-
1
-
-
79960446908
-
Clinical effectiveness of orthodontic miniscrew implants: a meta-analysis
-
Papadopoulos MA, Papageorgiou SN, Zogakis IP. Clinical effectiveness of orthodontic miniscrew implants: a meta-analysis. J Dent Res 2011, 90:969-976.
-
(2011)
J Dent Res
, vol.90
, pp. 969-976
-
-
Papadopoulos, M.A.1
Papageorgiou, S.N.2
Zogakis, I.P.3
-
2
-
-
0038622941
-
Optimum force magnitude for orthodontic tooth movement: a systematic literature review
-
Ren Y, Maltha JC, Kuijpers-Jagtman AM. Optimum force magnitude for orthodontic tooth movement: a systematic literature review. Angle Orthod 2003, 73:86-92.
-
(2003)
Angle Orthod
, vol.73
, pp. 86-92
-
-
Ren, Y.1
Maltha, J.C.2
Kuijpers-Jagtman, A.M.3
-
3
-
-
61649093840
-
Critical factors for the success of orthodontic mini-implants: a systematic review
-
Chen Y, Kyung HM, Zhao WT, Yu WJ. Critical factors for the success of orthodontic mini-implants: a systematic review. Am J Orthod Dentofac Orthop 2009, 135:284-291.
-
(2009)
Am J Orthod Dentofac Orthop
, vol.135
, pp. 284-291
-
-
Chen, Y.1
Kyung, H.M.2
Zhao, W.T.3
Yu, W.J.4
-
4
-
-
84868134626
-
Insertion torque and success of orthodontic mini-implants: a systematic review
-
Meursinge Reynders RA, Ronchi L, Ladu L, Etten-Jamaludin F, Bipat S. Insertion torque and success of orthodontic mini-implants: a systematic review. Am J Orthod Dentofac Orthop 2012, 142:596-614.
-
(2012)
Am J Orthod Dentofac Orthop
, vol.142
, pp. 596-614
-
-
Meursinge Reynders, R.A.1
Ronchi, L.2
Ladu, L.3
Etten-Jamaludin, F.4
Bipat, S.5
-
5
-
-
15244359466
-
Pull-out strength of monocortical screws placed in the maxillae and mandibles of dogs
-
Huja SS, Litsky AS, Beck FM, Johnson KA, Larsen PE. Pull-out strength of monocortical screws placed in the maxillae and mandibles of dogs. Am J Orthod Dentofac Orthop 2005, 127:307-313.
-
(2005)
Am J Orthod Dentofac Orthop
, vol.127
, pp. 307-313
-
-
Huja, S.S.1
Litsky, A.S.2
Beck, F.M.3
Johnson, K.A.4
Larsen, P.E.5
-
6
-
-
37449024672
-
Density of the alveolar and basal bones of the maxilla and the mandible
-
Park HS, Lee YJ, Jeong SH, Kwon TG. Density of the alveolar and basal bones of the maxilla and the mandible. Am J Orthod Dentofac Orthop 2008, 133:30-37.
-
(2008)
Am J Orthod Dentofac Orthop
, vol.133
, pp. 30-37
-
-
Park, H.S.1
Lee, Y.J.2
Jeong, S.H.3
Kwon, T.G.4
-
7
-
-
64749105981
-
Bone density at interradicular sites: implications for orthodontic mini-implant placement
-
Chun YS, Lim WH. Bone density at interradicular sites: implications for orthodontic mini-implant placement. Orthod Craniofac Res 2009, 12:25-32.
-
(2009)
Orthod Craniofac Res
, vol.12
, pp. 25-32
-
-
Chun, Y.S.1
Lim, W.H.2
-
8
-
-
84878481460
-
Assessment of potential orthodontic mini-implant insertion sites based on anatomical hard tissue parameters: a systematic review
-
Alsamak S, Gkantidis N, Bitsanis E, Christou P. Assessment of potential orthodontic mini-implant insertion sites based on anatomical hard tissue parameters: a systematic review. Int J Oral Maxillofac Implants 2012, 27:875-887.
-
(2012)
Int J Oral Maxillofac Implants
, vol.27
, pp. 875-887
-
-
Alsamak, S.1
Gkantidis, N.2
Bitsanis, E.3
Christou, P.4
-
9
-
-
70350029102
-
Comparison of cortical bone thickness and root proximity at maxillary and mandibular interradicular sites for orthodontic mini-implant placement
-
Lim JE, Lee SJ, Kim YJ, Lim WH, Chun YS. Comparison of cortical bone thickness and root proximity at maxillary and mandibular interradicular sites for orthodontic mini-implant placement. Orthod Craniofac Res 2009, 12:299-304.
-
(2009)
Orthod Craniofac Res
, vol.12
, pp. 299-304
-
-
Lim, J.E.1
Lee, S.J.2
Kim, Y.J.3
Lim, W.H.4
Chun, Y.S.5
-
10
-
-
35649012521
-
Effect of cortical bone thickness and implant placement torque on stability of orthodontic mini-implants
-
Motoyoshi M, Yoshida T, Ono A, Shimizu N. Effect of cortical bone thickness and implant placement torque on stability of orthodontic mini-implants. Int J Oral Maxillofac Implants 2007, 22:779-784.
-
(2007)
Int J Oral Maxillofac Implants
, vol.22
, pp. 779-784
-
-
Motoyoshi, M.1
Yoshida, T.2
Ono, A.3
Shimizu, N.4
-
11
-
-
0038722654
-
The removal torque of titanium screw inserted in rabbit tibia treated by dual acid etching
-
Cho SA, Park KT. The removal torque of titanium screw inserted in rabbit tibia treated by dual acid etching. Biomaterials 2003, 24:3611-3617.
-
(2003)
Biomaterials
, vol.24
, pp. 3611-3617
-
-
Cho, S.A.1
Park, K.T.2
-
12
-
-
77956325592
-
Anatomic variability in alveolar sites for skeletal anchorage
-
Martinelli FL, Luiz RR, Faria M, Nojima LI. Anatomic variability in alveolar sites for skeletal anchorage. Am J Orthod Dentofac Orthop 2010, 138:252-259.
-
(2010)
Am J Orthod Dentofac Orthop
, vol.138
, pp. 252-259
-
-
Martinelli, F.L.1
Luiz, R.R.2
Faria, M.3
Nojima, L.I.4
-
13
-
-
79953327103
-
Three-dimensional tomographic mapping related to primary stability and structural miniscrew characteristics
-
Silvestrini Biavati A, Tecco S, Migliorati M, Festa F, Marzo G, Gherlone E, Tete S. Three-dimensional tomographic mapping related to primary stability and structural miniscrew characteristics. Orthod Craniofac Res 2011, 14:88-99.
-
(2011)
Orthod Craniofac Res
, vol.14
, pp. 88-99
-
-
Silvestrini Biavati, A.1
Tecco, S.2
Migliorati, M.3
Festa, F.4
Marzo, G.5
Gherlone, E.6
Tete, S.7
-
14
-
-
84864488329
-
Cortical bone and ridge thickness of hyperdivergent and hypodivergent adults
-
Horner KA, Behrents RG, Kim KB, Buschang PH. Cortical bone and ridge thickness of hyperdivergent and hypodivergent adults. Am J Orthod Dentofac Orthop 2012, 142:170-178.
-
(2012)
Am J Orthod Dentofac Orthop
, vol.142
, pp. 170-178
-
-
Horner, K.A.1
Behrents, R.G.2
Kim, K.B.3
Buschang, P.H.4
-
15
-
-
79953315434
-
Cortical bone thickness at common miniscrew implant placement sites
-
Farnsworth D, Rossouw PE, Ceen RF, Buschang PH. Cortical bone thickness at common miniscrew implant placement sites. Am J Orthod Dentofac Orthop 2011, 139:495-503.
-
(2011)
Am J Orthod Dentofac Orthop
, vol.139
, pp. 495-503
-
-
Farnsworth, D.1
Rossouw, P.E.2
Ceen, R.F.3
Buschang, P.H.4
-
16
-
-
58149291870
-
The effect of cortical bone thickness on the stability of orthodontic mini-implants and on the stress distribution in surrounding bone
-
Motoyoshi M, Inaba M, Ono A, Ueno S, Shimizu N. The effect of cortical bone thickness on the stability of orthodontic mini-implants and on the stress distribution in surrounding bone. Int J Oral Maxillofac Surg 2009, 38:13-18.
-
(2009)
Int J Oral Maxillofac Surg
, vol.38
, pp. 13-18
-
-
Motoyoshi, M.1
Inaba, M.2
Ono, A.3
Ueno, S.4
Shimizu, N.5
-
17
-
-
0024725011
-
Hardness, an indicator of the mechanical competence of cancellous bone
-
Hodgskinson R, Currey JD, Evans GP. Hardness, an indicator of the mechanical competence of cancellous bone. J Orthop Res 1989, 7:754-758.
-
(1989)
J Orthop Res
, vol.7
, pp. 754-758
-
-
Hodgskinson, R.1
Currey, J.D.2
Evans, G.P.3
-
18
-
-
34249949418
-
Microindentation in bone: hardness variation with five independent variables
-
Johnson WM, Rapoff AJ. Microindentation in bone: hardness variation with five independent variables. J Mater Sci Mater Med 2007, 18:591-597.
-
(2007)
J Mater Sci Mater Med
, vol.18
, pp. 591-597
-
-
Johnson, W.M.1
Rapoff, A.J.2
-
19
-
-
49149128059
-
The role of mineralization and organic matrix in the microhardness of bone tissue from controls and osteoporotic patients
-
Boivin G, Bala Y, Doublier A, Farlay D, Ste-Marie LG, Meunier PJ, Delmas PD. The role of mineralization and organic matrix in the microhardness of bone tissue from controls and osteoporotic patients. Bone 2008, 43:532-538.
-
(2008)
Bone
, vol.43
, pp. 532-538
-
-
Boivin, G.1
Bala, Y.2
Doublier, A.3
Farlay, D.4
Ste-Marie, L.G.5
Meunier, P.J.6
Delmas, P.D.7
-
20
-
-
0037266356
-
Quality assessment of the cortical bone of the human mandible
-
Lettry S, Seedhom BB, Berry E, Cuppone M. Quality assessment of the cortical bone of the human mandible. Bone 2003, 32:35-44.
-
(2003)
Bone
, vol.32
, pp. 35-44
-
-
Lettry, S.1
Seedhom, B.B.2
Berry, E.3
Cuppone, M.4
-
21
-
-
84885045312
-
Effect of the quantity and quality of cortical bone on the failure force of a miniscrew implant
-
Iijima M, Takano M, Yasuda Y, Muguruma T, Nakagaki S, Sakakura Y, Ochi M, Mizoguchi I. Effect of the quantity and quality of cortical bone on the failure force of a miniscrew implant. Eur J Orthod 2013, 35:583-589.
-
(2013)
Eur J Orthod
, vol.35
, pp. 583-589
-
-
Iijima, M.1
Takano, M.2
Yasuda, Y.3
Muguruma, T.4
Nakagaki, S.5
Sakakura, Y.6
Ochi, M.7
Mizoguchi, I.8
-
22
-
-
84869854157
-
An in vitro study of factors affecting the primary stability of orthodontic mini-implants
-
Holm L, Cunningham SJ, Petrie A, Cousley RR. An in vitro study of factors affecting the primary stability of orthodontic mini-implants. Angle Orthod 2012, 82:1022-1028.
-
(2012)
Angle Orthod
, vol.82
, pp. 1022-1028
-
-
Holm, L.1
Cunningham, S.J.2
Petrie, A.3
Cousley, R.R.4
-
23
-
-
33744930120
-
Quantitative evaluation of cortical bone thickness with computed tomographic scanning for orthodontic implants
-
e7-721.e12
-
Deguchi T, Nasu M, Murakami K, Yabuuchi T, Kamioka H, Takano-Yamamoto T. Quantitative evaluation of cortical bone thickness with computed tomographic scanning for orthodontic implants. Am J Orthod Dentofac Orthop 2006, 129:721. e7-721.e12.
-
(2006)
Am J Orthod Dentofac Orthop
, vol.129
, pp. 721
-
-
Deguchi, T.1
Nasu, M.2
Murakami, K.3
Yabuuchi, T.4
Kamioka, H.5
Takano-Yamamoto, T.6
-
24
-
-
50949095202
-
Quantitative evaluation of cortical bone thickness and root proximity at maxillary interradicular sites for orthodontic mini-implant placement
-
Lim JE, Lim WH, Chun YS. Quantitative evaluation of cortical bone thickness and root proximity at maxillary interradicular sites for orthodontic mini-implant placement. Clin Anat 2008, 21:486-491.
-
(2008)
Clin Anat
, vol.21
, pp. 486-491
-
-
Lim, J.E.1
Lim, W.H.2
Chun, Y.S.3
-
25
-
-
64149125050
-
Computed tomographic analysis of tooth-bearing alveolar bone for orthodontic miniscrew placement
-
Lee KJ, Joo E, Kim KD, Lee JS, Park YC, Yu HS. Computed tomographic analysis of tooth-bearing alveolar bone for orthodontic miniscrew placement. Am J Orthod Dentofac Orthop 2009, 135:486-494.
-
(2009)
Am J Orthod Dentofac Orthop
, vol.135
, pp. 486-494
-
-
Lee, K.J.1
Joo, E.2
Kim, K.D.3
Lee, J.S.4
Park, Y.C.5
Yu, H.S.6
-
26
-
-
33745877600
-
The use of microimplants in orthodontic anchorage
-
Chen CH, Chang CS, Hsieh CH, Tseng YC, Shen YS, Huang IY, Yang CF, Chen CM. The use of microimplants in orthodontic anchorage. J Oral Maxillofac Surg 2006, 64:1209-1213.
-
(2006)
J Oral Maxillofac Surg
, vol.64
, pp. 1209-1213
-
-
Chen, C.H.1
Chang, C.S.2
Hsieh, C.H.3
Tseng, Y.C.4
Shen, Y.S.5
Huang, I.Y.6
Yang, C.F.7
Chen, C.M.8
-
27
-
-
63749112278
-
Tomographic mapping of mandibular interradicular spaces for placement of orthodontic mini-implants
-
Monnerat C, Restle L, Mucha JN. Tomographic mapping of mandibular interradicular spaces for placement of orthodontic mini-implants. Am J Orthod Dentofac Orthop 2009, 135:428-429.
-
(2009)
Am J Orthod Dentofac Orthop
, vol.135
, pp. 428-429
-
-
Monnerat, C.1
Restle, L.2
Mucha, J.N.3
-
28
-
-
33644856915
-
Structural and radiological parameters for the characterization of jawbone
-
Stoppie N, Pattijn V, Van Cleynenbreugel T, Wevers M, Vander Sloten J, Ignace N. Structural and radiological parameters for the characterization of jawbone. Clin Oral Implants Res 2006, 17:124-133.
-
(2006)
Clin Oral Implants Res
, vol.17
, pp. 124-133
-
-
Stoppie, N.1
Pattijn, V.2
Van Cleynenbreugel, T.3
Wevers, M.4
Vander Sloten, J.5
Ignace, N.6
-
29
-
-
34248192882
-
Bone density assessments of dental implant sites: 3. Bone quality evaluation during osteotomy and implant placement
-
Lee S, Gantes B, Riggs M, Crigger M. Bone density assessments of dental implant sites: 3. Bone quality evaluation during osteotomy and implant placement. Int J Oral Maxillofac Implants 2007, 22:208-212.
-
(2007)
Int J Oral Maxillofac Implants
, vol.22
, pp. 208-212
-
-
Lee, S.1
Gantes, B.2
Riggs, M.3
Crigger, M.4
-
30
-
-
33745204432
-
The application of mini-implants for orthodontic anchorage
-
Tseng YC, Hsieh CH, Chen CH, Shen YS, Huang IY, Chen CM. The application of mini-implants for orthodontic anchorage. Int J Oral Maxillofac Surg 2006, 35:704-707.
-
(2006)
Int J Oral Maxillofac Surg
, vol.35
, pp. 704-707
-
-
Tseng, Y.C.1
Hsieh, C.H.2
Chen, C.H.3
Shen, Y.S.4
Huang, I.Y.5
Chen, C.M.6
-
31
-
-
55149125597
-
Determination of bone quality of 372 implant recipient sites using Hounsfield unit from computerized tomography: a clinical study
-
Turkyilmaz I, Ozan O, Yilmaz B, Ersoy AE. Determination of bone quality of 372 implant recipient sites using Hounsfield unit from computerized tomography: a clinical study. Clin Implant Dent Relat Res 2008, 10:238-244.
-
(2008)
Clin Implant Dent Relat Res
, vol.10
, pp. 238-244
-
-
Turkyilmaz, I.1
Ozan, O.2
Yilmaz, B.3
Ersoy, A.E.4
-
32
-
-
79959504826
-
Biomechanical characteristics of regenerated cortical bone in the canine mandible
-
Zapata U, Opperman LA, Kontogiorgos E, Elsalanty ME, Dechow PC. Biomechanical characteristics of regenerated cortical bone in the canine mandible. J Tissue Eng Regen Med 2011, 5:551-559.
-
(2011)
J Tissue Eng Regen Med
, vol.5
, pp. 551-559
-
-
Zapata, U.1
Opperman, L.A.2
Kontogiorgos, E.3
Elsalanty, M.E.4
Dechow, P.C.5
-
33
-
-
0037417008
-
Variations in cortical material properties throughout the human dentate mandible
-
Schwartz-Dabney CL, Dechow PC. Variations in cortical material properties throughout the human dentate mandible. Am J Phys Anthropol 2003, 120:252-277.
-
(2003)
Am J Phys Anthropol
, vol.120
, pp. 252-277
-
-
Schwartz-Dabney, C.L.1
Dechow, P.C.2
-
34
-
-
67949088373
-
Buccal cortical bone thickness for mini-implant placement
-
Baumgaertel S, Hans MG. Buccal cortical bone thickness for mini-implant placement. Am J Orthod Dentofac Orthop 2009, 136:230-235.
-
(2009)
Am J Orthod Dentofac Orthop
, vol.136
, pp. 230-235
-
-
Baumgaertel, S.1
Hans, M.G.2
|