메뉴 건너뛰기




Volumn 8229, Issue , 2012, Pages

Three-dimensional calibration targets for optical coherence tomography

Author keywords

Calibration target; Femtosecond inscription; Optical coherence tomography; Point spread function

Indexed keywords

A-CENTER; CALIBRATION TARGETS; CLINICAL APPLICATION; DUAL WAVELENGTH; FEMTOSECOND INSCRIPTION; FS PULSE; IRON OXIDE NANOPARTICLE; PARTICLE DIAMETERS; POINT-SPREAD FUNCTION; REPETITION RATE; SPECTRAL-DOMAIN; THREE-DIMENSIONAL STRUCTURE; TRANSLATION STAGE;

EID: 84858231148     PISSN: 16057422     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.907748     Document Type: Conference Paper
Times cited : (7)

References (6)
  • 1
    • 33751337831 scopus 로고    scopus 로고
    • Review of tissue simulating phantoms for optical spectroscopy, imaging and dosimetry
    • Pogue BW and Patterson MS, "Review of tissue simulating phantoms for optical spectroscopy, imaging and dosimetry, " J. Biomed. Opt. 11(4), 041102 (2006).
    • (2006) J. Biomed. Opt. , vol.11 , Issue.4 , pp. 041102
    • Pogue, B.W.1    Patterson, M.S.2
  • 3
    • 77954974456 scopus 로고    scopus 로고
    • Three-dimensional characterization of optical coherence tomography point spread functions with a nanoparticle-embedded phantom
    • Agrawal A, Pfefer TJ, Gilani N and Drezek R, "Three-dimensional characterization of optical coherence tomography point spread functions with a nanoparticle-embedded phantom, " Opt. Lett. 35(13), 2269-2271 (2010).
    • (2010) Opt. Lett. , vol.35 , Issue.13 , pp. 2269-2271
    • Agrawal, A.1    Pfefer, T.J.2    Gilani, N.3    Drezek, R.4
  • 4
    • 80053256776 scopus 로고    scopus 로고
    • Structured three-dimensional optical phantom for optical coherence tomography
    • Curatolo A, Kennedy BF, Sampson DD, "Structured three-dimensional optical phantom for optical coherence tomography, " Opt. Exp., 19(20), 19480-19485 (2011).
    • (2011) Opt. Exp. , vol.19 , Issue.20 , pp. 19480-19485
    • Curatolo, A.1    Kennedy, B.F.2    Sampson, D.D.3
  • 5
    • 80052770306 scopus 로고    scopus 로고
    • Femtosecond laser micro-inscription of optical coherence tomography resolution test artifacts
    • Tomlins PH, Smith GN, Woolliams PD, Rasakanthan J and Sugden K, "Femtosecond laser micro-inscription of optical coherence tomography resolution test artifacts, " Biomed. Opt. Exp. 2(5), 1319-1327 (2011).
    • (2011) Biomed. Opt. Exp. , vol.2 , Issue.5 , pp. 1319-1327
    • Tomlins, P.H.1    Smith, G.N.2    Woolliams, P.D.3    Rasakanthan, J.4    Sugden, K.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.