메뉴 건너뛰기




Volumn 38, Issue 1, 2009, Pages 13-18

The effect of cortical bone thickness on the stability of orthodontic mini-implants and on the stress distribution in surrounding bone

Author keywords

finite element method; microimplant; mini screw; temporary anchorage devices

Indexed keywords

ADOLESCENT; ADULT; ARTICLE; BIOMECHANICS; BONE STRESS; CANCELLOUS BONE; CORTICAL BONE; CORTICAL BONE THICKNESS; FEMALE; FINITE ELEMENT ANALYSIS; HUMAN; IMPLANT; MAJOR CLINICAL STUDY; MALE; MATHEMATICAL MODEL; MORPHOMETRICS; ORTHODONTICS; SIMULATION; THICKNESS;

EID: 58149291870     PISSN: 09015027     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ijom.2008.09.006     Document Type: Article
Times cited : (158)

References (22)
  • 3
    • 33744930120 scopus 로고    scopus 로고
    • Quantitative evaluation of cortical bone thickness with computed tomographic scanning for orthodontic implants
    • e7-721.e12
    • Deguchi T., Nasu M., Murakami K., Yabuuchi T., Kamioka H., and Takano-Yamamoto T. Quantitative evaluation of cortical bone thickness with computed tomographic scanning for orthodontic implants. Amer J Orthod Dentofac Orthop 129 (2006) 721 e7-721.e12
    • (2006) Amer J Orthod Dentofac Orthop , vol.129 , pp. 721
    • Deguchi, T.1    Nasu, M.2    Murakami, K.3    Yabuuchi, T.4    Kamioka, H.5    Takano-Yamamoto, T.6
  • 4
    • 0035432240 scopus 로고    scopus 로고
    • Bicortical titanium screws for critical orthodontic anchorage in the mandible: A preliminary report on clinical applications
    • Freudenthaler J.W., Bantleon H.P., and Haas R. Bicortical titanium screws for critical orthodontic anchorage in the mandible: A preliminary report on clinical applications. Clin Oral Impl Res 12 (2001) 358-363
    • (2001) Clin Oral Impl Res , vol.12 , pp. 358-363
    • Freudenthaler, J.W.1    Bantleon, H.P.2    Haas, R.3
  • 5
    • 33746792428 scopus 로고    scopus 로고
    • Mini-implant anchorage for maxillary canine retraction: a pilot study
    • Herman R.J., Currier G.F., and Miyake A. Mini-implant anchorage for maxillary canine retraction: a pilot study. Amer J Orthod Dentofac Orthop 130 (2006) 228-235
    • (2006) Amer J Orthod Dentofac Orthop , vol.130 , pp. 228-235
    • Herman, R.J.1    Currier, G.F.2    Miyake, A.3
  • 6
    • 0031986671 scopus 로고    scopus 로고
    • Evaluating parameters of osseointegrated dental implants using finite element analysis--a two-dimensional comparative study examining the effects of implant diameter, implant shape, and load direction
    • Holmgren E.P., Seckinger R.J., Kilgren L.M., and Mante F. Evaluating parameters of osseointegrated dental implants using finite element analysis--a two-dimensional comparative study examining the effects of implant diameter, implant shape, and load direction. J Oral Implantol 24 (1998) 80-88
    • (1998) J Oral Implantol , vol.24 , pp. 80-88
    • Holmgren, E.P.1    Seckinger, R.J.2    Kilgren, L.M.3    Mante, F.4
  • 8
    • 0034232309 scopus 로고    scopus 로고
    • Basic study of the measurement of bone mineral content of cortical and cancellous bone of the mandible by computed tomography
    • Iwashita Y. Basic study of the measurement of bone mineral content of cortical and cancellous bone of the mandible by computed tomography. Dentomaxillofac radiol 29 (2000) 209-215
    • (2000) Dentomaxillofac radiol , vol.29 , pp. 209-215
    • Iwashita, Y.1
  • 9
    • 0031266937 scopus 로고    scopus 로고
    • Mini-implant for orthodontic anchorage
    • Kanomi R. Mini-implant for orthodontic anchorage. J Clin Orthod 31 (1997) 763-767
    • (1997) J Clin Orthod , vol.31 , pp. 763-767
    • Kanomi, R.1
  • 10
    • 33750805241 scopus 로고    scopus 로고
    • Correction of deep overbite and gummy smile by using a mini-implant with a segmented wire in a growing Class II Division 2 patient
    • Kim T.W., Kim H., and Lee S.J. Correction of deep overbite and gummy smile by using a mini-implant with a segmented wire in a growing Class II Division 2 patient. Amer J Orthod Dentofac Orthop 130 (2006) 676-685
    • (2006) Amer J Orthod Dentofac Orthop , vol.130 , pp. 676-685
    • Kim, T.W.1    Kim, H.2    Lee, S.J.3
  • 11
    • 84989565560 scopus 로고
    • Trabecular bone mineral density of mandible and alveolar height in postmenopausal women
    • Klemetti E., Vainio P., Lassila V., and Alhava E. Trabecular bone mineral density of mandible and alveolar height in postmenopausal women. Scand J Dent Res 101 (1993) 166-170
    • (1993) Scand J Dent Res , vol.101 , pp. 166-170
    • Klemetti, E.1    Vainio, P.2    Lassila, V.3    Alhava, E.4
  • 12
    • 0035492033 scopus 로고    scopus 로고
    • Micro-implant anchorage for lingual treatment of a skeletal class II malocclusion
    • Lee J.S., Park H.S., and Kyung H.M. Micro-implant anchorage for lingual treatment of a skeletal class II malocclusion. J Clin Orthod 35 (2001) 643-647
    • (2001) J Clin Orthod , vol.35 , pp. 643-647
    • Lee, J.S.1    Park, H.S.2    Kyung, H.M.3
  • 13
    • 34447646710 scopus 로고    scopus 로고
    • A mathematical model for simulating the bone remodeling process under mechanical stimulus
    • Li J., Li H., Shi L., Fok A.S.L., Ucer C., Devlin H., Horner K., and Silikas N. A mathematical model for simulating the bone remodeling process under mechanical stimulus. Dent Mater 23 (2007) 1073-1078
    • (2007) Dent Mater , vol.23 , pp. 1073-1078
    • Li, J.1    Li, H.2    Shi, L.3    Fok, A.S.L.4    Ucer, C.5    Devlin, H.6    Horner, K.7    Silikas, N.8
  • 14
    • 0141921987 scopus 로고    scopus 로고
    • Factors associated with the stability of titanium screws placed in the posterior region for orthodontic anchorage
    • Miyawaki S., Koyama I., Inoue M., Mishima K., Sugawara T., and Yamamoto T. Factors associated with the stability of titanium screws placed in the posterior region for orthodontic anchorage. Amer J Orthod Dentofac Orthop 124 (2003) 373-378
    • (2003) Amer J Orthod Dentofac Orthop , vol.124 , pp. 373-378
    • Miyawaki, S.1    Koyama, I.2    Inoue, M.3    Mishima, K.4    Sugawara, T.5    Yamamoto, T.6
  • 15
    • 33645054577 scopus 로고    scopus 로고
    • Recommended placement torque when tightening an orthodontic mini-implant
    • Motoyoshi M., Hirabayashi M., Uemura M., and Shimizu N. Recommended placement torque when tightening an orthodontic mini-implant. Clin Oral Impl Res 17 (2006) 109-114
    • (2006) Clin Oral Impl Res , vol.17 , pp. 109-114
    • Motoyoshi, M.1    Hirabayashi, M.2    Uemura, M.3    Shimizu, N.4
  • 16
    • 35649012521 scopus 로고    scopus 로고
    • Effect of cortical bone thickness and implant placement torque on stability of orthodontic mini-implant
    • Motoyoshi M., Yoshida T., Ono A., and Shimizu N. Effect of cortical bone thickness and implant placement torque on stability of orthodontic mini-implant. Int J Oral Maxillofac Impl 22 (2007) 779-784
    • (2007) Int J Oral Maxillofac Impl , vol.22 , pp. 779-784
    • Motoyoshi, M.1    Yoshida, T.2    Ono, A.3    Shimizu, N.4
  • 18
    • 0036777545 scopus 로고    scopus 로고
    • A simple method of molar uprighting with microimplant anchorage
    • Park H.S., Kyung H.M., and Sung J.H. A simple method of molar uprighting with microimplant anchorage. J Clin Orthod 36 (2002) 592-596
    • (2002) J Clin Orthod , vol.36 , pp. 592-596
    • Park, H.S.1    Kyung, H.M.2    Sung, J.H.3
  • 19
    • 32644436644 scopus 로고    scopus 로고
    • The resonance frequencies and mode shapes of dental implants: rigid body behaviour versus bending behaviour. a numerical approach
    • Pattijna V., Lierdeb C.V., Perrea G.V., Naertc I., and Slotena J.V. The resonance frequencies and mode shapes of dental implants: rigid body behaviour versus bending behaviour. a numerical approach. J Biomech 39 (2006) 939-947
    • (2006) J Biomech , vol.39 , pp. 939-947
    • Pattijna, V.1    Lierdeb, C.V.2    Perrea, G.V.3    Naertc, I.4    Slotena, J.V.5
  • 20
    • 0141972555 scopus 로고    scopus 로고
    • The new method for the maxillary retraction of the anterior teeth using a titanium microscrew as anchorage
    • Sawa Y., Goto K., Suzuki N., Kamo N., and Kamo K. The new method for the maxillary retraction of the anterior teeth using a titanium microscrew as anchorage. Orthod Waves 60 (2001) 328-331
    • (2001) Orthod Waves , vol.60 , pp. 328-331
    • Sawa, Y.1    Goto, K.2    Suzuki, N.3    Kamo, N.4    Kamo, K.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.