-
1
-
-
34247200453
-
Systematic review of the experimental use of temporary skeletal anchorage devices in orthodontics
-
Cornelis M.A., Scheffler N.R., De Clerck H.J., Tulloch J.F., and Nyssen-Behets C. Systematic review of the experimental use of temporary skeletal anchorage devices in orthodontics. Am J Orthod Dentofacial Orthop 131 4 Suppl (2007) S52-S58
-
(2007)
Am J Orthod Dentofacial Orthop
, vol.131
, Issue.4 SUPPL
-
-
Cornelis, M.A.1
Scheffler, N.R.2
De Clerck, H.J.3
Tulloch, J.F.4
Nyssen-Behets, C.5
-
2
-
-
33748456704
-
Nonextraction treatment of an open bite with microscrew implant anchorage
-
Park H.S., Kwon O.W., and Sung J.H. Nonextraction treatment of an open bite with microscrew implant anchorage. Am J Orthod Dentofacial Orthop 130 (2006) 391-402
-
(2006)
Am J Orthod Dentofacial Orthop
, vol.130
, pp. 391-402
-
-
Park, H.S.1
Kwon, O.W.2
Sung, J.H.3
-
3
-
-
9444292898
-
Forced eruption with microscrew anchorage for preprosthetic leveling of the gingival margin
-
Roth A., Yildirim M., and Diedrich P. Forced eruption with microscrew anchorage for preprosthetic leveling of the gingival margin. J Orofac Orthop 65 (2004) 513-519
-
(2004)
J Orofac Orthop
, vol.65
, pp. 513-519
-
-
Roth, A.1
Yildirim, M.2
Diedrich, P.3
-
4
-
-
34047249052
-
Esthetic segmental retraction of maxillary anterior teeth with a palatal appliance and orthodontic mini-implants
-
Park Y.C., Choi Y.J., Choi N.C., and Lee J.S. Esthetic segmental retraction of maxillary anterior teeth with a palatal appliance and orthodontic mini-implants. Am J Orthod Dentofacial Orthop 131 (2007) 537-544
-
(2007)
Am J Orthod Dentofacial Orthop
, vol.131
, pp. 537-544
-
-
Park, Y.C.1
Choi, Y.J.2
Choi, N.C.3
Lee, J.S.4
-
5
-
-
0031266937
-
Mini-implant for orthodontic anchorage
-
Kanomi R. Mini-implant for orthodontic anchorage. J Clin Orthod 31 (1997) 763-767
-
(1997)
J Clin Orthod
, vol.31
, pp. 763-767
-
-
Kanomi, R.1
-
6
-
-
33846048891
-
Microscrew anchorage in skeletal anterior open-bite treatment
-
Xun C., Zeng X., and Wang X. Microscrew anchorage in skeletal anterior open-bite treatment. Angle Orthod 77 (2007) 47-56
-
(2007)
Angle Orthod
, vol.77
, pp. 47-56
-
-
Xun, C.1
Zeng, X.2
Wang, X.3
-
7
-
-
21644433269
-
Group distal movement of teeth using microscrew implant anchorage
-
Park H.S., Lee S.K., and Kwon O.W. Group distal movement of teeth using microscrew implant anchorage. Angle Orthod 75 (2005) 602-609
-
(2005)
Angle Orthod
, vol.75
, pp. 602-609
-
-
Park, H.S.1
Lee, S.K.2
Kwon, O.W.3
-
8
-
-
12444293764
-
A radiographic evaluation of the availability of bone for placement of miniscrews
-
Schnelle M.A., Beck F.M., Jaynes R.M., and Huja S.S. A radiographic evaluation of the availability of bone for placement of miniscrews. Angle Orthod 74 (2004) 832-837
-
(2004)
Angle Orthod
, vol.74
, pp. 832-837
-
-
Schnelle, M.A.1
Beck, F.M.2
Jaynes, R.M.3
Huja, S.S.4
-
9
-
-
33644639434
-
"Safe zones": a guide for miniscrew positioning in the maxillary and mandibular arch
-
Poggio P.M., Incorvati C., Velo S., and Carano A. "Safe zones": a guide for miniscrew positioning in the maxillary and mandibular arch. Angle Orthod 76 (2006) 191-197
-
(2006)
Angle Orthod
, vol.76
, pp. 191-197
-
-
Poggio, P.M.1
Incorvati, C.2
Velo, S.3
Carano, A.4
-
10
-
-
33745835122
-
Factors affecting the clinical success of screw implants used as orthodontic anchorage
-
Park H.S., Jeong S.H., and Kwon O.W. Factors affecting the clinical success of screw implants used as orthodontic anchorage. Am J Orthod Dentofacial Orthop 130 (2006) 18-25
-
(2006)
Am J Orthod Dentofacial Orthop
, vol.130
, pp. 18-25
-
-
Park, H.S.1
Jeong, S.H.2
Kwon, O.W.3
-
11
-
-
34247167529
-
Risks and complications of orthodontic miniscrews
-
Kravitz N.D., and Kusnoto B. Risks and complications of orthodontic miniscrews. Am J Orthod Dentofacial Orthop 131 4 Suppl (2007) S43-S51
-
(2007)
Am J Orthod Dentofacial Orthop
, vol.131
, Issue.4 SUPPL
-
-
Kravitz, N.D.1
Kusnoto, B.2
-
13
-
-
0141831225
-
Evaluation of bone thickness in the anterior hard palate relative to midsagittal orthodontic implants
-
Henriksen B., Bavitz B., Kelly B., and Harn S.D. Evaluation of bone thickness in the anterior hard palate relative to midsagittal orthodontic implants. Int J Oral Maxillofac Implants 18 (2003) 578-581
-
(2003)
Int J Oral Maxillofac Implants
, vol.18
, pp. 578-581
-
-
Henriksen, B.1
Bavitz, B.2
Kelly, B.3
Harn, S.D.4
-
14
-
-
34247151074
-
Bone thickness of the palate for orthodontic mini-implant anchorage in adults
-
Kang S., Lee S.J., Ahn S.J., Heo M.S., and Kim T.W. Bone thickness of the palate for orthodontic mini-implant anchorage in adults. Am J Orthod Dentofacial Orthop 131 4 Suppl (2007) S74-S81
-
(2007)
Am J Orthod Dentofacial Orthop
, vol.131
, Issue.4 SUPPL
-
-
Kang, S.1
Lee, S.J.2
Ahn, S.J.3
Heo, M.S.4
Kim, T.W.5
-
15
-
-
33747022994
-
Soft-tissue and cortical-bone thickness at orthodontic implant sites
-
Kim H.J., Yun H.S., Park H.D., Kim D.H., and Park Y.C. Soft-tissue and cortical-bone thickness at orthodontic implant sites. Am J Orthod Dentofacial Orthop 130 (2006) 177-182
-
(2006)
Am J Orthod Dentofacial Orthop
, vol.130
, pp. 177-182
-
-
Kim, H.J.1
Yun, H.S.2
Park, H.D.3
Kim, D.H.4
Park, Y.C.5
-
16
-
-
0029353514
-
Implant prosthodontic treatment options for the edentulous patient
-
Zarb G.A., and Schmitt A. Implant prosthodontic treatment options for the edentulous patient. J Oral Rehabil 22 (1995) 661-671
-
(1995)
J Oral Rehabil
, vol.22
, pp. 661-671
-
-
Zarb, G.A.1
Schmitt, A.2
-
17
-
-
0002172340
-
Patient selection and preparation
-
Branemark P.I., Zarb G.A., and Albrektsson T. (Eds), Quintessence, Chicago
-
Lekholm U., and Zarb G.A. Patient selection and preparation. In: Branemark P.I., Zarb G.A., and Albrektsson T. (Eds). Tissue-integrated prosthesis: osseointegration in clinical dentistry (1985), Quintessence, Chicago 199-209
-
(1985)
Tissue-integrated prosthesis: osseointegration in clinical dentistry
, pp. 199-209
-
-
Lekholm, U.1
Zarb, G.A.2
-
18
-
-
0031309247
-
Influence of bone quality on stress distribution for endosseous implants
-
Holmes D.C., and Loftus J.T. Influence of bone quality on stress distribution for endosseous implants. J Oral Implantol 23 (1997) 104-111
-
(1997)
J Oral Implantol
, vol.23
, pp. 104-111
-
-
Holmes, D.C.1
Loftus, J.T.2
-
19
-
-
0036082588
-
Bone mineral density measurement with dental quantitative CT prior to dental implant placement in cadaver mandibles: pilot study
-
Homolka P., Beer A., Birkfellner W., Nowotny R., Gahleitner A., Tschabitscher M., et al. Bone mineral density measurement with dental quantitative CT prior to dental implant placement in cadaver mandibles: pilot study. Radiology 224 (2002) 247-252
-
(2002)
Radiology
, vol.224
, pp. 247-252
-
-
Homolka, P.1
Beer, A.2
Birkfellner, W.3
Nowotny, R.4
Gahleitner, A.5
Tschabitscher, M.6
-
20
-
-
28844480575
-
Influence of cortical bone thickness and implant length on implant stability at the time of surgery-clinical, prospective, biomechanical, and imaging study
-
Miyamoto I., Tsuboi Y., Wada E., Suwa H., and Iizuka T. Influence of cortical bone thickness and implant length on implant stability at the time of surgery-clinical, prospective, biomechanical, and imaging study. Bone 37 (2005) 776-780
-
(2005)
Bone
, vol.37
, pp. 776-780
-
-
Miyamoto, I.1
Tsuboi, Y.2
Wada, E.3
Suwa, H.4
Iizuka, T.5
-
21
-
-
33744458766
-
Parameters affecting primary stability of orthodontic mini-implants
-
Wilmes B., Rademacher C., Olthoff G., and Drescher D. Parameters affecting primary stability of orthodontic mini-implants. J Orofac Orthop 67 (2006) 162-174
-
(2006)
J Orofac Orthop
, vol.67
, pp. 162-174
-
-
Wilmes, B.1
Rademacher, C.2
Olthoff, G.3
Drescher, D.4
-
22
-
-
33751351701
-
Assessment of correlation between computerized tomography values of the bone, and maximum torque and resonance frequency values at dental implant placement
-
Turkyilmaz I., Tozum T.F., Tumer C., and Ozbek E.N. Assessment of correlation between computerized tomography values of the bone, and maximum torque and resonance frequency values at dental implant placement. J Oral Rehabil 33 (2006) 881-888
-
(2006)
J Oral Rehabil
, vol.33
, pp. 881-888
-
-
Turkyilmaz, I.1
Tozum, T.F.2
Tumer, C.3
Ozbek, E.N.4
-
23
-
-
0029440426
-
-
Friberg B, Sennerby L, Roos J, Lekholm U. Identification of bone quality in conjunction with insertion of titanium implants. A pilot study in jaw autopsy specimensClin Oral Implants Res199;6:213-9.
-
Friberg B, Sennerby L, Roos J, Lekholm U. Identification of bone quality in conjunction with insertion of titanium implants. A pilot study in jaw autopsy specimensClin Oral Implants Res199;6:213-9.
-
-
-
-
24
-
-
33744930120
-
Quantitative evaluation of cortical bone thickness with computed tomographic scanning for orthodontic implants
-
e7-12
-
Deguchi T., Nasu M., Murakami K., Yabuuchi T., Kamioka H., and Takano-Yamamoto T. Quantitative evaluation of cortical bone thickness with computed tomographic scanning for orthodontic implants. Am J Orthod Dentofacial Orthop 129 (2006) 721 e7-12
-
(2006)
Am J Orthod Dentofacial Orthop
, vol.129
, pp. 721
-
-
Deguchi, T.1
Nasu, M.2
Murakami, K.3
Yabuuchi, T.4
Kamioka, H.5
Takano-Yamamoto, T.6
-
25
-
-
0022706237
-
A clinical study of the width of the attached gingiva in the deciduous, transitional and permanent dentitions
-
Tenenbaum H., and Tenenbaum M. A clinical study of the width of the attached gingiva in the deciduous, transitional and permanent dentitions. J Clin Periodontol 13 (1986) 270-275
-
(1986)
J Clin Periodontol
, vol.13
, pp. 270-275
-
-
Tenenbaum, H.1
Tenenbaum, M.2
-
26
-
-
14244264415
-
Analysis of the accuracy of linear measurements obtained by cone beam computerized tomography (CBCT-NewTom)
-
Lascala C.A., Panella J., and Marques M.M. Analysis of the accuracy of linear measurements obtained by cone beam computerized tomography (CBCT-NewTom). Dentomaxillofac Radiol 33 (2004) 291-294
-
(2004)
Dentomaxillofac Radiol
, vol.33
, pp. 291-294
-
-
Lascala, C.A.1
Panella, J.2
Marques, M.M.3
|