메뉴 건너뛰기




Volumn 9, Issue 10, 2014, Pages

Monte Carlo study of radiation dose enhancement by gadolinium in megavoltage and high dose rate radiotherapy

Author keywords

[No Author keywords available]

Indexed keywords

GADOLINIUM; CONTRAST MEDIUM; GADOLINIUM TEXAPHYRIN; METALLOPORPHYRIN; RADIOSENSITIZING AGENT;

EID: 84907546565     PISSN: None     EISSN: 19326203     Source Type: Journal    
DOI: 10.1371/journal.pone.0109389     Document Type: Article
Times cited : (27)

References (29)
  • 1
    • 33846160552 scopus 로고    scopus 로고
    • Multifunctional polymeric micelles as cancer-targeted, MRI-ultrasensitive drug delivery systems
    • Nasongkla N, Bey E, Ren J., Ai H, Khemtong C, et al (2006) Multifunctional polymeric micelles as cancer-targeted, MRI-ultrasensitive drug delivery systems. Nano Letters 6: 2427-2430.
    • (2006) Nano Letters , vol.6 , pp. 2427-2430
    • Nasongkla, N.1    Bey, E.2    Ren, J.3    Ai, H.4    Khemtong, C.5
  • 2
    • 78651279520 scopus 로고    scopus 로고
    • Polymeric micelles in anticancer therapy: Targeting, imaging and triggered release
    • Oerlemans C, Bult W, Bos M., Storm G, Nijsen JF, et al (2010) Polymeric micelles in anticancer therapy: targeting, imaging and triggered release. Pharmaceutical Research 27: 2569-2589.
    • (2010) Pharmaceutical Research , vol.27 , pp. 2569-2589
    • Oerlemans, C.1    Bult, W.2    Bos, M.3    Storm, G.4    Nijsen, J.F.5
  • 4
    • 8344244538 scopus 로고    scopus 로고
    • Motexafin gadolinium: A redox-active tumor selective agent for the treatment of cancer
    • Evens AM (2004) Motexafin gadolinium: a redox-active tumor selective agent for the treatment of cancer. Current Opinion in Oncology 16: 576-580.
    • (2004) Current Opinion in Oncology , vol.16 , pp. 576-580
    • Evens, A.M.1
  • 5
    • 33744956073 scopus 로고    scopus 로고
    • Motexafin gadolinium, a tumor-selective drug targeting thioredoxin reductase and ribonucleotide reductase
    • Hashemy SI, Ungerstedt JS, Avval F.Z., Holmgren A. (2006) Motexafin Gadolinium, a Tumor-selective Drug Targeting Thioredoxin Reductase and Ribonucleotide Reductase. Journal of Biological Chemistry 281: 10691-10697.
    • (2006) Journal of Biological Chemistry , vol.281 , pp. 10691-10697
    • Hashemy, S.I.1    Ungerstedt, J.S.2    Avval, F.Z.3    Holmgren, A.4
  • 7
    • 79957655142 scopus 로고    scopus 로고
    • Ascorbate and endocytosed motexafin gadolinium induce lysosomal rupture
    • Berndt C, Kurz T, Bannenberg S., Jacob R, Holmgren A, et al (2011) Ascorbate and endocytosed Motexafin gadolinium induce lysosomal rupture. Cancer Letters 307: 119-123.
    • (2011) Cancer Letters , vol.307 , pp. 119-123
    • Berndt, C.1    Kurz, T.2    Bannenberg, S.3    Jacob, R.4    Holmgren, A.5
  • 9
    • 0035300617 scopus 로고    scopus 로고
    • Multicenter phase ib/II trial of the radiation enhancer motexafin gadolinium in patients with brain metastases
    • Carde P, Timmerman R, Mehta M.P., Koprowski CD, Ford J, et al. (2001) Multicenter Phase Ib/II trial of the radiation enhancer motexafin gadolinium in patients with brain metastases. Journal of Clinical Oncology 19: 2074-2083.
    • (2001) Journal of Clinical Oncology , vol.19 , pp. 2074-2083
    • Carde, P.1    Timmerman, R.2    Mehta, M.P.3    Koprowski, C.D.4    Ford, J.5
  • 10
    • 84877000537 scopus 로고    scopus 로고
    • Selective targeting of brain tumors with gold nanoparticle-induced radiosensitization
    • Joh DY, Sun L, Stangl M., Al Zaki A, Murty S, et al (2013) Selective Targeting of Brain Tumors with Gold Nanoparticle-Induced Radiosensitization. PLoS ONE 8: e62425.
    • (2013) PLoS ONE , vol.8 , pp. e62425
    • Joh, D.Y.1    Sun, L.2    Stangl, M.3    Al Zaki, A.4    Murty, S.5
  • 11
    • 4644321604 scopus 로고    scopus 로고
    • The use of gold nanoparticles to enhance radiotherapy in mice
    • Hainfeld JF, Slatkin DN, Smilowitz H.M. (2004) The use of gold nanoparticles to enhance radiotherapy in mice. Phys Med Biol 49: N309.
    • (2004) Phys Med Biol , vol.49 , pp. N309
    • Hainfeld, J.F.1    Slatkin, D.N.2    Smilowitz, H.M.3
  • 12
    • 68149100844 scopus 로고    scopus 로고
    • Gadolinium dose enhancement studies in microbeam radiation therapy
    • Prezado Y, Fois G, Le Duc G, Bravin A. (2009) Gadolinium dose enhancement studies in microbeam radiation therapy. Med Phys 36: 3568-3574.
    • (2009) Med Phys , vol.36 , pp. 3568-3574
    • Prezado, Y.1    Fois, G.2    Le Duc, G.3    Bravin, A.4
  • 14
    • 79961128562 scopus 로고    scopus 로고
    • Localized dose enhancement to tumor blood vessel endothelial cells via megavoltage X-rays and targeted gold nanoparticles: New potential for external beam radiotherapy
    • Berbeco RI, Ngwa W, Makrigiorgos G.M. (2011) Localized dose enhancement to tumor blood vessel endothelial cells via megavoltage X-rays and targeted gold nanoparticles: new potential for external beam radiotherapy. Int J Radiat Oncol Biol Phys 81: 270-276.
    • (2011) Int J Radiat Oncol Biol Phys , vol.81 , pp. 270-276
    • Berbeco, R.I.1    Ngwa, W.2    Makrigiorgos, G.M.3
  • 15
    • 22544458178 scopus 로고    scopus 로고
    • Estimation of tumour dose enhancement due to gold nanoparticles during typical radiation treatments: A preliminary Monte Carlo study
    • Cho SH (2005) Estimation of tumour dose enhancement due to gold nanoparticles during typical radiation treatments: a preliminary Monte Carlo study. Phys Med Biol 50: N163-N173.
    • (2005) Phys Med Biol , vol.50 , pp. N163-N173
    • Cho, S.H.1
  • 16
    • 77954735630 scopus 로고    scopus 로고
    • Estimation of microscopic dose enhancement factor around gold nanoparticles by Monte Carlo calculations
    • Jones BL, Krishnan S, Cho S.H. (2010) Estimation of microscopic dose enhancement factor around gold nanoparticles by Monte Carlo calculations. Med Phys 37: 3809-3816.
    • (2010) Med Phys , vol.37 , pp. 3809-3816
    • Jones, B.L.1    Krishnan, S.2    Cho, S.H.3
  • 18
    • 79551667662 scopus 로고    scopus 로고
    • Irradiation of gold nanoparticles by x-rays: Monte Carlo simulation of dose enhancements and the spatial properties of the secondary electrons production
    • Leung MKK, Chow JCL, Chithrani BD, Lee MJG, Oms B, et al (2011) Irradiation of gold nanoparticles by x-rays: Monte Carlo simulation of dose enhancements and the spatial properties of the secondary electrons production. Med Phys 38: 624-631.
    • (2011) Med Phys , vol.38 , pp. 624-631
    • Leung, M.K.K.1    Chow, J.C.L.2    Chithrani, B.D.3    Lee, M.J.G.4    Oms, B.5
  • 19
    • 56749184152 scopus 로고    scopus 로고
    • In vivo quantification of contrast agent concentration using the induced magnetic field for time-resolved arterial input function measurement with MRI
    • de Rochefort L., Nguyen T, Brown R., Spincemaille P, Choi G, et al (2008) In vivo quantification of contrast agent concentration using the induced magnetic field for time-resolved arterial input function measurement with MRI. Med Phys 35: 5328-5339.
    • (2008) Med Phys , vol.35 , pp. 5328-5339
    • De Rochefort, L.1    Nguyen, T.2    Brown, R.3    Spincemaille, P.4    Choi, G.5
  • 20
    • 78650054821 scopus 로고    scopus 로고
    • A Monte Carlo study of a flattening filter-free linear accelerator verified with measurements
    • Dalaryd M, Kragl G, Ceberg C., Georg D, McClean B, et al (2010) A Monte Carlo study of a flattening filter-free linear accelerator verified with measurements. Phys Med Biol 55: 7333-7344.
    • (2010) Phys Med Biol , vol.55 , pp. 7333-7344
    • Dalaryd, M.1    Kragl, G.2    Ceberg, C.3    Georg, D.4    McClean, B.5
  • 21
    • 84899485644 scopus 로고    scopus 로고
    • Monte Carlo comparison of superficial dose between flattening filter free and flattened beams
    • Javedan K, Feygelman V, Zhang R.R., Moros EG, Correa CR, et al. (2014) Monte Carlo comparison of superficial dose between flattening filter free and flattened beams. Physica medica 30: 503-508.
    • (2014) Physica Medica , vol.30 , pp. 503-508
    • Javedan, K.1    Feygelman, V.2    Zhang, R.R.3    Moros, E.G.4    Correa, C.R.5
  • 22
    • 84873551546 scopus 로고    scopus 로고
    • Is wax equivalent to tissue in electron conformal therapy planning? A Monte Carlo study of material approximation introduced dose difference
    • Zhang RR, Feygelman V, Harris E.R., Rao N., Moros EG, et al. (2013) Is wax equivalent to tissue in electron conformal therapy planning? A Monte Carlo study of material approximation introduced dose difference. J Appl Clin Med Phys 14: 92-101.
    • (2013) J Appl Clin Med Phys , vol.14 , pp. 92-101
    • Zhang, R.R.1    Feygelman, V.2    Harris, E.R.3    Rao, N.4    Moros, E.G.5
  • 23
    • 84866019566 scopus 로고    scopus 로고
    • A study on the dose distributions in various materials from an ir-192 HDR brachytherapy source
    • Hsu S-M, Wu C-H, Lee J-H, Hsieh Y-J, Yu C-Y, et al. (2012) A Study on the Dose Distributions in Various Materials from an Ir-192 HDR Brachytherapy Source. PLoS ONE 7: e44528.
    • (2012) PLoS ONE , vol.7 , pp. e44528
    • Hsu, S.-M.1    Wu, C.-H.2    Lee, J.-H.3    Hsieh, Y.-J.4    Yu, C.-Y.5
  • 24
    • 0029035150 scopus 로고
    • BEAM: A Monte Carlo code to simulate radiotherapy treatment units
    • Rogers DWO, Faddegon BA, Ding G.X., Ma C-M, We J, et al (1995) BEAM: A Monte Carlo code to simulate radiotherapy treatment units. Med Phys 22: 503-524.
    • (1995) Med Phys , vol.22 , pp. 503-524
    • Rogers, D.W.O.1    Faddegon, B.A.2    Ding, G.X.3    Ma, C.-M.4    We, J.5
  • 25
    • 0034104708 scopus 로고    scopus 로고
    • Accurate condensed history Monte Carlo simulation of electron transport. I. EGSnrc, the new EGS4 version
    • Kawrakow I (2000) Accurate condensed history Monte Carlo simulation of electron transport. I. EGSnrc, the new EGS4 version. Med Phys 27: 485-498.
    • (2000) Med Phys , vol.27 , pp. 485-498
    • Kawrakow, I.1
  • 26
    • 33746608072 scopus 로고    scopus 로고
    • Efficient photon beam dose calculations using DOSXYZnrc with BEAMnrc
    • Kawrakow I, Walters BRB (2006) Efficient photon beam dose calculations using DOSXYZnrc with BEAMnrc. Med Phys 33: 3046-3056.
    • (2006) Med Phys , vol.33 , pp. 3046-3056
    • Kawrakow, I.1    Walters, B.R.B.2
  • 27
    • 79960280336 scopus 로고    scopus 로고
    • Modeling the TrueBeam linac using a CAD to geant4 geometry implementation: Dose and IAEA-compliant phase space calculations
    • Constantin M, Perl J, LoSasso T., Keall P.J. (2011) Modeling the TrueBeam linac using a CAD to Geant4 geometry implementation: Dose and IAEA-compliant phase space calculations. Med Phys 38: 4018-4024.
    • (2011) Med Phys , vol.38 , pp. 4018-4024
    • Constantin, M.1    Perl, J.2    LoSasso, T.3    Keall, P.J.4
  • 28
    • 0028919251 scopus 로고
    • Dosimetry of interstitial brachytherapy sources: Recommendations of the AAPM radiation therapy committee task group no
    • Nath R, Anderson LL, Luxton G, Weaver K.A., Williamson JF, et al. (1995) Dosimetry of interstitial brachytherapy sources: Recommendations of the AAPM Radiation Therapy Committee Task Group No. 43. Med Phys 22: 209-234.
    • (1995) Med Phys , vol.22 , Issue.43 , pp. 209-234
    • Nath, R.1    Anderson, L.L.2    Luxton, G.3    Weaver, K.A.4    Williamson, J.F.5
  • 29
    • 79959362604 scopus 로고    scopus 로고
    • Dose reduction study in vaginal balloon packing filled with contrast for HDR brachytherapy treatment
    • Saini AS, Zhang GG, Finkelstein S.E., Biagioli M.C. (2011) Dose reduction study in vaginal balloon packing filled with contrast for HDR brachytherapy treatment. Int J Radiat Oncol Biol Phys 80: 1263-1267.
    • (2011) Int J Radiat Oncol Biol Phys , vol.80 , pp. 1263-1267
    • Saini, A.S.1    Zhang, G.G.2    Finkelstein, S.E.3    Biagioli, M.C.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.