-
1
-
-
79952636198
-
Response of rotary blood pumps to changes in preload and afterload at a fixed speed setting are unphysiological when compared with the natural heart
-
Salamonsen RF, Mason DG, Ayre PJ. Response of rotary blood pumps to changes in preload and afterload at a fixed speed setting are unphysiological when compared with the natural heart. Artif Organs 2011;35:E47-E53.
-
(2011)
Artif Organs
, vol.35
-
-
Salamonsen, R.F.1
Mason, D.G.2
Ayre, P.J.3
-
2
-
-
4544289369
-
Physiologic control of rotary blood pumps: an in vitro study
-
Giridharan GA, Pantalos GM, Gillars KJ, etal. Physiologic control of rotary blood pumps: an in vitro study. ASAIO J 2004;50:403-9.
-
(2004)
ASAIO J
, vol.50
, pp. 403-409
-
-
Giridharan, G.A.1
Pantalos, G.M.2
Gillars, K.J.3
-
4
-
-
54949140445
-
Physiological control of a rotary blood pump with selectable therapeutic options: control of pulsatility gradient
-
Arndt A, Nüsser P, Graichen K, etal. Physiological control of a rotary blood pump with selectable therapeutic options: control of pulsatility gradient. Artif Organs 2008;32:761-71.
-
(2008)
Artif Organs
, vol.32
, pp. 761-771
-
-
Arndt, A.1
Nüsser, P.2
Graichen, K.3
-
5
-
-
68849088079
-
Adaptive physiological speed/flow control of rotary blood pumps in permanent implantation using intrinsic pump parameters
-
Wu Y. Adaptive physiological speed/flow control of rotary blood pumps in permanent implantation using intrinsic pump parameters. ASAIO J 2009;55:335-9.
-
(2009)
ASAIO J
, vol.55
, pp. 335-339
-
-
Wu, Y.1
-
6
-
-
78349249766
-
A global sliding mode controller design for an intra-aorta pump
-
Chang Y, Gao B. A global sliding mode controller design for an intra-aorta pump. ASAIO J 2010;56:510-6.
-
(2010)
ASAIO J
, vol.56
, pp. 510-516
-
-
Chang, Y.1
Gao, B.2
-
7
-
-
77957267367
-
Left ventricle afterload impedance control by an axial flow ventricular assist device: a potential tool for ventricular recovery
-
Moscato F, Arabia M, Colacino FM, etal. Left ventricle afterload impedance control by an axial flow ventricular assist device: a potential tool for ventricular recovery. Artif Organs 2010;34:736-44.
-
(2010)
Artif Organs
, vol.34
, pp. 736-744
-
-
Moscato, F.1
Arabia, M.2
Colacino, F.M.3
-
8
-
-
27844608511
-
Development of a reliable automatic speed control system for rotary blood pumps
-
Vollkron M, Schima H, Huber L, etal. Development of a reliable automatic speed control system for rotary blood pumps. J Heart Lung Transplant 2005;24:1878-85.
-
(2005)
J Heart Lung Transplant
, vol.24
, pp. 1878-1885
-
-
Vollkron, M.1
Schima, H.2
Huber, L.3
-
9
-
-
77149167606
-
Noninvasive activity-based control of an implantable rotary blood pump: comparative software simulation study
-
Karantonis DM, Lim E, Mason DG, etal. Noninvasive activity-based control of an implantable rotary blood pump: comparative software simulation study. Artif Organs 2010;24:E34-E45.
-
(2010)
Artif Organs
, vol.24
-
-
Karantonis, D.M.1
Lim, E.2
Mason, D.G.3
-
10
-
-
79955583086
-
Physiological control of intraaorta pump based on heart rate
-
Gao B, Nie LY, Chang Y, etal. Physiological control of intraaorta pump based on heart rate. ASAIO J 2011;57:152-7.
-
(2011)
ASAIO J
, vol.57
, pp. 152-157
-
-
Gao, B.1
Nie, L.Y.2
Chang, Y.3
-
11
-
-
79960354061
-
A model-free adaptive control to a blood pump based on heart rate
-
Chang Y, Gao B, Gu KY. A model-free adaptive control to a blood pump based on heart rate. ASAIO J 2011;57:262-7.
-
(2011)
ASAIO J
, vol.57
, pp. 262-267
-
-
Chang, Y.1
Gao, B.2
Gu, K.Y.3
-
12
-
-
33750694324
-
Interaction between carotid baroregulation and the pulsating heart: a mathematical model
-
Ursino M. Interaction between carotid baroregulation and the pulsating heart: a mathematical model. Am J Physiol 1998;275:1733-47.
-
(1998)
Am J Physiol
, vol.275
, pp. 1733-1747
-
-
Ursino, M.1
-
13
-
-
67650786759
-
Analysis of baroreflex sensitivity during undulation pump ventricular assist device support
-
Liu HJ, Shiraishi Y, Zhang XM, etal. Analysis of baroreflex sensitivity during undulation pump ventricular assist device support. Artif Organs 2009;33:561-4.
-
(2009)
Artif Organs
, vol.33
, pp. 561-564
-
-
Liu, H.J.1
Shiraishi, Y.2
Zhang, X.M.3
-
14
-
-
0030293958
-
Prognostic implications of autonomic nervous system analysis in chronic heart failure: role of heart rate variability and baroreflex sensitivity
-
Mortara A, Tavazzi L. Prognostic implications of autonomic nervous system analysis in chronic heart failure: role of heart rate variability and baroreflex sensitivity. Arch Gerontol Geriatr 1996;23:265-75.
-
(1996)
Arch Gerontol Geriatr
, vol.23
, pp. 265-275
-
-
Mortara, A.1
Tavazzi, L.2
-
15
-
-
80052493160
-
A blood assist index control by intraaorta pump: a control strategy for ventricular recovery
-
Gao B, Gu KY, Zeng Y, etal. A blood assist index control by intraaorta pump: a control strategy for ventricular recovery. ASAIO J 2011;57:358-62.
-
(2011)
ASAIO J
, vol.57
, pp. 358-362
-
-
Gao, B.1
Gu, K.Y.2
Zeng, Y.3
-
16
-
-
58249093995
-
A dynamical state space representation and performance analysis of a feedback-controlled rotary left ventricular assist device
-
Simaan MA, Ferreira A, Chen SH, etal. A dynamical state space representation and performance analysis of a feedback-controlled rotary left ventricular assist device. IEEE T Contr Syst T 2009;17:15-28.
-
(2009)
IEEE T Contr Syst T
, vol.17
, pp. 15-28
-
-
Simaan, M.A.1
Ferreira, A.2
Chen, S.H.3
-
17
-
-
65349101751
-
A control system for rotary blood pumps based on suction detection
-
Ferreira A, Boston JR, Antaki JF. A control system for rotary blood pumps based on suction detection. IEEE T Bio-Med Eng 2009;56:656-65.
-
(2009)
IEEE T Bio-Med Eng
, vol.56
, pp. 656-665
-
-
Ferreira, A.1
Boston, J.R.2
Antaki, J.F.3
-
18
-
-
58249093995
-
A dynamical state space representation and performance analysis of a feedback-controlled rotary left ventricular assist device
-
Simaan MA, Ferreira A, Chen SH, Antaki JF, Galati DG. A dynamical state space representation and performance analysis of a feedback-controlled rotary left ventricular assist device. IEEE T Contr Syst T 2009;17:15-28.
-
(2009)
IEEE T Contr Syst T
, vol.17
, pp. 15-28
-
-
Simaan, M.A.1
Ferreira, A.2
Chen, S.H.3
Antaki, J.F.4
Galati, D.G.5
-
19
-
-
84858009038
-
An anti-suction control for an intra-orta pump using blood assistant index
-
Gao B, Gu KY, Chang Y. An anti-suction control for an intra-orta pump using blood assistant index. Artif Organs 2012;36:275-82.
-
(2012)
Artif Organs
, vol.36
, pp. 275-282
-
-
Gao, B.1
Gu, K.Y.2
Chang, Y.3
-
20
-
-
78349298282
-
Modeling and identification of an intra-aorta pump
-
Chang Y, Gao B. Modeling and identification of an intra-aorta pump. ASAIO J 2010;56:504-9.
-
(2010)
ASAIO J
, vol.56
, pp. 504-509
-
-
Chang, Y.1
Gao, B.2
-
21
-
-
79951810247
-
Changes in autonomic balance in patients with decompensated chronic heart failure
-
Rydlewska A, Jankowska EA, Ponikowska B, etal. Changes in autonomic balance in patients with decompensated chronic heart failure. Clin Auton Res 2011;21:47-54.
-
(2011)
Clin Auton Res
, vol.21
, pp. 47-54
-
-
Rydlewska, A.1
Jankowska, E.A.2
Ponikowska, B.3
-
22
-
-
84860742466
-
Baroreflex sensitivity (BRS) is a good marker to modulate exercise tolerance and cardiac outcome in heart failure with preserved ejection fraction
-
Nozomi T, Eisaku N, Tomomi A, etal. Baroreflex sensitivity (BRS) is a good marker to modulate exercise tolerance and cardiac outcome in heart failure with preserved ejection fraction. J Card Fail 2007;13:S48.
-
(2007)
J Card Fail
, vol.13
-
-
Nozomi, T.1
Eisaku, N.2
Tomomi, A.3
-
23
-
-
78649438756
-
Reduced expression and activation of voltage-gated sodium channels contributes to blunted baroreflex sensitivity in heart failure rats
-
Tu HY, Zhang LB, Tran TP, etal. Reduced expression and activation of voltage-gated sodium channels contributes to blunted baroreflex sensitivity in heart failure rats. J Neurosci Res 2010;88:3337-49.
-
(2010)
J Neurosci Res
, vol.88
, pp. 3337-3349
-
-
Tu, H.Y.1
Zhang, L.B.2
Tran, T.P.3
-
24
-
-
0015594503
-
Nervous activity of afferent cardiac sympathetic fibres with atrial and ventricular endings
-
Malliani A, Recordati G, Schwartz PJ. Nervous activity of afferent cardiac sympathetic fibres with atrial and ventricular endings. J Physiol 1973;229:457-69.
-
(1973)
J Physiol
, vol.229
, pp. 457-469
-
-
Malliani, A.1
Recordati, G.2
Schwartz, P.J.3
-
25
-
-
69049108988
-
Myocardial recovery by mechanical unloading with left ventricular assist system
-
Matsumiya G, Saitoh S, Sakata Y, etal. Myocardial recovery by mechanical unloading with left ventricular assist system. Circ J 2009;73:1386-92.
-
(2009)
Circ J
, vol.73
, pp. 1386-1392
-
-
Matsumiya, G.1
Saitoh, S.2
Sakata, Y.3
-
26
-
-
67649108897
-
Increased number of circulating progenitor cells after implantation of ventricular assist devices
-
Manginas A, Tsiavou A, Sfyrakis P, etal. Increased number of circulating progenitor cells after implantation of ventricular assist devices. J Heart Lung Transplant 2009;28:710-7.
-
(2009)
J Heart Lung Transplant
, vol.28
, pp. 710-717
-
-
Manginas, A.1
Tsiavou, A.2
Sfyrakis, P.3
-
27
-
-
46549083096
-
Impact of left ventricular assist device (LVAD) support on the cardiac reverse remodeling process
-
Klotz S, Danser AHJ, Burkhoff D. Impact of left ventricular assist device (LVAD) support on the cardiac reverse remodeling process. Prog Biophys Mol Biol 2008;97:479-96.
-
(2008)
Prog Biophys Mol Biol
, vol.97
, pp. 479-496
-
-
Klotz, S.1
Danser, A.H.J.2
Burkhoff, D.3
-
28
-
-
73649109607
-
Myocardial sympathetic innervation and long-term left ventricular mechanical unloading
-
Drakos SG, Athanasoulis T, Malliaras KG, etal. Myocardial sympathetic innervation and long-term left ventricular mechanical unloading. JACC Cardiovasc Imaging 2010;3:64-70.
-
(2010)
JACC Cardiovasc Imaging
, vol.3
, pp. 64-70
-
-
Drakos, S.G.1
Athanasoulis, T.2
Malliaras, K.G.3
-
29
-
-
75449104811
-
Left ventricular remodeling and myocardial recovery on mechanical circulatory support
-
Simon MA, Primack BA, Teuteberg J, etal. Left ventricular remodeling and myocardial recovery on mechanical circulatory support. J Card Fail 2010;16:99-105.
-
(2010)
J Card Fail
, vol.16
, pp. 99-105
-
-
Simon, M.A.1
Primack, B.A.2
Teuteberg, J.3
-
30
-
-
33846240473
-
Determination of optimal duration of mechanical unloading for failing hearts to achieve bridge to recovery in a rat heterotopic heart transplantation model
-
Oriyanhan W, Tsuneyoshi H, Nishina T, etal. Determination of optimal duration of mechanical unloading for failing hearts to achieve bridge to recovery in a rat heterotopic heart transplantation model. J Heart Lung Transplant 2007;26:16-23.
-
(2007)
J Heart Lung Transplant
, vol.26
, pp. 16-23
-
-
Oriyanhan, W.1
Tsuneyoshi, H.2
Nishina, T.3
-
31
-
-
77950517612
-
Duration of left ventricular assist device support: effects on abnormal calcium cycling and functional recovery in the failing human heart
-
Ogletree ML, Sweet WE, Talerico C, etal. Duration of left ventricular assist device support: effects on abnormal calcium cycling and functional recovery in the failing human heart. J Heart Lung Transplant 2010;29:554-61.
-
(2010)
J Heart Lung Transplant
, vol.29
, pp. 554-561
-
-
Ogletree, M.L.1
Sweet, W.E.2
Talerico, C.3
-
32
-
-
65549137628
-
Baroreflex contribution to blood pressure and heart rate oscillations: time scales, time-variant characteristics and nonlinearities
-
Di RM, Parati G, Radaelli A, etal. Baroreflex contribution to blood pressure and heart rate oscillations: time scales, time-variant characteristics and nonlinearities. Philos T R Soc A 2009;367:1301-18.
-
(2009)
Philos T R Soc A
, vol.367
, pp. 1301-1318
-
-
Di, R.M.1
Parati, G.2
Radaelli, A.3
-
33
-
-
21044453458
-
Automatic disturbances rejection controller for precise motion control of permanent-magnet synchronous motors
-
Su YX, Zheng CH, Duan BY. Automatic disturbances rejection controller for precise motion control of permanent-magnet synchronous motors. IEEE T Ind Electron 2005;52:814-23.
-
(2005)
IEEE T Ind Electron
, vol.52
, pp. 814-823
-
-
Su, Y.X.1
Zheng, C.H.2
Duan, B.Y.3
-
34
-
-
0036187876
-
A noninvasive measure of baroreflex sensitivity without blood pressure measurement
-
Davies LC, Colhoun H, Coats AJS, etal. A noninvasive measure of baroreflex sensitivity without blood pressure measurement. Am Heart J 2001;143:441-7.
-
(2001)
Am Heart J
, vol.143
, pp. 441-447
-
-
Davies, L.C.1
Colhoun, H.2
Coats, A.J.S.3
|