Digital simulation to the development of axial blood pump for artificial heart

Author keywords

Artificial heart; Computational fluid dynamics (CFD); Digital simulation; External bearing pump; Ventricular assist devices

Indexed keywords

ARTICLE; ARTIFICIAL HEART; BLOOD PUMP; COMPUTATIONAL FLUID DYNAMICS; COMPUTER PROGRAM; DIGITAL IMAGING; HEART LEFT VENTRICLE; MEDICAL INSTRUMENTATION;

EID: 34247281604     PISSN: 02588021     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (10)

References (13)
  • 1
    • 0014985060 scopus 로고
    • Left ventricular bypass pump for cardiac assistance [J]
    • DeBakey ME. Left ventricular bypass pump for cardiac assistance [J]. Am J Card, 1971,27:3-11.
    • (1971) Am J Card , vol.27 , pp. 3-11
    • DeBakey, M.E.1
  • 2
    • 0344994536 scopus 로고    scopus 로고
    • Cardiac recovery in dilated cardiomyopathy by unloading with a left ventricular assist device[J]
    • Hetzer R, Muller J, Weng Y, et al. Cardiac recovery in dilated cardiomyopathy by unloading with a left ventricular assist device[J]. Ann Thorac Surg, 1999,68:742-749.
    • (1999) Ann Thorac Surg , vol.68 , pp. 742-749
    • Hetzer, R.1    Muller, J.2    Weng, Y.3
  • 3
    • 0346788538 scopus 로고    scopus 로고
    • Mechanical circulatory support for advanced heart failure. Where does it stand in 2003?
    • Frazier OH, Delgado RM. Mechanical circulatory support for advanced heart failure. Where does it stand in 2003? Circulation [J], 2003,108:3064- 3068.
    • (2003) Circulation [J] , vol.108 , pp. 3064-3068
    • Frazier, O.H.1    Delgado, R.M.2
  • 4
    • 0035892018 scopus 로고    scopus 로고
    • Long-term use of a left ventricular assist device for end-stage heart failure[J]
    • Rose EA, Gelijns AC, Moskowitz AJ, et al. Long-term use of a left ventricular assist device for end-stage heart failure[J]. N Engl J Med, 2001,345:1435-1443.
    • (2001) N Engl J Med , vol.345 , pp. 1435-1443
    • Rose, E.A.1    Gelijns, A.C.2    Moskowitz, A.J.3
  • 6
    • 27744605262 scopus 로고    scopus 로고
    • Numerical and experimental analysis of an axial flow left ventricular assist device: The influence of the diffuser on overall pump performance[J]
    • Untaroiu A, Throckmorton AL, Patel SM, et al. Numerical and experimental analysis of an axial flow left ventricular assist device: the influence of the diffuser on overall pump performance[J]. Artificial Organs, 2005,29(7):581-591.
    • (2005) Artificial Organs , vol.29 , Issue.7 , pp. 581-591
    • Untaroiu, A.1    Throckmorton, A.L.2    Patel, S.M.3
  • 7
    • 20644438647 scopus 로고    scopus 로고
    • Numerical investigation of the effects of the clearance gap between the inducer and impeller of an axial blood pump[J]
    • Chan WK, Wong YW, Ong W, et al. Numerical investigation of the effects of the clearance gap between the inducer and impeller of an axial blood pump[J]. Artificial Organs, 2005,29(3):250-258.
    • (2005) Artificial Organs , vol.29 , Issue.3 , pp. 250-258
    • Chan, W.K.1    Wong, Y.W.2    Ong, W.3
  • 8
    • 34247193294 scopus 로고    scopus 로고
    • Chinese source
    • Chinese source
  • 10
    • 0037237951 scopus 로고    scopus 로고
    • Computational Fluid Dynamics Analysis of an Intra-Cardiac Axial Flow Pump
    • Mitoh A, Yano T, Sekine K, et al. Computational Fluid Dynamics Analysis of an Intra-Cardiac Axial Flow Pump. Artificial Organs, 2003,27(1):34-40.
    • (2003) Artificial Organs , vol.27 , Issue.1 , pp. 34-40
    • Mitoh, A.1    Yano, T.2    Sekine, K.3
  • 11
    • 0027237039 scopus 로고
    • In vitro performance of the Baylor/NASA axial flow pump
    • Damm G, Mizuguchi K, Bozeman R, et al. In vitro performance of the Baylor/NASA axial flow pump. Artif Organs. 1993,17(7):609 -13.
    • (1993) Artif Organs , vol.17 , Issue.7 , pp. 609-613
    • Damm, G.1    Mizuguchi, K.2    Bozeman, R.3
  • 12
    • 0028009306 scopus 로고
    • Development of the Baylor/NASA axial flow ventricular assist device: In vitro performance and systematic hemolysis test results[J]
    • Mizuguchi K, Damm GA, Bozeman RJ, et al. Development of the Baylor/NASA axial flow ventricular assist device: in vitro performance and systematic hemolysis test results[J]. Artif Organs, 1994,18(1):32-43.
    • (1994) Artif Organs , vol.18 , Issue.1 , pp. 32-43
    • Mizuguchi, K.1    Damm, G.A.2    Bozeman, R.J.3
  • 13
    • 27744452104 scopus 로고    scopus 로고
    • Computational fluid dynamics of gap flow in a biocentrifugal blood pump[J]
    • Chua LP, Song G, Yu CM, et al. Computational fluid dynamics of gap flow in a biocentrifugal blood pump[J]. Artificial Organs, 2005,29(8): 620-628.
    • (2005) Artificial Organs , vol.29 , Issue.8 , pp. 620-628
    • Chua, L.P.1    Song, G.2    Yu, C.M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.