메뉴 건너뛰기




Volumn 46, Issue 2, 2014, Pages 179-185

Development of ventricular assist devices in china: Present status, opportunities and challenges

Author keywords

Axial pump; Centrifugal pump; Intra aorta pump; Ventricular assist devices

Indexed keywords

ARTICLE; ASSISTED CIRCULATION; BIOCOMPATIBILITY; BLOOD CLOTTING; BLOOD PUMP; CENTRIFUGAL PUMP; CHINA; CLINICAL PRACTICE; CLINICAL RESEARCH; EQUIPMENT DESIGN; EXTRACORPOREAL OXYGENATION; HEALTH CARE COST; HEART FAILURE; HEART LEFT VENTRICLE; HEART TRANSPLANTATION; HUMAN; IMPELLER; IMPLANTABLE PUMP; NONHUMAN; PRIORITY JOURNAL; VENTRICULAR ASSIST DEVICE; HEART ASSIST DEVICE;

EID: 84901912640     PISSN: 10107940     EISSN: 1873734X     Source Type: Journal    
DOI: 10.1093/ejcts/ezu020     Document Type: Article
Times cited : (9)

References (30)
  • 1
    • 33745492985 scopus 로고    scopus 로고
    • The design conception and realization of pulsatile ventricular assist devices: from spiralvortex pump to Luo-Ye pump
    • Ye CX, Uumezu M, Nakamura T, Luo ZX, Fan RX, Xiao XJ. The design conception and realization of pulsatile ventricular assist devices: from spiralvortex pump to Luo-Ye pump. Chin J Clin Thorac Cardiovasc Surg 2002;9:35-40.
    • (2002) Chin J Clin Thorac Cardiovasc Surg , vol.9 , pp. 35-40
    • Ye, C.X.1    Uumezu, M.2    Nakamura, T.3    Luo, Z.X.4    Fan, R.X.5    Xiao, X.J.6
  • 3
    • 33745485888 scopus 로고    scopus 로고
    • The clinical trial of pneumatic pump (Luo-Yepump) as left ventricular assist device
    • Xiao XJ, Fan RX, Cheng AH. The clinical trial of pneumatic pump (Luo-Yepump) as left ventricular assist device. South China J Cardiovasc Dis 2002;8:43-5.
    • (2002) South China J Cardiovasc Dis , vol.8 , pp. 43-45
    • Xiao, X.J.1    Fan, R.X.2    Cheng, A.H.3
  • 5
    • 84905459344 scopus 로고    scopus 로고
    • The comparison of animal experiment between Luo-Ye pumpand Excor pump
    • Wu YH. The comparison of animal experiment between Luo-Ye pumpand Excor pump. Chin J Pathophysiol 2010;26:1995.
    • (2010) Chin J Pathophysiol , vol.26 , pp. 1995
    • Wu, Y.H.1
  • 6
    • 84905491295 scopus 로고    scopus 로고
    • Experimental research onendothelialization of diaphragm-pneumatic left ventricular assistpump-Luo-Ye pump
    • Li H, Huang HL, Xiao XJ, Lin QX, Cheng AH. Experimental research onendothelialization of diaphragm-pneumatic left ventricular assistpump-Luo-Ye pump. Chin J ECC 2011;9:111-4.
    • (2011) Chin J ECC , vol.9 , pp. 111-114
    • Li, H.1    Huang, H.L.2    Xiao, X.J.3    Lin, Q.X.4    Cheng, A.H.5
  • 7
    • 41349095070 scopus 로고    scopus 로고
    • Design optimizationof an axial blood pump with computational fluid dynamics
    • Zhang Y, Zhan Z, Gui XM, Sun HS, Zhang H, Zheng Z et al. Design optimizationof an axial blood pump with computational fluid dynamics.ASAIO J 2008;54:150-5.
    • (2008) A.S.A.I.O J , vol.54 , pp. 150-155
    • Zhang, Y.1    Zhan, Z.2    Gui, X.M.3    Sun, H.S.4    Zhang, H.5    Zheng, Z.6
  • 9
    • 34247281604 scopus 로고    scopus 로고
    • Digital simulation to thedevelopment of axial blood pump for artificial heart
    • Zhang Y, Xue S, Gui XM, Hu SS, Sun HS, Zhu XD. Digital simulation to thedevelopment of axial blood pump for artificial heart. Chin J Biomed Eng2007;26:35-41.
    • (2007) Chin J Biomed Eng , vol.26 , pp. 35-41
    • Zhang, Y.1    Xue, S.2    Gui, X.M.3    Hu, S.S.4    Sun, H.S.5    Zhu, X.D.6
  • 10
    • 59549101926 scopus 로고    scopus 로고
    • Design and performance testing of an axial flow ventricular assist device developed at theFu Wai Hospital in Beijing
    • Zhang Y, Hu SS, Zhou JY, Sun HS, Zhang H, Zheng Z et al. Design and performance testing of an axial flow ventricular assist device developed at theFu Wai Hospital in Beijing. Int J Artif Organ 2008;31:983-7.
    • (2008) Int J Artif Organ , vol.31 , pp. 983-987
    • Zhang, Y.1    Hu, S.S.2    Zhou, J.Y.3    Sun, H.S.4    Zhang, H.5    Zheng, Z.6
  • 11
    • 84905500901 scopus 로고    scopus 로고
    • Study of the temperature increase in a new heart assist device ventricular apex axial pump
    • Li GR, Zhu XD, Peng YY, Chen HF, Tian BS. Study of the temperature increase in a new heart assist device ventricular apex axial pump. ChinaMedal Dev Inform 2007;13:25-8.
    • (2007) ChinaMedal Dev Inform , vol.13 , pp. 25-28
    • Li, G.R.1    Zhu, X.D.2    Peng, Y.Y.3    Chen, H.F.4    Tian, B.S.5
  • 12
    • 84905496334 scopus 로고    scopus 로고
    • Study of anatomic fit of microapex pump and surgical injure in animal implantation experiments
    • Li GR, Zhu XD, Hao ZC, Tian BS, Chen HF. Study of anatomic fit of microapex pump and surgical injure in animal implantation experiments. ChinMed Equip J 2010;31:20-2.
    • (2010) ChinMed Equip J , vol.31 , pp. 20-22
    • Li, G.R.1    Zhu, X.D.2    Hao, Z.C.3    Tian, B.S.4    Chen, H.F.5
  • 13
    • 78349298282 scopus 로고    scopus 로고
    • Modeling and identification of an intra-aorta pump
    • Chang Y, Gao B. Modeling and identification of an intra-aorta pump. Am Soc Artif Intern Organs J 2010;56:504-9.
    • (2010) Am Soc Artif Intern Organs J , vol.56 , pp. 504-509
    • Chang, Y.1    Gao, B.2
  • 14
    • 84865866441 scopus 로고    scopus 로고
    • Hemodynamic simulation study of a novel intra-aorta left ventricular assist device
    • Xuan YJ, Chang Y, Gu KY, Gao B. Hemodynamic simulation study of a novel intra-aorta left ventricular assist device. Am Soc Artif Intern Organs J 2012;58:462-9.
    • (2012) Am Soc Artif Intern Organs J , vol.58 , pp. 462-469
    • Xuan, Y.J.1    Chang, Y.2    Gu, K.Y.3    Gao, B.4
  • 15
    • 84865863174 scopus 로고    scopus 로고
    • Computational analysis of the effect of the control model of intra aorta pump on ventricular unloading and vessel response
    • Gu KY, Chang Y, Gao B, Liu YJ. Computational analysis of the effect of the control model of intra aorta pump on ventricular unloading and vessel response. Am Soc Artif Intern Organs J 2012;58:455-61.
    • (2012) Am Soc Artif Intern Organs J , vol.58 , pp. 455-461
    • Gu, K.Y.1    Chang, Y.2    Gao, B.3    Liu, Y.J.4
  • 16
    • 84873322638 scopus 로고    scopus 로고
    • The hemodynamic effect of the support mode for the intra-aorta pump on the cardiovascular system
    • Gao B, Chang Y, Xuan YJ, Zeng Y, Liu YJ. The hemodynamic effect of the support mode for the intra-aorta pump on the cardiovascular system. Artif Organs 2013;37:157-65.
    • (2013) Artif Organs , vol.37 , pp. 157-165
    • Gao, B.1    Chang, Y.2    Xuan, Y.J.3    Zeng, Y.4    Liu, Y.J.5
  • 17
    • 78349249766 scopus 로고    scopus 로고
    • A global sliding mode controller design for an intra-aorta pump
    • Chang Y, Gao B. A global sliding mode controller design for an intra-aorta pump. Am Soc Artif Intern Organs J 2010;56:510-6.
    • (2010) Am Soc Artif Intern Organs J , vol.56 , pp. 510-516
    • Chang, Y.1    Gao, B.2
  • 18
    • 80052493160 scopus 로고    scopus 로고
    • A blood assist index control by intra-aorta pump: a control strategy for ventricular recovery
    • Gao B, Gu KY, Zeng Y, Liu YJ, Chang Y. A blood assist index control by intra-aorta pump: a control strategy for ventricular recovery. Am Soc Artif Intern Organs J 2011;57:358-62.
    • (2011) Am Soc Artif Intern Organs J , vol.57 , pp. 358-362
    • Gao, B.1    Gu, K.Y.2    Zeng, Y.3    Liu, Y.J.4    Chang, Y.5
  • 19
    • 84863517395 scopus 로고    scopus 로고
    • A pulsatile control algorithm of continuous-flow pump for heart recovery
    • Gao B, Chang Y, Gu KY, Zeng Y, Liu YJ. A pulsatile control algorithm of continuous-flow pump for heart recovery. Am Soc Artif Intern Organs J 2012;58:343-52.
    • (2012) Am Soc Artif Intern Organs J , vol.58 , pp. 343-352
    • Gao, B.1    Chang, Y.2    Gu, K.Y.3    Zeng, Y.4    Liu, Y.J.5
  • 20
    • 84858009038 scopus 로고    scopus 로고
    • An anti-suction control for an intra-aorta pump using blood assistant index: a numerical simulation
    • Gao B, Gu KY, Zeng Y, Chang Y. An anti-suction control for an intra-aorta pump using blood assistant index: a numerical simulation. Artif Organs 2012;36:275-90.
    • (2012) Artif Organs , vol.36 , pp. 275-290
    • Gao, B.1    Gu, K.Y.2    Zeng, Y.3    Chang, Y.4
  • 21
    • 84870771124 scopus 로고    scopus 로고
    • Physiological controller of an intra-aorta pump based on Baroreflex sensitivity
    • Gao B, Chang Y, Gu KY, Zeng Y, Liu YJ. Physiological controller of an intra-aorta pump based on Baroreflex sensitivity. Artif Organs 2012;36: 1015-25.
    • (2012) Artif Organs , vol.36 , pp. 1015-1025
    • Gao, B.1    Chang, Y.2    Gu, K.Y.3    Zeng, Y.4    Liu, Y.J.5
  • 22
    • 84863015580 scopus 로고    scopus 로고
    • Thermal analysis of a new implantable magnetic levitation blood pump
    • Guo LH, Zhang JM, Zhao L, Liu XC. Thermal analysis of a new implantable magnetic levitation blood pump. J Biomed Eng Res 2010;29:152-5.
    • (2010) J Biomed Eng Res , vol.29 , pp. 152-155
    • Guo, L.H.1    Zhang, J.M.2    Zhao, L.3    Liu, X.C.4
  • 23
    • 84869796142 scopus 로고    scopus 로고
    • In vivo survival evaluation of the ChinaHeart left ventricular assist device
    • Liu XJ, Wu GH, Xu CY, Wang J, Hou XT, Li HY et al. In vivo survival evaluation of the ChinaHeart left ventricular assist device. Chin J Biomed Eng 2012;31:737-41.
    • (2012) Chin J Biomed Eng , vol.31 , pp. 737-741
    • Liu, X.J.1    Wu, G.H.2    Xu, C.Y.3    Wang, J.4    Hou, X.T.5    Li, H.Y.6
  • 24
    • 84905500410 scopus 로고    scopus 로고
    • Study of hemolysis performance for ChinaHeart ventricular assist device
    • Xu CY, Lin CY, Hu GH, Liu XJ, Yang P, Qu WB. Study of hemolysis performance for ChinaHeart ventricular assist device. Chin Med Instrum 2012;27: 46-9.
    • (2012) Chin Med Instrum , vol.27 , pp. 46-49
    • Xu, C.Y.1    Lin, C.Y.2    Hu, G.H.3    Liu, X.J.4    Yang, P.5    Qu, W.B.6
  • 26
    • 84905474198 scopus 로고    scopus 로고
    • National Center for Cardiovascular Diseases
    • Encyclopedia of China Publishing House.
    • National Center for Cardiovascular Diseases. Report on cardiovascular disease in China (2011), Encyclopedia of China Publishing House.
    • (2011) Report on cardiovascular disease in China
  • 27
    • 84905474195 scopus 로고    scopus 로고
    • Heart Transplantation in China.
    • Chinese Transplant Congress. China: Xiamen.2012.
    • Hu SS, Wang CH, Dong NG, Chen LW, Pan TC. Heart Transplantation in China, 2012 Chinese Transplant Congress. China: Xiamen, 2012.
    • (2012)
    • Hu, S.S.1    Wang, C.H.2    Dong, N.G.3    Chen, L.W.4    Pan, T.C.5
  • 29
    • 84905450976 scopus 로고    scopus 로고
    • The development of extracorporeal membrane oxygenationin China
    • Gao GD, Hei FL. The development of extracorporeal membrane oxygenationin China. N Chin Med Info 2012;27:20.
    • (2012) N Chin Med Info , vol.27 , pp. 20
    • Gao, G.D.1    Hei, F.L.2
  • 30
    • 84905498991 scopus 로고    scopus 로고
    • China Food Drug Administration. Circulatory Support System of theImpella Pump
    • [published 23 April 2013] (31 October 2013.date last accessed).
    • China Food and Drug Administration. Circulatory Support System of theImpella Pump. [published 23 April 2013] http://app1.sfda.gov.cn/datasearch/face3/dir.html (31 October 2013, date last accessed).