-
1
-
-
33745492985
-
The design conception and realization of pulsatile ventricular assist devices: from spiralvortex pump to Luo-Ye pump
-
Ye CX, Uumezu M, Nakamura T, Luo ZX, Fan RX, Xiao XJ. The design conception and realization of pulsatile ventricular assist devices: from spiralvortex pump to Luo-Ye pump. Chin J Clin Thorac Cardiovasc Surg 2002;9:35-40.
-
(2002)
Chin J Clin Thorac Cardiovasc Surg
, vol.9
, pp. 35-40
-
-
Ye, C.X.1
Uumezu, M.2
Nakamura, T.3
Luo, Z.X.4
Fan, R.X.5
Xiao, X.J.6
-
2
-
-
84905484250
-
Animal experimentwith a newly developed LVAD pump
-
Fan RX, Xiao XJ, Cheng AH, Huang HL, Ding YQ, Gao WM et al. Animal experimentwith a newly developed LVAD pump. BME Clin Med 2002;6:1-3.
-
(2002)
BME Clin Med
, vol.6
, pp. 1-3
-
-
Fan, R.X.1
Xiao, X.J.2
Cheng, A.H.3
Huang, H.L.4
Ding, Y.Q.5
Gao, W.M.6
-
3
-
-
33745485888
-
The clinical trial of pneumatic pump (Luo-Yepump) as left ventricular assist device
-
Xiao XJ, Fan RX, Cheng AH. The clinical trial of pneumatic pump (Luo-Yepump) as left ventricular assist device. South China J Cardiovasc Dis 2002;8:43-5.
-
(2002)
South China J Cardiovasc Dis
, vol.8
, pp. 43-45
-
-
Xiao, X.J.1
Fan, R.X.2
Cheng, A.H.3
-
4
-
-
84905436321
-
Development ofPediatric Luo-Ye pump
-
Huang HL, Xiao XJ, Liu P, Cheng AH, Wu YH, Zhuang J. Development ofPediatric Luo-Ye pump. Chin Med Device 2012;27:57-9.
-
(2012)
Chin Med Device
, vol.27
, pp. 57-59
-
-
Huang, H.L.1
Xiao, X.J.2
Liu, P.3
Cheng, A.H.4
Wu, Y.H.5
Zhuang, J.6
-
5
-
-
84905459344
-
The comparison of animal experiment between Luo-Ye pumpand Excor pump
-
Wu YH. The comparison of animal experiment between Luo-Ye pumpand Excor pump. Chin J Pathophysiol 2010;26:1995.
-
(2010)
Chin J Pathophysiol
, vol.26
, pp. 1995
-
-
Wu, Y.H.1
-
6
-
-
84905491295
-
Experimental research onendothelialization of diaphragm-pneumatic left ventricular assistpump-Luo-Ye pump
-
Li H, Huang HL, Xiao XJ, Lin QX, Cheng AH. Experimental research onendothelialization of diaphragm-pneumatic left ventricular assistpump-Luo-Ye pump. Chin J ECC 2011;9:111-4.
-
(2011)
Chin J ECC
, vol.9
, pp. 111-114
-
-
Li, H.1
Huang, H.L.2
Xiao, X.J.3
Lin, Q.X.4
Cheng, A.H.5
-
7
-
-
41349095070
-
Design optimizationof an axial blood pump with computational fluid dynamics
-
Zhang Y, Zhan Z, Gui XM, Sun HS, Zhang H, Zheng Z et al. Design optimizationof an axial blood pump with computational fluid dynamics.ASAIO J 2008;54:150-5.
-
(2008)
A.S.A.I.O J
, vol.54
, pp. 150-155
-
-
Zhang, Y.1
Zhan, Z.2
Gui, X.M.3
Sun, H.S.4
Zhang, H.5
Zheng, Z.6
-
8
-
-
84905450119
-
Study of a miniature axialpump implanted at ventricular apex
-
Li GR, Zhu XD, Tian BS, Zong CY, Peng YY. Study of a miniature axialpump implanted at ventricular apex. Chin Med Equip J 2008;29:3-5.
-
(2008)
Chin Med Equip J
, vol.29
, pp. 3-5
-
-
Li, G.R.1
Zhu, X.D.2
Tian, B.S.3
Zong, C.Y.4
Peng, Y.Y.5
-
9
-
-
34247281604
-
Digital simulation to thedevelopment of axial blood pump for artificial heart
-
Zhang Y, Xue S, Gui XM, Hu SS, Sun HS, Zhu XD. Digital simulation to thedevelopment of axial blood pump for artificial heart. Chin J Biomed Eng2007;26:35-41.
-
(2007)
Chin J Biomed Eng
, vol.26
, pp. 35-41
-
-
Zhang, Y.1
Xue, S.2
Gui, X.M.3
Hu, S.S.4
Sun, H.S.5
Zhu, X.D.6
-
10
-
-
59549101926
-
Design and performance testing of an axial flow ventricular assist device developed at theFu Wai Hospital in Beijing
-
Zhang Y, Hu SS, Zhou JY, Sun HS, Zhang H, Zheng Z et al. Design and performance testing of an axial flow ventricular assist device developed at theFu Wai Hospital in Beijing. Int J Artif Organ 2008;31:983-7.
-
(2008)
Int J Artif Organ
, vol.31
, pp. 983-987
-
-
Zhang, Y.1
Hu, S.S.2
Zhou, J.Y.3
Sun, H.S.4
Zhang, H.5
Zheng, Z.6
-
11
-
-
84905500901
-
Study of the temperature increase in a new heart assist device ventricular apex axial pump
-
Li GR, Zhu XD, Peng YY, Chen HF, Tian BS. Study of the temperature increase in a new heart assist device ventricular apex axial pump. ChinaMedal Dev Inform 2007;13:25-8.
-
(2007)
ChinaMedal Dev Inform
, vol.13
, pp. 25-28
-
-
Li, G.R.1
Zhu, X.D.2
Peng, Y.Y.3
Chen, H.F.4
Tian, B.S.5
-
12
-
-
84905496334
-
Study of anatomic fit of microapex pump and surgical injure in animal implantation experiments
-
Li GR, Zhu XD, Hao ZC, Tian BS, Chen HF. Study of anatomic fit of microapex pump and surgical injure in animal implantation experiments. ChinMed Equip J 2010;31:20-2.
-
(2010)
ChinMed Equip J
, vol.31
, pp. 20-22
-
-
Li, G.R.1
Zhu, X.D.2
Hao, Z.C.3
Tian, B.S.4
Chen, H.F.5
-
13
-
-
78349298282
-
Modeling and identification of an intra-aorta pump
-
Chang Y, Gao B. Modeling and identification of an intra-aorta pump. Am Soc Artif Intern Organs J 2010;56:504-9.
-
(2010)
Am Soc Artif Intern Organs J
, vol.56
, pp. 504-509
-
-
Chang, Y.1
Gao, B.2
-
14
-
-
84865866441
-
Hemodynamic simulation study of a novel intra-aorta left ventricular assist device
-
Xuan YJ, Chang Y, Gu KY, Gao B. Hemodynamic simulation study of a novel intra-aorta left ventricular assist device. Am Soc Artif Intern Organs J 2012;58:462-9.
-
(2012)
Am Soc Artif Intern Organs J
, vol.58
, pp. 462-469
-
-
Xuan, Y.J.1
Chang, Y.2
Gu, K.Y.3
Gao, B.4
-
15
-
-
84865863174
-
Computational analysis of the effect of the control model of intra aorta pump on ventricular unloading and vessel response
-
Gu KY, Chang Y, Gao B, Liu YJ. Computational analysis of the effect of the control model of intra aorta pump on ventricular unloading and vessel response. Am Soc Artif Intern Organs J 2012;58:455-61.
-
(2012)
Am Soc Artif Intern Organs J
, vol.58
, pp. 455-461
-
-
Gu, K.Y.1
Chang, Y.2
Gao, B.3
Liu, Y.J.4
-
16
-
-
84873322638
-
The hemodynamic effect of the support mode for the intra-aorta pump on the cardiovascular system
-
Gao B, Chang Y, Xuan YJ, Zeng Y, Liu YJ. The hemodynamic effect of the support mode for the intra-aorta pump on the cardiovascular system. Artif Organs 2013;37:157-65.
-
(2013)
Artif Organs
, vol.37
, pp. 157-165
-
-
Gao, B.1
Chang, Y.2
Xuan, Y.J.3
Zeng, Y.4
Liu, Y.J.5
-
17
-
-
78349249766
-
A global sliding mode controller design for an intra-aorta pump
-
Chang Y, Gao B. A global sliding mode controller design for an intra-aorta pump. Am Soc Artif Intern Organs J 2010;56:510-6.
-
(2010)
Am Soc Artif Intern Organs J
, vol.56
, pp. 510-516
-
-
Chang, Y.1
Gao, B.2
-
18
-
-
80052493160
-
A blood assist index control by intra-aorta pump: a control strategy for ventricular recovery
-
Gao B, Gu KY, Zeng Y, Liu YJ, Chang Y. A blood assist index control by intra-aorta pump: a control strategy for ventricular recovery. Am Soc Artif Intern Organs J 2011;57:358-62.
-
(2011)
Am Soc Artif Intern Organs J
, vol.57
, pp. 358-362
-
-
Gao, B.1
Gu, K.Y.2
Zeng, Y.3
Liu, Y.J.4
Chang, Y.5
-
19
-
-
84863517395
-
A pulsatile control algorithm of continuous-flow pump for heart recovery
-
Gao B, Chang Y, Gu KY, Zeng Y, Liu YJ. A pulsatile control algorithm of continuous-flow pump for heart recovery. Am Soc Artif Intern Organs J 2012;58:343-52.
-
(2012)
Am Soc Artif Intern Organs J
, vol.58
, pp. 343-352
-
-
Gao, B.1
Chang, Y.2
Gu, K.Y.3
Zeng, Y.4
Liu, Y.J.5
-
20
-
-
84858009038
-
An anti-suction control for an intra-aorta pump using blood assistant index: a numerical simulation
-
Gao B, Gu KY, Zeng Y, Chang Y. An anti-suction control for an intra-aorta pump using blood assistant index: a numerical simulation. Artif Organs 2012;36:275-90.
-
(2012)
Artif Organs
, vol.36
, pp. 275-290
-
-
Gao, B.1
Gu, K.Y.2
Zeng, Y.3
Chang, Y.4
-
21
-
-
84870771124
-
Physiological controller of an intra-aorta pump based on Baroreflex sensitivity
-
Gao B, Chang Y, Gu KY, Zeng Y, Liu YJ. Physiological controller of an intra-aorta pump based on Baroreflex sensitivity. Artif Organs 2012;36: 1015-25.
-
(2012)
Artif Organs
, vol.36
, pp. 1015-1025
-
-
Gao, B.1
Chang, Y.2
Gu, K.Y.3
Zeng, Y.4
Liu, Y.J.5
-
22
-
-
84863015580
-
Thermal analysis of a new implantable magnetic levitation blood pump
-
Guo LH, Zhang JM, Zhao L, Liu XC. Thermal analysis of a new implantable magnetic levitation blood pump. J Biomed Eng Res 2010;29:152-5.
-
(2010)
J Biomed Eng Res
, vol.29
, pp. 152-155
-
-
Guo, L.H.1
Zhang, J.M.2
Zhao, L.3
Liu, X.C.4
-
23
-
-
84869796142
-
In vivo survival evaluation of the ChinaHeart left ventricular assist device
-
Liu XJ, Wu GH, Xu CY, Wang J, Hou XT, Li HY et al. In vivo survival evaluation of the ChinaHeart left ventricular assist device. Chin J Biomed Eng 2012;31:737-41.
-
(2012)
Chin J Biomed Eng
, vol.31
, pp. 737-741
-
-
Liu, X.J.1
Wu, G.H.2
Xu, C.Y.3
Wang, J.4
Hou, X.T.5
Li, H.Y.6
-
24
-
-
84905500410
-
Study of hemolysis performance for ChinaHeart ventricular assist device
-
Xu CY, Lin CY, Hu GH, Liu XJ, Yang P, Qu WB. Study of hemolysis performance for ChinaHeart ventricular assist device. Chin Med Instrum 2012;27: 46-9.
-
(2012)
Chin Med Instrum
, vol.27
, pp. 46-49
-
-
Xu, C.Y.1
Lin, C.Y.2
Hu, G.H.3
Liu, X.J.4
Yang, P.5
Qu, W.B.6
-
25
-
-
84869227883
-
Projectedimpact of urbanization on cardiovascular disease in China
-
Faye C, Susana A, Pamela C, Pamela C, Lee G, Gu DF et al. Projectedimpact of urbanization on cardiovascular disease in China. Int J PublicHealth 2012;57:849-54.
-
(2012)
Int J PublicHealth
, vol.57
, pp. 849-854
-
-
Faye, C.1
Susana, A.2
Pamela, C.3
Pamela, C.4
Lee, G.5
Gu, D.F.6
-
26
-
-
84905474198
-
National Center for Cardiovascular Diseases
-
Encyclopedia of China Publishing House.
-
National Center for Cardiovascular Diseases. Report on cardiovascular disease in China (2011), Encyclopedia of China Publishing House.
-
(2011)
Report on cardiovascular disease in China
-
-
-
27
-
-
84905474195
-
Heart Transplantation in China.
-
Chinese Transplant Congress. China: Xiamen.2012.
-
Hu SS, Wang CH, Dong NG, Chen LW, Pan TC. Heart Transplantation in China, 2012 Chinese Transplant Congress. China: Xiamen, 2012.
-
(2012)
-
-
Hu, S.S.1
Wang, C.H.2
Dong, N.G.3
Chen, L.W.4
Pan, T.C.5
-
28
-
-
84905506525
-
Recent status of heart transplantation in Chinese multi-centers
-
Hu SS, Wang CS, Dong JG, Chen LW, Meng X. Recent status of heart transplantation in Chinese multi-centers. Chin J Organ Transplant 2012;33:264-6.
-
(2012)
Chin J Organ Transplant
, vol.33
, pp. 264-266
-
-
Hu, S.S.1
Wang, C.S.2
Dong, J.G.3
Chen, L.W.4
Meng, X.5
-
29
-
-
84905450976
-
The development of extracorporeal membrane oxygenationin China
-
Gao GD, Hei FL. The development of extracorporeal membrane oxygenationin China. N Chin Med Info 2012;27:20.
-
(2012)
N Chin Med Info
, vol.27
, pp. 20
-
-
Gao, G.D.1
Hei, F.L.2
-
30
-
-
84905498991
-
China Food Drug Administration. Circulatory Support System of theImpella Pump
-
[published 23 April 2013] (31 October 2013.date last accessed).
-
China Food and Drug Administration. Circulatory Support System of theImpella Pump. [published 23 April 2013] http://app1.sfda.gov.cn/datasearch/face3/dir.html (31 October 2013, date last accessed).
-
-
-
|