메뉴 건너뛰기




Volumn 52, Issue 6, 2014, Pages 2019-2026

Ability of two commercially available assays (Abbott RealTime HIV-1 and Cobas AmpliPrep/Cobas TaqMan HIV-1 version 2.0) to quantify low HIV-1 RNA levels (<1,000 copies/milliliter): Comparison with clinical samples and NIBSC working reagent for nucleic acid testing assays

Author keywords

[No Author keywords available]

Indexed keywords

VIRUS RNA;

EID: 84901660829     PISSN: 00951137     EISSN: 1098660X     Source Type: Journal    
DOI: 10.1128/JCM.00288-14     Document Type: Article
Times cited : (28)

References (44)
  • 2
    • 84901650009 scopus 로고    scopus 로고
    • British HIV Association guidelines for the treatment of HIV-1-positive adults with antiretroviral therapy
    • British HIV Association
    • British HIV Association. 2014. British HIV Association guidelines for the treatment of HIV-1-positive adults with antiretroviral therapy. HIV Med. 15(Suppl 1):1-85. http://dx.doi.org/10.1111/hiv.12119
    • (2014) HIV Med. , vol.15 , Issue.SUPPL. 1 , pp. 1-85
  • 4
    • 79958791134 scopus 로고    scopus 로고
    • European AIDS Clinical Society, October 2013. European AIDS Clinical Society, Brussels, Belgium
    • European AIDS Clinical Society. 2013. Guidelines, version 7.0, October 2013. European AIDS Clinical Society, Brussels, Belgium. http://www .eacsociety.org/Portals/0/Guidelines-Online-131014.pdf.
    • (2013) Guidelines, Version 7.0
  • 5
    • 84855616052 scopus 로고    scopus 로고
    • Panel on Antiretroviral Guidelines for Adults and AdolescentsOffice of AIDS Research Advisory Council (OARAC), Rockville MD
    • Panel on Antiretroviral Guidelines for Adults and Adolescents. 2014. Guidelines for the use of antiretroviral agents in HIV-1-infected adults and adolescents. Office of AIDS Research Advisory Council (OARAC), Rockville, MD. http://aidsinfo.nih.gov/contentfiles/lvguidelines/AdultandAdolescentGL.pdf.
    • (2014) Guidelines for the Use of Antiretroviral Agents in HIV-1-infected Adults and Adolescents
  • 6
    • 84859029700 scopus 로고    scopus 로고
    • Magnitude of virologic blips is associated with a higher risk for virologic rebound in HIV-infected individuals: A recurrent events analysis
    • CANOC Collaboration
    • Grennan JT, Loutfy MR, Su D, Harrigan PR, Cooper C, Klein M, Machouf N, Montaner JS, Rourke S, Tsoukas C, Hogg B, Raboud J, CANOC Collaboration. 2012. Magnitude of virologic blips is associated with a higher risk for virologic rebound in HIV-infected individuals: a recurrent events analysis. J. Infect. Dis. 205:1230-1238. http://dx.doi.org/10.1093/infdis/jis104
    • (2012) J. Infect. Dis. , vol.205 , pp. 1230-1238
    • Grennan, J.T.1    Loutfy, M.R.2    Su, D.3    Harrigan, P.R.4    Cooper, C.5    Klein, M.6    Machouf, N.7    Montaner, J.S.8    Rourke, S.9    Tsoukas, C.10    Hogg, B.11    Raboud, J.12
  • 7
    • 84887987692 scopus 로고    scopus 로고
    • Virologic failure following persistent low-level viremia in a cohort of HIVpositive patients: Results from 12 years of observation
    • Laprise C, de Pokomandy A, Baril JG, Dufresne S, Trottier H. 2013. Virologic failure following persistent low-level viremia in a cohort of HIVpositive patients: results from 12 years of observation. Clin. Infect. Dis. 57:1489-1496. http://dx.doi.org/10.1093/cid/cit529
    • (2013) Clin. Infect. Dis. , vol.57 , pp. 1489-1496
    • Laprise, C.1    De Pokomandy, A.2    Baril, J.G.3    Dufresne, S.4    Trottier, H.5
  • 8
    • 84863115427 scopus 로고    scopus 로고
    • Plasma HIV-1 RNA detection below 50 copies/ml and risk of virologic rebound in patients receiving highly active antiretroviral therapy
    • Doyle T, Smith C, Vitiello P, Cambiano V, Johnson M, Owen A, Phillips AN, Geretti AM. 2012. Plasma HIV-1 RNA detection below 50 copies/ml and risk of virologic rebound in patients receiving highly active antiretroviral therapy. Clin. Infect. Dis. 54:724-732. http://dx.doi.org/10.1093/cid/cir936
    • (2012) Clin. Infect. Dis. , vol.54 , pp. 724-732
    • Doyle, T.1    Smith, C.2    Vitiello, P.3    Cambiano, V.4    Johnson, M.5    Owen, A.6    Phillips, A.N.7    Geretti, A.M.8
  • 9
    • 84885345758 scopus 로고    scopus 로고
    • Residual plasma viraemia and infectious HIV-1 recovery from resting memory CD4 cells in patients on antiretroviral therapy: Results from ACTG A5173
    • ACTGA5173 Team
    • Gandhi RT, Bosch RJ, Aga E, Bedison MA, Bastow B, Schmitz JL, Siliciano JD, Siliciano RF, Eron JJ, Mellors JW, ACTGA5173 Team. 2013. Residual plasma viraemia and infectious HIV-1 recovery from resting memory CD4 cells in patients on antiretroviral therapy: results from ACTG A5173. Antivir. Ther. 18:607-613. http://dx.doi.org/10.3851/IMP2543
    • (2013) Antivir. Ther. , vol.18 , pp. 607-613
    • Gandhi, R.T.1    Bosch, R.J.2    Aga, E.3    Bedison, M.A.4    Bastow, B.5    Schmitz, J.L.6    Siliciano, J.D.7    Siliciano, R.F.8    Eron, J.J.9    Mellors, J.W.10
  • 11
    • 84881314586 scopus 로고    scopus 로고
    • An undetectable polymerase chain reaction signal in routine HIV plasma viral load monitoring is associated with better virological outcomes in patients receiving highly active antiretroviral therapy
    • Dat AIDS Study Group
    • Pugliese P, Delpierre C, Cuzin L, Poizot-Martin I, Rey D, Saune K, Cottalorda J, Bettinger D, Delaugerre C, Hoen B, Dat AIDS Study Group. 2013. An undetectable polymerase chain reaction signal in routine HIV plasma viral load monitoring is associated with better virological outcomes in patients receiving highly active antiretroviral therapy. HIV Med. 14:509-515. http://dx.doi.org/10. 1111/hiv.12041
    • (2013) HIV Med. , vol.14 , pp. 509-515
    • Pugliese, P.1    Delpierre, C.2    Cuzin, L.3    Poizot-Martin, I.4    Rey, D.5    Saune, K.6    Cottalorda, J.7    Bettinger, D.8    Delaugerre, C.9    Hoen, B.10
  • 14
    • 84865189216 scopus 로고    scopus 로고
    • Comparison of the Qiagen artus HIV-1 QS-RGQ test with the Roche Cobas AmpliPrep/Cobas TaqMan HIV-1 test v2.0
    • Wall GR, Perinpanathan D, Clark DA. 2012. Comparison of the Qiagen artus HIV-1 QS-RGQ test with the Roche Cobas AmpliPrep/Cobas TaqMan HIV-1 test v2.0. J. Clin. Virol. 55:62-66. http://dx.doi.org/10.1016/j.jcv.2012.05.014
    • (2012) J. Clin. Virol. , vol.55 , pp. 62-66
    • Wall, G.R.1    Perinpanathan, D.2    Clark, D.A.3
  • 15
    • 84875803298 scopus 로고    scopus 로고
    • Comparative evaluation of the Artus HIV-1 QS-RGQ assay and the Abbott RealTime HIV-1 assay for the quantification of HIV-1 RNA in plasma
    • Garcia-Diaz A, Labbett W, Clewley GS, Guerrero-Ramos A, Geretti AM. 2013. Comparative evaluation of the Artus HIV-1 QS-RGQ assay and the Abbott RealTime HIV-1 assay for the quantification of HIV-1 RNA in plasma. J. Clin. Virol. 57:66-69. http://dx.doi.org/10.1016/j.jcv.2013.01.006
    • (2013) J. Clin. Virol. , vol.57 , pp. 66-69
    • Garcia-Diaz, A.1    Labbett, W.2    Clewley, G.S.3    Guerrero-Ramos, A.4    Geretti, A.M.5
  • 16
    • 66949118602 scopus 로고    scopus 로고
    • Accuracy of a commercial real-time polymerase chain reaction-based system for measurement of HIVRNAlevels around the limit of quantification of the assay
    • Amendola A, Milia MG, Ghisetti V, Brega C, Zaccaro P, Capobianchi MR. 2009. Accuracy of a commercial real-time polymerase chain reaction-based system for measurement of HIVRNAlevels around the limit of quantification of the assay. Clin. Infect. Dis. 48:1630-1631. http://dx.doi.org/10.1086/598990
    • (2009) Clin. Infect. Dis. , vol.48 , pp. 1630-1631
    • Amendola, A.1    Milia, M.G.2    Ghisetti, V.3    Brega, C.4    Zaccaro, P.5    Capobianchi, M.R.6
  • 17
    • 78149491596 scopus 로고    scopus 로고
    • Lack of correlation between three commercial platforms for the evaluation of human immunodeficiency virus type 1 (HIV-1) viral load at the clinically critical lower limit of quantification
    • Yan CS, Hanafi I, Kelleher AD, Carr AD, Amin J, McNally LP, Cunningham PH. 2010. Lack of correlation between three commercial platforms for the evaluation of human immunodeficiency virus type 1 (HIV-1) viral load at the clinically critical lower limit of quantification. J. Clin. Virol. 49:249-253. http://dx.doi.org/10.1016/j.jcv.2010.08.016
    • (2010) J. Clin. Virol. , vol.49 , pp. 249-253
    • Yan, C.S.1    Hanafi, I.2    Kelleher, A.D.3    Carr, A.D.4    Amin, J.5    McNally, L.P.6    Cunningham, P.H.7
  • 18
    • 80054693272 scopus 로고    scopus 로고
    • High correlation between the Roche Cobas AmpliPrep/Cobas TaqMan HIV-1, v2.0 and the Abbott m2000 RealTime HIV-1 assays for quantification of viral load in HIV-1 B and non-B subtypes
    • Karasi JC, Dziezuk F, Quennery L, Förster S, Reischl U, Colucci G, Schoener D, Seguin-Devaux C, Schmit JC. 2011. High correlation between the Roche Cobas AmpliPrep/Cobas TaqMan HIV-1, v2.0 and the Abbott m2000 RealTime HIV-1 assays for quantification of viral load in HIV-1 B and non-B subtypes. J. Clin. Virol. 52:181-186. http://dx.doi.org/10.1016/j.jcv.2011.07.002
    • (2011) J. Clin. Virol. , vol.52 , pp. 181-186
    • Karasi, J.C.1    Dziezuk, F.2    Quennery, L.3    Förster, S.4    Reischl, U.5    Colucci, G.6    Schoener, D.7    Seguin-Devaux, C.8    Schmit, J.C.9
  • 20
    • 78650907952 scopus 로고    scopus 로고
    • Comparative evaluation of the Roche Cobas AmpliPrep/Cobas TaqMan HIV-1 version 2 test using the TaqMan 48 analyzer and the Abbott RealTime HIV-1 assay
    • van Rensburg EJ, Tait K, Watt A, Schall R. 2011. Comparative evaluation of the Roche Cobas AmpliPrep/Cobas TaqMan HIV-1 version 2 test using the TaqMan 48 analyzer and the Abbott RealTime HIV-1 assay. J. Clin. Microbiol. 49:377-379. http://dx.doi.org/10.1128/JCM.01285-10
    • (2011) J. Clin. Microbiol. , vol.49 , pp. 377-379
    • Van Rensburg, E.J.1    Tait, K.2    Watt, A.3    Schall, R.4
  • 22
    • 79961128343 scopus 로고    scopus 로고
    • Standardization and performance evaluation of "modified" and "ultrasensitive" versions of the Abbott RealTime HIV-1 assay, adapted to quantify minimal residual viremia
    • Erratum 53 181 2012
    • Amendola A, Bloisi M, Marsella P, Sabatini R, Bibbò A, Angeletti C, Capobianchi MR. 2011. Standardization and performance evaluation of "modified" and "ultrasensitive" versions of the Abbott RealTime HIV-1 assay, adapted to quantify minimal residual viremia. J. Clin. Virol. 52:17-22. (Erratum 53:181, 2012.) http://dx.doi.org/10.1016/j.jcv.2011. 04.012
    • (2011) J. Clin. Virol. , vol.52 , pp. 7-22
    • Amendola, A.1    Bloisi, M.2    Marsella, P.3    Sabatini, R.4    Bibbò, A.5    Angeletti, C.6    Capobianchi, M.R.7
  • 23
    • 0037211092 scopus 로고    scopus 로고
    • Calibration of HIV-1 working reagents for nucleic acid amplification techniques against the 1st international standard for HIV-1 RNA
    • DOI 10.1016/S0166-0934(02)00187-8, PII S0166093402001878
    • Davis C, Heath A, Best S, Hewlett I, Lelie N, Schuurman R, Holmes H. 2003. Calibration of HIV-1 working reagents for nucleic acid amplification techniques against the 1st International Standard for HIV-1 RNA. J. Virol. Methods 107:37-44. http://dx.doi.org/10.1016/S0166-0934(02)00187-8 (Pubitemid 35373905)
    • (2003) Journal of Virological Methods , vol.107 , Issue.1 , pp. 37-44
    • Davis, C.1    Heath, A.2    Best, S.3    Hewlett, I.4    Lelie, N.5    Schuurman, R.6    Holmes, H.7
  • 24
    • 0024521543 scopus 로고
    • A concordance correlation coefficient to evaluate reproducibility
    • Lin LI. 1989. A concordance correlation coefficient to evaluate reproducibility. Biometrics 45:255-268
    • (1989) Biometrics , vol.45 , pp. 255-268
    • Lin, L.I.1
  • 25
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • PII S0140673686908378
    • Bland JM, Altman DG. 1986. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet i:307-310 (Pubitemid 16134762)
    • (1986) Lancet , vol.1 , Issue.8476 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 26
    • 0004116672 scopus 로고
    • Cambridge University Press, Cambridge, United Kingdom
    • Finney DJ. 1971 Probit analysis, 3rd ed. Cambridge University Press, Cambridge, United Kingdom.
    • (1971) Probit Analysis, 3rd Ed.
    • Finney, D.J.1
  • 28
    • 79954588023 scopus 로고    scopus 로고
    • Performance evaluation of the Cobas/TaqMan HIV-1 v2.0 in HIV-1 positive patients with low viral load: A comparative study
    • Paba P, Fabeni L, Ciccozzi M, Perno CF, Ciotti M. 2011. Performance evaluation of the Cobas/TaqMan HIV-1 v2.0 in HIV-1 positive patients with low viral load: a comparative study. J. Virol. Methods 173:399-402. http://dx.doi.org/10.1016/j.jviromet.2011.03.014
    • (2011) J. Virol. Methods , vol.173 , pp. 399-402
    • Paba, P.1    Fabeni, L.2    Ciccozzi, M.3    Perno, C.F.4    Ciotti, M.5
  • 30
    • 84873367194 scopus 로고    scopus 로고
    • Comparison of HIV-1 viral load assay performance in immunological stable patients with low or undetectable viremia
    • Naeth G, Ehret R, Wiesmann F, Braun P, Knechten H, Berger A. 2013. Comparison of HIV-1 viral load assay performance in immunological stable patients with low or undetectable viremia. Med. Microbiol. Immunol. 202:67-75. http://dx.doi.org/10.1007/s00430-012-0249-y.
    • (2013) Med. Microbiol. Immunol. , vol.202 , pp. 67-75
    • Naeth, G.1    Ehret, R.2    Wiesmann, F.3    Braun, P.4    Knechten, H.5    Berger, A.6
  • 32
    • 73449125872 scopus 로고    scopus 로고
    • Initial evaluation of the Roche Cobas TaqMan HIV-1 v2.0 assay for determining viral load in HIV-infected individuals
    • Taylor N, Schmid I, Egle A, Greil R, Patsch W, Oberkofler H. 2009. Initial evaluation of the Roche Cobas TaqMan HIV-1 v2.0 assay for determining viral load in HIV-infected individuals. Antivir. Ther. 14:1189-1193. http://dx.doi.org/10.3851/IMP1427
    • (2009) Antivir. Ther. , vol.14 , pp. 1189-1193
    • Taylor, N.1    Schmid, I.2    Egle, A.3    Greil, R.4    Patsch, W.5    Oberkofler, H.6
  • 33
    • 65249107130 scopus 로고    scopus 로고
    • Comparison of the Abbott RealTime human immunodeficiency virus type 1 (HIV-1) assay to the Cobas AmpliPrep/Cobas TaqMan HIV-1 test: Workflow, reliability, and direct costs
    • Sloma CR, Germer JJ, Gerads TM, Mandrekar JN, Mitchell PS, Yao JDC. 2009. Comparison of the Abbott RealTime human immunodeficiency virus type 1 (HIV-1) assay to the Cobas AmpliPrep/Cobas TaqMan HIV-1 test: workflow, reliability, and direct costs. J. Clin. Microbiol. 47: 889-895. http://dx.doi.org/10.1128/JCM. 02231-08
    • (2009) J. Clin. Microbiol. , vol.47 , pp. 889-895
    • Sloma, C.R.1    Germer, J.J.2    Gerads, T.M.3    Mandrekar, J.N.4    Mitchell, P.S.5    Yao, J.D.C.6
  • 36
    • 2342591920 scopus 로고    scopus 로고
    • Immunologic and virologic evolution during periods of intermittent and persistent low-level viremia
    • DOI 10.1097/00002030-200404300-00005
    • Karlsson AC, Younger SR, Martin JN, Grossman Z, Sinclair E, Hunt PW, Hagos E, Nixon DF, Deeks SG. 2004. Immunologic and virologic evolution during periods of intermittent and persistent low-level viremia. AIDS 18:981-989. http://dx.doi.org/10.1097/00002030-200404300-00005 (Pubitemid 38591188)
    • (2004) AIDS , vol.18 , Issue.7 , pp. 981-989
    • Karlsson, A.C.1    Younger, S.R.2    Martin, J.N.3    Grossman, Z.4    Sinclair, E.5    Hunt, P.W.6    Hagos, E.7    Nixon, D.F.8    Deeks, S.G.9
  • 37
    • 0037013040 scopus 로고    scopus 로고
    • Drug resistance at low viraemia in HIV-1-infected patients with antiretroviral combination therapy
    • DOI 10.1097/00002030-200205030-00010
    • Aleman S, Söderbärg K, Visco-Comandini U, Sitbon G, Sönnerborg A. 2002. Drug resistance at low viraemia in HIV-1-infected patients with antiretroviral combination therapy. AIDS 16:1039-1044. http://dx.doi.org/10.1097/00002030-200205030-00010 (Pubitemid 34499427)
    • (2002) AIDS , vol.16 , Issue.7 , pp. 1039-1044
    • Aleman, S.1    Soderbarg, K.2    Visco-Comandini, U.3    Sitbon, G.4    Sonnerborg, A.5
  • 38
    • 79960877415 scopus 로고    scopus 로고
    • Antiretroviral drug resistance in HIV-1-infected patients experiencing persistent low-level viremia during first-line therapy
    • Taiwo B, Gallien S, Aga E, Ribaudo H, Haubrich R, Kuritzkes DR, Eron JJ, Jr. 2011. Antiretroviral drug resistance in HIV-1-infected patients experiencing persistent low-level viremia during first-line therapy. J. Infect. Dis. 204:515-520. http://dx.doi.org/10.1093/infdis/jir353
    • (2011) J. Infect. Dis. , vol.204 , pp. 515-520
    • Taiwo, B.1    Gallien, S.2    Aga, E.3    Ribaudo, H.4    Haubrich, R.5    Kuritzkes, D.R.6    Eron Jr., J.J.7
  • 40
    • 70349644863 scopus 로고    scopus 로고
    • The performance of the new Roche Cobas AmpliPrep-Cobas TaqMan version 2.0 human immunodeficiency virus type 1 assay
    • Scott L, Carmona S, Stevens W. 2009. The performance of the new Roche Cobas AmpliPrep-Cobas TaqMan version 2.0 human immunodeficiency virus type 1 assay. J. Clin. Microbiol. 47:3400-3402. http://dx.doi.org/10.1128/JCM.00727-09
    • (2009) J. Clin. Microbiol. , vol.47 , pp. 3400-3402
    • Scott, L.1    Carmona, S.2    Stevens, W.3
  • 41
    • 67949107943 scopus 로고    scopus 로고
    • Evaluation of the new Versant HIV-1 RNA 1.0 assay (kPCR) for quantitative detection of human immunodeficiency virus type 1 RNA
    • Troppan KT, Stelzl E, Violan D, Winkler M, Kessler HH. 2009. Evaluation of the new Versant HIV-1 RNA 1.0 assay (kPCR) for quantitative detection of human immunodeficiency virus type 1 RNA. J. Clin. Virol. 46:69-74. http://dx.doi.org/10.1016/j.jcv.2009.06.012
    • (2009) J. Clin. Virol. , vol.46 , pp. 69-74
    • Troppan, K.T.1    Stelzl, E.2    Violan, D.3    Winkler, M.4    Kessler, H.H.5
  • 43
    • 84869224844 scopus 로고    scopus 로고
    • Increased risk of virologic rebound in patients on antiviral therapy with a detectable HIV load 48 copies/ml
    • Henrich TJ, Wood BR, Kuritzkes DR. 2012. Increased risk of virologic rebound in patients on antiviral therapy with a detectable HIV load 48 copies/ml. PLoS One 7:e50065. http://dx.doi.org/10.1371/journal.pone.0050065
    • (2012) PLoS One , vol.7
    • Henrich, T.J.1    Wood, B.R.2    Kuritzkes, D.R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.