-
1
-
-
34249092461
-
Ivad study group: Results of a multicenter clinical trial with the thoratec implantable ventricular assist device
-
Slaughter MS, Tsui SS, El-Banayosy A, et al; IVAD Study Group: Results of a multicenter clinical trial with the Thoratec Implantable Ventricular Assist Device. J Thorac Cardiovasc Surg 133: 1573-1580, 2007.
-
(2007)
J Thorac Cardiovasc Surg
, vol.133
, pp. 1573-1580
-
-
Slaughter, M.S.1
Tsui, S.S.2
El-Banayosy, A.3
-
2
-
-
34547583929
-
End-organ function in patients on long-term circulatory support with continuous- or pulsatile-flow assist devices
-
DOI 10.1016/j.healun.2007.05.012, PII S1053249807004044
-
Radovancevic B, Vrtovec B, de Kort E, Radovancevic R, Gregoric ID, Frazier OH: End-organ function in patients on long-term circulatory support with continuous-or pulsatile-flow assist devices. J Heart Lung Transplant 26: 815-818, 2007. (Pubitemid 47199072)
-
(2007)
Journal of Heart and Lung Transplantation
, vol.26
, Issue.8
, pp. 815-818
-
-
Radovancevic, B.1
Vrtovec, B.2
De Kort, E.3
Radovancevic, R.4
Gregoric, I.D.5
Frazier, O.H.6
-
3
-
-
54949140445
-
Physiological control of a rotary blood pump with selectable therapeutic options: Control of pulsatility gradient
-
Arndt A, Nüsser P, Graichen K, Müller J, Lampe B: Physiological control of a rotary blood pump with selectable therapeutic options: Control of pulsatility gradient. Artif Organs 32: 761-771, 2008.
-
(2008)
Artif Organs
, vol.32
, pp. 761-771
-
-
Arndt, A.1
Nüsser, P.2
Graichen, K.3
Müller, J.4
Lampe, B.5
-
4
-
-
68849088079
-
Adaptive physiological speed/flow control of rotary blood pumps in permanent implantation using intrinsic pump parameters
-
Wu Y: Adaptive physiological speed/flow control of rotary blood pumps in permanent implantation using intrinsic pump parameters. ASAIO J 55: 335-339, 2009.
-
(2009)
ASAIO J
, vol.55
, pp. 335-339
-
-
Wu, Y.1
-
5
-
-
78349249766
-
A global sliding mode controller design for an intra-aorta pump
-
Chang Y, Gao B: A global sliding mode controller design for an intra-aorta pump. ASAIO J 56: 510-516, 2010.
-
(2010)
ASAIO J
, vol.56
, pp. 510-516
-
-
Chang, Y.1
Gao, B.2
-
6
-
-
27844608511
-
Development of a reliable automatic speed control system for rotary blood pumps
-
DOI 10.1016/j.healun.2005.02.004, PII S1053249805001154
-
Vollkron M, Schima H, Huber L, Benkowski R, Morello G, Wieselthaler G: Development of a reliable automatic speed control system for rotary blood pumps. J Heart Lung Transplant 24: 1878-1885, 2005. (Pubitemid 41641865)
-
(2005)
Journal of Heart and Lung Transplantation
, vol.24
, Issue.11
, pp. 1878-1885
-
-
Vollkron, M.1
Schima, H.2
Huber, L.3
Benkowski, R.4
Morello, G.5
Wieselthaler, G.6
-
7
-
-
79955583086
-
Physiological control of intraaorta pump based on heart rate
-
Gao B, Nie LY, Chang Y, Zeng Y: Physiological control of intraaorta pump based on heart rate. ASAIO J 57: 152-157, 2011.
-
(2011)
ASAIO J
, vol.57
, pp. 152-157
-
-
Gao, B.1
Nie, L.Y.2
Chang, Y.3
Zeng, Y.4
-
8
-
-
79960354061
-
A model-free adaptive control to a blood pump based on heart rate
-
Chang Y, Gao B, Gu K: A model-free adaptive control to a blood pump based on heart rate. ASAIO J 57: 262-267, 2011.
-
(2011)
ASAIO J
, vol.57
, pp. 262-267
-
-
Chang, Y.1
Gao, B.2
Gu, K.3
-
9
-
-
80052493160
-
A blood assist index control by intra-aorta pump: A control strategy for ventricular recovery
-
Gao B, Gu, KY, Zeng Y, et al: A blood assist index control by intra-aorta pump: A control strategy for ventricular recovery. ASAIO J 57: 358-362, 2011.
-
(2011)
ASAIO J
, vol.57
, pp. 358-362
-
-
Gao, B.1
Gu, K.Y.2
Zeng, Y.3
-
10
-
-
84858009038
-
An anti-suction control for an intro-aorta pump using blood assistant index: A numerical simulation
-
Gao B, Gu KY, Chang Y. An anti-suction control for an intro-aorta pump using blood assistant index: A numerical simulation. Artif Organs 36: 275-282, 2012.
-
(2012)
Artif Organs
, vol.36
, pp. 275-282
-
-
Gao, B.1
Gu, K.Y.2
Chang, Y.3
-
11
-
-
77958022676
-
Improved left ventricular unloading and circulatory support with synchronized pulsatile left ventricular assistance compared with continuous-flow left ventricular assistance in an acute porcine left ventricular failure model
-
Letsou GV, Pate TD, Gohean JR, et al: Improved left ventricular unloading and circulatory support with synchronized pulsatile left ventricular assistance compared with continuous-flow left ventricular assistance in an acute porcine left ventricular failure model. J Thorac Cardiovasc Surg 140: 1181-1188, 2010.
-
(2010)
J Thorac Cardiovasc Surg
, vol.140
, pp. 1181-1188
-
-
Letsou, G.V.1
Pate, T.D.2
Gohean, J.R.3
-
12
-
-
2542419343
-
Myths and truths of pulsatile and nonpulsatile perfusion during acute and chronic cardiac support
-
DOI 10.1111/j.1525-1594.2004.00086.x
-
Undar A: Myths and truths of pulsatile and nonpulsatile perfusion during acute and chronic cardiac support. Artif Organs 28: 439-443, 2004. (Pubitemid 38680156)
-
(2004)
Artificial Organs
, vol.28
, Issue.5
, pp. 439-443
-
-
Undar, A.1
-
13
-
-
18844396181
-
Cellular and hemodynamics responses of failing myocardium to continuous flow mechanical circulatory support using the DeBakey-Noon left ventricular assist device: A comparative analysis with pulsatile-type devices
-
DOI 10.1016/j.healun.2004.02.017, PII S1053249804001457
-
Thohan V, Stetson SJ, Nagueh SF, et al: Cellular and hemodynamics responses of failing myocardium to continuous flow mechanical circulatory support using the DeBakey-Noon left ventricular assist device: a comparative analysis with pulsatile-type devices. J Heart Lung Transplant 24: 566-575, 2005. (Pubitemid 40693879)
-
(2005)
Journal of Heart and Lung Transplantation
, vol.24
, Issue.5
, pp. 566-575
-
-
Thohan, V.1
Stetson, S.J.2
Nagueh, S.F.3
Rivas-Gotz, C.4
Koerner, M.M.5
Lafuente, J.A.6
Loebe, M.7
Noon, G.P.8
Torre-Amione, G.9
-
14
-
-
33646057720
-
Lvad-induced reverse remodeling: Basic and clinical implications for myocardial recovery
-
Burkhoff D, Klotz S, Mancini DM: LVAD-induced reverse remodeling: basic and clinical implications for myocardial recovery. J Card Fail 12: 227-239, 2006.
-
(2006)
J Card Fail
, vol.12
, pp. 227-239
-
-
Burkhoff, D.1
Klotz, S.2
Mancini, D.M.3
-
15
-
-
46549083096
-
Impact of left ventricular assist device (lvad) support on the cardiac reverse remodeling process
-
Klotz S, Jan Danser AH, Burkhoff D: Impact of left ventricular assist device (LVAD) support on the cardiac reverse remodeling process. Prog Biophys Mol Biol 97: 479-496, 2008.
-
(2008)
Prog Biophys Mol Biol
, vol.97
, pp. 479-496
-
-
Klotz, S.1
Jan Danser, A.H.2
Burkhoff, D.3
-
16
-
-
79955441464
-
Is bridge to recovery more likely with pulsatile left ventricular assist devices than with nonpulsatile-flow systems?
-
Krabatsch T, Schweiger M, Dandel M, et al: Is bridge to recovery more likely with pulsatile left ventricular assist devices than with nonpulsatile-flow systems? Ann Thorac Surg 91: 1335-1340, 2011.
-
(2011)
Ann Thorac Surg
, vol.91
, pp. 1335-1340
-
-
Krabatsch, T.1
Schweiger, M.2
Dandel, M.3
-
17
-
-
0037898308
-
Control strategy for maintaining physiological perfusion with rotary blood pumps
-
DOI 10.1046/j.1525-1594.2003.07089.x
-
Giridharan GA, Skliar M: Control strategy for maintaining physiological perfusion with rotary blood pumps. Artif Organs 27: 639-648, 2003. (Pubitemid 36829722)
-
(2003)
Artificial Organs
, vol.27
, Issue.7
, pp. 639-648
-
-
Giridharan, G.A.1
Skliar, M.2
-
18
-
-
79955797517
-
Flow modulation algorithms for continuous flow left ventricular assist devices to increase vascular pulsatility: A computer simulation study
-
Ising M, Warren S, Sobieski MA, et al: Flow modulation algorithms for continuous flow left ventricular assist devices to increase vascular pulsatility: A computer simulation study. Cardiovasc Eng Technol 2:90-100, 2011.
-
(2011)
Cardiovasc Eng Technol
, vol.2
, pp. 90-100
-
-
Ising, M.1
Warren, S.2
Sobieski, M.A.3
-
19
-
-
0030250453
-
Pulsatile operation of a centrifugal ventricular assist device with magnetic bearings
-
Bearnson GB, Olsen DB, Khanwilkar PS, Long JW, Allaire PE, Maslen EH: Pulsatile operation of a centrifugal ventricular assist device with magnetic bearings. ASAIO J 42: M620-M624, 1996. (Pubitemid 26363740)
-
(1996)
ASAIO Journal
, vol.42
, Issue.5
-
-
Bearnson, G.B.1
Olsen, D.B.2
Khanwilkar, P.S.3
Long, J.W.4
Allaire, P.E.5
Maslen, E.H.6
-
20
-
-
33846390671
-
Vascular pulsatility in patients with a pulsatile- or continuous-flow ventricular assist device
-
DOI 10.1016/j.jtcvs.2006.09.057, PII S0022522306019453
-
Travis AR, Giridharan GA, Pantalos GM, et al: Vascular pulsatility in patients with a pulsatile-or continuous-flow ventricular assist device. J Thorac Cardiovasc Surg 133: 517-524, 2007. (Pubitemid 46136291)
-
(2007)
Journal of Thoracic and Cardiovascular Surgery
, vol.133
, Issue.2
, pp. 517-524
-
-
Travis, A.R.1
Giridharan, G.A.2
Pantalos, G.M.3
Dowling, R.D.4
Prabhu, S.D.5
Slaughter, M.S.6
Sobieski, M.7
Undar, A.8
Farrar, D.J.9
Koenig, S.C.10
-
22
-
-
43049155862
-
-
Shanghai, P.R. China, IFAC Low Cost Automation
-
Hou ZH, Han CW, Huang WH. The Model Free Learning Adaptive Control of a Class of MISO Nonlinear Discrete Time Systems. Shanghai, P.R. China, IFAC Low Cost Automation, 1998, pp. 227-232.
-
(1998)
The Model Free Learning Adaptive Control of a Class of MISO Nonlinear Discrete Time Systems
, pp. 227-232
-
-
Hou, Z.H.1
Han, C.W.2
Huang, W.H.3
-
23
-
-
58249093995
-
A dynamical state space representation and performance analysis of a feedback-controlled rotary left ventricular assist device
-
Simaan MA, Ferreira A, Chen SH, Antaki JF, Galati DG. A dynamical state space representation and performance analysis of a feedback-controlled rotary left ventricular assist device. IEEE T Contr Syst T 17: 15-28, 2009.
-
(2009)
IEEE T Contr Syst T
, vol.17
, pp. 15-28
-
-
Simaan, M.A.1
Ferreira, A.2
Chen, S.H.3
Antaki, J.F.4
Galati, D.G.5
-
24
-
-
33750694324
-
Interaction between carotid baroregulation and the pulsating heart: A mathematical model
-
Ursino M: Interaction between carotid baroregulation and the pulsating heart: A mathematical model. Am J Physiol 275(5 Pt 2): H1733-H1747, 1998.
-
(1998)
Am J Physiol
, vol.275
, Issue.5 PART 2
-
-
Ursino, M.1
-
25
-
-
78349298282
-
Modeling and identification of an intra-aorta pump
-
Chang Y, Gao B: Modeling and identification of an intra-aorta pump. ASAIO J 56: 504-509, 2010.
-
(2010)
ASAIO J
, vol.56
, pp. 504-509
-
-
Chang, Y.1
Gao, B.2
-
26
-
-
26444477653
-
Energy equivalent pressure and total hemodynamic energy associated with the pressure-flow waveforms of a pediatric pulsatile ventricular assist device
-
DOI 10.1097/01.mat.0000179341.95404.f8
-
Weiss WJ, Lukic B, Undar A: Energy equivalent pressure and total hemodynamic energy associated with the pressure-flow waveforms of a pediatric pulsatile ventricular assist device. ASAIO J 51: 614-617, 2005. (Pubitemid 41434250)
-
(2005)
ASAIO Journal
, vol.51
, Issue.5
, pp. 614-617
-
-
Weiss, W.J.1
Lukic, B.2
Undar, A.3
-
27
-
-
77958022676
-
Improved left ventricular unloading and circulatory support with synchronized pulsatile left ventricular assistance compared with continuous-flow left ventricular assistance in an acute porcine left ventricular failure model
-
Letsou GV, Pate TD, Gohean JR, et al: Improved left ventricular unloading and circulatory support with synchronized pulsatile left ventricular assistance compared with continuous-flow left ventricular assistance in an acute porcine left ventricular failure model. J Thorac Cardiov Sur 140: 1181-1188, 2010.
-
(2010)
J Thorac Cardiov Sur
, vol.140
, pp. 1181-1188
-
-
Letsou, G.V.1
Pate, T.D.2
Gohean, J.R.3
-
28
-
-
77950516880
-
Induced pulsation of a continuous-flow total artificial heart in a mock circulatory system
-
Khalil HA, Kerr DT, Schusterman MA 2nd, Cohn WE, Frazier OH, Radovancevic B: Induced pulsation of a continuous-flow total artificial heart in a mock circulatory system. J Heart Lung Transplant 29: 568-573, 2010.
-
(2010)
J Heart Lung Transplant
, vol.29
, pp. 568-573
-
-
Khalil, H.A.1
Kerr, D.T.2
Schusterman II, M.A.3
Cohn, W.E.4
Frazier, O.H.5
Radovancevic, B.6
-
29
-
-
0027276990
-
Nonpulsatile mode of blood flow required for cardiopulmonary bypass and total body perfusion
-
Nosé Y: Nonpulsatile mode of blood flow required for cardiopulmonary bypass and total body perfusion. Artif Organs 17: 92-102, 1993. (Pubitemid 23152158)
-
(1993)
Artificial Organs
, vol.17
, Issue.2
, pp. 92-102
-
-
Nose, Y.1
-
30
-
-
0032870709
-
The effects of pulsatile versus nonpulsatile perfusion on blood viscoelasticity before and after deep hypothermic circulatory arrest in a neonatal piglet model
-
DOI 10.1046/j.1525-1594.1999.06408.x
-
Undar A, Henderson N, Thurston GB, et al: The effects of pulsatile versus nonpulsatile perfusion on blood viscoelasticity before and after deep hypothermic circulatory arrest in a neonatal piglet model. Artif Organs 23: 717-721, 1999. (Pubitemid 29383312)
-
(1999)
Artificial Organs
, vol.23
, Issue.8
, pp. 717-721
-
-
Undar, A.1
Henderson, N.2
Thurston, G.B.3
Masai, T.4
Beyer, E.A.5
Frazier, O.H.6
Fraser Jr., C.D.7
-
31
-
-
33749006907
-
Development of a mathematical model of the human circulatory system
-
DOI 10.1007/s10439-006-9164-y
-
Conlon MJ, Russell DL, Mussivand T: Development of a mathematical model of the human circulatory system. Ann Biomed Eng 34: 1400-1413, 2006. (Pubitemid 44451086)
-
(2006)
Annals of Biomedical Engineering
, vol.34
, Issue.9
, pp. 1400-1413
-
-
Conlon, M.J.1
Russell, D.L.2
Mussivand, T.3
-
32
-
-
77957267367
-
Left ventricle afterload impedance control by an axial flow ventricular assist device: A potential tool for ventricular recovery
-
Moscato F, Arabia M, Colacino FM, Naiyanetr P, Danieli GA, Schima H: Left ventricle afterload impedance control by an axial flow ventricular assist device: a potential tool for ventricular recovery. Artif Organs 34: 736-744, 2010.
-
(2010)
Artif Organs
, vol.34
, pp. 736-744
-
-
Moscato, F.1
Arabia, M.2
Colacino, F.M.3
Naiyanetr, P.4
Danieli, G.A.5
Schima, H.6
-
33
-
-
67650556658
-
On data-driven control theory: The state of the art and perspective
-
Hou ZS, Xu JX: On data-driven control theory: The state of the art and perspective. Acta Automatica Sinica 35: 650-667, 2009.
-
(2009)
Acta Automatica Sinica
, vol.35
, pp. 650-667
-
-
Hou, Z.S.1
Xu, J.X.2
-
34
-
-
43049155862
-
-
Shanghai, P.R. China, IFAC Low Cost Automation
-
Hou ZH, Han CW, Huang WH. The Model Free Learning Adaptive Control of a Class of MISO Nonlinear Discrete Time Systems. Shanghai, P.R. China, IFAC Low Cost Automation, 1998, pp. 227-232.
-
(1998)
The Model Free Learning Adaptive Control of a Class of MISO Nonlinear Discrete Time Systems
, pp. 227-232
-
-
Hou, Z.H.1
Han, C.W.2
Huang, W.H.3
|