-
1
-
-
11144332105
-
Are 3 diopters of accommodation adequate for accommodating IOLs?
-
[letter]
-
Hoffman R.S., Fine I.H., and Packer M. Are 3 diopters of accommodation adequate for accommodating IOLs?. [letter]. J Cataract Refract Surg 30 (2004) 2457
-
(2004)
J Cataract Refract Surg
, vol.30
, pp. 2457
-
-
Hoffman, R.S.1
Fine, I.H.2
Packer, M.3
-
4
-
-
0034176570
-
Age-related changes in human ciliary muscle
-
Pardue M.T., and Sivak J.G. Age-related changes in human ciliary muscle. Optom Vis Sci 77 (2000) 204-210
-
(2000)
Optom Vis Sci
, vol.77
, pp. 204-210
-
-
Pardue, M.T.1
Sivak, J.G.2
-
5
-
-
0036955785
-
Monitoring accommodative ciliary muscle function using three-dimensional ultrasound
-
Stachs O., Martin H., Kirchhoff A., Stave J., Terwee T., and Guthoff R. Monitoring accommodative ciliary muscle function using three-dimensional ultrasound. Graefes Arch Clin Exp Ophthalmol 240 (2002) 906-912
-
(2002)
Graefes Arch Clin Exp Ophthalmol
, vol.240
, pp. 906-912
-
-
Stachs, O.1
Martin, H.2
Kirchhoff, A.3
Stave, J.4
Terwee, T.5
Guthoff, R.6
-
6
-
-
0032924928
-
Age-related changes in human ciliary muscle and lens: A magnetic resonance imaging study
-
Strenk S.A., Semmlow J.L., Strenk L.M., Munoz P., Gronlund-Jacob J., and DeMarco J.K. Age-related changes in human ciliary muscle and lens: A magnetic resonance imaging study. Invest Ophthalmol Vis Sci 40 (1999) 1162-1169
-
(1999)
Invest Ophthalmol Vis Sci
, vol.40
, pp. 1162-1169
-
-
Strenk, S.A.1
Semmlow, J.L.2
Strenk, L.M.3
Munoz, P.4
Gronlund-Jacob, J.5
DeMarco, J.K.6
-
7
-
-
33751023087
-
Magnetic resonance imaging of aging, accommodating, phakic, and pseudophakic ciliary muscle diameters
-
Strenk S.A., Strenk L.M., and Guo S. Magnetic resonance imaging of aging, accommodating, phakic, and pseudophakic ciliary muscle diameters. J Cataract Refract Surg 32 (2006) 1792-1798
-
(2006)
J Cataract Refract Surg
, vol.32
, pp. 1792-1798
-
-
Strenk, S.A.1
Strenk, L.M.2
Guo, S.3
-
8
-
-
25444491430
-
inventors. Variable-power lens and system
-
Accessed August 27, 2008
-
Alvarez L.W., and Humphrey W.E. inventors. Variable-power lens and system. US patent 3 507 565 (April 21, 1970). Available at: http://www.google.com/patents?id=jg5rAAAAEBAJ&dq=3507565 Accessed August 27, 2008
-
(1970)
US patent 3 507 565
-
-
Alvarez, L.W.1
Humphrey, W.E.2
-
9
-
-
33747784618
-
Cubic optical elements for an accommodative intraocular lens
-
Accessed August 27, 2008
-
Simonov A.N., Vdovin G., and Rombach M.C. Cubic optical elements for an accommodative intraocular lens. Opt Express 14 (2006) 7757-7775. Available at: http://www.opticsinfobase.org/abstract.cfm?URI=oe-14-17-7757 Accessed August 27, 2008
-
(2006)
Opt Express
, vol.14
, pp. 7757-7775
-
-
Simonov, A.N.1
Vdovin, G.2
Rombach, M.C.3
-
10
-
-
56649101211
-
Analytic function optical component
-
Accessed August 27, 2008
-
Baker J.G., Plummer W.T., and inventors. Analytic function optical component. US patent 4 650 292 (March 17, 1987). Available at: http://www.google.com/patents?id=x7Q6AAAAEBAJ&dq=4650292 Accessed August 27, 2008
-
(1987)
US patent 4 650 292
-
-
Baker, J.G.1
Plummer, W.T.2
inventors3
-
11
-
-
0004930027
-
Procedure of the rays in the eye. Imagery-laws of first order
-
Southall J.P.C. (Ed), The Optical Society of America, Rochester, NY Vol. 1, Appendix II; 301-358
-
Gullstrand A. Procedure of the rays in the eye. Imagery-laws of first order. In: Southall J.P.C. (Ed). Helmholtz's Treatise on Physiological Optics, translated from the third German edition (1924), The Optical Society of America, Rochester, NY Vol. 1, Appendix II; 301-358
-
(1924)
Helmholtz's Treatise on Physiological Optics, translated from the third German edition
-
-
Gullstrand, A.1
-
13
-
-
53849149404
-
Elastic constants of the human lens capsule
-
Accessed August 27, 2008
-
Fisher R.F. Elastic constants of the human lens capsule. J Physiol (Lond) 201 (1969) 1-19. Available at: http://www.pubmedcentral.nih.gov/picrender.fcgi?artid=1351628&blobty pe=pdf Accessed August 27, 2008
-
(1969)
J Physiol (Lond)
, vol.201
, pp. 1-19
-
-
Fisher, R.F.1
-
14
-
-
0037247622
-
Polymer refilling of presbyopic human lenses in vitro restores the ability to undergo accommodative changes
-
Accessed August 27, 2008
-
Koopmans S.A., Terwee T., Barkhof J., Haitjema H.J., and Kooijman A.C. Polymer refilling of presbyopic human lenses in vitro restores the ability to undergo accommodative changes. Invest Ophthalmol Vis Sci 44 (2003) 250-257. http://www.iovs.org/cgi/reprint/44/1/250 Accessed August 27, 2008
-
(2003)
Invest Ophthalmol Vis Sci
, vol.44
, pp. 250-257
-
-
Koopmans, S.A.1
Terwee, T.2
Barkhof, J.3
Haitjema, H.J.4
Kooijman, A.C.5
-
15
-
-
0142058998
-
Mechanical properties of the human lens capsule
-
Krag S., and Andreassen T.T. Mechanical properties of the human lens capsule. Prog Retin Eye Res 22 (2003) 749-767
-
(2003)
Prog Retin Eye Res
, vol.22
, pp. 749-767
-
-
Krag, S.1
Andreassen, T.T.2
-
16
-
-
33845772590
-
Synchrony dual-optic accommodating intraocular lens. Part 2: pilot clinical evaluation
-
Ossma I.L., Galvis A., Vargas L.G., Trager M.J., Vagefi M.R., and McLeod S.D. Synchrony dual-optic accommodating intraocular lens. Part 2: pilot clinical evaluation. J Cataract Refract Surg 33 (2007) 47-52
-
(2007)
J Cataract Refract Surg
, vol.33
, pp. 47-52
-
-
Ossma, I.L.1
Galvis, A.2
Vargas, L.G.3
Trager, M.J.4
Vagefi, M.R.5
McLeod, S.D.6
|