메뉴 건너뛰기




Volumn 12, Issue SUPPL. 2, 2008, Pages

The role of dialyzer membrane flux in bio-incompatibility

Author keywords

Biocompatibility; Dialyzer; Membrane flux

Indexed keywords

BETA 2 MICROGLOBULIN; CELLULOSE; CUPROPHANE; POLYAMIDE;

EID: 53349096953     PISSN: 14927535     EISSN: 15424758     Source Type: Journal    
DOI: 10.1111/j.1542-4758.2008.00321.x     Document Type: Conference Paper
Times cited : (15)

References (31)
  • 1
    • 0014429327 scopus 로고
    • Profound neutropenia during the early phase of hemodialysis
    • Kaplow LS, Goffinet JA. Profound neutropenia during the early phase of hemodialysis. JAMA. 1968; 203:1135-1137.
    • (1968) JAMA , vol.203 , pp. 1135-1137
    • Kaplow, L.S.1    Goffinet, J.A.2
  • 2
    • 0017413401 scopus 로고
    • Hemodialysis leukopenia. Pulmonary vascular leukostasis resulting from complement activation by dialyzer cellophane membranes
    • Craddock PR, Fehr J, Dalmasso AP, Brighan KL, Jacob HS. Hemodialysis leukopenia. Pulmonary vascular leukostasis resulting from complement activation by dialyzer cellophane membranes. J Clin Invest. 1977; 59:879-888.
    • (1977) J Clin Invest. , vol.59 , pp. 879-888
    • Craddock, P.R.1    Fehr, J.2    Dalmasso, A.P.3    Brighan, K.L.4    Jacob, H.S.5
  • 4
    • 0023906171 scopus 로고
    • The effect of reuse of cuprophan dialysers on dialysis induced leukopenia and thrombocytopenia
    • Davenport A, Ahmad R. The effect of reuse of cuprophan dialysers on dialysis induced leukopenia and thrombocytopenia. Dial Transplant. 1988; 17:132-134.
    • (1988) Dial Transplant , vol.17 , pp. 132-134
    • Davenport, A.1    Ahmad, R.2
  • 5
    • 33645313451 scopus 로고    scopus 로고
    • Intradialytic complications during hemodialysis
    • Davenport A. Intradialytic complications during hemodialysis. Hemodial Int. 2006; 10:162-167.
    • (2006) Hemodial Int. , vol.10 , pp. 162-167
    • Davenport, A.1
  • 6
    • 21044444625 scopus 로고    scopus 로고
    • Biocompatibility parameters of different dialysis membranes assessed during systemic inflammation
    • Gueler F, Gwinner W, Schiborr C, et al. Biocompatibility parameters of different dialysis membranes assessed during systemic inflammation. Blood Purif. 2005; 23:196-202.
    • (2005) Blood Purif. , vol.23 , pp. 196-202
    • Gueler, F.1    Gwinner, W.2    Schiborr, C.3
  • 7
    • 33750849573 scopus 로고    scopus 로고
    • Comparative evaluation of oxidative and antioxidative capacity during high-flux hemodialysis using two different membranes
    • Schönermarck U, Dengler C, Ebeling F, Heydenreich M, Hillebrand GF, Samtleben W. Comparative evaluation of oxidative and antioxidative capacity during high-flux hemodialysis using two different membranes. Clin Nephrol. 2006; 66:357-363.
    • (2006) Clin Nephrol. , vol.66 , pp. 357-363
    • Schönermarck, U.1    Dengler, C.2    Ebeling, F.3    Heydenreich, M.4    Hillebrand, G.F.5    Samtleben, W.6
  • 8
    • 33645295460 scopus 로고    scopus 로고
    • Does an alteration of dialyzer design and geometry affect biocompatibility parameters?
    • Opatrný K Jr, Krouzzecký A, Polanská K, et al. Does an alteration of dialyzer design and geometry affect biocompatibility parameters? Hemodial Int. 2006; 10:201-208.
    • (2006) Hemodial Int. , vol.10 , pp. 201-208
    • Opatrný Jr., K.1    Krouzzecký, A.2    Polanská, K.3
  • 9
    • 33947306104 scopus 로고    scopus 로고
    • The impact of standard high-flux polysulfone versus novel high-flux polysulfone dialysis membranes on inflammatory markers: A randomized, single-blinded, controlled clinical trial
    • Kerr PG, Sutherland WH, de Jong S, Vaithalingham I, Williams SM, Walker RJ. The impact of standard high-flux polysulfone versus novel high-flux polysulfone dialysis membranes on inflammatory markers: A randomized, single-blinded, controlled clinical trial. Am J Kidney Dis. 2007; 49:533-539.
    • (2007) Am J Kidney Dis. , vol.49 , pp. 533-539
    • Kerr, P.G.1    Sutherland, W.H.2    de Jong, S.3    Vaithalingham, I.4    Williams, S.M.5    Walker, R.J.6
  • 10
    • 0037679137 scopus 로고    scopus 로고
    • A switch to high-flux helixone membranes reverses suppressed interferon-gamma production in patients on low-flux dialysis
    • Lonnemann G, Novick D, Rubinstein M, Passlick-Deetjen J, Lang D, Dinarello CA. A switch to high-flux helixone membranes reverses suppressed interferon-gamma production in patients on low-flux dialysis. Blood Purif. 2003; 21:225-331.
    • (2003) Blood Purif. , vol.21 , pp. 225-331
    • Lonnemann, G.1    Novick, D.2    Rubinstein, M.3    Passlick-Deetjen, J.4    Lang, D.5    Dinarello, C.A.6
  • 11
    • 0027946293 scopus 로고
    • Effect of the dialysis membrane in the treatment of patients with acute renal failure
    • Hakim RM, Wingard RL, Parker RA. Effect of the dialysis membrane in the treatment of patients with acute renal failure. N Engl J Med. 1994; 331:1338-1342.
    • (1994) N Engl J Med. , vol.331 , pp. 1338-1342
    • Hakim, R.M.1    Wingard, R.L.2    Parker, R.A.3
  • 12
    • 0028129728 scopus 로고
    • Biocompatible membranes in acute renal failure: Prospective case-controlled study
    • Schiffl H, Lang SM, König A, Strasser T, Haider MC, Held E. Biocompatible membranes in acute renal failure: Prospective case-controlled study. Lancet. 1994; 344:570-572.
    • (1994) Lancet , vol.344 , pp. 570-572
    • Schiffl, H.1    Lang, S.M.2    König, A.3    Strasser, T.4    Haider, M.C.5    Held, E.6
  • 14
    • 0029063471 scopus 로고
    • Is the choice of membrane important for patients with acute renal failure requiring hemodialysis?
    • Kurtal H, von Herrath D, Schaefer K. Is the choice of membrane important for patients with acute renal failure requiring hemodialysis? Artif Organs. 1995; 19:391-394.
    • (1995) Artif Organs , vol.19 , pp. 391-394
    • Kurtal, H.1    von Herrath, D.2    Schaefer, K.3
  • 15
    • 0028088266 scopus 로고
    • Risk factors influencing survival in ICU acute renal failure
    • Cosentino F, Chaff C, Piedmonte M. Risk factors influencing survival in ICU acute renal failure. Nephrol Dial Transplant. 1994; 9(Suppl 4):179-182.
    • (1994) Nephrol Dial Transplant , vol.9 , Issue.SUPPL. 4 , pp. 179-182
    • Cosentino, F.1    Chaff, C.2    Piedmonte, M.3
  • 16
    • 0344979750 scopus 로고    scopus 로고
    • Hemodialysis-membrane biocompatibility and mortality of patients with dialysis-dependent acute renal failure: A prospective randomised multicentre trial
    • International Multicentre Study Group
    • Jörres A, Gahl GM, Dobis C, et al. Hemodialysis-membrane biocompatibility and mortality of patients with dialysis-dependent acute renal failure: A prospective randomised multicentre trial. International Multicentre Study Group. Lancet. 1999; 354:1337-1341.
    • (1999) Lancet , vol.354 , pp. 1337-1341
    • Jörres, A.1    Gahl, G.M.2    Dobis, C.3
  • 17
    • 0033955875 scopus 로고    scopus 로고
    • Comparison of cellulose diacetate and polysulfone membranes in the outcome of acute renal failure. A prospective randomized study
    • Gastaldello K, Melot C, Kahn RJ, Vanherweghem JL, Vincent JL, Tielemans C. Comparison of cellulose diacetate and polysulfone membranes in the outcome of acute renal failure. A prospective randomized study. Nephrol Dial Transplant. 2000; 15:224-230.
    • (2000) Nephrol Dial Transplant , vol.15 , pp. 224-230
    • Gastaldello, K.1    Melot, C.2    Kahn, R.J.3    Vanherweghem, J.L.4    Vincent, J.L.5    Tielemans, C.6
  • 18
    • 0036406910 scopus 로고    scopus 로고
    • Influence of dialysis membranes on outcomes in acute renal failure: A meta-analysis
    • Subramanian S, Venkataraman R, Kellum JA. Influence of dialysis membranes on outcomes in acute renal failure: A meta-analysis. Kidney Int. 2002; 62:1819-1823.
    • (2002) Kidney Int. , vol.62 , pp. 1819-1823
    • Subramanian, S.1    Venkataraman, R.2    Kellum, J.A.3
  • 19
    • 21844468019 scopus 로고    scopus 로고
    • Biocompatible hemodialysis membranes for acute renal failure (Review)
    • Alonso A, Lau J, Jaber B. Biocompatible hemodialysis membranes for acute renal failure (Review). Cochrane Database Syst Rev. 2008; 23:CD005283.
    • (2008) Cochrane Database Syst Rev. , vol.23
    • Alonso, A.1    Lau, J.2    Jaber, B.3
  • 20
    • 44649090797 scopus 로고    scopus 로고
    • Delivery of renal replacement therapy in acute kidney injury: What are the key issues?
    • Davenport A, Bouman C, Kirpalani A, et al. Delivery of renal replacement therapy in acute kidney injury: What are the key issues? Clin J Am Soc Nephrol. 2008; 3:869-875.
    • (2008) Clin J Am Soc Nephrol. , vol.3 , pp. 869-875
    • Davenport, A.1    Bouman, C.2    Kirpalani, A.3
  • 21
    • 0029841840 scopus 로고    scopus 로고
    • Effect of the dialysis membrane on mortality of chronic hemodialysis patients
    • Hakim RM, Held PJ, Stannard DC, et al. Effect of the dialysis membrane on mortality of chronic hemodialysis patients. Kidney Int. 1996; 50:566-570.
    • (1996) Kidney Int. , vol.50 , pp. 566-570
    • Hakim, R.M.1    Held, P.J.2    Stannard, D.C.3
  • 22
    • 0032893206 scopus 로고    scopus 로고
    • Relationship of dialysis membrane and cause-specific mortality
    • Bloembergen WE, Hakim RM, Stannard DC, et al. Relationship of dialysis membrane and cause-specific mortality. Am J Kidney Dis. 1999; 33:1-10.
    • (1999) Am J Kidney Dis. , vol.33 , pp. 1-10
    • Bloembergen, W.E.1    Hakim, R.M.2    Stannard, D.C.3
  • 23
    • 0029919234 scopus 로고    scopus 로고
    • The effect of membrane biocompatibility on plasma beta2-microglobulin levels in chronic hemodialysis patients
    • Hakim RM, Wingard RL, Husni L, Parker RA, Parker TF III. The effect of membrane biocompatibility on plasma beta2-microglobulin levels in chronic hemodialysis patients. J Am Soc Nephrol. 1996; 7:472-478.
    • (1996) J Am Soc Nephrol. , vol.7 , pp. 472-478
    • Hakim, R.M.1    Wingard, R.L.2    Husni, L.3    Parker, R.A.4    Parker III, T.F.5
  • 24
    • 0030768433 scopus 로고    scopus 로고
    • Switch from conventional to high-flux membrane reduces the risk of carpal tunnel syndrome and mortality of hemodialysis patients
    • Koda Y, Nishi S, Miyazaki S, et al. Switch from conventional to high-flux membrane reduces the risk of carpal tunnel syndrome and mortality of hemodialysis patients. Kidney Int. 1997; 52:1096-1101.
    • (1997) Kidney Int. , vol.52 , pp. 1096-1101
    • Koda, Y.1    Nishi, S.2    Miyazaki, S.3
  • 25
    • 0030058767 scopus 로고    scopus 로고
    • Effect of the membrane biocompatibility on nutritional parameters in chronic hemodialysis patients
    • Parker TF III, Wingard RL, Husni L, Ikizler TA, Parker RA, Hakim RM. Effect of the membrane biocompatibility on nutritional parameters in chronic hemodialysis patients. Kidney Int. 1996; 49:551-556.
    • (1996) Kidney Int. , vol.49 , pp. 551-556
    • Parker, T.F.1    Wingard, R.L.2    Husni, L.3    Ikizler, T.A.4    Parker, R.A.5    Hakim, R.M.6
  • 26
    • 0035229396 scopus 로고    scopus 로고
    • Comparison of cellulose, modified cellulose and synthetic membranes in the haemodialysis of patients with end-stage renal disease (Review)
    • MacLeod A, Daly C, Khan I, et al. Comparison of cellulose, modified cellulose and synthetic membranes in the haemodialysis of patients with end-stage renal disease (Review). Cochrane Database Syst Rev. 2001; 3:CD003234.
    • (2001) Cochrane Database Syst Rev. , vol.3
    • MacLeod, A.1    Daly, C.2    Khan, I.3
  • 27
    • 33846638745 scopus 로고    scopus 로고
    • Dialyzer membrane characteristics and outcome of patients with type 2 diabetes on maintenance hemodialysis
    • Krane V, Krieter DH, Olschewski M, et al. Dialyzer membrane characteristics and outcome of patients with type 2 diabetes on maintenance hemodialysis. Am J Kidney Dis. 2007; 49:267-275.
    • (2007) Am J Kidney Dis. , vol.49 , pp. 267-275
    • Krane, V.1    Krieter, D.H.2    Olschewski, M.3
  • 28
    • 29244443414 scopus 로고    scopus 로고
    • Cerebrovascular disease in maintenance hemodialysis patients: Results of the HEMO Study
    • Hemodialysis (HEMO) Study Group
    • Delmez JA, Yan G, Bailey J, et al. Hemodialysis (HEMO) Study Group. Cerebrovascular disease in maintenance hemodialysis patients: Results of the HEMO Study. Am J Kidney Dis. 2006; 47:131-138.
    • (2006) Am J Kidney Dis. , vol.47 , pp. 131-138
    • Delmez, J.A.1    Yan, G.2    Bailey, J.3
  • 29
    • 33645460223 scopus 로고    scopus 로고
    • Serum beta-2 microglobulin levels predict mortality in dialysis patients: Results of the HEMO study
    • Cheung AK, Rocco MV, Yan G, et al. Serum beta-2 microglobulin levels predict mortality in dialysis patients: Results of the HEMO study. J Am Soc Nephrol. 2006; 17:546-555.
    • (2006) J Am Soc Nephrol. , vol.17 , pp. 546-555
    • Cheung, A.K.1    Rocco, M.V.2    Yan, G.3
  • 30
    • 0034839085 scopus 로고    scopus 로고
    • Effects of ultrapure dialysis fluid on nutritional status and inflammatory parameters
    • Schiffl H, Lang SM, Stratakis D, Fischer R. Effects of ultrapure dialysis fluid on nutritional status and inflammatory parameters. Nephrol Dial Transplant. 2001; 16:1863-1869.
    • (2001) Nephrol Dial Transplant , vol.16 , pp. 1863-1869
    • Schiffl, H.1    Lang, S.M.2    Stratakis, D.3    Fischer, R.4
  • 31
    • 0000640950 scopus 로고
    • Membrane biocompatibility: Effects on cardiovascular stability in patients on hemofiltration
    • Davenport A, Davison AM, Will EJ. Membrane biocompatibility: Effects on cardiovascular stability in patients on hemofiltration. Kidney Int. 1993; 41(Suppl):S230-S234.
    • (1993) Kidney Int. , vol.41 , Issue.SUPPL.
    • Davenport, A.1    Davison, A.M.2    Will, E.J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.