Comparison of four hematology analyzers, CELL-DYN Sapphire, ADVIA 120, Coulter LH 750, and Sysmex XE-2100, in terms of clinical usefulness
-
Kang SH, Kim HK, Ham CK, Lee DS, Cho HI. Comparison of four hematology analyzers, CELL-DYN Sapphire, ADVIA 120, Coulter LH 750, and Sysmex XE-2100, in terms of clinical usefulness. Int J Lab Hematol 2008;30:480-6.
-
(2008)
Int J Lab Hematol
, vol.30
, pp. 480-486
-
-
Kang, S.H.1
Kim, H.K.2
Ham, C.K.3
Lee, D.S.4
Cho, H.I.5
-
2
-
-
84878069332
-
Comparison of automated differential blood cell counts from abbott sapphire, siemens advia 120, beckman coulter dxh 800, and sysmex xe-2100 in normal and pathologic samples
-
Meintker L, Ringwald J, Rauh M, Krause SW. Comparison of automated differential blood cell counts from Abbott Sapphire, Siemens Advia 120, Beckman Coulter DxH 800, and Sysmex XE-2100 in normal and pathologic samples. Am J Clin Pathol 2013;139:641-50.
-
(2013)
Am J Clin Pathol
, vol.139
, pp. 641-650
-
-
Meintker, L.1
Ringwald, J.2
Rauh, M.3
Krause, S.W.4
-
3
-
-
79957687426
-
Evaluation of the beckman coulter unicel dxh 800, beckman coulter lh 780, and abbott diagnostics cell-dyn sapphire hematology analyzers on adult specimens in a tertiary care hospital
-
Tan BT, Nava AJ, George TI. Evaluation of the Beckman Coulter UniCel DxH 800, Beckman Coulter LH 780, and Abbott Diagnostics Cell-Dyn Sapphire hematology analyzers on adult specimens in a tertiary care hospital. Am J Clin Pathol 2011;135:939-51.
-
(2011)
Am J Clin Pathol
, vol.135
, pp. 939-951
-
-
Tan, B.T.1
Nava, A.J.2
George, T.I.3
-
4
-
-
84888217412
-
Performance and abnormal cell flagging comparisons of three automated blood cell counters: Cell-Dyn Sapphire, DxH-800, and XN-2000
-
Hotton J, Broothaers J, Swaelens C, Cantinieaux B. Performance and abnormal cell flagging comparisons of three automated blood cell counters: Cell-Dyn Sapphire, DxH-800, and XN-2000. Am J Clin Pathol 2013;140:845-52.
-
(2013)
Am J Clin Pathol
, vol.140
, pp. 845-852
-
-
Hotton, J.1
Broothaers, J.2
Swaelens, C.3
Cantinieaux, B.4
-
5
-
-
79959571426
-
Optimization of laboratory workflow in clinical hematology laboratory with reduced manual slide review: Comparison between Sysmex XE-2100 and ABX Pentra DX120
-
Hur M, Cho JH, Kim H, Hong MH, Moon HW, Yun YM, et al. Optimization of laboratory workflow in clinical hematology laboratory with reduced manual slide review: Comparison between Sysmex XE-2100 and ABX Pentra DX120. Int J Lab Hematol 2011;33:434-40.
-
(2011)
Int J Lab Hematol
, vol.33
, pp. 434-440
-
-
Hur, M.1
Cho, J.H.2
Kim, H.3
Hong, M.H.4
Moon, H.W.5
Yun, Y.M.6
-
6
-
-
84873296031
-
Comparison of the cytodiff flow cytometric leucocyte differential count system with the sysmex xe-2100 and beckman coulter unicel dxh 800
-
Park BG, Park CJ, Kim S, Yoon CH, Kim DH, Jang S, et al. Comparison of the Cytodiff flow cytometric leucocyte differential count system with the Sysmex XE-2100 and Beckman Coulter UniCel DxH 800. Int J Lab Hematol 2012;34:584-93.
-
(2012)
Int J Lab Hematol
, vol.34
, pp. 584-593
-
-
Park, B.G.1
Park, C.J.2
Kim, S.3
Yoon, C.H.4
Kim, D.H.5
Jang, S.6
-
7
-
-
84867903203
-
Performance evaluation of the Sysmex haematology XN modular system
-
Briggs C, Longair I, Kumar P, Singh D, Machin SJ. Performance evaluation of the Sysmex haematology XN modular system. J Clin Pathol 2012;65:1024-30.
-
(2012)
J Clin Pathol
, vol.65
, pp. 1024-1030
-
-
Briggs, C.1
Longair, I.2
Kumar, P.3
Singh, D.4
MacHin, S.J.5
-
8
-
-
84910114062
-
Performance evaluation of the new hematology analyzer Sysmex XN-series
-
doi: 10.1111/ijlh.12254. [Epub ahead of print 12 May 2014]
-
Seo JY, Lee ST, Kim SH. Performance evaluation of the new hematology analyzer Sysmex XN-series. Int J Lab Hematol 2014. doi: 10.1111/ijlh.12254. [Epub ahead of print 12 May 2014].
-
(2014)
Int J Lab Hematol
-
-
Seo, J.Y.1
Lee, S.T.2
Kim, S.H.3
-
9
-
-
84865544693
-
Evaluation of the leukocyte differential on a new automated flow cytometry hematology analyzer
-
Kim JE, Kim BR, Woo KS, Han JY. Evaluation of the leukocyte differential on a new automated flow cytometry hematology analyzer. Int J Lab Hematol 2012;34:547-50.
-
(2012)
Int J Lab Hematol
, vol.34
, pp. 547-550
-
-
Kim, J.E.1
Kim, B.R.2
Woo, K.S.3
Han, J.Y.4
-
10
-
-
84880387451
-
Comparison of the accuracy of noninvasive hemoglobin sensor (NBM-200) and portable hemoglobinometer (HemoCue) with an automated hematology analyzer (LH500) in blood donor screening
-
Kim MJ, Park Q, Kim MH, Shin JW, Kim HO. Comparison of the accuracy of noninvasive hemoglobin sensor (NBM-200) and portable hemoglobinometer (HemoCue) with an automated hematology analyzer (LH500) in blood donor screening. Ann Lab Med 2013;33:261-7.
-
(2013)
Ann Lab Med
, vol.33
, pp. 261-267
-
-
Kim, M.J.1
Park, Q.2
Kim, M.H.3
Shin, J.W.4
Kim, H.O.5
-
11
-
-
84872261470
-
Evaluation of CytoDiff™ on cord blood WBC differential
-
Gac F, Thibert JB, Le Berre C, Le Priol J, Semana G, Fest T, et al. Evaluation of CytoDiff™ on cord blood WBC differential. Int J Lab Hematol 2013;35:46-54.
-
(2013)
Int J Lab Hematol
, vol.35
, pp. 46-54
-
-
Gac, F.1
Thibert, J.B.2
Le Berre, C.3
Le Priol, J.4
Semana, G.5
Fest, T.6
-
12
-
-
0032469504
-
Complete blood counts from umbilical cords of healthy term newborns by two automated cytometers
-
Walka MM, Sonntag J, Kage A, Dudenhausen JW, Obladen M. Complete blood counts from umbilical cords of healthy term newborns by two automated cytometers. Acta Haematol 1998; 100:167-73.
-
(1998)
Acta Haematol
, vol.100
, pp. 167-173
-
-
Walka, M.M.1
Sonntag, J.2
Kage, A.3
Dudenhausen, J.W.4
Obladen, M.5
-
13
-
-
80054698600
-
Evaluation of the nucleated red blood cell count in neonates using the Beckman Coulter UniCel DxH 800 analyzer
-
Kwon MJ, Nam MH, Kim SH, Lim CS, Lee CK, Cho Y, et al. Evaluation of the nucleated red blood cell count in neonates using the Beckman Coulter UniCel DxH 800 analyzer. Int J Lab Hematol 2011;33:620-8.
-
(2011)
Int J Lab Hematol
, vol.33
, pp. 620-628
-
-
Kwon, M.J.1
Nam, M.H.2
Kim, S.H.3
Lim, C.S.4
Lee, C.K.5
Cho, Y.6
-
14
-
-
84856605823
-
Umbilical cord blood as a replacement source for admission complete blood count in premature infants
-
Carroll PD, Nankervis CA, Iams J, Kelleher K. Umbilical cord blood as a replacement source for admission complete blood count in premature infants. J Perinatol 2012;32:97-102.
-
(2012)
J Perinatol
, vol.32
, pp. 97-102
-
-
Carroll, P.D.1
Nankervis, C.A.2
Iams, J.3
Kelleher, K.4
-
15
-
-
84887819398
-
Evaluation of ABX Pentra DX 120 and Sysmex XE-2100 in umbilical cord blood
-
Kim H, Hur M, Choi SG, Kim BH, Moon HW, Yun YM, et al. Evaluation of ABX Pentra DX 120 and Sysmex XE-2100 in umbilical cord blood. Int J Lab Hematol 2013;35:658-65.
-
(2013)
Int J Lab Hematol
, vol.35
, pp. 658-665
-
-
Kim, H.1
Hur, M.2
Choi, S.G.3
Kim, B.H.4
Moon, H.W.5
Yun, Y.M.6
-
16
-
-
0042667912
-
Principles of measurement in hematology analyzers manufactured by Sysmex Corporation
-
Fujimoto K. Principles of measurement in hematology analyzers manufactured by Sysmex Corporation. Sysmex J Int 1999;9:31-40.
-
(1999)
Sysmex J Int
, vol.9
, pp. 31-40
-
-
Fujimoto, K.1
-
17
-
-
84911806579
-
Spurious white blood cell count from a new automated Sysmex XN hematology analyzer
-
doi: 10.1111/ijlh.12200. [Epub ahead of print 14 Mar 2014]
-
Tantanate C. Spurious white blood cell count from a new automated Sysmex XN hematology analyzer. Int J Lab Hematol 2014. doi: 10.1111/ijlh.12200. [Epub ahead of print 14 Mar 2014].
-
(2014)
Int J Lab Hematol
-
-
Tantanate, C.1
-
21
-
-
84878024387
-
The usefulness of blast flags on the Sysmex XE-5000 is questionable
-
Eilertsen H, Vøllestad NK, Hagve TA. The usefulness of blast flags on the Sysmex XE-5000 is questionable. Am J Clin Pathol 2013;139:633-40.
-
(2013)
Am J Clin Pathol
, vol.139
, pp. 633-640
-
-
Eilertsen, H.1
Vøllestad, N.K.2
Hagve, T.A.3
-
22
-
-
0025325984
-
Interpretation of the correlation coefficient: A basic review
-
Taylor R. Interpretation of the correlation coefficient: A basic review. J Diagn Med Sonogr 1990;1:35-9.
-
(1990)
J Diagn Med Sonogr
, vol.1
, pp. 35-39
-
-
Taylor, R.1
-
23
-
-
84906937083
-
Performance evaluation of platelet counting by novel fluorescent dye staining in the XN-Series automated hematology analyzers
-
doi: 10.1002/jcla.21691. [Epub ahead of print 19 Mar 2014]
-
Tanaka Y, Tanaka Y, Gondo K, Maruki Y, Kondo T, Asai S, et al. Performance evaluation of platelet counting by novel fluorescent dye staining in the XN-Series automated hematology analyzers. J Clin Lab Anal 2014. doi: 10.1002/jcla.21691. [Epub ahead of print 19 Mar 2014].
-
(2014)
J Clin Lab Anal
-
-
Tanaka, Y.1
Tanaka, Y.2
Gondo, K.3
Maruki, Y.4
Kondo, T.5
Asai, S.6
-
25
-
-
84855264061
-
Is the blood basophil count sufficiently precise, accurate, and specific?: Three automated hematology instruments and flow cytometry compared
-
Amundsen EK, Henriksson CE, Holthe MR, Urdal P. Is the blood basophil count sufficiently precise, accurate, and specific?: Three automated hematology instruments and flow cytometry compared. Am J Clin Pathol 2012;137:86-92.
-
(2012)
Am J Clin Pathol
, vol.137
, pp. 86-92
-
-
Amundsen, E.K.1
Henriksson, C.E.2
Holthe, M.R.3
Urdal, P.4
-
26
-
-
79960974715
-
Improved flagging rates on the Sysmex XE-5000 compared with the XE-2100 reduce the number of manual film reviews and increase laboratory productivity
-
Briggs CJ, Linssen J, Longair I, Machin SJ. Improved flagging rates on the Sysmex XE-5000 compared with the XE-2100 reduce the number of manual film reviews and increase laboratory productivity. Am J Clin Pathol 2011;136:309-16.
-
(2011)
Am J Clin Pathol
, vol.136
, pp. 309-316
-
-
Briggs, C.J.1
Linssen, J.2
Longair, I.3
MacHin, S.J.4
-
27
-
-
0034935602
-
Hematologic and immunophenotypic characterization of human umbilical cord blood
-
Pranke P, Failace RR, Allebrandt WF, Steibel G, Schmidt F, Nardi NB. Hematologic and immunophenotypic characterization of human umbilical cord blood. Acta Haematol 2001;105:71-6.
-
(2001)
Acta Haematol
, vol.105
, pp. 71-76
-
-
Pranke, P.1
Failace, R.R.2
Allebrandt, W.F.3
Steibel, G.4
Schmidt, F.5
Nardi, N.B.6
|