메뉴 건너뛰기




Volumn 57, Issue 10, 2011, Pages 1181-1189

The CONNECT (Clinical Evaluation of Remote Notification to Reduce Time to Clinical Decision) trial: The value of wireless remote monitoring with automatic clinician alerts

Author keywords

alerts; cardiac resynchronization therapy; clinician notification; health care economics; implantable cardioverter defibrillator; remote patient monitoring

Indexed keywords

AGED; ARTICLE; ARTIFICIAL HEART PACEMAKER; BRADYCARDIA; CARDIAC RESYNCHRONIZATION THERAPY; CARDIOVASCULAR DISEASE; CLINICAL DECISION MAKING; CONTROLLED STUDY; DEFIBRILLATOR; DISEASE COURSE; EMERGENCY WARD; FEMALE; HEALTH CARE COST; HEALTH CARE UTILIZATION; HEART ARRHYTHMIA; HEART ATRIUM FIBRILLATION; HEART LEFT VENTRICLE EJECTION FRACTION; HOSPITALIZATION; HUMAN; INTERMETHOD COMPARISON; LENGTH OF STAY; MAJOR CLINICAL STUDY; MALE; PATIENT MONITORING; PRIORITY JOURNAL; TACHYCARDIA; WIRELESS COMMUNICATION;

EID: 79952312933     PISSN: 07351097     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jacc.2010.12.012     Document Type: Article
Times cited : (452)

References (23)
  • 4
    • 2442479695 scopus 로고    scopus 로고
    • Cardiac-resynchronization therapy with or without an implantable defibrillator in advanced chronic heart failure
    • M.R. Bristow, L.A. Saxon, and J. Boehmer Cardiac-resynchronization therapy with or without an implantable defibrillator in advanced chronic heart failure N Engl J Med 350 2004 2140 2150
    • (2004) N Engl J Med , vol.350 , pp. 2140-2150
    • Bristow, M.R.1    Saxon, L.A.2    Boehmer, J.3
  • 5
    • 59449094988 scopus 로고    scopus 로고
    • Remote monitoring of patients with biventricular defibrillators through the CareLink system improves clinical management of arrhythmias and heart failure episodes
    • M. Santini, R.P. Ricci, and M. Lunati Remote monitoring of patients with biventricular defibrillators through the CareLink system improves clinical management of arrhythmias and heart failure episodes J Interv Cardiac Electrophysiol 24 2009 53 61
    • (2009) J Interv Cardiac Electrophysiol , vol.24 , pp. 53-61
    • Santini, M.1    Ricci, R.P.2    Lunati, M.3
  • 9
    • 70449520921 scopus 로고    scopus 로고
    • The relationship between daily atrial tachyarrhythmia burden from implantable device diagnostics and stroke risk: The TRENDS study
    • T.V. Glotzer, E.G. Daoud, and D.G. Wyse The relationship between daily atrial tachyarrhythmia burden from implantable device diagnostics and stroke risk: the TRENDS study Circ Arrhyth Electrophysiol 2 2009 474 480
    • (2009) Circ Arrhyth Electrophysiol , vol.2 , pp. 474-480
    • Glotzer, T.V.1    Daoud, E.G.2    Wyse, D.G.3
  • 12
    • 54349097071 scopus 로고    scopus 로고
    • Newly recognized atrial tachyarrhythmias are fairly common and increase the risk of supraventricular shocks and cardiovascular hospitalizations in ICD Patients (abstr)
    • K.T. Ousidigan, W.B. Johnson, J. Koeler, and B.L. Wilkoff Newly recognized atrial tachyarrhythmias are fairly common and increase the risk of supraventricular shocks and cardiovascular hospitalizations in ICD Patients (abstr) Heart Rhythm 3 Suppl 2006 162 163
    • (2006) Heart Rhythm , vol.3 , Issue.SUPPL. , pp. 162-163
    • Ousidigan, K.T.1    Johnson, W.B.2    Koeler, J.3    Wilkoff, B.L.4
  • 13
    • 3242769132 scopus 로고    scopus 로고
    • Accuracy of atrial tachyarrhythmia detection in implantable devices with arrhythmia therapies
    • DOI 10.1111/j.1540-8159.2004.00569.x
    • H. Purerfellner, A.M. Gillis, R. Holbrook, and D.A. Hettrick Accuracy of atrial tachyarrhythmia detection in implantable devices with arrhythmia therapies Pacing Clin Electrophysiol 27 2004 983 992 (Pubitemid 38970216)
    • (2004) PACE - Pacing and Clinical Electrophysiology , vol.27 , Issue.7 , pp. 983-992
    • Purerfellner, H.1    Gillis, A.M.2    Holbrook, R.3    Hettrick, D.A.4
  • 16
    • 79952316736 scopus 로고    scopus 로고
    • Anatomy and Physiology
    • W.D. Ward Anatomy and Physiology E. Berger, W. Ward, J. Morrill, L. Royster, Noise and Hearing Conservation Manual 2010 American Industrial Hygiene Association Fairfax, VA 180 195
    • (2010) Noise and Hearing Conservation Manual , pp. 180-195
    • Ward, W.D.1
  • 18
    • 71849093450 scopus 로고    scopus 로고
    • Clinical benefits of remote versus transtelephonic monitoring of implanted pacemakers
    • G.H. Crossley, J. Chen, and W. Choucair Clinical benefits of remote versus transtelephonic monitoring of implanted pacemakers J Am Coll Cardiol 54 2009 2012 2019
    • (2009) J Am Coll Cardiol , vol.54 , pp. 2012-2019
    • Crossley, G.H.1    Chen, J.2    Choucair, W.3
  • 19
    • 54349086267 scopus 로고    scopus 로고
    • Trial design of the clinical evaluation of remote notification to reduce time to clinical decision: The Clinical Evaluation of Remote Notification to Reduce Time to Clinical Decision (CONNECT) study
    • G. Crossley, A. Boyle, H. Vitense, L. Sherfesee, and R.H. Mead Trial design of the clinical evaluation of remote notification to reduce time to clinical decision: the Clinical Evaluation of Remote Notification to Reduce Time to Clinical Decision (CONNECT) study Am Heart J 156 2008 840 846
    • (2008) Am Heart J , vol.156 , pp. 840-846
    • Crossley, G.1    Boyle, A.2    Vitense, H.3    Sherfesee, L.4    Mead, R.H.5
  • 20
    • 0001646484 scopus 로고
    • Cox's regression model for counting processes: A large sample study
    • P. Andersen, and R. Gill Cox's regression model for counting processes: a large sample study Ann Stat 10 1982 1100 1120
    • (1982) Ann Stat , vol.10 , pp. 1100-1120
    • Andersen, P.1    Gill, R.2
  • 21
    • 84988052086 scopus 로고
    • Negative binomial and mixed Poisson regression
    • J. Lawless Negative binomial and mixed Poisson regression Can J Stat 15 1987 209 225
    • (1987) Can J Stat , vol.15 , pp. 209-225
    • Lawless, J.1
  • 22
    • 77955171126 scopus 로고    scopus 로고
    • Efficacy and safety of automatic remote monitoring for implantable cardioverter-defibrillator follow-up: The Lumos-T Safely Reduces Routine Office Device Follow-Up (TRUST) trial
    • TRUST Investigators C.
    • N. Varma, A.E. Epstein, A. Irimpen, R. Schweikert, C. Love TRUST Investigators Efficacy and safety of automatic remote monitoring for implantable cardioverter-defibrillator follow-up: the Lumos-T Safely Reduces Routine Office Device Follow-Up (TRUST) trial Circulation 122 2010 325 332
    • (2010) Circulation , vol.122 , pp. 325-332
    • Varma, N.1    Epstein, A.E.2    Irimpen, A.3    Schweikert, R.4    Love, C.5
  • 23
    • 71849093450 scopus 로고    scopus 로고
    • Clinical benefits of remote versus transtelephonic monitoring of implanted pacemakers
    • G.H. Crossley, J. Chen, and W. Choucair Clinical benefits of remote versus transtelephonic monitoring of implanted pacemakers J Am Coll Cardiol 54 2009 2012 2019
    • (2009) J Am Coll Cardiol , vol.54 , pp. 2012-2019
    • Crossley, G.H.1    Chen, J.2    Choucair, W.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.