Volumn 140, Issue 6, 2013, Pages 845-852

Performance and abnormal cell flagging comparisons of three automated blood cell counters

Author keywords

Abnormal lymphocytes; Blast; Cell Dyn Sapphire; DxH 800; Flag; HemaCAM; IG; NRBC; XN 2000

Indexed keywords

ANALYZER; ARTICLE; BLAST CELL; BLOOD CELL COUNT; CONTROLLED STUDY; CORRELATION ANALYSIS; ERYTHROCYTE; GRANULOCYTE; LYMPHOCYTE; MICROSCOPY; NEUTROPHIL; PREDICTIVE VALUE; PRIORITY JOURNAL; REPRODUCIBILITY; SENSITIVITY AND SPECIFICITY;

EID: 84888217412     PISSN: 00029173     EISSN: 19437722     Source Type: Journal    
DOI: 10.1309/AJCPE5R4SOQBUULZ     Document Type: Article
Times cited : (55)

References (14)
  • 1
    • 55149091790 scopus 로고    scopus 로고
    • Comparison of four hematology analyzers, CELL-DYN sapphire, ADVIA 120, coulter LH750, and sysmex XE-2100, in terms of clinical usefulness
    • Kang S-H, Kim HK, Ham CK, et al. Comparison of four hematology analyzers, CELL-DYN Sapphire, ADVIA 120, Coulter LH750, and Sysmex XE-2100, in terms of clinical usefulness. Int J Lab Hematol. 2008;30:480-486
    • (2008) Int J Lab Hematol. , vol.30 , pp. 480-486
    • Kang, S.-H.1    Kim, H.K.2    Ham, C.K.3
  • 5
    • 27444443069 scopus 로고    scopus 로고
    • Performance evaluation of the cellavision DM96 system
    • Kratz A, Bengtsson H-I, Casey J, et al. Performance evaluation of the CellaVision DM96 system. Am J Clin Pathol. 2005;124:770-781
    • (2005) Am J Clin Pathol. , vol.124 , pp. 770-781
    • Kratz, A.1    Bengtsson, H.-I.2    Casey, J.3
  • 6
    • 84888213009 scopus 로고    scopus 로고
    • Evaluation of a new method for the enumeration of nucleated red blood cells on the new sysmex XN automated hematology analyzer
    • PM52
    • Rosenthal N, Connell B, Brown B, et al. Evaluation of a new method for the enumeration of Nucleated Red Blood Cells on the new Sysmex XN Automated Hematology Analyzer. Int J Lab Hematol. 2012;34(suppl 1):1-180, PM52
    • (2012) Int J Lab Hematol. , vol.34 , Issue.SUPPL.1 , pp. 1-180
    • Rosenthal, N.1    Connell, B.2    Brown, B.3
  • 7
    • 0006407670 scopus 로고
    • Lack of reproducibility of band neutrophil identification despite the use of uniform identification criteria
    • Cornbleet PJ, Novak R. Lack of reproducibility of band neutrophil identification despite the use of uniform identification criteria. Lab Hematol. 1995;1:89-96
    • (1995) Lab Hematol. , vol.1 , pp. 89-96
    • Cornbleet, P.J.1    Novak, R.2
  • 9
    • 0141616498 scopus 로고    scopus 로고
    • Evaluation of immature granulocytes counts by the XE-IG master: Upgraded software for the XE-2100 automated hematology analyser
    • Briggs C, Kunka S, Fujimoto H, et al. Evaluation of immature granulocytes counts by the XE-IG Master: upgraded software for the XE-2100 automated hematology analyser. Lab Hematol. 2003;9:117-124
    • (2003) Lab Hematol. , vol.9 , pp. 117-124
    • Briggs, C.1    Kunka, S.2    Fujimoto, H.3
  • 10
    • 79960974715 scopus 로고    scopus 로고
    • Improved flagging rates on the sysmex XE-5000 compared with the XE-2100 reduce the number of manual film reviews and increase laboratory productivity
    • Briggs C, Linssen J, Longair I, et al. Improved flagging rates on the Sysmex XE-5000 compared with the XE-2100 reduce the number of manual film reviews and increase laboratory productivity. Am J Clin Pathol. 2011;136:309-316
    • (2011) Am J Clin Pathol. , vol.136 , pp. 309-316
    • Briggs, C.1    Linssen, J.2    Longair, I.3
  • 11
    • 79960282659 scopus 로고    scopus 로고
    • Granularity index of the SYSMEX XE-5000 hematology analyser as a replacement for manual microscopy of toxic granulation neutrophils in patients with inflammatory diseases
    • Zimmerman M, Cremer M, Hoffman C, et al. Granularity index of the SYSMEX XE-5000 hematology analyser as a replacement for manual microscopy of toxic granulation neutrophils in patients with inflammatory diseases. Clin Chem Lab Med. 2011;49:1193-1198
    • (2011) Clin Chem Lab Med. , vol.49 , pp. 1193-1198
    • Zimmerman, M.1    Cremer, M.2    Hoffman, C.3
  • 12
    • 78349241365 scopus 로고    scopus 로고
    • Routine diagnostic procedures of myelodysplastic syndromes: Value of a structural blood cell parameter (NEUT-X) determined by the Sysmex XE-2100
    • Le Roux G, Vlad A, Eclache V, et al. Routine diagnostic procedures of myelodysplastic syndromes: value of a structural blood cell parameter (NEUT-X) determined by the Sysmex XE-2100. Int J Lab Hematol. 2010;32:e237-e243
    • (2010) Int J Lab Hematol. , vol.32
    • Le Roux, G.1    Vlad, A.2    Eclache, V.3
  • 13
    • 77953562454 scopus 로고    scopus 로고
    • The utility of the Sysmex XE-2100 analyzer's NEUT-X and NEUT-Y parameters for detecting neutrophil dysplasia in myelodysplastic syndromes
    • Furundarena JR, Araiz M, Uranga M, et al. The utility of the Sysmex XE-2100 analyzer's NEUT-X and NEUT-Y parameters for detecting neutrophil dysplasia in myelodysplastic syndromes. Int J Lab Hematol. 2009;32:360-366
    • (2009) Int J Lab Hematol. , vol.32 , pp. 360-366
    • Furundarena, J.R.1    Araiz, M.2    Uranga, M.3
  • 14
    • 84888213009 scopus 로고    scopus 로고
    • Automated immature granulocyte counts on the new sysmex XN automated hematology analyzer
    • PM51
    • Rosenthal N, Connell B, Brown B, et al. Automated immature granulocyte counts on the new Sysmex XN Automated Hematology Analyzer. Int J Lab Hematol. 2012;34(suppl 1):1-180, PM51
    • (2012) Int J Lab Hematol. , vol.34 , Issue.SUPPL.1 , pp. 1-180
    • Rosenthal, N.1    Connell, B.2    Brown, B.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.