administration. ASAIO J. 2005; 51:348-351.
    • (2005) ASAIO J , vol.51 , pp. 348-351
    • Lavaud, S.1    Paris, B.2    Maheut, H.3
  • 32
    • 0038188607 scopus 로고    scopus 로고
    • Peroxynitrite-induced oxidation of plasma lipids is enhanced in stable haemodialysis patients
    • Ferraro B, Galli F, Frei B, etal. Peroxynitrite-induced oxidation of plasma lipids is enhanced in stable haemodialysis patients. Kidney Int. 2003; 63:2207-2213.
    • (2003) Kidney Int , vol.63 , pp. 2207-2213
    • Ferraro, B.1    Galli, F.2    Frei, B.3
  • 33
    • 11244335570 scopus 로고    scopus 로고
    • Vitamin E-coated dialyzer membranes down regulate expression of monocyte adhesion and co-stimulatory molecules
    • Betjes MG, Hoekstra FM, Klepper M, Postma SM, Vaessen LM. Vitamin E-coated dialyzer membranes down regulate expression of monocyte adhesion and co-stimulatory molecules. Blood Purif. 2004; 22:510-517.
    • (2004) Blood Purif , vol.22 , pp. 510-517
    • Betjes, M.G.1    Hoekstra, F.M.2    Klepper, M.3    Postma, S.M.4    Vaessen, L.M.5
  • 34
    • 84881026236 scopus 로고    scopus 로고
    • Mixed matrix hollow fiber membranes for removal of protein-bound toxins from human plasma
    • Tijink MS, Wester M, Glorieux G, etal. Mixed matrix hollow fiber membranes for removal of protein-bound toxins from human plasma. Biomaterials. 2013; 34:7819-7828.
    • (2013) Biomaterials , vol.34 , pp. 7819-7828
    • Tijink, M.S.1    Wester, M.2    Glorieux, G.3
  • 35
    • 84861457767 scopus 로고    scopus 로고
    • Urea separation in flat-plate microchannel hemodialyzer; experiment and modelling
    • Tuhy AR, Anderson EK, Jovanovic GN. Urea separation in flat-plate microchannel hemodialyzer; experiment and modelling. Biomed Microdevices. 2012; 14:595-602.
    • (2012) Biomed Microdevices , vol.14 , pp. 595-602
    • Tuhy, A.R.1    Anderson, E.K.2    Jovanovic, G.N.3
  • 36
    • 33645313451 scopus 로고    scopus 로고
    • Intradialytic complications during haemodialysis
    • Davenport A. Intradialytic complications during haemodialysis. Hemodial Int. 2006; 10:162-167.
    • (2006) Hemodial Int , vol.10 , pp. 162-167
    • Davenport, A.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.