메뉴 건너뛰기




Volumn 136, Issue 2, 2011, Pages 309-316

Improved flagging rates on the sysmex XE-5000 compared with the XE-2100 reduce the number of manual film reviews and increase laboratory productivity

Author keywords

Efficiency; Flags; Microscopic review; Sysmex XE 5000

Indexed keywords

ADULT; ANALYTICAL ERROR; ARTICLE; AUTOANALYZER; BASOPHIL; BLOOD ANALYSIS; CELL FLAGGING; CELL LABELING; CELL STRUCTURE; EOSINOPHIL COUNT; FALSE NEGATIVE RESULT; FALSE POSITIVE RESULT; GRANULOCYTE; HUMAN; HUMAN CELL; LEUKOCYTE COUNT; LYMPHOBLAST; LYMPHOCYTE COUNT; MAJOR CLINICAL STUDY; MICROSCOPY; MONOCYTE; NEUTROPHIL COUNT; PRIORITY JOURNAL; SENSITIVITY AND SPECIFICITY;

EID: 79960974715     PISSN: 00029173     EISSN: 19437722     Source Type: Journal    
DOI: 10.1309/AJCPDLR4KGKAFW4W     Document Type: Article
Times cited : (37)

References (18)
  • 1
    • 0034452663 scopus 로고    scopus 로고
    • New quantitative parameters on a recently introduced automated blood cell counter - The XE 2100
    • DOI 10.1046/j.1365-2257.2000.00330.x
    • Briggs C, Harrison P, Grant D, et al. New quantitative parameters on a recently introduced automated blood cell counter: the XE-2100. Clin Lab Haematol. 2000;22:345-350. (Pubitemid 32324410)
    • (2000) Clinical and Laboratory Haematology , vol.22 , Issue.6 , pp. 345-350
    • Briggs, C.1    Harrison, P.2    Grant, D.3    Staves, J.4    Machin, S.J.5
  • 2
    • 0141616498 scopus 로고    scopus 로고
    • Evaluation of immature granulocyte counts by the XE-IG Master: Upgraded software for the XE-2100 automated hematology analyzer
    • Briggs C, Kunka S, Fujimoto H, et al. Evaluation of immature granulocyte counts by the XE-IG master: upgraded software for the XE-2100 automated hematology analyzer. Lab Hematol. 2003;9:117-124. (Pubitemid 37220790)
    • (2003) Laboratory Hematology , vol.9 , Issue.3 , pp. 117-124
    • Briggs, C.1    Kunka, S.2    Fujimoto, H.3    Hamaguchi, Y.4    Davis, B.H.5    Machin, S.J.6
  • 3
    • 3042759878 scopus 로고    scopus 로고
    • Assessment of an immature platelet fraction (IPF) in peripheral thrombocytopenia
    • DOI 10.1111/j.1365-2141.2004.04987.x
    • Briggs C, Hart D, Kunka S, et al. Assessment of an immature platelet fraction (IPF) in peripheral thrombocytopenia. Br J Haematol. 2004;126:93-99. (Pubitemid 38859488)
    • (2004) British Journal of Haematology , vol.126 , Issue.1 , pp. 93-99
    • Briggs, C.1    Kunka, S.2    Hart, D.3    Oguni, S.4    Machin, S.J.5
  • 4
    • 77954752944 scopus 로고    scopus 로고
    • Correlation between immature platelet fraction and reticulated platelets: Usefulness in the etiology diagnosis of thrombocytopenia
    • Pons I, Monteagudo M, Lucchetti G, et al. Correlation between immature platelet fraction and reticulated platelets: usefulness in the etiology diagnosis of thrombocytopenia. Eur J Haematol. 2010;85:158-163.
    • (2010) Eur J Haematol , vol.85 , pp. 158-163
    • Pons, I.1    Monteagudo, M.2    Lucchetti, G.3
  • 6
    • 0031961012 scopus 로고    scopus 로고
    • Use of reticulocyte cellular indices in the diagnosis and treatment of haematological disorders
    • Brugnara C. Use of reticulocyte cellular indices in the diagnosis and treatment of haematological disorders. Int J Clin Lab Res. 1998;28:1-11.
    • (1998) Int J Clin Lab Res , vol.28 , pp. 1-11
    • Brugnara, C.1
  • 7
    • 73349110102 scopus 로고    scopus 로고
    • Potential utility of the new Sysmex XE 5000 red blood cell extended parameters in the study of disorders of iron metabolism
    • Urrechaga E, Borque L, Escanero JF. Potential utility of the new Sysmex XE 5000 red blood cell extended parameters in the study of disorders of iron metabolism. Clin Chem Lab Med. 2009;47:411-416.
    • (2009) Clin Chem Lab Med , vol.47 , pp. 411-416
    • Urrechaga, E.1    Borque, L.2    Escanero, J.F.3
  • 10
    • 55149091790 scopus 로고    scopus 로고
    • Comparison of four hematology analyzers, CELL-DYN Sapphire, ADVIA 120, Coulter LH 750 and Sysmex XE-2100, in terms of clinical usefulness
    • Kang S, Kim HK, Ham CK, et al. Comparison of four hematology analyzers, CELL-DYN Sapphire, ADVIA 120, Coulter LH 750 and Sysmex XE-2100, in terms of clinical usefulness. Int J Lab Hematol. 2008;30:480-486.
    • (2008) Int J Lab Hematol , vol.30 , pp. 480-486
    • Kang, S.1    Kim, H.K.2    Ham, C.K.3
  • 11
  • 12
    • 79960999987 scopus 로고    scopus 로고
    • Identification of high fluorescence-stained lymphocytes (HFL) count on the XE-5000 with efficient multichannel messaging (eMM) as antibody synthesizing, c.q. plasma cells
    • Linssen J, Jennissen V. Identification of high fluorescence-stained lymphocytes (HFL) count on the XE-5000 with efficient multichannel messaging (eMM) as antibody synthesizing, c.q. plasma cells. Sysmex J Int. 2009;19:1-8.
    • (2009) Sysmex J Int , vol.19 , pp. 1-8
    • Linssen, J.1    Jennissen, V.2
  • 14
    • 0022397186 scopus 로고
    • A critical evaluation of the manual/visual differential leukocyte counting method
    • Koepke JA, Dotson MA, Shifmann MA. A critical evaluation of the manual/visual differential leukocyte counting method. Blood Cells. 1985;11:173-186. (Pubitemid 16136505)
    • (1985) Blood Cells , vol.11 , Issue.2 , pp. 173-186
    • Koepke, J.A.1    Dotson, M.A.2    Shifman, M.A.3
  • 15
    • 0022393168 scopus 로고
    • Statistical reflections on finding atypical cells
    • Rumke CL. Statistical reflections on finding atypical cells. Blood Cells. 1985;11:141-144. (Pubitemid 16178599)
    • (1985) Blood Cells , vol.11 , Issue.1 , pp. 141-144
    • Rumke, C.L.1
  • 16
    • 33646708700 scopus 로고    scopus 로고
    • Laboratory productivity and the rate of manual peripheral blood smear review: A College of American Pathologists Q-Probes study of 95 141 complete blood count determinations performed in 263 institutions
    • Novis DA, Walsh M, Wilkinson D, et al. Laboratory productivity and the rate of manual peripheral blood smear review: a College of American Pathologists Q-Probes study of 95,141 complete blood count determinations performed in 263 institutions. Arch Pathol Lab Med. 2006;130:596-601. (Pubitemid 43736854)
    • (2006) Archives of Pathology and Laboratory Medicine , vol.130 , Issue.5 , pp. 596-601
    • Novis, D.A.1    Walsh, M.2    Wilkinson, D.3    St., L.M.4    Ben-Ezra, J.5
  • 17
    • 22144495751 scopus 로고    scopus 로고
    • The international consensus group for hematology review: Suggested criteria for action following automated CBC and WBC differential analysis
    • DOI 10.1532/LH96.05019
    • Barnes PW, McFadden SL, Machin SJ, et al. The International Consensus Group for Hematology Review: suggested criteria for action following automated CBC and WBC differential analysis. Lab Hematol. 2005;11:83-90. (Pubitemid 40975549)
    • (2005) Laboratory Hematology , vol.11 , Issue.2 , pp. 83-90
    • Barnes, P.W.1    McFadden, S.L.2    Machin, S.J.3    Simson, E.4
  • 18
    • 58449128069 scopus 로고    scopus 로고
    • Can automated blood film analysis replace the manual differential? An evaluation of the CellaVision DM96 automated image analysis system
    • Briggs C, Longair I, Slavik M, et al. Can automated blood film analysis replace the manual differential? an evaluation of the CellaVision DM96 automated image analysis system. Int J Lab Hematol. 2009;31:48-60.
    • (2009) Int J Lab Hematol , vol.31 , pp. 48-60
    • Briggs, C.1    Longair, I.2    Slavik, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.