메뉴 건너뛰기




Volumn 14, Issue 1, 2013, Pages 92-101

Is wax equivalent to tissue in electron conformal therapy planning? A Monte carlo study of material approximation introduced dose difference

Author keywords

Bolus; Electron conformal therapy; Monte Carlo; Stopping power ratio

Indexed keywords


EID: 84873551546     PISSN: None     EISSN: 15269914     Source Type: Journal    
DOI: 10.1120/jacmp.v14i1.3991     Document Type: Article
Times cited : (8)

References (19)
  • 1
    • 33745486017 scopus 로고    scopus 로고
    • Review of electron beam therapy physics
    • Hogstrom KR, Almond PR. Review of electron beam therapy physics. Phys Med Biol. 2006;51(13):R455-R489.
    • (2006) Phys Med Biol , vol.51 , Issue.13
    • Hogstrom, K.R.1    Almond, P.R.2
  • 8
    • 0034769006 scopus 로고    scopus 로고
    • Electron pencil-beam redefinition algorithm dose calculations in the presence of heterogeneities
    • Boyd RA, Hogstrom KR, Starkschall G. Electron pencil-beam redefinition algorithm dose calculations in the presence of heterogeneities. Med Phys. 2001;28(10):2096-104.
    • (2001) Med Phys , vol.28 , Issue.10 , pp. 2096-2104
    • Boyd, R.A.1    Hogstrom, K.R.2    Starkschall, G.3
  • 9
    • 0030937534 scopus 로고    scopus 로고
    • Electron beam dose calculations with the VMC algorithm and the verification data of the NCI working group
    • Fippel M, Kawrakow I, Friedrich K. Electron beam dose calculations with the VMC algorithm and the verification data of the NCI working group. Phys Med Biol. 1997;42(3):501-20.
    • (1997) Phys Med Biol , vol.42 , Issue.3 , pp. 501-520
    • Fippel, M.1    Kawrakow, I.2    Friedrich, K.3
  • 10
    • 40049095149 scopus 로고    scopus 로고
    • Experimental verification and clinical implementation of a commercial Monte Carlo electron beam dose calculation algorithm
    • Fragoso M, Pillai S, Solberg TD, Chatty LI. Experimental verification and clinical implementation of a commercial Monte Carlo electron beam dose calculation algorithm. Med Phys. 2008;35(3):1028-38.
    • (2008) Med Phys , vol.35 , Issue.3 , pp. 1028-1038
    • Fragoso, M.1    Pillai, S.2    Solberg, T.D.3    Chatty, L.I.4
  • 11
    • 16444385104 scopus 로고    scopus 로고
    • Sensitivity study for CT image use in Monte Carlo treatment planning
    • Verhaegen F and Devic S. Sensitivity study for CT image use in Monte Carlo treatment planning. Phys Med Biol. 2005;50(5):937-46.
    • (2005) Phys Med Biol , vol.50 , Issue.5 , pp. 937-946
    • Verhaegen, F.1    Devic, S.2
  • 12
    • 0023617766 scopus 로고
    • Average soft-tissue and bone models for use in radiation dosimetry
    • White DR, Woodard HQ, Hammond SM. Average soft-tissue and bone models for use in radiation dosimetry. Br J Radiol. 1987;60(717):907-13.
    • (1987) Br J Radiol , vol.60 , Issue.717 , pp. 907-913
    • White, D.R.1    Woodard, H.Q.2    Hammond, S.M.3
  • 13
    • 34047250299 scopus 로고    scopus 로고
    • Conversion of CT numbers into tissue parameters for Monte Carlo dose calculations
    • Vanderstraeten B, Chin PW, Fix M, et al. Conversion of CT numbers into tissue parameters for Monte Carlo dose calculations: a multi-centre study. Phys Med Biol. 2007;52(3):539-62.
    • (2007) a multi-centre study. Phys Med Biol , vol.52 , Issue.3 , pp. 539-562
    • Vanderstraeten, B.1    Chin, P.W.2    Fix, M.3
  • 14
    • 0034104708 scopus 로고    scopus 로고
    • Accurate condensed history Monte Carlo simulation of electron transport
    • Kawrakow I. Accurate condensed history Monte Carlo simulation of electron transport. I. EGSnrc, the new EGS4 version. Med Phys. 2000;27(3):485-98.
    • (2000) I. EGSnrc, the new EGS4 version. Med Phys. , vol.27 , Issue.3 , pp. 485-498
    • Kawrakow, I.1
  • 16
    • 33746608072 scopus 로고    scopus 로고
    • Efficient photon beam dose calculations using DOSXYZnrc with BEAMnrc
    • Kawrakow I and Walters BRB. Efficient photon beam dose calculations using DOSXYZnrc with BEAMnrc. Med Phys. 2006;33(6):3046-56.
    • (2006) Med Phys. , vol.33 , Issue.6 , pp. 3046-3056
    • Kawrakow, I.1    Walters, B.R.B.2
  • 17
    • 0025975407 scopus 로고
    • Clinical electron-beam dosimetry: report of AAPM Radiation Therapy Committee Task Group No
    • Khan FM, Doppke KP, Hogstrom KR, et al. Clinical electron-beam dosimetry: report of AAPM Radiation Therapy Committee Task Group No. 25. Med Phys. 1991;18(1):73-109.
    • (1991) 25. Med Phys. , vol.18 , Issue.1 , pp. 73-109
    • Khan, F.M.1    Doppke, K.P.2    Hogstrom, K.R.3
  • 18
    • 0029960079 scopus 로고    scopus 로고
    • Mean energy, energy-range relationships and depth-scaling factors for clinical electron beams
    • Ding GX and Rogers DW. Mean energy, energy-range relationships and depth-scaling factors for clinical electron beams. Med Phys. 1996;23(3):361-76.
    • (1996) Med Phys. , vol.23 , Issue.3 , pp. 361-376
    • Ding, G.X.1    Rogers, D.W.2
  • 19
    • 0031044381 scopus 로고    scopus 로고
    • Electron fluence correction factors for conversion of dose in plastic to dose in water
    • Ding GX, Rogers DW, Cygler JE, Mackie TR. Electron fluence correction factors for conversion of dose in plastic to dose in water. Med Phys. 1997;24(2):161-76.
    • (1997) Med Phys. , vol.24 , Issue.2 , pp. 161-176
    • Ding, G.X.1    Rogers, D.W.2    Cygler, J.E.3    Mackie, T.R.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.