메뉴 건너뛰기




Volumn 25, Issue 7, 2014, Pages 771-773

Remote monitoring of patients with implantable cardioverter defibrillators (ICD): A cute gimmick or an essential tool for clinical excellence?

Author keywords

heart failure; ICD shocks; implantable cardioverter defibrillator; remote monitoring; ventricular tachycardia

Indexed keywords

ACUTE HEART FAILURE; ALGORITHM; ARTIFICIAL HEART PACEMAKER; BATTERY DEPLETION; CARDIAC RESYNCHRONIZATION THERAPY; CARDIOVASCULAR MORTALITY; CONVULSIVE THERAPY; COST BENEFIT ANALYSIS; EDITORIAL; ELECTRIC BATTERY; ELECTRONIC MEDICAL RECORD; FOLLOW UP; HEALTH MAINTENANCE ORGANIZATION; HEART ATRIUM ARRHYTHMIA; HEART SUPRAVENTRICULAR ARRHYTHMIA; HEART VENTRICLE ARRHYTHMIA; HEART VENTRICLE TACHYCARDIA; HOME MONITORING; HUMAN; IMPLANTABLE CARDIOVERTER DEFIBRILLATOR; LEAD MALFUNCTION; LEGAL LIABILITY; MEDICAL DEVICE COMPLICATION; PATIENT COMPLIANCE; PRIMARY PREVENTION; PRIORITY JOURNAL; REIMBURSEMENT; REMOTE SENSING; SUDDEN CARDIAC DEATH; SURVIVAL; WEB BROWSER; ADVERSE EFFECTS; ARRHYTHMIAS, CARDIAC; FEMALE; MALE;

EID: 84904444077     PISSN: 10453873     EISSN: 15408167     Source Type: Journal    
DOI: 10.1111/jce.12415     Document Type: Editorial
Times cited : (3)

References (41)
  • 2
    • 44649122064 scopus 로고    scopus 로고
    • HRS/EHRA expert consensus on the monitoring of cardiovascular implantable electronic devices (CIEDs)
    • Description of techniques, indications, personnel, frequency and ethical considerations: Developed in partnership with the Heart Rhythm Society (HRS) and the European Heart Rhythm Association (EHRA); And in collaboration with the American College of Cardiology (ACC), the American Heart Association (AHA), the European Society of Cardiology (ESC), the Heart Failure Association of ESC (HFA), and the Heart Failure Society of America (HFSA). Endorsed by the Heart Rhythm Society, the European Heart Rhythm Association (a registered branch of the ESC), the American College of Cardiology, the American Heart Association
    • Wilkoff BL, Auricchio A, Brugada J, Cowie M, Ellenbogen KA, Gillis AM, Hayes DL, Howlett JG, Kautzner J, Love CJ, Morgan JM, Priori SG, Reynolds DW, Schoenfeld MH, Vardas PE,: HRS/EHRA expert consensus on the monitoring of cardiovascular implantable electronic devices (CIEDs): Description of techniques, indications, personnel, frequency and ethical considerations: Developed in partnership with the Heart Rhythm Society (HRS) and the European Heart Rhythm Association (EHRA); and in collaboration with the American College of Cardiology (ACC), the American Heart Association (AHA), the European Society of Cardiology (ESC), the Heart Failure Association of ESC (HFA), and the Heart Failure Society of America (HFSA). Endorsed by the Heart Rhythm Society, the European Heart Rhythm Association (a registered branch of the ESC), the American College of Cardiology, the American Heart Association. Europace 2008; 10: 707-725.
    • (2008) Europace , vol.10 , pp. 707-725
    • Wilkoff, B.L.1    Auricchio, A.2    Brugada, J.3    Cowie, M.4    Ellenbogen, K.A.5    Gillis, A.M.6    Hayes, D.L.7    Howlett, J.G.8    Kautzner, J.9    Love, C.J.10    Morgan, J.M.11    Priori, S.G.12    Reynolds, D.W.13    Schoenfeld, M.H.14    Vardas, P.E.15
  • 3
    • 80051741363 scopus 로고    scopus 로고
    • Healthcare personnel resource burden related to in-clinic follow-up of cardiovascular implantable electronic devices: A European Heart Rhythm Association and Eucomed joint survey
    • Boriani G, Auricchio A, Klersy C, Kirchhof P, Brugada J, Morgan J, Vardas P,: Healthcare personnel resource burden related to in-clinic follow-up of cardiovascular implantable electronic devices: A European Heart Rhythm Association and Eucomed joint survey. Europace 2011; 13: 1166-1173.
    • (2011) Europace , vol.13 , pp. 1166-1173
    • Boriani, G.1    Auricchio, A.2    Klersy, C.3    Kirchhof, P.4    Brugada, J.5    Morgan, J.6    Vardas, P.7
  • 4
    • 84878927721 scopus 로고    scopus 로고
    • Current clinical evidence for remote patient management
    • Guedon-Moreau L, Mabo P, Kacet S,: Current clinical evidence for remote patient management. Europace 2013; 15: i6-i10.
    • (2013) Europace , vol.15
    • Guedon-Moreau, L.1    Mabo, P.2    Kacet, S.3
  • 6
    • 84878907565 scopus 로고    scopus 로고
    • Effectiveness of remote monitoring of CIEDs in detection and treatment of clinical and device-related cardiovascular events in daily practice: The HomeGuide Registry
    • Ricci RP, Morichelli L, D'Onofrio A, Calo L, Vaccari D, Zanotto G, Curnis A, Buja G, Rovai N, Gargaro A,: Effectiveness of remote monitoring of CIEDs in detection and treatment of clinical and device-related cardiovascular events in daily practice: The HomeGuide Registry. Europace 2013; 15: 970-977.
    • (2013) Europace , vol.15 , pp. 970-977
    • Ricci, R.P.1    Morichelli, L.2    D'Onofrio, A.3    Calo, L.4    Vaccari, D.5    Zanotto, G.6    Curnis, A.7    Buja, G.8    Rovai, N.9    Gargaro, A.10
  • 7
    • 84886519792 scopus 로고    scopus 로고
    • Quarterly vs yearly clinical follow-up of remotely monitored recipients of prophylactic implantable cardioverter-defibrillators Results of the REFORM trial
    • Hindricks G, Elsner C, Piorkowski C, Taborsky M, Geller JC, Schumacher B, Bytesnik J, Kottkamp H,: Quarterly vs. yearly clinical follow-up of remotely monitored recipients of prophylactic implantable cardioverter-defibrillators: Results of the REFORM trial. Eur Heart J 2014; 35: 98-105.
    • (2014) Eur Heart J , vol.35 , pp. 98-105
    • Hindricks, G.1    Elsner, C.2    Piorkowski, C.3    Taborsky, M.4    Geller, J.C.5    Schumacher, B.6    Bytesnik, J.7    Kottkamp, H.8
  • 8
    • 84901834727 scopus 로고    scopus 로고
    • Cost-consequence analysis of daily continuous remote monitoring of implantable cardiac defibrillator and resynchronization devices in the UK
    • Burri H, Sticherling C, Wright D, Makino K, Smala A, Tilden D,: Cost-consequence analysis of daily continuous remote monitoring of implantable cardiac defibrillator and resynchronization devices in the UK. Europace 2013; 15: 1601-1608.
    • (2013) Europace , vol.15 , pp. 1601-1608
    • Burri, H.1    Sticherling, C.2    Wright, D.3    Makino, K.4    Smala, A.5    Tilden, D.6
  • 10
    • 78049502576 scopus 로고    scopus 로고
    • Automatic remote monitoring of implantable cardioverter-defibrillator lead and generator performance: The Lumos-T Safely RedUceS RouTine Office Device Follow-Up (TRUST) Trial
    • Varma N, Michalski J, Epstein AE, Schweikert R,: Automatic remote monitoring of implantable cardioverter-defibrillator lead and generator performance: The Lumos-T Safely RedUceS RouTine Office Device Follow-Up (TRUST) Trial. Circ Arrhythm Electrophysiol 2010; 3: 428-436.
    • (2010) Circ Arrhythm Electrophysiol , vol.3 , pp. 428-436
    • Varma, N.1    Michalski, J.2    Epstein, A.E.3    Schweikert, R.4
  • 11
    • 65249116913 scopus 로고    scopus 로고
    • Potential role of home monitoring to reduce inappropriate shocks in implantable cardioverter-defibrillator patients due to lead failure
    • Spencker S, Coban N, Koch L, Schirdewan A, Muller D,: Potential role of home monitoring to reduce inappropriate shocks in implantable cardioverter-defibrillator patients due to lead failure. Europace 2009; 11: 483-488.
    • (2009) Europace , vol.11 , pp. 483-488
    • Spencker, S.1    Coban, N.2    Koch, L.3    Schirdewan, A.4    Muller, D.5
  • 13
    • 84863718727 scopus 로고    scopus 로고
    • Prognostic significance of implantable defibrillator shock: Are all shocks created equal?
    • Freedberg N, Feldman A,: Prognostic significance of implantable defibrillator shock: Are all shocks created equal? J Cardiovasc Electrophysiol 2012; 23: 741-743.
    • (2012) J Cardiovasc Electrophysiol , vol.23 , pp. 741-743
    • Freedberg, N.1    Feldman, A.2
  • 14
    • 60849136605 scopus 로고    scopus 로고
    • Prevalence of cancelled shock therapy and relationship to shock delivery in recipients of implantable cardioverter-defibrillators assessed by remote monitoring
    • Varma N, Johnson M,: Prevalence of cancelled shock therapy and relationship to shock delivery in recipients of implantable cardioverter- defibrillators assessed by remote monitoring. Pacing Clin Electrophysiol 2009; 32 (Suppl 1): S42-S46.
    • (2009) Pacing Clin Electrophysiol , vol.32 , Issue.1 SUPPL.
    • Varma, N.1    Johnson, M.2
  • 19
    • 79959962424 scopus 로고    scopus 로고
    • Fluid status monitoring with a wireless network to reduce cardiovascular-related hospitalizations and mortality in heart failure: Rationale and design of the OptiLink HF Study (Optimization of Heart Failure Management using OptiVol Fluid Status Monitoring and CareLink)
    • Board obotOHSE, Investigators
    • Brachmann J, Böhm M, Rybak K, Klein G, Butter C, Klemm H, Schomburg R, Siebermair J, Israel C, Sinha A-M, Drexler H, Board obotOHSE, Investigators: Fluid status monitoring with a wireless network to reduce cardiovascular-related hospitalizations and mortality in heart failure: Rationale and design of the OptiLink HF Study (Optimization of Heart Failure Management using OptiVol Fluid Status Monitoring and CareLink). Eur J Heart Fail 2011; 13: 796-804.
    • (2011) Eur J Heart Fail , vol.13 , pp. 796-804
    • Brachmann, J.1    Böhm, M.2    Rybak, K.3    Klein, G.4    Butter, C.5    Klemm, H.6    Schomburg, R.7    Siebermair, J.8    Israel, C.9    Sinha, A.-M.10    Drexler, H.11
  • 20
    • 84881479500 scopus 로고    scopus 로고
    • Development and validation of an integrated diagnostic algorithm derived from parameters monitored in implantable devices for identifying patients at risk for heart failure hospitalization in an ambulatory setting
    • Cowie MR, Sarkar S, Koehler J, Whellan DJ, Crossley GH, Tang WHW, Abraham WT, Sharma V, Santini M,: Development and validation of an integrated diagnostic algorithm derived from parameters monitored in implantable devices for identifying patients at risk for heart failure hospitalization in an ambulatory setting. Eur Heart J 2013; 34: 2472-2480.
    • (2013) Eur Heart J , vol.34 , pp. 2472-2480
    • Cowie, M.R.1    Sarkar, S.2    Koehler, J.3    Whellan, D.J.4    Crossley, G.H.5    Tang, W.H.W.6    Abraham, W.T.7    Sharma, V.8    Santini, M.9
  • 21
    • 77955171126 scopus 로고    scopus 로고
    • Efficacy and safety of automatic remote monitoring for implantable cardioverter-defibrillator follow-up: The Lumos-T Safely Reduces Routine Office Device Follow-Up (TRUST) Trial
    • for the TRUST Investigators
    • Varma N, Epstein AE, Irimpen A, Schweikert R, Love C, for the TRUST Investigators: Efficacy and safety of automatic remote monitoring for implantable cardioverter-defibrillator follow-up: The Lumos-T Safely Reduces Routine Office Device Follow-Up (TRUST) Trial. Circulation 2010; 122: 325-332.
    • (2010) Circulation , vol.122 , pp. 325-332
    • Varma, N.1    Epstein, A.E.2    Irimpen, A.3    Schweikert, R.4    Love, C.5
  • 22
    • 79952312933 scopus 로고    scopus 로고
    • The CONNECT (Clinical Evaluation of Remote Notification to Reduce Time to Clinical Decision) trial: The value of wireless remote monitoring with automatic clinician alerts
    • Crossley G, Boyle A, Vitense H, Chang Y, Mead R,: The CONNECT (Clinical Evaluation of Remote Notification to Reduce Time to Clinical Decision) trial: The value of wireless remote monitoring with automatic clinician alerts. J Am Coll Cardiol 2011; 57: 1181-1189.
    • (2011) J Am Coll Cardiol , vol.57 , pp. 1181-1189
    • Crossley, G.1    Boyle, A.2    Vitense, H.3    Chang, Y.4    Mead, R.5
  • 23
    • 84862519332 scopus 로고    scopus 로고
    • Remote monitoring reduces healthcare use and improves quality of care in heart failure patients with implantable defibrillators: The evolution of management strategies of heart failure patients with implantable defibrillators (EVOLVO) study
    • Landolina M, Perego GB, Lunati M, Curnis A, Guenzati G, Vicentini A, Parati G, Borghi G, Zanaboni P, Valsecchi S, Marzegalli M,: Remote monitoring reduces healthcare use and improves quality of care in heart failure patients with implantable defibrillators: The evolution of management strategies of heart failure patients with implantable defibrillators (EVOLVO) study. Circulation 2012; 125: 2985-2992.
    • (2012) Circulation , vol.125 , pp. 2985-2992
    • Landolina, M.1    Perego, G.B.2    Lunati, M.3    Curnis, A.4    Guenzati, G.5    Vicentini, A.6    Parati, G.7    Borghi, G.8    Zanaboni, P.9    Valsecchi, S.10    Marzegalli, M.11
  • 24
    • 84874478830 scopus 로고    scopus 로고
    • A randomized study of remote follow-up of implantable cardioverter defibrillators: Safety and efficacy report of the ECOST trial
    • for the ECOST trial Investigators
    • Guedon-Moreau L, Lacroix D, Sadoul N, Clementy J, Kouakam C, Hermida J-S, Aliot E, Boursier M, Bizeau O, Kacet S, for the ECOST trial Investigators: A randomized study of remote follow-up of implantable cardioverter defibrillators: Safety and efficacy report of the ECOST trial. Eur Heart J 2013; 34: 605-614.
    • (2013) Eur Heart J , vol.34 , pp. 605-614
    • Guedon-Moreau, L.1    Lacroix, D.2    Sadoul, N.3    Clementy, J.4    Kouakam, C.5    Hermida, J.-S.6    Aliot, E.7    Boursier, M.8    Bizeau, O.9    Kacet, S.10
  • 29
    • 0006918490 scopus 로고    scopus 로고
    • Improved survival with an implanted defibrillator in patients with coronary disease at high risk for ventricular arrhythmia
    • The Multicenter Automatic Defibrillator Implantation Trial I
    • Moss AJ, Hall WJ, Cannom DS, Daubert JP, Higgins SL, Klein H, Levine JH, Saksena S, Waldo AL, Wilber D, Brown MW, Heo M, The Multicenter Automatic Defibrillator Implantation Trial I: Improved survival with an implanted defibrillator in patients with coronary disease at high risk for ventricular arrhythmia. N Engl J Med 1996; 335: 1933-1940.
    • (1996) N Engl J Med , vol.335 , pp. 1933-1940
    • Moss, A.J.1    Hall, W.J.2    Cannom, D.S.3    Daubert, J.P.4    Higgins, S.L.5    Klein, H.6    Levine, J.H.7    Saksena, S.8    Waldo, A.L.9    Wilber, D.10    Brown, M.W.11    Heo, M.12
  • 30
    • 84877289895 scopus 로고    scopus 로고
    • Effect of long-detection interval vs standard-detection interval for implantable cardioverter-defibrillators on antitachycardia pacing and shock delivery: The advance III randomized clinical trial
    • Gasparini M, Proclemer A, Klersy C, Kloppe A, Lunati M, Ferrer JB, Hersi A, Gulaj M, Wijfels MC, Santi E, Manotta L, Arenal A,: Effect of long-detection interval vs standard-detection interval for implantable cardioverter- defibrillators on antitachycardia pacing and shock delivery: The advance III randomized clinical trial. J Am Med Assoc 2013; 309: 1903-1911.
    • (2013) J Am Med Assoc , vol.309 , pp. 1903-1911
    • Gasparini, M.1    Proclemer, A.2    Klersy, C.3    Kloppe, A.4    Lunati, M.5    Ferrer, J.B.6    Hersi, A.7    Gulaj, M.8    Wijfels, M.C.9    Santi, E.10    Manotta, L.11    Arenal, A.12
  • 31
    • 84891854367 scopus 로고    scopus 로고
    • Programming implantable cardioverter-defibrillators in patients with primary prevention indication to prolong time to first shock: Results from the PROVIDE study
    • Saeed M, Hanna I, Robotis D, Styperek R, Polosajian L, Khan A, Alonso J, Nabutovsky Y, Neason C,: Programming implantable cardioverter-defibrillators in patients with primary prevention indication to prolong time to first shock: Results from the PROVIDE study. J Cardiovasc Electrophysiol 2014; 25: 52-59.
    • (2014) J Cardiovasc Electrophysiol , vol.25 , pp. 52-59
    • Saeed, M.1    Hanna, I.2    Robotis, D.3    Styperek, R.4    Polosajian, L.5    Khan, A.6    Alonso, J.7    Nabutovsky, Y.8    Neason, C.9
  • 32
    • 72949114097 scopus 로고    scopus 로고
    • A simplified biventricular defibrillator with fixed long detection intervals reduces implantable cardioverter defibrillator (ICD)
    • Interventions and heart failure hospitalizations in patients with non-ischaemic cardiomyopathy implanted for primary prevention: The RELEVANT role of long dEtection window programming in patients with LEft VentriculAr dysfunction, Non-ischemic eTiology in primary prevention treated with a biventricular ICD. study
    • Gasparini M, Menozzi C, Proclemer A, Landolina M, Iacopino S, Carboni A, Lombardo E, Regoli F, Biffi M, Burrone V, Denaro A, Boriani G,: A simplified biventricular defibrillator with fixed long detection intervals reduces implantable cardioverter defibrillator (ICD) interventions and heart failure hospitalizations in patients with non-ischaemic cardiomyopathy implanted for primary prevention: The RELEVANT role of long dEtection window programming in patients with LEft VentriculAr dysfunction, Non-ischemic eTiology in primary prevention treated with a biventricular ICD. study. Eur Heart J 2009; 30: 2758-2767.
    • (2009) Eur Heart J , vol.30 , pp. 2758-2767
    • Gasparini, M.1    Menozzi, C.2    Proclemer, A.3    Landolina, M.4    Iacopino, S.5    Carboni, A.6    Lombardo, E.7    Regoli, F.8    Biffi, M.9    Burrone, V.10    Denaro, A.11    Boriani, G.12
  • 33
    • 84899427183 scopus 로고    scopus 로고
    • Impact of prolonged implantable cardioverter-defibrillator arrhythmia detection times on outcomes: A meta-analysis
    • doi: 10.1016/j.hrthm.2014.02.009. [Epub ahead of print]
    • Scott PA, Silberbauer J, McDonagh TA, Murgatroyd FD,: Impact of prolonged implantable cardioverter-defibrillator arrhythmia detection times on outcomes: A meta-analysis. Heart Rhythm 2014;doi: 10.1016/j.hrthm.2014.02.009. [Epub ahead of print].
    • (2014) Heart Rhythm
    • Scott, P.A.1    Silberbauer, J.2    McDonagh, T.A.3    Murgatroyd, F.D.4
  • 34
    • 0035369077 scopus 로고    scopus 로고
    • Recurrence of symptomatic ventricular arrhythmias in patients with implantable cardioverter defibrillator after the first device therapy: Implications for antiarrhythmic therapy and driving restrictions. CARE Group
    • Freedberg N, Hill J, Fogel R, Prystowsky E,: Recurrence of symptomatic ventricular arrhythmias in patients with implantable cardioverter defibrillator after the first device therapy: Implications for antiarrhythmic therapy and driving restrictions. CARE Group. J Am Coll Cardiol 2001; 37: 1910-1915.
    • (2001) J Am Coll Cardiol , vol.37 , pp. 1910-1915
    • Freedberg, N.1    Hill, J.2    Fogel, R.3    Prystowsky, E.4
  • 35
    • 77951176996 scopus 로고    scopus 로고
    • Remote monitoring of implantable cardioverter defibrillators versus quarterly device interrogations in clinic: Results from a randomized pilot clinical trial
    • Al-Khatib S, Piccini J, Knight D, Stewart M, Clapp-Channing N, Sanders G,: Remote monitoring of implantable cardioverter defibrillators versus quarterly device interrogations in clinic: Results from a randomized pilot clinical trial. J Cardiovasc Electrophysiol 2010; 21: 545-550.
    • (2010) J Cardiovasc Electrophysiol , vol.21 , pp. 545-550
    • Al-Khatib, S.1    Piccini, J.2    Knight, D.3    Stewart, M.4    Clapp-Channing, N.5    Sanders, G.6
  • 37
    • 67651040063 scopus 로고    scopus 로고
    • Remote monitoring and follow-up of pacemakers and implantable cardioverter defibrillators
    • Burri H, Senouf D,: Remote monitoring and follow-up of pacemakers and implantable cardioverter defibrillators. Europace 2009; 11: 701-709.
    • (2009) Europace , vol.11 , pp. 701-709
    • Burri, H.1    Senouf, D.2
  • 39
    • 84864542564 scopus 로고    scopus 로고
    • Legal and organizational aspects of remote cardiac monitoring: The example of implantable cardioverter defibrillators
    • Vinck I, De Laet C, Stroobandt S, Van Brabandt H,: Legal and organizational aspects of remote cardiac monitoring: The example of implantable cardioverter defibrillators. Europace 2012; 14: 1230-1235.
    • (2012) Europace , vol.14 , pp. 1230-1235
    • Vinck, I.1    De Laet, C.2    Stroobandt, S.3    Van Brabandt, H.4
  • 41
    • 84891348459 scopus 로고    scopus 로고
    • Remote monitoring of cardiac implantable electronic devices in Europe: Results of the European Heart Rhythm Association survey
    • Hernández-Madrid A, Lewalter T, Proclemer A, Pison L, Lip GYH, Blomstrom-Lundqvist C,: Remote monitoring of cardiac implantable electronic devices in Europe: Results of the European Heart Rhythm Association survey. Europace 2014; 16: 129-132.
    • (2014) Europace , vol.16 , pp. 129-132
    • Hernández-Madrid, A.1    Lewalter, T.2    Proclemer, A.3    Pison, L.4    Lip, G.Y.H.5    Blomstrom-Lundqvist, C.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.