메뉴 건너뛰기




Volumn 83, Issue 988, 2010, Pages 344-350

Dual-energy contrast-enhanced digital breast tomosynthesis - A feasibility study

Author keywords

[No Author keywords available]

Indexed keywords

IODINATED CONTRAST MEDIUM; IODIXANOL; SODIUM CHLORIDE;

EID: 77950555103     PISSN: 00071285     EISSN: None     Source Type: Journal    
DOI: 10.1259/bjr/80279516     Document Type: Article
Times cited : (71)

References (30)
  • 3
    • 0032958860 scopus 로고    scopus 로고
    • Dynamic breast MR imaging: Are signal intensity time course data useful for differential diagnosis of enhancing lesions?
    • Kuhl CK, Mielcareck P, Klaschik S, Leutner C, Wardelmann E, Gieseke J, et al. Dynamic breast MR imaging: Are signal intensity time course data useful for differential diagnosis of enhancing lesions? Radiology 1999;211:101-110
    • (1999) Radiology , vol.211 , pp. 101-110
    • Kuhl, C.K.1    Mielcareck, P.2    Klaschik, S.3    Leutner, C.4    Wardelmann, E.5    Gieseke, J.6
  • 4
    • 0034860249 scopus 로고    scopus 로고
    • Vascularity assessment of breast lesions with gadolinium-enhanced MR imaging
    • Hylton NM. Vascularity assessment of breast lesions with gadolinium-enhanced MR imaging. MRI Clinics of North America 2001;9:321-331 (Pubitemid 32816430)
    • (2001) Magnetic Resonance Imaging Clinics of North America , vol.9 , Issue.2 , pp. 321-331
    • Hylton, N.M.1
  • 5
    • 0036288136 scopus 로고    scopus 로고
    • Optimal post-contrast timing of breast MR image acquisition for architectural feature analysis
    • DOI 10.1002/jmri.10135
    • Nunes LW, Englander SA, Charafeddine R, Schnall MD. Optimal post-contrast timing of breast MR image acquisition for architectural feature analysis. J Magn Reson Imaging 2002;16:42-50. (Pubitemid 34700841)
    • (2002) Journal of Magnetic Resonance Imaging , vol.16 , Issue.1 , pp. 42-50
    • Nunes, L.W.1    Englander, S.A.2    Charafeddine, R.3    Schnall, M.D.4
  • 6
    • 23844474417 scopus 로고    scopus 로고
    • Dynamic bilateral contrast-enhanced MR imaging of the breast: Trade-off between spatial and temporal resolution
    • DOI 10.1148/radiol.2363040811
    • Kuhl CK, Schild HH, Morakkabati N. Dynamic bilateral contrast-enhanced MR imaging of the breast: trade-off between spatial and temporal resolution. Radiology 2005;2005:789-800. (Pubitemid 41170839)
    • (2005) Radiology , vol.236 , Issue.3 , pp. 789-800
    • Kuhl, C.K.1    Schild, H.H.2    Morakkabati, N.3
  • 8
    • 33846186878 scopus 로고    scopus 로고
    • Initial Clinical Experience with Contrast-Enhanced Digital Breast Tomosynthesis
    • DOI 10.1016/j.acra.2006.10.022, PII S1076633206006647
    • Chen SC, Carton A-K, Albert M, Conant EF, Schnall MD, Maidment ADA. Initial clinical experience with contrast-enhanced digital breast tomosynthesis. Academic Radiology 2007;14:229-238 (Pubitemid 46108599)
    • (2007) Academic Radiology , vol.14 , Issue.2 , pp. 229-238
    • Chen, S.C.1    Carton, A.-K.2    Albert, M.3    Conant, E.F.4    Schnall, M.D.5    Maidment, A.D.A.6
  • 13
    • 0141629469 scopus 로고    scopus 로고
    • Dual-energy contrast-enhanced digital subtraction mammography: Feasibility
    • DOI 10.1148/radiol.2291021276
    • Lewin JM, Isaacs PK, Vance V, Larke FJ. Dual-energy contrast-enhanced digital subtraction mammography: Feasibility. Radiology 2003;264:261-268 (Pubitemid 37152134)
    • (2003) Radiology , vol.229 , Issue.1 , pp. 261-268
    • Lewin, J.M.1    Isaacs, P.K.2    Vance, V.3    Larke, F.J.4
  • 14
    • 33745352483 scopus 로고    scopus 로고
    • Dual-energy imaging using a digital scanned multi-slit system for mammography: Evaluation of a differential beam filtering technique
    • Flynn MJ, Hsieh J, editors San Diego, CA: SPIE, 614220-1-7.
    • Bornefalk H, Hemmendorff M, Hjarm T. Dual-energy imaging using a digital scanned multi-slit system for mammography: evaluation of a differential beam filtering technique. In: Flynn MJ, Hsieh J, editors. Medical Imaging 2006: Physics of Medical Imaging. San Diego, CA: SPIE, 2006: 614220-1-7.
    • (2006) Medical Imaging 2006: Physics of Medical Imaging
    • Bornefalk, H.1    Hemmendorff, M.2    Hjarm, T.3
  • 15
    • 35148829602 scopus 로고    scopus 로고
    • Dual-energy contrast enhanced digital mammography using a new approach for breast tissue canceling
    • Hsieh J, Flynn MJ, editors San Diego, CA: SPIE, 65102H-1-12.
    • Puong S, Bouchevreau X, Patoureaux F, Iordache R, Muller S. Dual-energy contrast enhanced digital mammography using a new approach for breast tissue canceling. In: Hsieh J, Flynn MJ, editors. Medical Imaging 2007: Physics of Medical Imaging. San Diego, CA: SPIE, 2007 65102H-1-12.
    • (2007) Medical Imaging 2007: Physics of Medical Imaging
    • Puong, S.1    Bouchevreau, X.2    Patoureaux, F.3    Iordache, R.4    Muller, S.5
  • 16
    • 35148856835 scopus 로고    scopus 로고
    • Dual-energy subtraction for contrast enhanced digital breast tomosynthesis
    • Hsieh J, Flynn MJ, editors San Diego, CA: SPIE, 651007-1-12.
    • Carton AK, Lindman K, Ullberg CK, Francke T. Dual-energy subtraction for contrast enhanced digital breast tomosynthesis. In: Hsieh J, Flynn MJ, editors. Physics of Medical Imaging; 2007. San Diego, CA: SPIE, 2007 651007-1-12.
    • (2007) Physics of Medical Imaging; 2007
    • Carton, A.K.1    Lindman, K.2    Ullberg, C.K.3    Francke, T.4
  • 18
    • 57049123860 scopus 로고    scopus 로고
    • United States radiological health activities: Inspection results of mammography facilities
    • Spelic DC, Kaczmarek RV, Hilohi M, Belella S. United States radiological health activities: inspection results of mammography facilities. Biomed Imaging Interv J 2007;3. www.bjr.org/2007/2/e35
    • (2007) Biomed Imaging Interv J , vol.3
    • Spelic, D.C.1    Kaczmarek, R.V.2    Hilohi, M.3    Belella, S.4
  • 20
    • 0035999415 scopus 로고    scopus 로고
    • Normalized glandular dose (DgN) coefficients for arbitrary x-ray spectra in mammography: Computer-fit values of Monte Carlo derived data
    • Boone JM. Normalized glandular dose (DgN) coefficients for arbitrary x-ray spectra in mammography: computer-fit values of Monte Carlo derived data. Med Phys 2002;29:869-875
    • (2002) Med Phys , vol.29 , pp. 869-875
    • Boone, J.M.1
  • 21
    • 0031466296 scopus 로고    scopus 로고
    • Molybdenum, rhodium, and tungsten anode spectral models using interpolating polynomials with application to mammography
    • Boone JM, Fewell TR, Jennings RJ. Molybdenum, rhodium, and tungsten anode spectral models using interpolating polynomials with application to mammography. Med Phys 1997;24:1863-1874
    • (1997) Med Phys , vol.24 , pp. 1863-1874
    • Boone, J.M.1    Fewell, T.R.2    Jennings, R.J.3
  • 22
    • 77950592319 scopus 로고    scopus 로고
    • Available at: Assessed 27 May
    • Total variation denoising. Available at: http://www.math.ucla.edu/, gilboa/PDE-filt/tv-denoising.html [Assessed 27 May 2009].
    • (2009) Total Variation Denoising
  • 23
    • 0037322222 scopus 로고    scopus 로고
    • Dobbins JT 3rd. Quantitative evaluation of noise reduction strategies in dual-energy imaging
    • Warp RJ, Dobbins JT 3rd. Quantitative evaluation of noise reduction strategies in dual-energy imaging. Med Phys 2003;30:190-198
    • (2003) Med Phys , vol.30 , pp. 190-198
    • Warp, R.J.1
  • 24
    • 0024070365 scopus 로고
    • An algorithm for noise suppression in dual energy CT material density images
    • Kalender WA, Klotz E, Kostaridou L. An algorithm for noise suppression in dual energy CT material density images. IEEE Trans Med Imaging 1988;7:218-224
    • (1988) IEEE Trans Med Imaging , vol.7 , pp. 218-224
    • Kalender, W.A.1    Klotz, E.2    Kostaridou, L.3
  • 25
    • 0024418565 scopus 로고
    • A correlated noise reduction algorithm for dual-energy digital substraction angiography
    • DOI 10.1118/1.596436
    • McCollough CH, Van Lysel MS, Peppler WW. A correlated noise reduction algorithm for dual-energy digital subtraction angiography. Med Phys 1989;16:873-880 (Pubitemid 19279812)
    • (1989) Medical Physics , vol.16 , Issue.6 , pp. 873-880
    • McCollough, C.H.1    Van Lysel, M.S.2    Peppler, W.W.3    Mistretta, C.A.4
  • 26
    • 4644334876 scopus 로고    scopus 로고
    • A comparison of reconstruction algorithms for breast tomosynthesis
    • DOI 10.1118/1.1786692
    • Wu T, Moore RH, Rafferty EA, Kopans DA. A comparison of reconstruction algorithms for breast tomosynthesis. Med Phys 2004;31:2636-2647 (Pubitemid 39287881)
    • (2004) Medical Physics , vol.31 , Issue.9 , pp. 2636-2647
    • Wu, T.1    Moore, R.H.2    Rafferty, E.A.3    Kopans, D.B.4
  • 27
    • 84859210115 scopus 로고    scopus 로고
    • Available at: Accessed 27 May
    • Medical Imaging Resource Center. Available at: http://www.rsna.org/mirc/ [Accessed 27 May 2009].
    • (2009) Medical Imaging Resource Center
  • 28
    • 17844408736 scopus 로고    scopus 로고
    • Assessment of Display Performance for Medical Imaging Systems
    • Report of the American Association of Physicists in Medicine (AAPM) Task Group 18
    • Samei E, Badano A, Chakraborty D, Compton K, Cornelius C, Corrigan K, et al. Assessment of Display Performance for Medical Imaging Systems, Report of the American Association of Physicists in Medicine (AAPM) Task Group 18. Med Phys 2005;32:1205-1225.
    • (2005) Med Phys , vol.32 , pp. 1205-1225
    • Samei, E.1    Badano, A.2    Chakraborty, D.3    Compton, K.4    Cornelius, C.5    Corrigan, K.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.