메뉴 건너뛰기




Volumn 6, Issue 257, 2014, Pages

An osseointegrated human-machine gateway for long-term sensory feedback and motor control of artificial limbs

Author keywords

[No Author keywords available]

Indexed keywords

ARTICLE; CASE REPORT; EQUIPMENT DESIGN; HUMAN; LIMB MOVEMENT; LIMB PROSTHESIS; MAN MACHINE INTERACTION; MOTOR CONTROL; MYOELECTRIC CONTROL; NERVE STIMULATION; NEUROMUSCULAR SYSTEM; ORTHOPEDIC IMPLANT; OSSEOINTEGRATED HUMAN MACHINE GATEWAY; PATTERN RECOGNITION; SENSORY FEEDBACK; TACTILE FEEDBACK; BONE REGENERATION; DAILY LIFE ACTIVITY; DISABLED PERSON; ELECTRODE IMPLANT; ELECTROMYOGRAPHY; JOINT CHARACTERISTICS AND FUNCTIONS; PROSTHESIS DESIGN; REHABILITATION; TOUCH; TRANSLATIONAL RESEARCH;

EID: 84908368334     PISSN: 19466234     EISSN: 19466242     Source Type: Journal    
DOI: 10.1126/scitranslmed.3008933     Document Type: Article
Times cited : (380)

References (42)
  • 2
    • 0019291425 scopus 로고
    • Implantable electrical and mechanical interfaces with nerve and muscle
    • J. A. Hoffer, G. E. Loeb, Implantable electrical and mechanical interfaces with nerve and muscle. Ann. Biomed. Eng. 8, 351-360 (1980).
    • (1980) Ann. Biomed. Eng. , vol.8 , pp. 351-360
    • Hoffer, J.A.1    Loeb, G.E.2
  • 3
    • 3142743126 scopus 로고    scopus 로고
    • Residual function in peripheral nerve stumps of amputees: Implications for neural control of artificial limbs
    • G. S. Dhillon, S. M. Lawrence, D. T. Hutchinson, K. W. Horch, Residual function in peripheral nerve stumps of amputees: Implications for neural control of artificial limbs. J. Hand. Surg. Am. 29, 605-615 (2004).
    • (2004) J. Hand. Surg. Am. , vol.29 , pp. 605-615
    • Dhillon, G.S.1    Lawrence, S.M.2    Hutchinson, D.T.3    Horch, K.W.4
  • 4
    • 84871401377 scopus 로고    scopus 로고
    • Interfacing the somatosensory system to restore touch and proprioception: Essential considerations
    • D. J. Weber, R. Friesen, L. E. Miller, Interfacing the somatosensory system to restore touch and proprioception: Essential considerations. J. Mot. Behav. 44, 403-418 (2012).
    • (2012) J. Mot. Behav. , vol.44 , pp. 403-418
    • Weber, D.J.1    Friesen, R.2    Miller, L.E.3
  • 8
    • 84856019167 scopus 로고    scopus 로고
    • Assessment of more than 1,000 implanted percutaneous bone conduction devices: Skin reactions and implant survival
    • C. A. Dun, H. T. Faber, M. J. de Wolf, E. A. Mylanus, C. W. Cremers, M. K. Hol, Assessment of more than 1,000 implanted percutaneous bone conduction devices: Skin reactions and implant survival. Otol. Neurotol. 33, 192-198 (2012).
    • (2012) Otol. Neurotol. , vol.33 , pp. 192-198
    • Dun, C.A.1    Faber, H.T.2    De Wolf, M.J.3    Mylanus, E.A.4    Cremers, C.W.5    Hol, M.K.6
  • 9
    • 70349291362 scopus 로고    scopus 로고
    • One hundred patients treated with osseointegrated transfemoral amputation prostheses - Rehabilitation perspective
    • K. Hagberg, R. Bra˚nemark, One hundred patients treated with osseointegrated transfemoral amputation prostheses - Rehabilitation perspective. J. Rehabil. Res. Dev. 46, 331-344 (2009).
    • (2009) J. Rehabil. Res. Dev. , vol.46 , pp. 331-344
    • Hagberg, K.1    Bra˚nemark, R.2
  • 10
    • 84898493377 scopus 로고    scopus 로고
    • A novel osseointegrated, percutaneous prosthetic system for treatment of patients with transfemoral amputation: A prospective study of 51 patients
    • R. Bra˚nemark, Ö. Berlin, K. Hagberg, P. Bergh, B. Gunterberg, B. Rydevik, A novel osseointegrated, percutaneous prosthetic system for treatment of patients with transfemoral amputation: A prospective study of 51 patients. Bone Joint J. 96-B, 106-113 (2014).
    • (2014) Bone Joint J , vol.96 B , pp. 106-113
    • Bra˚nemark, R.1    Berlin, O.2    Hagberg, K.3    Bergh, P.4    Gunterberg, B.5    Rydevik, B.6
  • 11
    • 0141887046 scopus 로고    scopus 로고
    • Rehabilitation of the trans-femoral amputee with an osseointegrated prosthesis: The United Kingdom experience
    • J. Sullivan, M. Uden, K. P. Robinson, S. Sooriakumaran, Rehabilitation of the trans-femoral amputee with an osseointegrated prosthesis: The United Kingdom experience. Prosthet. Orthot. Int. 27, 114-120 (2003).
    • (2003) Prosthet. Orthot. Int. , vol.27 , pp. 114-120
    • Sullivan, J.1    Uden, M.2    Robinson, K.P.3    Sooriakumaran, S.4
  • 12
    • 40749104687 scopus 로고    scopus 로고
    • Osseointegrated trans-femoral amputation prostheses: Prospective results of general and condition-specific quality of life in 18 patients at 2-year follow-up
    • K. Hagberg, R. Bra˚nemark, B. Gunterberg, B. Rydevik, Osseointegrated trans-femoral amputation prostheses: Prospective results of general and condition-specific quality of life in 18 patients at 2-year follow-up. Prosthet. Orthot. Int. 32, 29-41 (2008).
    • (2008) Prosthet. Orthot. Int. , vol.32 , pp. 29-41
    • Hagberg, K.1    Bra˚nemark, R.2    Gunterberg, B.3    Rydevik, B.4
  • 13
    • 82255180640 scopus 로고    scopus 로고
    • My prosthesis as a part of me: A qualitative analysis of living with an osseointegrated prosthetic limb
    • M. Lundberg, K. Hagberg, J. Bullington, My prosthesis as a part of me: A qualitative analysis of living with an osseointegrated prosthetic limb. Prosthet. Orthot. Int. 35, 207-214 (2011).
    • (2011) Prosthet. Orthot. Int. , vol.35 , pp. 207-214
    • Lundberg, M.1    Hagberg, K.2    Bullington, J.3
  • 16
    • 84862333807 scopus 로고    scopus 로고
    • On the viability of implantable electrodes for the natural control of artificial limbs: Review and discussion
    • M. Ortiz-Catalan, R. Bra˚nemark, B. Ha˚kansson, J. Delbeke, On the viability of implantable electrodes for the natural control of artificial limbs: Review and discussion. Biomed. Eng. Online 11, 33 (2012).
    • (2012) Biomed. Eng. Online , vol.11 , pp. 33
    • Ortiz-Catalan, M.1    Bra˚nemark, R.2    Ha˚kansson, B.3    Delbeke, J.4
  • 17
    • 0038180934 scopus 로고    scopus 로고
    • The effect of subcutaneous fat on myoelectric signal amplitude and cross-talk
    • T. Kuiken, M. M. Lowery, N. S. Stoykov, The effect of subcutaneous fat on myoelectric signal amplitude and cross-talk. Prosthet. Orthot. Int. 27, 48-54 (2003).
    • (2003) Prosthet. Orthot. Int. , vol.27 , pp. 48-54
    • Kuiken, T.1    Lowery, M.M.2    Stoykov, N.S.3
  • 18
    • 0033366456 scopus 로고    scopus 로고
    • Does use of a myoelectric prosthesis prevent cortical reorganization and phantom limb pain?
    • M. Lotze, W. Grodd, N. Birbaumer, M. Erb, E. Huse, H. Flor, Does use of a myoelectric prosthesis prevent cortical reorganization and phantom limb pain? Nat. Neurosci. 2, 501-502 (1999).
    • (1999) Nat. Neurosci. , vol.2 , pp. 501-502
    • Lotze, M.1    Grodd, W.2    Birbaumer, N.3    Erb, M.4    Huse, E.5    Flor, H.6
  • 19
    • 84898040970 scopus 로고    scopus 로고
    • Treatment of phantom limb pain (PLP) based on augmented reality and gaming controlled by myoelectric pattern recognition: A case study of a chronic PLP
    • M. Ortiz-Catalan, N. Sander, M. B. Kristoffersen, B. Ha˚kansson, R. Bra˚nemark, Treatment of phantom limb pain (PLP) based on augmented reality and gaming controlled by myoelectric pattern recognition: A case study of a chronic PLP. Front. Neurosci. 8, 24 (2014).
    • (2014) Front. Neurosci. , vol.8 , pp. 24
    • Ortiz-Catalan, M.1    Sander, N.2    Kristoffersen, M.B.3    Ha˚kansson, B.4    Bra˚nemark, R.5
  • 20
    • 79960833400 scopus 로고    scopus 로고
    • Target Achievement Control Test: Evaluating real-time myoelectric pattern-recognition control of multifunctional upper-limb prostheses
    • A. M. Simon, L. J. Hargrove, B. A. Lock, T. A. Kuiken, Target Achievement Control Test: Evaluating real-time myoelectric pattern-recognition control of multifunctional upper-limb prostheses. J. Rehabil. Res. Dev. 48, 619-627 (2011).
    • (2011) J. Rehabil. Res. Dev. , vol.48 , pp. 619-627
    • Simon, A.M.1    Hargrove, L.J.2    Lock, B.A.3    Kuiken, T.A.4
  • 21
  • 22
    • 29644439037 scopus 로고    scopus 로고
    • Direct neural sensory feedback and control of a prosthetic arm
    • G. S. Dhillon, K. W. Horch, Direct neural sensory feedback and control of a prosthetic arm. IEEE Trans. Neural Syst. Rehabil. Eng. 13, 468-472 (2005).
    • (2005) IEEE Trans. Neural Syst. Rehabil. Eng. , vol.13 , pp. 468-472
    • Dhillon, G.S.1    Horch, K.W.2
  • 23
    • 80054062765 scopus 로고    scopus 로고
    • Object discrimination with an artificial hand using electrical stimulation of peripheral tactile and proprioceptive pathways with intrafascicular electrodes
    • K. Horch, S. Meek, T. G. Taylor, D. T. Hutchinson, Object discrimination with an artificial hand using electrical stimulation of peripheral tactile and proprioceptive pathways with intrafascicular electrodes. IEEE Trans. Neural Syst. Rehabil. Eng. 19, 483-489 (2011).
    • (2011) IEEE Trans. Neural Syst. Rehabil. Eng. , vol.19 , pp. 483-489
    • Horch, K.1    Meek, S.2    Taylor, T.G.3    Hutchinson, D.T.4
  • 25
    • 0016100050 scopus 로고
    • A sensory feedback system for an upper-limb amputation prosthesis
    • F. W. Clippinger, R. Avery, B. Titus, A sensory feedback system for an upper-limb amputation prosthesis. Bull. Prosthet. Res. Fall, 247-258 (1974).
    • (1974) Bull. Prosthet. Res. , vol.FALL , pp. 247-258
    • Clippinger, F.W.1    Avery, R.2    Titus, B.3
  • 27
    • 0020644137 scopus 로고
    • Sensations evoked by intraneural microstimulation of single mechanoreceptor units innervating the human hand
    • J. Ochoa, E. Torebjörk, Sensations evoked by intraneural microstimulation of single mechanoreceptor units innervating the human hand. J. Physiol. 342, 633-654 (1983).
    • (1983) J. Physiol. , vol.342 , pp. 633-654
    • Ochoa, J.1    Torebjörk, E.2
  • 28
    • 0018248287 scopus 로고
    • Clinical application study of multifunctional prosthetic hands
    • P. Herberts, C. Almström, K. Caine, Clinical application study of multifunctional prosthetic hands. J. Bone Joint Surg. Br. 60-B, 552-560 (1978).
    • (1978) J. Bone Joint Surg. Br. , vol.60 B , pp. 552-560
    • Herberts, P.1    Almström, C.2    Caine, K.3
  • 29
    • 0018196642 scopus 로고
    • Pattern-recognition arm prosthesis: A historical perspective - A final report
    • R. W. Wirta, D. R. Taylor, F. R. Finley, Pattern-recognition arm prosthesis: A historical perspective - A final report. Bull. Prosthet. Res. Fall, 8-35 (1978).
    • (1978) Bull. Prosthet. Res. , vol.FALL , pp. 8-35
    • Wirta, R.W.1    Taylor, D.R.2    Finley, F.R.3
  • 30
    • 0035988865 scopus 로고    scopus 로고
    • Three-layer volume conductor model and software package for applications in surface electromyography
    • J. H. Blok, D. F. Stegeman, A. van Oosterom, Three-layer volume conductor model and software package for applications in surface electromyography. Ann. Biomed. Eng. 30, 566-577 (2002).
    • (2002) Ann. Biomed. Eng. , vol.30 , pp. 566-577
    • Blok, J.H.1    Stegeman, D.F.2    Van Oosterom, A.3
  • 31
    • 60249084509 scopus 로고    scopus 로고
    • Targeted muscle reinnervation for real-time myoelectric control of multifunction artificial arms
    • T. A. Kuiken, G. Li, B. A. Lock, R. D. Lipschutz, L. A. Miller, K. A. Stubblefield, K. B. Englehart, Targeted muscle reinnervation for real-time myoelectric control of multifunction artificial arms. JAMA 301, 619-628 (2009).
    • (2009) JAMA , vol.301 , pp. 619-628
    • Kuiken, T.A.1    Li, G.2    Lock, B.A.3    Lipschutz, R.D.4    Miller, L.A.5    Stubblefield, K.A.6    Englehart, K.B.7
  • 33
    • 27744494889 scopus 로고    scopus 로고
    • Myelination: An overlooked mechanism of synaptic plasticity?
    • R. D. Fields, Myelination: An overlooked mechanism of synaptic plasticity? Neuroscientist 11, 528-531 (2005).
    • (2005) Neuroscientist , vol.11 , pp. 528-531
    • Fields, R.D.1
  • 34
    • 84876198866 scopus 로고    scopus 로고
    • BioPatRec: A modular research platform for the control of artificial limbs based on pattern recognition algorithms
    • M. Ortiz-Catalan, R. Bra˚nemark, B. Ha˚kansson, BioPatRec: A modular research platform for the control of artificial limbs based on pattern recognition algorithms. Source Code Biol. Med. 8, 11 (2013).
    • (2013) Source Code Biol. Med. , vol.8 , pp. 11
    • Ortiz-Catalan, M.1    Bra˚nemark, R.2    Ha˚kansson, B.3
  • 35
    • 82255180641 scopus 로고    scopus 로고
    • Osseointegration amputation prostheses on the upper limbs: Methods, prosthetics and rehabilitation
    • S. Jönsson, K. Caine-Winterberger, R. Bra˚nemark, Osseointegration amputation prostheses on the upper limbs: Methods, prosthetics and rehabilitation. Prosthet. Orthot. Int. 35, 190-200 (2011).
    • (2011) Prosthet. Orthot. Int. , vol.35 , pp. 190-200
    • Jönsson, S.1    Caine-Winterberger, K.2    Bra˚nemark, R.3
  • 37
    • 27644591279 scopus 로고    scopus 로고
    • A critical review of interfaces with the peripheral nervous system for the control of neuroprostheses and hybrid bionic systems
    • X. Navarro, T. B. Krueger, N. Lago, S. Micera, T. Stieglitz, P. Dario, A critical review of interfaces with the peripheral nervous system for the control of neuroprostheses and hybrid bionic systems. J. Peripher. Nerv. Syst. 10, 229-258 (2005).
    • (2005) J. Peripher. Nerv. Syst. , vol.10 , pp. 229-258
    • Navarro, X.1    Krueger, T.B.2    Lago, N.3    Micera, S.4    Stieglitz, T.5    Dario, P.6
  • 38
    • 80052732296 scopus 로고    scopus 로고
    • Electrodes and chronic optic nerve stimulation
    • J. Delbeke, Electrodes and chronic optic nerve stimulation. Biocybern. Biomed. Eng. 31, 81-94 (2011).
    • (2011) Biocybern. Biomed. Eng. , vol.31 , pp. 81-94
    • Delbeke, J.1
  • 39
    • 70449510356 scopus 로고    scopus 로고
    • Stimulation stability and selectivity of chronically implanted multicontact nerve cuff electrodes in the human upper extremity
    • K. H. Polasek, H. A. Hoyen, M. W. Keith, R. F. Kirsch, D. J. Tyler, Stimulation stability and selectivity of chronically implanted multicontact nerve cuff electrodes in the human upper extremity. IEEE Trans. Neural. Syst. Rehabil. Eng. 17, 428-437 (2009).
    • (2009) IEEE Trans. Neural. Syst. Rehabil. Eng. , vol.17 , pp. 428-437
    • Polasek, K.H.1    Hoyen, H.A.2    Keith, M.W.3    Kirsch, R.F.4    Tyler, D.J.5
  • 40
    • 84874012434 scopus 로고    scopus 로고
    • Effect on signal-to-noise ratio of splitting the continuous contacts of cuff electrodes into smaller recording areas
    • M. Ortiz-Catalan, J. Marin-Millan, J. Delbeke, B. Ha˚kansson, R. Bra˚nemark, Effect on signal-to-noise ratio of splitting the continuous contacts of cuff electrodes into smaller recording areas. J. Neuroeng. Rehabil. 10, 22 (2013).
    • (2013) J. Neuroeng. Rehabil. , vol.10 , pp. 22
    • Ortiz-Catalan, M.1    Marin-Millan, J.2    Delbeke, J.3    Ha˚kansson, B.4    Bra˚nemark, R.5
  • 41
    • 84878662556 scopus 로고    scopus 로고
    • accessed January 2014
    • M. Ortiz-Catalan, BioPatRec, http://code.google.com/p/biopatrec [accessed January 2014].
    • BioPatRec
    • Ortiz-Catalan, M.1
  • 42
    • 65649123814 scopus 로고    scopus 로고
    • A distributed architecture for activating the peripheral nervous system
    • D. Andreu, D. Guiraud, G. Souquet, A distributed architecture for activating the peripheral nervous system. J. Neural. Eng. 6, 026001 (2009).
    • (2009) J. Neural. Eng. , vol.6 , pp. 026001
    • Andreu, D.1    Guiraud, D.2    Souquet, G.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.