Development and application of a suite of 4-D virtual breast phantoms for optimization and evaluation of breast imaging systems

Author keywords

Breast phantom; contrast enhanced breast imaging; four dimensional (4 D) breast phantom; system evaluation; system optimization; virtual breast phantom

Indexed keywords

COMPUTER SIMULATION; IMAGING SYSTEMS; KINETICS; MAMMOGRAPHY; TISSUE;

EID: 84903761758     PISSN: 02780062     EISSN: 1558254X     Source Type: Journal    
DOI: 10.1109/TMI.2014.2312733     Document Type: Article
Times cited : (35)

References (26)
  • 1
    • 56449100677 scopus 로고    scopus 로고
    • Guideline implementation for breast healthcare in low-income and middle-income countries
    • B. O. Anderson, C. H. Yip, and R. A. Smith, "Guideline implementation for breast healthcare in low-income and middle-income countries," Cancer, vol. 113, pp. 2221-2243, 2008.
    • (2008) Cancer , vol.113 , pp. 2221-2243
    • Anderson, B.O.1    Yip, C.H.2    Smith, R.A.3
  • 4
    • 0030711575 scopus 로고    scopus 로고
    • Digital tomosyn-thesis in breast imaging
    • L. T. Niklason, B. T. Christian, and L. E. Niklason, "Digital tomosyn-thesis in breast imaging," Radiology, vol. 205, pp. 399-406, 1997.
    • (1997) Radiology , vol.205 , pp. 399-406
    • Niklason, L.T.1    Christian, B.T.2    Niklason, L.E.3
  • 5
    • 33947226238 scopus 로고    scopus 로고
    • Evaluation of tumor angiogenesis of breast carcinoma using contrast-enhanced digital mammography
    • C. Dromain, C. Balleyguier, S. Muller, M.-C Mathieu, F. Rochard, P. Opolon, and R. Sigal, "Evaluation of tumor angiogenesis of breast carcinoma using contrast-enhanced digital mammography," Am. J. Roentgenol., vol. 187, no. 5, pp. 528-537, 2006.
    • (2006) Am. J. Roentgenol. , vol.187 , Issue.5 , pp. 528-537
    • Dromain, C.1    Balleyguier, C.2    Muller, S.3    Mathieu, M.-C.4    Rochard, F.5    Opolon, P.6    Sigal, R.7
  • 6
    • 50949101776 scopus 로고    scopus 로고
    • Temporal subtraction versus dual-energy contrast-enhanced digital breast tomosynthesis: A pilot study
    • Berlin, Germany: Springer Lecture Notes Comput. Sci
    • A. K. Carton, J. A. Currivan, E. Conant, and A. D. A. Maidment, "Temporal subtraction versus dual-energy contrast-enhanced digital breast tomosynthesis: A pilot study," in Digital Mammography. Berlin, Germany: Springer, 2008, vol. 5116, Lecture Notes Comput. Sci., pp. 166-173.
    • (2008) Digital Mammography , vol.5116 , pp. 166-173
    • Carton, A.K.1    Currivan, J.A.2    Conant, E.3    Maidment, A.D.A.4
  • 7
    • 0032958860 scopus 로고    scopus 로고
    • Dynamic breast MR imaging: Are signal intensity time course data useful for differential diagnosis of enhancing lesions?
    • C. K. Kuhl, P. Mielcareck, and S. Klaschik, "Dynamic breast MR imaging: Are signal intensity time course data useful for differential diagnosis of enhancing lesions," Radiology, vol. 211, pp. 101-110, 1999. (Pubitemid 29161739)
    • (1999) Radiology , vol.211 , Issue.1 , pp. 101-110
    • Kuhl, C.K.1    Mielcareck, P.2    Klaschik, S.3    Leutner, C.4    Wardelmann, E.5    Gieseke, J.6    Schild, H.H.7
  • 8
    • 84878731415 scopus 로고    scopus 로고
    • Correlation of contrast agent kinetics between iodinated contrast-enhanced spectral tomosynthesis and gadolinium-enhanced MRI of breast lesions
    • V. Froeling, F. Diekmann, D. M. Renz, E. M. Fallenberg, I. G. Steffen, S. Diekmann, R. Lawaczeck, and F. F. Schmitzburger, "Correlation of contrast agent kinetics between iodinated contrast-enhanced spectral tomosynthesis and gadolinium-enhanced MRI of breast lesions," Eur. Radiol., vol. 23, no. 6, pp. 1528-1536, 2013.
    • (2013) Eur. Radiol. , vol.23 , Issue.6 , pp. 1528-1536
    • Froeling, V.1    Diekmann, F.2    Renz, D.M.3    Fallenberg, E.M.4    Steffen, I.G.5    Diekmann, S.6    Lawaczeck, R.7    Schmitzburger, F.F.8
  • 11
    • 33846186878 scopus 로고    scopus 로고
    • Initial clinical experience with contrast-enhanced digital breast tomosynthesis
    • DOI 10.1016/j.acra.2006.10.022, PII S1076633206006647
    • S. Chen, A-K. Carton, A. Michael, E. F. Conant, M. D. Schnall, and A. D. A. Maidment, "Initial clinical experience with contrast-enhanced digital breast tomosynthesis," Acad. Radiol., vol. 14, no. 2, pp. 229-238, 2007. (Pubitemid 46108599)
    • (2007) Academic Radiology , vol.14 , Issue.2 , pp. 229-238
    • Chen, S.C.1    Carton, A.-K.2    Albert, M.3    Conant, E.F.4    Schnall, M.D.5    Maidment, A.D.A.6
  • 13
    • 80053211249 scopus 로고    scopus 로고
    • Dual-energy contrast-enhanced breast tomosynthesis: Optimization of beam quality for dose and image quality
    • E. Samei and R. S. Saunders, "Dual-energy contrast-enhanced breast tomosynthesis: Optimization of beam quality for dose and image quality," Phys. Med. Biol., vol. 56, no. 19, pp. 6359-6378, 2011.
    • (2011) Phys. Med. Biol. , vol.56 , Issue.19 , pp. 6359-6378
    • Samei, E.1    Saunders, R.S.2
  • 14
    • 67649592452 scopus 로고    scopus 로고
    • Methodology for generating a 3-D computerized breast phantom from empirical data
    • C. M. Li, W. P. Segars, J. T. Dobbins III, G. D. Tourassi, and J. M. Boone, "Methodology for generating a 3-D computerized breast phantom from empirical data," Med. Phys., vol. 36, no. 7, pp. 3122-3131, 2009.
    • (2009) Med. Phys. , vol.36 , Issue.7 , pp. 3122-3131
    • Li, C.M.1    Segars, W.P.2    Dobbins III, J.T.3    Tourassi, G.D.4    Boone, J.M.5
  • 15
    • 80053605013 scopus 로고    scopus 로고
    • An analysis of the mechanical parameters used for finite element compression of a high-resolution 3-D breast phantom
    • C. M. L. Hsu, M. L. Palmeri, W. P. Segars, J. T. Dobbins III, and A. I. Veress, "An analysis of the mechanical parameters used for finite element compression of a high-resolution 3-D breast phantom," Med. Phys., vol. 38, no. 10, pp. 5756-5770, 2011.
    • (2011) Med. Phys. , vol.38 , Issue.10 , pp. 5756-5770
    • Hsu, C.M.L.1    Palmeri, M.L.2    Segars, W.P.3    Dobbins III, J.T.4    Veress, A.I.5
  • 16
    • 84876173466 scopus 로고    scopus 로고
    • Generation of a suite of 3-D computer-generated breast phantoms from a limited set of human subject data
    • C. M. L. Hsu, M. L. Palmeri, W. P. Segars, A. I. Veress, and J. T. Dobbins III, "Generation of a suite of 3-D computer-generated breast phantoms from a limited set of human subject data," Med. Phys., vol. 40, no. 4, pp. 043703-043703, 2013.
    • (2013) Med. Phys. , vol.40 , Issue.4 , pp. 043703-043703
    • Hsu, C.M.L.1    Palmeri, M.L.2    Segars, W.P.3    Veress, A.I.4    Dobbins III, J.T.5
  • 18
    • 84864847797 scopus 로고    scopus 로고
    • Application of a dynamic 4-D anthropomorphic breast phantom in contrast-based imaging system optimization: Dual-energy or temporal subtraction?
    • Berlin, Germany: Springer Lecture Notes Comput. Sci
    • N. Kiarashi, S. V. Ghate, J. Y. Lo, L. W. Nolte, and E. Samei, "Application of a dynamic 4-D anthropomorphic breast phantom in contrast-based imaging system optimization: dual-energy or temporal subtraction?," in Digital Mammography. Berlin, Germany: Springer, 2012, vol. 7361, Lecture Notes Comput. Sci., pp. 658-665.
    • (2012) Digital Mammography , vol.7361 , pp. 658-665
    • Kiarashi, N.1    Ghate, S.V.2    Lo, J.Y.3    Nolte, L.W.4    Samei, E.5
  • 19
    • 0344958761 scopus 로고    scopus 로고
    • Delivery of diagnostic agents in computed tomography
    • DOI 10.1016/S0169-409X(98)00105-7, PII S0169409X98001057
    • W. Krause, "Delivery of diagnostic agents in computed tomography," Adv. Drug Delivery Rev., vol. 37, no. 1-3, pp. 159-173, 1999. (Pubitemid 29164506)
    • (1999) Advanced Drug Delivery Reviews , vol.37 , Issue.1-3 , pp. 159-173
    • Krause, W.1
  • 20
    • 0028963102 scopus 로고
    • Quantitative analysis of dynamic Gd-DTPa enhancement in breast tumors using a permeability model
    • P. S. Tofts, B. Berkowitz, and M. D. Schnall, "Quantitative analysis of dynamic Gd-DTPa enhancement in breast tumors using a permeability model," Mag. Res. Med., vol. 33, no. 4, pp. 564-568, 1995.
    • (1995) Mag. Res. Med. , vol.33 , Issue.4 , pp. 564-568
    • Tofts, P.S.1    Berkowitz, B.2    Schnall, M.D.3
  • 21
    • 0032900885 scopus 로고    scopus 로고
    • Regional blood flow, capillary permeability, and compartmental volumes: Measurement with dynamic CT - Initial experience
    • G. Brix, M. L. Bahner, U. Hoffmann, A. Horvath, and W. Schreiber, "Regional blood flow, capillary permeability, and compartmental volumes: Measurement with dynamic CT-Initial experience," Radiology, vol. 210, no. 1, pp. 269-76, 1999. (Pubitemid 29004315)
    • (1999) Radiology , vol.210 , Issue.1 , pp. 269-276
    • Brix, G.1    Bahner, M.L.2    Hoffman, U.3    Horvath, A.4    Schreiber, W.5
  • 22
    • 0036237992 scopus 로고    scopus 로고
    • Breast cancer: Regional blood flow and blood volume measured with magnetic susceptibility-based MR imaging - Initial results
    • J-P. Delille, P. J. Slanetz, E. D. Yeh, D. B. Kopans, and L. Garrido, "Breast cancer: Regional blood flow and blood volume measured with magnetic susceptibility-based MR imaging initial results," Radiology, vol. 223, no. 2, pp. 558-565, 2002. (Pubitemid 34454343)
    • (2002) Radiology , vol.223 , Issue.2 , pp. 558-565
    • Delille, J.-P.1    Slanetz, P.J.2    Yeh, E.D.3    Kopans, D.B.4    Garrido, L.5
  • 23
    • 79953304227 scopus 로고    scopus 로고
    • An anthropomorphic breast model for breast imaging simulation and optimization
    • B. Chen, J. Shorey, R. S. Saunders, S. Richard, J. Thompson, L. W. Nolte, and E. Samei, "An anthropomorphic breast model for breast imaging simulation and optimization," Acad. Radiol., vol. 18, no. 5, pp. 536-546, 2011.
    • (2011) Acad. Radiol. , vol.18 , Issue.5 , pp. 536-546
    • Chen, B.1    Shorey, J.2    Saunders, R.S.3    Richard, S.4    Thompson, J.5    Nolte, L.W.6    Samei, E.7
  • 25
    • 4644334876 scopus 로고    scopus 로고
    • A comparison of reconstruction algorithms for breast tomosynthesis
    • DOI 10.1118/1.1786692
    • T. Wu, R. H. Moore, E. A. Rafferty, and D. B. Kopans, "A comparison of reconstruction algorithms for breast tomosynthesis," Med. Phys., vol. 31, no. 9, pp. 2636-2647, 2004. (Pubitemid 39287881)
    • (2004) Medical Physics , vol.31 , Issue.9 , pp. 2636-2647
    • Wu, T.1    Moore, R.H.2    Rafferty, E.A.3    Kopans, D.B.4
  • 26
    • 0037342846 scopus 로고    scopus 로고
    • Experimental investigation of the dose and image quality characteristics of a digital mammography imaging system
    • DOI 10.1118/1.1543572
    • W. Huda, A. M. Sajewicz, K. M. Ogden, and D. R. Dance, "Experimental investigation of the dose and image quality characteristics of a digital mammography imaging system," Med. Phys., vol. 30, no. 3, pp. 442-448, 2003. (Pubitemid 36337111)
    • (2003) Medical Physics , vol.30 , Issue.3 , pp. 442-448
    • Huda, W.1    Sajewicz, A.M.2    Ogden, K.M.3    Dance, D.R.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.