메뉴 건너뛰기




Volumn 61, Issue 6, 2014, Pages 966-978

Transcranial cavitation detection in primates during blood-brain barrier opening-a performance assessment study

Author keywords

[No Author keywords available]

Indexed keywords

BLOOD; MAGNETIC RESONANCE IMAGING; MAMMALS; ULTRASONIC APPLICATIONS;

EID: 84901477538     PISSN: 08853010     EISSN: None     Source Type: Journal    
DOI: 10.1109/TUFFC.2014.2992     Document Type: Article
Times cited : (79)

References (45)
  • 1
    • 79955369724 scopus 로고    scopus 로고
    • Feasibility of noninvasive cavitation-guided blood-brain barrier opening using focused ultrasound and microbubbles in nonhuman primates
    • art. 163704 Apr. 18
    • Y. S. Tung, F. Marquet, T. Teichert, V. Ferrera, and E. E. Konofagou, "Feasibility of noninvasive cavitation-guided blood-brain barrier opening using focused ultrasound and microbubbles in nonhuman primates," Appl. Phys. Lett., vol. 98, art. no. 163704, Apr. 18, 2011.
    • (2011) Appl. Phys. Lett. , vol.98
    • Tung, Y.S.1    Marquet, F.2    Teichert, T.3    Ferrera, V.4    Konofagou, E.E.5
  • 2
    • 84863952172 scopus 로고    scopus 로고
    • Temporary disruption of the blood-brain barrier by use of ultrasound and microbubbles: Safety and efficacy evaluation in rhesus macaques
    • N . McDannold, C. D. Arvanitis, N. Vykhodtseva, and M. S. Livingstone, "Temporary disruption of the blood-brain barrier by use of ultrasound and microbubbles: Safety and efficacy evaluation in rhesus macaques," Cancer Res., vol. 72, no. 14, pp. 3652-3663, 2012.
    • (2012) Cancer Res. , vol.72 , Issue.14 , pp. 3652-3663
    • McDannold, N.1    Arvanitis, C.D.2    Vykhodtseva, N.3    Livingstone, M.S.4
  • 5
    • 4744338859 scopus 로고    scopus 로고
    • Intracranial clot lysis with intravenous microbubbles and transcranial ultrasound in swine
    • W. C. Culp, T. R. Porter, J. Lowery, F. Xie, P. K. Roberson, and L. Marky, "Intracranial clot lysis with intravenous microbubbles and transcranial ultrasound in swine," Stroke, vol. 35, no. 10, pp. 2407-2411, 2004.
    • (2004) Stroke , vol.35 , Issue.10 , pp. 2407-2411
    • Culp, W.C.1    Porter, T.R.2    Lowery, J.3    Xie, F.4    Roberson, P.K.5    Marky, L.6
  • 6
    • 75749150158 scopus 로고    scopus 로고
    • Transcranial magnetic resonance imaging-guided focused ultra sound surgery of brain tumors: Initial findings in 3 patients
    • Feb.
    • N . McDannold, G. T. Clement, P. Black, F. Jolesz, and K. Hynynen, "Transcranial magnetic resonance imaging-guided focused ultra sound surgery of brain tumors: Initial findings in 3 patients," Neurosurgery, vol. 66, pp. 323-332, Feb. 2010.
    • (2010) Neurosurgery , vol.66 , pp. 323-332
    • McDannold, N.1    Clement, G.T.2    Black, P.3    Jolesz, F.4    Hynynen, K.5
  • 8
    • 33947117433 scopus 로고    scopus 로고
    • Role of acoustic cavitation in the delivery and monitoring of cancer treatment by high-intensity focused ultrasound (HIFU)
    • Mar.
    • C. C. Coussios, C. H. Farny, G. T. Haar, and R. A. Roy, "Role of acoustic cavitation in the delivery and monitoring of cancer treatment by high-intensity focused ultrasound (HIFU)," Int. J. Hyperthermia, vol. 23, pp. 105-120, Mar. 2007.
    • (2007) Int. J. Hyperthermia , vol.23 , pp. 105-120
    • Coussios, C.C.1    Farny, C.H.2    Haar, G.T.3    Roy, R.A.4
  • 9
    • 39049103980 scopus 로고    scopus 로고
    • Applications of acoustics and cavitation to noninvasive therapy and drug delivery
    • C . C. Coussios and R. A. Roy, "Applications of acoustics and cavitation to noninvasive therapy and drug delivery," Annu. Rev. Fluid Mech., vol. 40, pp. 395-420, 2008.
    • (2008) Annu. Rev. Fluid Mech. , vol.40 , pp. 395-420
    • Coussios, C.C.1    Roy, R.A.2
  • 11
    • 33645513645 scopus 로고    scopus 로고
    • Targeted disruption of the blood-brain barrier with focused ultrasound: Association with cavitation activity
    • Feb. 21
    • N . McDannold, N. Vykhodtseva, and K. Hynynen, "Targeted disruption of the blood-brain barrier with focused ultrasound: Association with cavitation activity," Phys. Med. Biol., vol. 51, pp. 793-807, Feb. 21, 2006.
    • (2006) Phys. Med. Biol. , vol.51 , pp. 793-807
    • McDannold, N.1    Vykhodtseva, N.2    Hynynen, K.3
  • 13
    • 0038076078 scopus 로고    scopus 로고
    • Inertial cavitation dose and hemolysis produced in vitro with or without Optison
    • May
    • W. S. Chen, A. A. Brayman, T. J. Matula, and L. A. Crum, "Inertial cavitation dose and hemolysis produced in vitro with or without Optison," Ultrasound Med. Biol., vol. 29, pp. 725-737, May 2003.
    • (2003) Ultrasound Med. Biol. , vol.29 , pp. 725-737
    • Chen, W.S.1    Brayman, A.A.2    Matula, T.J.3    Crum, L.A.4
  • 14
    • 78149317618 scopus 로고    scopus 로고
    • In vivo transcranial cavitation threshold detection during ultrasound-induced blood-brain barrier opening in mice
    • Oct. 21
    • Y . S. Tung, F. Vlachos, J. J. Choi, T. Deffieux, K. Selert, and E. E. Konofagou, "In vivo transcranial cavitation threshold detection during ultrasound-induced blood-brain barrier opening in mice," Phys. Med. Biol., vol. 55, pp. 6141-6155, Oct. 21, 2010.
    • (2010) Phys. Med. Biol. , vol.55 , pp. 6141-6155
    • Tung, Y.S.1    Vlachos, F.2    Choi, J.J.3    Deffieux, T.4    Selert, K.5    Konofagou, E.E.6
  • 15
    • 84887136058 scopus 로고    scopus 로고
    • Targeted drug delivery with focused ultrasound-induced blood-brain barrier opening using acousticallyactivated nanodroplets
    • Oct. 2
    • C . C. Chen, P. S. Sheeran, S. Y. Wu, O. O. Olumolade, P. A. Dayton, and E. E. Konofagou, "Targeted drug delivery with focused ultrasound-induced blood-brain barrier opening using acousticallyactivated nanodroplets," J. Control. Release, vol. 172, pp. 795-804, Oct. 2, 2013.
    • (2013) J. Control. Release , vol.172 , pp. 795-804
    • Chen, C.C.1    Sheeran, P.S.2    Wu, S.Y.3    Olumolade, O.O.4    Dayton, P.A.5    Konofagou, E.E.6
  • 16
    • 84855437389 scopus 로고    scopus 로고
    • Attenuation, scattering, and absorption of ultrasound in the skull bone
    • Jan.
    • G. Pinton, J. F. Aubry, E. Bossy, M. Muller, M. Pernot, and M. Tanter, "Attenuation, scattering, and absorption of ultrasound in the skull bone," Med. Phys., vol. 39, pp. 299-307, Jan. 2012.
    • (2012) Med. Phys. , vol.39 , pp. 299-307
    • Pinton, G.1    Aubry, J.F.2    Bossy, E.3    Muller, M.4    Pernot, M.5    Tanter, M.6
  • 17
    • 0017964432 scopus 로고
    • Acoustical properties of the human skull
    • May
    • F. J. Fry and J. E. Barger, "Acoustical properties of the human skull," J. Acoust. Soc. Am., vol. 63, pp. 1576-1590, May 1978.
    • (1978) J. Acoust. Soc. Am. , vol.63 , pp. 1576-1590
    • Fry, F.J.1    Barger, J.E.2
  • 18
    • 79551655264 scopus 로고    scopus 로고
    • Multi-frequency characterization of the speed of sound and attenuation coefficient for longitudinal transmission of freshly excised human skulls
    • Jan. 7
    • S. Pichardo, V. W. Sin, and K. Hynynen, "Multi-frequency characterization of the speed of sound and attenuation coefficient for longitudinal transmission of freshly excised human skulls," Phys. Med. Biol., vol. 56, pp. 219-250, Jan. 7, 2011.
    • (2011) Phys. Med. Biol. , vol.56 , pp. 219-250
    • Pichardo, S.1    Sin, V.W.2    Hynynen, K.3
  • 19
    • 79952179775 scopus 로고    scopus 로고
    • Effects of nonlinear ultrasound propagation on high intensity brain therapy
    • G. Pinton, J. F. Aubry, M. Fink, and M. Tanter, "Effects of nonlinear ultrasound propagation on high intensity brain therapy," Med. Phys., vol. 38, no. 3, pp. 1207-1216, 2011.
    • (2011) Med. Phys. , vol.38 , Issue.3 , pp. 1207-1216
    • Pinton, G.1    Aubry, J.F.2    Fink, M.3    Tanter, M.4
  • 20
    • 33745619242 scopus 로고    scopus 로고
    • Longitudinal and shear mode ultrasound propagation in human skull bone
    • Jul.
    • P. J. White, G. T. Clement, and K. Hynynen, "Longitudinal and shear mode ultrasound propagation in human skull bone," Ultrasound Med. Biol., vol. 32, pp. 1085-1096, Jul. 2006.
    • (2006) Ultrasound Med. Biol. , vol.32 , pp. 1085-1096
    • White, P.J.1    Clement, G.T.2    Hynynen, K.3
  • 21
    • 0037149993 scopus 로고    scopus 로고
    • A non-invasive method for focusing ultrasound through the human skull
    • Apr. 21
    • G. T. Clement and K. Hynynen, "A non-invasive method for focusing ultrasound through the human skull," Phys. Med. Biol., vol. 47, pp. 1219-1236, Apr. 21, 2002.
    • (2002) Phys. Med. Biol. , vol.47 , pp. 1219-1236
    • Clement, G.T.1    Hynynen, K.2
  • 22
    • 78149308911 scopus 로고    scopus 로고
    • Numerical study of a simple transcranial focused ultrasound system applied to blood-brain barrier opening
    • Dec.
    • T. Deffieux and E. E. Konofagou, "Numerical study of a simple transcranial focused ultrasound system applied to blood-brain barrier opening," IEEE Trans. Ultrason. Ferroelectr. Freq. Control, vol. 57, pp. 2637-2653, Dec. 2010.
    • (2010) IEEE Trans. Ultrason. Ferroelectr. Freq. Control , vol.57 , pp. 2637-2653
    • Deffieux, T.1    Konofagou, E.E.2
  • 23
    • 67649891315 scopus 로고    scopus 로고
    • Non-invasive transcranial ultrasound therapy based on a 3D CT scan: Protocol validation and in vitro results
    • May 7
    • F. Marquet, M. Pernot, J. F. Aubry, G. Montaldo, L. Marsac, M. Tanter, and M. Fink, "Non-invasive transcranial ultrasound therapy based on a 3D CT scan: Protocol validation and in vitro results," Phys. Med. Biol., vol. 54, pp. 2597-2613, May 7, 2009.
    • (2009) Phys. Med. Biol. , vol.54 , pp. 2597-2613
    • Marquet, F.1    Pernot, M.2    Aubry, J.F.3    Montaldo, G.4    Marsac, L.5    Tanter, M.6    Fink, M.7
  • 24
    • 84866695726 scopus 로고    scopus 로고
    • Controlled ultrasound-induced blood-brain barrier disruption using passive acoustic emissions monitoring
    • art. no. e45783
    • C. D. Arvanitis, M. S. Livingstone, N. Vykhodtseva, and N. McDannold, "Controlled ultrasound-induced blood-brain barrier disruption using passive acoustic emissions monitoring," PLoS ONE, vol. 7, no. 9, art. no. e45783, 2012.
    • (2012) PLoS ONE , vol.7 , Issue.9
    • Arvanitis, C.D.1    Livingstone, M.S.2    Vykhodtseva, N.3    McDannold, N.4
  • 25
    • 84895551360 scopus 로고    scopus 로고
    • Real-time transcranial monitoring of safe blood-brain barrier opening in non-human primates
    • art. no. e84310
    • F. Marquet, T. Teichert, S. Y. Wu, Y. S. Tung, M. Downs, S. Wang, C. Chen, V. Ferrera, and E. E. Konofagou, "Real-time transcranial monitoring of safe blood-brain barrier opening in non-human primates," PLoS ONE, vol. 9, no. 2, art. no. e84310, 2014.
    • (2014) PLoS ONE , vol.9 , Issue.2
    • Marquet, F.1    Teichert, T.2    Wu, S.Y.3    Tung, Y.S.4    Downs, M.5    Wang, S.6    Chen, C.7    Ferrera, V.8    Konofagou, E.E.9
  • 26
    • 84879932300 scopus 로고    scopus 로고
    • Combined ultrasound and MR imaging to guide focused ultrasound therapies in the brain
    • Jul. 21
    • C . D. Arvanitis, M. S. Livingstone, and N. McDannold, "Combined ultrasound and MR imaging to guide focused ultrasound therapies in the brain," Phys. Med. Biol., vol. 58, pp. 4749-4761, Jul. 21, 2013.
    • (2013) Phys. Med. Biol. , vol.58 , pp. 4749-4761
    • Arvanitis, C.D.1    Livingstone, M.S.2    McDannold, N.3
  • 27
    • 84879959476 scopus 로고    scopus 로고
    • Transcranial passive acoustic mapping with hemispherical sparse arrays using CT-based skull-specific aberration corrections: A simulation study
    • Jul. 21
    • R . M. Jones, M. A. O'Reilly, and K. Hynynen, "Transcranial passive acoustic mapping with hemispherical sparse arrays using CT-based skull-specific aberration corrections: A simulation study," Phys. Med. Biol., vol. 58, pp. 4981-5005, Jul. 21, 2013.
    • (2013) Phys. Med. Biol. , vol.58 , pp. 4981-5005
    • Jones, R.M.1    O'Reilly, M.A.2    Hynynen, K.3
  • 28
    • 84889690717 scopus 로고    scopus 로고
    • A super-resolution ultrasound method for brain vascular mapping
    • art. 110701 Nov.
    • M. A. O'Reilly and K. Hynynen, "A super-resolution ultrasound method for brain vascular mapping," Med. Phys., vol. 40, art. no. 110701, Nov. 2013.
    • (2013) Med. Phys. , vol.40
    • O'Reilly, M.A.1    Hynynen, K.2
  • 29
    • 84863386377 scopus 로고    scopus 로고
    • Feasibility study of a clinical blood-brain barrier opening ultrasound system
    • Sep.-Dec.
    • F. Marquet, Y.-S. Tung, and E. E. Konofagou, "Feasibility study of a clinical blood-brain barrier opening ultrasound system," Nano Life, vol. 1, pp. 1-14, Sep.-Dec. 2011.
    • (2011) Nano Life , vol.1 , pp. 1-14
    • Marquet, F.1    Tung, Y.-S.2    Konofagou, E.E.3
  • 30
    • 56049103946 scopus 로고    scopus 로고
    • Microbubble size isolation by differential centrifugation
    • Jan. 15
    • J. A. Feshitan, C. C. Chen, J. J. Kwan, and M. A. Borden, "Microbubble size isolation by differential centrifugation," J. Colloid Interface Sci., vol. 329, pp. 316-324, Jan. 15, 2009.
    • (2009) J. Colloid Interface Sci. , vol.329 , pp. 316-324
    • Feshitan, J.A.1    Chen, C.C.2    Kwan, J.J.3    Borden, M.A.4
  • 31
    • 79960693179 scopus 로고    scopus 로고
    • Noninvasive, transient and selective blood-brain barrier opening in non-human primates in vivo
    • art. no. e22598
    • F. Marquet, Y. S. Tung, T. Teichert, V. P. Ferrera, and E. E. Konofagou, "Noninvasive, transient and selective blood-brain barrier opening in non-human primates in vivo," PLoS ONE, vol. 6, art. no. e22598, 2011.
    • (2011) PLoS ONE , vol.6
    • Marquet, F.1    Tung, Y.S.2    Teichert, T.3    Ferrera, V.P.4    Konofagou, E.E.5
  • 32
    • 77952309289 scopus 로고    scopus 로고
    • Identifying the inertial cavitation threshold and skull effects in a vessel phantom using focused ultrasound and microbubbles
    • May 2010
    • Y. S. Tung, J. J. Choi, B. Baseri, and E. E. Konofagou, "Identifying the inertial cavitation threshold and skull effects in a vessel phantom using focused ultrasound and microbubbles," Ultrasound Med. Biol., vol. 36, pp. 840-852, May 2010.
    • Ultrasound Med. Biol. , vol.36 , pp. 840-852
    • Tung, Y.S.1    Choi, J.J.2    Baseri, B.3    Konofagou, E.E.4
  • 38
    • 0037243861 scopus 로고    scopus 로고
    • A comparison of the fragmentation thresholds and inertial cavitation doses of different ultrasound contrast agents
    • Jan.
    • W. S. Chen, T. J. Matula, A. A. Brayman, and L. A. Crum, "A comparison of the fragmentation thresholds and inertial cavitation doses of different ultrasound contrast agents," J. Acoust. Soc. Am., vol. 113, pp. 643-651, Jan. 2003.
    • (2003) J. Acoust. Soc. Am. , vol.113 , pp. 643-651
    • Chen, W.S.1    Matula, T.J.2    Brayman, A.A.3    Crum, L.A.4
  • 40
    • 84871195476 scopus 로고    scopus 로고
    • Gauging the likelihood of stable cavitation from ultrasound contrast agents
    • Jan. 7
    • K. B. Bader and C. K. Holland, "Gauging the likelihood of stable cavitation from ultrasound contrast agents," Phys. Med. Biol., vol. 58, pp. 127-144, Jan. 7, 2013.
    • (2013) Phys. Med. Biol. , vol.58 , pp. 127-144
    • Bader, K.B.1    Holland, C.K.2
  • 41
    • 84919344000 scopus 로고    scopus 로고
    • Ambient pressure dependence of the ultra-harmonic response from contrast microbubbles
    • Jun.
    • T. Sun, N. Jia, D. Zhang, and D. Xu, "Ambient pressure dependence of the ultra-harmonic response from contrast microbubbles," J. Acoust. Soc. Am., vol. 131, pp. 4358-4364, Jun. 2012.
    • (2012) J. Acoust. Soc. Am. , vol.131 , pp. 4358-4364
    • Sun, T.1    Jia, N.2    Zhang, D.3    Xu, D.4
  • 42
    • 79551632443 scopus 로고    scopus 로고
    • Noninvasive and localized blood-brain barrier disruption using focused ultrasound can be achieved at short pulse lengths and low pulse repetition frequencies
    • J. J. Choi, K. Selert, Z. Gao, G. Samiotaki, B. Baseri, and E. E. Konofagou, "Noninvasive and localized blood-brain barrier disruption using focused ultrasound can be achieved at short pulse lengths and low pulse repetition frequencies," J. Cereb. Blood Flow Metab., vol. 31, no. 2, pp. 725-737, 2011.
    • (2011) J. Cereb. Blood Flow Metab. , vol.31 , Issue.2 , pp. 725-737
    • Choi, J.J.1    Selert, K.2    Gao, Z.3    Samiotaki, G.4    Baseri, B.5    Konofagou, E.E.6
  • 43
    • 0003239029 scopus 로고
    • Physical properties of tissue at ultrasonic frequencies
    • New York, NY: Academic Press
    • F. A. Duck, "Physical properties of tissue at ultrasonic frequencies," in Physical Properties of Tissue: A Comprehensive Reference Book. New York, NY: Academic Press, 1990, pp. 73-135.
    • (1990) Physical Properties of Tissue: A Comprehensive Reference Book , pp. 73-135
    • Duck, F.A.1
  • 44
    • 84887283837 scopus 로고    scopus 로고
    • Dependence of the reversibility of focused-ultrasound-induced blood-brain barrier opening on pressure and pulse length in vivo
    • Nov.
    • G. Samiotaki and E. E. Konofagou, "Dependence of the reversibility of focused-ultrasound-induced blood-brain barrier opening on pressure and pulse length in vivo," IEEE Trans. Ultrason. Ferroelectr. Freq. Control, vol. 60, pp. 2257-2265, Nov. 2013.
    • (2013) IEEE Trans. Ultrason. Ferroelectr. Freq. Control , vol.60 , pp. 2257-2265
    • Samiotaki, G.1    Konofagou, E.E.2
  • 45
    • 84861319114 scopus 로고    scopus 로고
    • Blood-brain barrier: Real-time feedback-controlled focused ultrasound disruption by using an acoustic emissions-based controller
    • Apr.
    • M. A. O'Reilly and K. Hynynen, "Blood-brain barrier: Real-time feedback-controlled focused ultrasound disruption by using an acoustic emissions-based controller," Radiology, vol. 263, pp. 96-106, Apr. 2012.
    • (2012) Radiology , vol.263 , pp. 96-106
    • O'Reilly, M.A.1    Hynynen, K.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.