Volumn 25, Issue 7, 2014, Pages 763-770

Decreased delivery of inappropriate shocks achieved by remote monitoring of ICD: A substudy of the ECOST trial

Author keywords

implantable cardioverter defibrillator; inappropriate shock; lead dysfunction; oversensing; remote monitoring; telemedicine; supraventricular tachyarrhythmias

Indexed keywords

AMIODARONE; BETA ADRENERGIC RECEPTOR BLOCKING AGENT; DIGITALIS;

EID: 84904459228     PISSN: 10453873     EISSN: 15408167     Source Type: Journal    
DOI: 10.1111/jce.12405     Document Type: Article
Times cited : (73)

References (14)
  • 2
    • 33645739897 scopus 로고    scopus 로고
    • Frequency and causes of implantable cardioverter-defibrillator therapies: Is device therapy proarrhythmic?
    • Germano JJ, Reynolds M, Essebag V, Josephson ME,: Frequency and causes of implantable cardioverter-defibrillator therapies: Is device therapy proarrhythmic? Am J Cardiol 2006; 97: 1255-1261.
    • (2006) Am J Cardiol , vol.97 , pp. 1255-1261
    • Germano, J.J.1    Reynolds, M.2    Essebag, V.3    Josephson, M.E.4
  • 5
    • 84877289895 scopus 로고    scopus 로고
    • Effect of long-detection interval vs standard-detection interval for implantable cardioverter-defibrillators on antitachycardia pacing and shock delivery. The ADVANCE III Randomized Clinical Trial
    • Gasparini M, Proclemer A, Klersy C, Kloppe A, Lunati M, Ferrer JBM, Hersi A, Gulaj M, Wijfels M, Santi E, Manotta L, Arenal A,: Effect of long-detection interval vs standard-detection interval for implantable cardioverter- defibrillators on antitachycardia pacing and shock delivery. The ADVANCE III Randomized Clinical Trial. JAMA 2013; 309: 1903-1911.
    • (2013) JAMA , vol.309 , pp. 1903-1911
    • Gasparini, M.1    Proclemer, A.2    Klersy, C.3    Kloppe, A.4    Lunati, M.5    Ferrer, J.B.M.6    Hersi, A.7    Gulaj, M.8    Wijfels, M.9    Santi, E.10    Manotta, L.11    Arenal, A.12
  • 6
    • 84891854367 scopus 로고    scopus 로고
    • Programming implantable cardioverter-defibrillators in patients with primary prevention indication to prolong time to first shock: Results from the PROVIDE study
    • Saeed M, Hanna I, Robotis D, Styperek R, Polosajian L, Khan A, Alonso J, Nabutovsky Y, Neason C,: Programming implantable cardioverter-defibrillators in patients with primary prevention indication to prolong time to first shock: Results from the PROVIDE study. J Cardiovasc Electrophysiol 2014; 25: 52-59.
    • (2014) J Cardiovasc Electrophysiol , vol.25 , pp. 52-59
    • Saeed, M.1    Hanna, I.2    Robotis, D.3    Styperek, R.4    Polosajian, L.5    Khan, A.6    Alonso, J.7    Nabutovsky, Y.8    Neason, C.9
  • 7
    • 84874478830 scopus 로고    scopus 로고
    • A randomized study of remote follow-up of implantable cardioverter defibrillators: Safety and efficacy report of the ECOST trial
    • for the ECOST trial Investigators
    • Guédon-Moreau L, Lacroix D, Sadoul N, Clémenty J, Kouakam C, Hermida JS, Aliot E, Boursier M, Bizeau O, Kacet S,; for the ECOST trial Investigators: A randomized study of remote follow-up of implantable cardioverter defibrillators: Safety and efficacy report of the ECOST trial. Eur Heart J 2013; 34: 605-614.
    • (2013) Eur Heart J , vol.34 , pp. 605-614
    • Guédon-Moreau, L.1    Lacroix, D.2    Sadoul, N.3    Clémenty, J.4    Kouakam, C.5    Hermida, J.S.6    Aliot, E.7    Boursier, M.8    Bizeau, O.9    Kacet, S.10
  • 9
    • 33846289600 scopus 로고    scopus 로고
    • Remote, wireless, ambulatory monitoring of implantable pacemakers, cardioverter defibrillators, and cardiac resynchronization therapy systems: Analysis of a worldwide database
    • Lazarus A,: Remote, wireless, ambulatory monitoring of implantable pacemakers, cardioverter defibrillators, and cardiac resynchronization therapy systems: Analysis of a worldwide database. Pacing Clin Electrophysiol 2007; 30: S2-S12.
    • (2007) Pacing Clin Electrophysiol , vol.30
    • Lazarus, A.1
  • 10
    • 77955171126 scopus 로고    scopus 로고
    • Efficacy and safety of automatic remote monitoring for implantable cardioverter-defibrillator follow-up: The Lumos-T Safely Reduces Routine Office Device Follow-Up (TRUST) trial
    • TRUST Investigators
    • Varma N, Epstein AE, Irimpen A, Schweikert R, Love C,; TRUST Investigators: Efficacy and safety of automatic remote monitoring for implantable cardioverter-defibrillator follow-up: The Lumos-T Safely Reduces Routine Office Device Follow-Up (TRUST) trial. Circulation 2010; 122: 325-332.
    • (2010) Circulation , vol.122 , pp. 325-332
    • Varma, N.1    Epstein, A.E.2    Irimpen, A.3    Schweikert, R.4    Love, C.5
  • 12
    • 84886409725 scopus 로고    scopus 로고
    • Survival after shock therapy in implantable cardioverter-defibrillator and cardiac resynchronization therapy-defibrillator recipients according to rhythm shocked. The ALTITUDE survival by rhythm study
    • Powell BD, Saxon LA, Boehmer JP, Day JD, Roosevelt Gilliam III F, Heidenreich PA, Jones PW, Rousseau MJ, Hayes DL,: Survival after shock therapy in implantable cardioverter-defibrillator and cardiac resynchronization therapy-defibrillator recipients according to rhythm shocked. The ALTITUDE survival by rhythm study. J Am Coll Cardiol 2013; 62: 1674-1679.
    • (2013) J Am Coll Cardiol , vol.62 , pp. 1674-1679
    • Powell, B.D.1    Saxon, L.A.2    Boehmer, J.P.3    Day, J.D.4    Roosevelt Gilliam III, F.5    Heidenreich, P.A.6    Jones, P.W.7    Rousseau, M.J.8    Hayes, D.L.9
  • 13
    • 84863728798 scopus 로고    scopus 로고
    • Comparison between atrial fibrillation-triggered Implantable Cardioverter-Defibrillator (ICD) shocks and inappropriate shocks caused by lead failure: Different impact on prognosis in clinical practice
    • Kleemann T, Hochadel M, Strauss M, Skarlos A, Seidl K, Zahn R,: Comparison between atrial fibrillation-triggered Implantable Cardioverter-Defibrillator (ICD) shocks and inappropriate shocks caused by lead failure: Different impact on prognosis in clinical practice. J Cardiovasc Electrophysiol 2012; 23: 735-740.
    • (2012) J Cardiovasc Electrophysiol , vol.23 , pp. 735-740
    • Kleemann, T.1    Hochadel, M.2    Strauss, M.3    Skarlos, A.4    Seidl, K.5    Zahn, R.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.