-
1
-
-
0014985060
-
Left ventricular bypass pump for cardiac assistance [J]
-
DeBakey ME. Left ventricular bypass pump for cardiac assistance [J]. Am J Card, 1971,27:3-11.
-
(1971)
Am J Card
, vol.27
, pp. 3-11
-
-
DeBakey, M.E.1
-
2
-
-
0344994536
-
Cardiac recovery in dilated cardiomyopathy by unloading with a left ventricular assist device[J]
-
Hetzer R, Muller J, Weng Y, et al. Cardiac recovery in dilated cardiomyopathy by unloading with a left ventricular assist device[J]. Ann Thorac Surg, 1999,68:742-749.
-
(1999)
Ann Thorac Surg
, vol.68
, pp. 742-749
-
-
Hetzer, R.1
Muller, J.2
Weng, Y.3
-
3
-
-
0346788538
-
Mechanical circulatory support for advanced heart failure. Where does it stand in 2003?
-
Frazier OH, Delgado RM. Mechanical circulatory support for advanced heart failure. Where does it stand in 2003? Circulation [J], 2003,108:3064- 3068.
-
(2003)
Circulation [J]
, vol.108
, pp. 3064-3068
-
-
Frazier, O.H.1
Delgado, R.M.2
-
4
-
-
0035892018
-
Long-term use of a left ventricular assist device for end-stage heart failure[J]
-
Rose EA, Gelijns AC, Moskowitz AJ, et al. Long-term use of a left ventricular assist device for end-stage heart failure[J]. N Engl J Med, 2001,345:1435-1443.
-
(2001)
N Engl J Med
, vol.345
, pp. 1435-1443
-
-
Rose, E.A.1
Gelijns, A.C.2
Moskowitz, A.J.3
-
5
-
-
0042809769
-
Axial flow blood pumps[J]
-
Song XW, Throckmorton A L., Untaroiu A, et al. Axial flow blood pumps[J]. ASAIO J, 2003,49:355-364.
-
(2003)
ASAIO J
, vol.49
, pp. 355-364
-
-
Song, X.W.1
Throckmorton, A.L.2
Untaroiu, A.3
-
6
-
-
27744605262
-
Numerical and experimental analysis of an axial flow left ventricular assist device: The influence of the diffuser on overall pump performance[J]
-
Untaroiu A, Throckmorton AL, Patel SM, et al. Numerical and experimental analysis of an axial flow left ventricular assist device: the influence of the diffuser on overall pump performance[J]. Artificial Organs, 2005,29(7):581-591.
-
(2005)
Artificial Organs
, vol.29
, Issue.7
, pp. 581-591
-
-
Untaroiu, A.1
Throckmorton, A.L.2
Patel, S.M.3
-
7
-
-
20644438647
-
Numerical investigation of the effects of the clearance gap between the inducer and impeller of an axial blood pump[J]
-
Chan WK, Wong YW, Ong W, et al. Numerical investigation of the effects of the clearance gap between the inducer and impeller of an axial blood pump[J]. Artificial Organs, 2005,29(3):250-258.
-
(2005)
Artificial Organs
, vol.29
, Issue.3
, pp. 250-258
-
-
Chan, W.K.1
Wong, Y.W.2
Ong, W.3
-
8
-
-
34247193294
-
-
Chinese source
-
Chinese source
-
-
-
-
10
-
-
0037237951
-
Computational Fluid Dynamics Analysis of an Intra-Cardiac Axial Flow Pump
-
Mitoh A, Yano T, Sekine K, et al. Computational Fluid Dynamics Analysis of an Intra-Cardiac Axial Flow Pump. Artificial Organs, 2003,27(1):34-40.
-
(2003)
Artificial Organs
, vol.27
, Issue.1
, pp. 34-40
-
-
Mitoh, A.1
Yano, T.2
Sekine, K.3
-
11
-
-
0027237039
-
In vitro performance of the Baylor/NASA axial flow pump
-
Damm G, Mizuguchi K, Bozeman R, et al. In vitro performance of the Baylor/NASA axial flow pump. Artif Organs. 1993,17(7):609 -13.
-
(1993)
Artif Organs
, vol.17
, Issue.7
, pp. 609-613
-
-
Damm, G.1
Mizuguchi, K.2
Bozeman, R.3
-
12
-
-
0028009306
-
Development of the Baylor/NASA axial flow ventricular assist device: In vitro performance and systematic hemolysis test results[J]
-
Mizuguchi K, Damm GA, Bozeman RJ, et al. Development of the Baylor/NASA axial flow ventricular assist device: in vitro performance and systematic hemolysis test results[J]. Artif Organs, 1994,18(1):32-43.
-
(1994)
Artif Organs
, vol.18
, Issue.1
, pp. 32-43
-
-
Mizuguchi, K.1
Damm, G.A.2
Bozeman, R.J.3
-
13
-
-
27744452104
-
Computational fluid dynamics of gap flow in a biocentrifugal blood pump[J]
-
Chua LP, Song G, Yu CM, et al. Computational fluid dynamics of gap flow in a biocentrifugal blood pump[J]. Artificial Organs, 2005,29(8): 620-628.
-
(2005)
Artificial Organs
, vol.29
, Issue.8
, pp. 620-628
-
-
Chua, L.P.1
Song, G.2
Yu, C.M.3
|