메뉴 건너뛰기




Volumn 24, Issue 2, 2014, Pages 104-111

Automatic intraocular lens segmentation and detection in optical coherence tomography images

Author keywords

Accommodation; Accommodative IOL; Cataract surgery; Image processing; Intraocular lens; OCT

Indexed keywords

ACCURACY; ALGORITHM; ANTERIOR EYE SEGMENT; ARTICLE; CALIBRATION; GEOMETRY; IMAGE ANALYSIS; IMAGE PROCESSING; IN VITRO STUDY; LENS IMPLANT; OPTICAL COHERENCE TOMOGRAPHY; PROCESS DEVELOPMENT; SURFACE PROPERTY; ARTIFICIAL INTELLIGENCE; AUTOMATED PATTERN RECOGNITION; COMPUTER ASSISTED DIAGNOSIS; CYTOLOGY; DEVICES; HUMAN; IMAGE QUALITY; PROCEDURES; SURGERY;

EID: 84900418678     PISSN: 09393889     EISSN: 18764436     Source Type: Journal    
DOI: 10.1016/j.zemedi.2013.07.002     Document Type: Article
Times cited : (9)

References (27)
  • 2
    • 0032894659 scopus 로고    scopus 로고
    • Biometric, optical and physical changes in the isolated human crystalline lens with age in relation to presbyopia
    • Glasser A., Campbell M.C. Biometric, optical and physical changes in the isolated human crystalline lens with age in relation to presbyopia. Vision Research 1999, 39:1991-2015.
    • (1999) Vision Research , vol.39 , pp. 1991-2015
    • Glasser, A.1    Campbell, M.C.2
  • 3
    • 33751023087 scopus 로고    scopus 로고
    • Magnetic resonance imaging of aging, accommodating, phakic, and pseudophakic ciliary muscle diameters
    • Strenk S.A., Strenk L.M., Guo S. Magnetic resonance imaging of aging, accommodating, phakic, and pseudophakic ciliary muscle diameters. J Cataract Refract Surg 2006, 32:1792-1798.
    • (2006) J Cataract Refract Surg , vol.32 , pp. 1792-1798
    • Strenk, S.A.1    Strenk, L.M.2    Guo, S.3
  • 4
    • 84900464999 scopus 로고    scopus 로고
    • Accommodative iols
    • Springer Berlin Heidelberg, T. Kohnen, D.D. Koch, G.K. Krieglstein, R.N. Weinreb (Eds.)
    • Findl O. Accommodative iols. Cataract and Refractive Surgery, Essentials in Ophthalmology 2005, 85-100. Springer Berlin Heidelberg. T. Kohnen, D.D. Koch, G.K. Krieglstein, R.N. Weinreb (Eds.).
    • (2005) Cataract and Refractive Surgery, Essentials in Ophthalmology , pp. 85-100
    • Findl, O.1
  • 6
    • 46449115156 scopus 로고    scopus 로고
    • Einsatzmöglichkeiten intraokularer Multifokallinsen und Kriterien der Patientenselektion
    • Kohnen T., Kook D., Auffarth G.U., Derhartunian V. Einsatzmöglichkeiten intraokularer Multifokallinsen und Kriterien der Patientenselektion. Ophthalmologe 2008, 105:527-532.
    • (2008) Ophthalmologe , vol.105 , pp. 527-532
    • Kohnen, T.1    Kook, D.2    Auffarth, G.U.3    Derhartunian, V.4
  • 7
    • 16544390369 scopus 로고    scopus 로고
    • Pseudophakic accommodation with translation lenses - dual optic vs. mono optic
    • Langenbucher A., Reese S., Jakob C., Seitz B. Pseudophakic accommodation with translation lenses - dual optic vs. mono optic. Ophthalmic Physiol Opt 2004, 24:450-457.
    • (2004) Ophthalmic Physiol Opt , vol.24 , pp. 450-457
    • Langenbucher, A.1    Reese, S.2    Jakob, C.3    Seitz, B.4
  • 8
    • 70450214667 scopus 로고    scopus 로고
    • Bio-inspired accommodating fluidic intraocular lens
    • Qiao W., Johnson D., Tsai F.S., Cho S.H., Lo Y.H. Bio-inspired accommodating fluidic intraocular lens. Opt Lett 2009, 34:3214-3216.
    • (2009) Opt Lett , vol.34 , pp. 3214-3216
    • Qiao, W.1    Johnson, D.2    Tsai, F.S.3    Cho, S.H.4    Lo, Y.H.5
  • 11
    • 77951966165 scopus 로고    scopus 로고
    • Pilot study of new focus-shift accommodating intraocular lens
    • Cleary G., Spalton D.J., Marshall J. Pilot study of new focus-shift accommodating intraocular lens. J Cataract Refract Surg 2010, 36:762-770.
    • (2010) J Cataract Refract Surg , vol.36 , pp. 762-770
    • Cleary, G.1    Spalton, D.J.2    Marshall, J.3
  • 12
    • 81155159108 scopus 로고    scopus 로고
    • Akkommodative Intraokularlinsen - Grundlagen der klinischen Evaluation und aktuelle Ergebnisse
    • Klaproth O., Titke C., Baumeister M., Kohnen T. Akkommodative Intraokularlinsen - Grundlagen der klinischen Evaluation und aktuelle Ergebnisse. Klin Monatsbl Augenheilkd 2011, 228:666-675.
    • (2011) Klin Monatsbl Augenheilkd , vol.228 , pp. 666-675
    • Klaproth, O.1    Titke, C.2    Baumeister, M.3    Kohnen, T.4
  • 13
    • 84877784294 scopus 로고    scopus 로고
    • Evaluierung der Wertigkeit objektiver und subjektiver Verfahren zur Messung von pseudophaker Akkommodation
    • Uthoff D., Haigis W., Hepper D., Pölzl M., Holland D. Evaluierung der Wertigkeit objektiver und subjektiver Verfahren zur Messung von pseudophaker Akkommodation. Ophthalmologe 2012, 110:441-446.
    • (2012) Ophthalmologe , vol.110 , pp. 441-446
    • Uthoff, D.1    Haigis, W.2    Hepper, D.3    Pölzl, M.4    Holland, D.5
  • 14
    • 33745966728 scopus 로고    scopus 로고
    • Objective measurement of intraocular lens movement and dioptric change with a focus shift accommodating intraocular lens
    • Hancox J., Spalton D., Heatley C., Jayaram H., Marshall J. Objective measurement of intraocular lens movement and dioptric change with a focus shift accommodating intraocular lens. J Cataract Refract Surg 2006, 32:1098-1103.
    • (2006) J Cataract Refract Surg , vol.32 , pp. 1098-1103
    • Hancox, J.1    Spalton, D.2    Heatley, C.3    Jayaram, H.4    Marshall, J.5
  • 15
    • 66149192417 scopus 로고    scopus 로고
    • Pentacam scheimpflug quantitative imaging of the crystalline lens and intraocular lens
    • Rosales P., Marcos S. Pentacam scheimpflug quantitative imaging of the crystalline lens and intraocular lens. J Refract Surg 2009, 25:421-428.
    • (2009) J Refract Surg , vol.25 , pp. 421-428
    • Rosales, P.1    Marcos, S.2
  • 16
    • 78049462940 scopus 로고    scopus 로고
    • Optical coherence tomography - development, principles, applications
    • Fercher A.F. Optical coherence tomography - development, principles, applications. Z Med Phys 2010, 20:251-276.
    • (2010) Z Med Phys , vol.20 , pp. 251-276
    • Fercher, A.F.1
  • 17
    • 66449091591 scopus 로고    scopus 로고
    • Springer-Verlag, Berlin Heidelberg, W. Drexler, J.G. Fujimoto (Eds.)
    • Optical Coherence Tomography. 2008, Springer-Verlag, Berlin Heidelberg. W. Drexler, J.G. Fujimoto (Eds.).
    • (2008) Optical Coherence Tomography.
  • 18
    • 83155188873 scopus 로고    scopus 로고
    • Kontaktlose In-vivo-Bildgebung der Hornhaut und Vorderkammer des menschlichen Auges - ein qualitativer Vergleich zweier Bildgebungsmodalit ten in der Praxis
    • Eppig T., Gillner M., Langenbucher A., Seitz B., Viestenz A. Kontaktlose In-vivo-Bildgebung der Hornhaut und Vorderkammer des menschlichen Auges - ein qualitativer Vergleich zweier Bildgebungsmodalit ten in der Praxis. Klin Monbl Augenheilkd 2011, 228:1052-1059.
    • (2011) Klin Monbl Augenheilkd , vol.228 , pp. 1052-1059
    • Eppig, T.1    Gillner, M.2    Langenbucher, A.3    Seitz, B.4    Viestenz, A.5
  • 19
    • 84878511394 scopus 로고    scopus 로고
    • Biomechanical eye model and measurement setup for investigating accommodating intraocular lenses
    • Eppig T., Gillner M., Zoric K., Jäger J., Löffler A., Langenbucher A. Biomechanical eye model and measurement setup for investigating accommodating intraocular lenses. Z Med Phys 2013, 23:144-152.
    • (2013) Z Med Phys , vol.23 , pp. 144-152
    • Eppig, T.1    Gillner, M.2    Zoric, K.3    Jäger, J.4    Löffler, A.5    Langenbucher, A.6
  • 22
    • 33645120896 scopus 로고    scopus 로고
    • Ray tracing through a schematic eye containing second-order (quadric) surfaces using 4 x 4 matrix notation
    • Langenbucher A., Viestenz A., Viestenz A., Brünner H., Seitz B. Ray tracing through a schematic eye containing second-order (quadric) surfaces using 4 x 4 matrix notation. Ophthalmic Physiol Opt 2006, 26:180-188.
    • (2006) Ophthalmic Physiol Opt , vol.26 , pp. 180-188
    • Langenbucher, A.1    Viestenz, A.2    Viestenz, A.3    Brünner, H.4    Seitz, B.5
  • 25
    • 73649149387 scopus 로고    scopus 로고
    • Optical coherence tomography for quantitative surface topography
    • Ortiz S., Siedlecki D., Remon L., Marcos S. Optical coherence tomography for quantitative surface topography. Appl Opt 2009, 48:6708-6715.
    • (2009) Appl Opt , vol.48 , pp. 6708-6715
    • Ortiz, S.1    Siedlecki, D.2    Remon, L.3    Marcos, S.4
  • 26
    • 76149136028 scopus 로고    scopus 로고
    • Optical distortion correction in optical coherence tomography for quantitative ocular anterior segment by three-dimensional imaging
    • Ortiz S., Siedlecki D., Grulkowski I., Remon L., Pascual D., Wojtkowski M., et al. Optical distortion correction in optical coherence tomography for quantitative ocular anterior segment by three-dimensional imaging. Opt Express 2010, 18:2782-2796.
    • (2010) Opt Express , vol.18 , pp. 2782-2796
    • Ortiz, S.1    Siedlecki, D.2    Grulkowski, I.3    Remon, L.4    Pascual, D.5    Wojtkowski, M.6
  • 27
    • 84865609596 scopus 로고    scopus 로고
    • Evaluation of free-form iol topographies by clinically available topographers
    • Kannengiesser M., Zhu Z., Langenbucher A., Janunts E. Evaluation of free-form iol topographies by clinically available topographers. Z Med Phys 2012, 22:215-223.
    • (2012) Z Med Phys , vol.22 , pp. 215-223
    • Kannengiesser, M.1    Zhu, Z.2    Langenbucher, A.3    Janunts, E.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.