메뉴 건너뛰기




Volumn 13, Issue 2, 2014, Pages 349-361

Computational evaluation of the thrombogenic potential of a hollow-fiber oxygenator with integrated heat exchanger during extracorporeal circulation

Author keywords

Computational fluid dynamics; Extracorporeal circulation; Multiscale analysis; Platelet activation; Thrombogenic potential

Indexed keywords

ACTIVATION ANALYSIS; CHEMICAL ACTIVATION; COMPUTATIONAL FLUID DYNAMICS; DIFFUSION IN LIQUIDS; HEAT EXCHANGERS; LAGRANGE MULTIPLIERS; OXYGENATION; RESPIRATORY THERAPY; VORTEX FLOW;

EID: 84897560138     PISSN: 16177959     EISSN: 16177940     Source Type: Journal    
DOI: 10.1007/s10237-012-0445-0     Document Type: Article
Times cited : (38)

References (44)
  • 1
    • 34548183335 scopus 로고    scopus 로고
    • Flow-induced platelet activation and damage accumulation in a mechanical heart valve: Numerical studies
    • 10.1111/j.1525-1594.2007.00446.x
    • Alemu Y, Bluestein D (2007) Flow-induced platelet activation and damage accumulation in a mechanical heart valve: numerical studies. Artif Organs 31(9): 677-688. doi: 10.1111/j.1525-1594.2007.00446.x
    • (2007) Artif Organs , vol.31 , Issue.9 , pp. 677-688
    • Alemu, Y.1    Bluestein, D.2
  • 2
    • 77956393128 scopus 로고    scopus 로고
    • Design optimization of a mechanical heart valve for reducing valve thrombogenicity-A case study with ATS valve
    • 10.1097/MAT.0b013e3181e65bf9
    • Alemu Y, Girdhar G, Xenos M, Sheriff J, Jesty J, Einav S, Bluestein D (2010) Design optimization of a mechanical heart valve for reducing valve thrombogenicity-A case study with ATS valve. ASAIO J 56(5): 389-396. doi: 10.1097/MAT.0b013e3181e65bf9
    • (2010) ASAIO J , vol.56 , Issue.5 , pp. 389-396
    • Alemu, Y.1    Girdhar, G.2    Xenos, M.3    Sheriff, J.4    Jesty, J.5    Einav, S.6    Bluestein, D.7
  • 3
    • 0034837086 scopus 로고    scopus 로고
    • Assessment of hemolysis related quantities in a microaxial blood pump by computational fluid dynamics
    • 10.1046/j.1525-1594.2001.025005341.x
    • Apel J, Paul R, Klaus S, Siess T, Reul H (2001) Assessment of hemolysis related quantities in a microaxial blood pump by computational fluid dynamics. Artif Organs 25(5): 341-347. doi: 10.1046/j.1525-1594.2001.025005341.x
    • (2001) Artif Organs , vol.25 , Issue.5 , pp. 341-347
    • Apel, J.1    Paul, R.2    Klaus, S.3    Siess, T.4    Reul, H.5
  • 4
    • 0028173066 scopus 로고
    • Simulation of non-Newtonian blood flow in an end-to-side anastomosis
    • Ballyk PD, Steinman DA, Ethier CR (1994) Simulation of non-Newtonian blood flow in an end-to-side anastomosis. Biorheology 31(5): 565-586
    • (1994) Biorheology , vol.31 , Issue.5 , pp. 565-586
    • Ballyk, P.D.1    Steinman, D.A.2    Ethier, C.R.3
  • 5
    • 34248152784 scopus 로고    scopus 로고
    • Turbulence modeling in three-dimensional stenosed arterial bifurcations
    • 10.1115/1.2401182
    • Banks J, Bressloff NW (2007) Turbulence modeling in three-dimensional stenosed arterial bifurcations. J Biomech Eng 129(1): 40-50. doi: 10.1115/1.2401182
    • (2007) J Biomech Eng , vol.129 , Issue.1 , pp. 40-50
    • Banks, J.1    Bressloff, N.W.2
  • 7
    • 33646562178 scopus 로고    scopus 로고
    • Towards optimization of the thrombogenic potential of blood recirculating cardiovascular devices using modeling approaches
    • 10.1586/17434440.3.3.267
    • Bluestein D (2006) Towards optimization of the thrombogenic potential of blood recirculating cardiovascular devices using modeling approaches. Expert Rev Med Devic 3(3): 267-270. doi: 10.1586/17434440.3.3.267
    • (2006) Expert Rev Med Devic , vol.3 , Issue.3 , pp. 267-270
    • Bluestein, D.1
  • 8
    • 77952011205 scopus 로고    scopus 로고
    • Towards non-thrombogenic performance of blood recirculating devices
    • 10.1007/s10439-010-9905-9
    • Bluestein D, Chandran KB, Manning KB (2010) Towards non-thrombogenic performance of blood recirculating devices. Ann Biomed Eng 38(3): 1236-1256. doi: 10.1007/s10439-010-9905-9
    • (2010) Ann Biomed Eng , vol.38 , Issue.3 , pp. 1236-1256
    • Bluestein, D.1    Chandran, K.B.2    Manning, K.B.3
  • 10
    • 34548191456 scopus 로고    scopus 로고
    • Comparison of the hemodynamic and thrombogenic performance of two bileaflet mechanical heart valves using a CFD/FSI model
    • 10.1115/1.2746378
    • Dumont K, Vierendeels J, Kaminsky R, van Nooten G, Verdonck P, Bluestein D (2007) Comparison of the hemodynamic and thrombogenic performance of two bileaflet mechanical heart valves using a CFD/FSI model. J Biomech Eng 129(4): 558-565. doi: 10.1115/1.2746378
    • (2007) J Biomech Eng , vol.129 , Issue.4 , pp. 558-565
    • Dumont, K.1    Vierendeels, J.2    Kaminsky, R.3    Van Nooten, G.4    Verdonck, P.5    Bluestein, D.6
  • 11
    • 0035985047 scopus 로고    scopus 로고
    • Computational flow modeling in hollow-fiber dialyzers
    • 10.1046/j.1525-1594.2002.07081.x
    • Eloot S, De Wachter D, Van Tricht I, Verdonck P (2002) Computational flow modeling in hollow-fiber dialyzers. Artif Organs 26(7): 590-599. doi: 10.1046/j.1525-1594.2002.07081.x
    • (2002) Artif Organs , vol.26 , Issue.7 , pp. 590-599
    • Eloot, S.1    De Wachter, D.2    Van Tricht, I.3    Verdonck, P.4
  • 12
    • 33645819996 scopus 로고    scopus 로고
    • Multi-scale analysis of the toraymyxin adsorption cartridge. Part II: Computational fluid-dynamic study
    • Fiore B, Soncini M, Vesentini S, Penati A, Visconti G, Redaelli A (2006) Multi-scale analysis of the toraymyxin adsorption cartridge. Part II: computational fluid-dynamic study. Int J Artif Organs 29(2): 251-260
    • (2006) Int J Artif Organs , vol.29 , Issue.2 , pp. 251-260
    • Fiore, B.1    Soncini, M.2    Vesentini, S.3    Penati, A.4    Visconti, G.5    Redaelli, A.6
  • 13
    • 70349108407 scopus 로고    scopus 로고
    • Bubble tracking through computational fluid dynamics in arterial line filters for cardiopulmonary bypass
    • 10.1097/MAT.0b013e3181b3800c00002480-200909000-00003[pii]
    • Fiore GB, Morbiducci U, Ponzini R, Redaelli A (2009) Bubble tracking through computational fluid dynamics in arterial line filters for cardiopulmonary bypass. ASAIO J 55(5): 438-444. doi: 10.1097/MAT. 0b013e3181b3800c00002480-200909000-00003[pii]
    • (2009) ASAIO J , vol.55 , Issue.5 , pp. 438-444
    • Fiore, G.B.1    Morbiducci, U.2    Ponzini, R.3    Redaelli, A.4
  • 14
    • 0031786978 scopus 로고    scopus 로고
    • Effects of blood flow pulse frequency on mass transfer efficiency of a commercial hollow fibre oxygenator
    • Fiore GB, Pennati G, Inzoli F, Mastrantonio F, Galavotti D (1998) Effects of blood flow pulse frequency on mass transfer efficiency of a commercial hollow fibre oxygenator. Int J Artif Organs 21(9): 535-541
    • (1998) Int J Artif Organs , vol.21 , Issue.9 , pp. 535-541
    • Fiore, G.B.1    Pennati, G.2    Inzoli, F.3    Mastrantonio, F.4    Galavotti, D.5
  • 15
    • 0036558775 scopus 로고    scopus 로고
    • Development of a new disposable pulsatile pump for cardiopulmonary bypass: Computational fluid-dynamic design and in vitro tests
    • Fiore GB, Redaelli A, Guadagni G, Inzoli F, Fumero R (2002) Development of a new disposable pulsatile pump for cardiopulmonary bypass: computational fluid-dynamic design and in vitro tests. ASAIO J 48(3): 260-267
    • (2002) ASAIO J , vol.48 , Issue.3 , pp. 260-267
    • Fiore, G.B.1    Redaelli, A.2    Guadagni, G.3    Inzoli, F.4    Fumero, R.5
  • 16
    • 0035985026 scopus 로고    scopus 로고
    • Predicting membrane oxygenator pressure drop using computational fluid dynamics
    • Gage KL, Gartner MJ, Burgreen GW, Wagner WR (2002) Predicting membrane oxygenator pressure drop using computational fluid dynamics. Artif Organs 26(7): 600-607
    • (2002) Artif Organs , vol.26 , Issue.7 , pp. 600-607
    • Gage, K.L.1    Gartner, M.J.2    Burgreen, G.W.3    Wagner, W.R.4
  • 19
    • 78649584627 scopus 로고    scopus 로고
    • Improving oxygenator performance using computational simulation and flow field-based parameters
    • 10.1111/j.1525-1594.2010.01157.x
    • Graefe R, Borchardt R, Arens J, Schlanstein P, Schmitz-Rode T, Steinseifer U (2010) Improving oxygenator performance using computational simulation and flow field-based parameters. Artif Organs 34(11): 930-936. doi: 10.1111/j.1525-1594.2010.01157.x
    • (2010) Artif Organs , vol.34 , Issue.11 , pp. 930-936
    • Graefe, R.1    Borchardt, R.2    Arens, J.3    Schlanstein, P.4    Schmitz-Rode, T.5    Steinseifer, U.6
  • 20
    • 0345095491 scopus 로고    scopus 로고
    • The development of the modern oxygenator
    • 10.1016/j.athoracsur.2003.09.012
    • Haworth WS (2003) The development of the modern oxygenator. Ann Thorac Surg 76(6): S2216-S2219. doi: 10.1016/j.athoracsur.2003.09.012
    • (2003) Ann Thorac Surg , vol.76 , Issue.6
    • Haworth, W.S.1
  • 21
    • 79955706450 scopus 로고    scopus 로고
    • A validated CFD model to predict O and CO transfer within hollow fiber membrane oxygenators
    • 416396B2-E82B-43ED-841D-40D440D5FB14[pii]
    • Hormes M, Borchardt R, Mager I, Rode TS, Behr M, Steinseifer U (2011) A validated CFD model to predict O and CO transfer within hollow fiber membrane oxygenators. Int J Artif Organs 34(3): 317-325. doi: 416396B2-E82B-43ED-841D- 40D440D5FB14[pii]
    • (2011) Int J Artif Organs , vol.34 , Issue.3 , pp. 317-325
    • Hormes, M.1    Borchardt, R.2    Mager, I.3    Rode, T.S.4    Behr, M.5    Steinseifer, U.6
  • 23
    • 1842471932 scopus 로고    scopus 로고
    • Non-Newtonian blood flow in human right coronary arteries: Steady state simulations
    • 10.1016/j.jbiomech.2003.09.016
    • Johnston BM, Johnston PR, Corney S, Kilpatrick D (2004) Non-Newtonian blood flow in human right coronary arteries: steady state simulations. J Biomech 37(5): 709-720. doi: 10.1016/j.jbiomech.2003.09.016
    • (2004) J Biomech , vol.37 , Issue.5 , pp. 709-720
    • Johnston, B.M.1    Johnston, P.R.2    Corney, S.3    Kilpatrick, D.4
  • 25
    • 0023155294 scopus 로고
    • Turbulence statistics in fully developed channel flow at low Reynolds number
    • 10.1017/S0022112087000892 0616.76071
    • Kim J, Moin P, Moser R (1987) Turbulence statistics in fully developed channel flow at low Reynolds number. Journal of Fluid Mechanics 177: 133-166. doi: 10.1017/S0022112087000892
    • (1987) Journal of Fluid Mechanics , vol.177 , pp. 133-166
    • Kim, J.1    Moin, P.2    Moser, R.3
  • 26
    • 41149145906 scopus 로고    scopus 로고
    • Computational fluid dynamics investigation of a centrifugal blood pump
    • 10.1111/j.1525-1594.2008.00552.x
    • Legendre D, Antunes P, Bock E, Andrade A, Biscegli JF, Ortiz JP (2008) Computational fluid dynamics investigation of a centrifugal blood pump. Artif Organs 32(4): 342-348. doi: 10.1111/j.1525-1594.2008.00552.x
    • (2008) Artif Organs , vol.32 , Issue.4 , pp. 342-348
    • Legendre, D.1    Antunes, P.2    Bock, E.3    Andrade, A.4    Biscegli, J.F.5    Ortiz, J.P.6
  • 27
    • 0035985404 scopus 로고    scopus 로고
    • In vitro comparison of blood pump induced platelet microaggregates between a centrifugal and roller pump during cardiopulmonary bypass
    • Linneweber J, Chow TW, Kawamura M, Moake JL, Nose Y (2002) In vitro comparison of blood pump induced platelet microaggregates between a centrifugal and roller pump during cardiopulmonary bypass. Int J Artif Organs 25(6): 549-555
    • (2002) Int J Artif Organs , vol.25 , Issue.6 , pp. 549-555
    • Linneweber, J.1    Chow, T.W.2    Kawamura, M.3    Moake, J.L.4    Nose, Y.5
  • 31
    • 0032857242 scopus 로고    scopus 로고
    • The effects of heparin coating of oxygenator fibers on platelet adhesion and protein adsorption
    • Niimi Y, Ichinose F, Ishiguro Y, Terui K, Uezono S, Morita S, Yamane S (1999) The effects of heparin coating of oxygenator fibers on platelet adhesion and protein adsorption. Anesth Analg 89(3): 573-579
    • (1999) Anesth Analg , vol.89 , Issue.3 , pp. 573-579
    • Niimi, Y.1    Ichinose, F.2    Ishiguro, Y.3    Terui, K.4    Uezono, S.5    Morita, S.6    Yamane, S.7
  • 32
    • 38349187878 scopus 로고    scopus 로고
    • Platelet activation due to hemodynamic shear stresses: Damage accumulation model and comparison to in vitro measurements
    • 10.1097/MAT.0b013e31815d689800002480-200801000-00012[pii]
    • Nobili M, Sheriff J, Morbiducci U, Redaelli A, Bluestein D (2008) Platelet activation due to hemodynamic shear stresses: damage accumulation model and comparison to in vitro measurements. ASAIO J 54(1): 64-72. doi: 10.1097/MAT.0b013e31815d689800002480-200801000-00012[pii]
    • (2008) ASAIO J , vol.54 , Issue.1 , pp. 64-72
    • Nobili, M.1    Sheriff, J.2    Morbiducci, U.3    Redaelli, A.4    Bluestein, D.5
  • 34
  • 35
    • 0032744911 scopus 로고    scopus 로고
    • Oxygenator thrombosis: An international phenomenon
    • Schaadt J (1999) Oxygenator thrombosis: an international phenomenon. Perfusion 14(6): 425-435
    • (1999) Perfusion , vol.14 , Issue.6 , pp. 425-435
    • Schaadt, J.1
  • 36
    • 77952011415 scopus 로고    scopus 로고
    • High-shear stress sensitizes platelets to subsequent low-shear conditions
    • 10.1007/s10439-010-9936-2
    • Sheriff J, Bluestein D, Girdhar G, Jesty J (2010) High-shear stress sensitizes platelets to subsequent low-shear conditions. Ann Biomed Eng 38(4): 1442-1450. doi: 10.1007/s10439-010-9936-2
    • (2010) Ann Biomed Eng , vol.38 , Issue.4 , pp. 1442-1450
    • Sheriff, J.1    Bluestein, D.2    Girdhar, G.3    Jesty, J.4
  • 37
    • 35148812430 scopus 로고    scopus 로고
    • Interstitial flow and its effects in soft tissues
    • 10.1146/annurev.bioeng.9.060906.151850
    • Swartz MA, Fleury ME (2007) Interstitial flow and its effects in soft tissues. Annu Rev Biomed Eng 9: 229-256. doi: 10.1146/annurev.bioeng.9.060906. 151850
    • (2007) Annu Rev Biomed Eng , vol.9 , pp. 229-256
    • Swartz, M.A.1    Fleury, M.E.2
  • 38
    • 0035164951 scopus 로고    scopus 로고
    • Platelet damage caused by the centrifugal pump: Laser-light scattering analysis of aggregation patterns
    • Tanaka M, Kawahito K, Adachi H, Isawa H, Ino T (2001) Platelet damage caused by the centrifugal pump: laser-light scattering analysis of aggregation patterns. Artif Organs 25(9): 719-723
    • (2001) Artif Organs , vol.25 , Issue.9 , pp. 719-723
    • Tanaka, M.1    Kawahito, K.2    Adachi, H.3    Isawa, H.4    Ino, T.5
  • 39
    • 0042476695 scopus 로고    scopus 로고
    • Numerical modeling of pulsatile turbulent flow in stenotic vessels
    • Varghese SS, Frankel SH (2003) Numerical modeling of pulsatile turbulent flow in stenotic vessels. J Biomech Eng 125(4): 445-460
    • (2003) J Biomech Eng , vol.125 , Issue.4 , pp. 445-460
    • Varghese, S.S.1    Frankel, S.H.2
  • 40
    • 0035985022 scopus 로고    scopus 로고
    • The role of computational fluid dynamics for artificial organ design
    • Verdonck P (2002) The role of computational fluid dynamics for artificial organ design. Artif Organs 26(7): 569-570
    • (2002) Artif Organs , vol.26 , Issue.7 , pp. 569-570
    • Verdonck, P.1
  • 41
    • 33645799681 scopus 로고    scopus 로고
    • Multi-scale analysis of the toraymyxin adsorption cartridge. Part I: Molecular interaction of polymyxin B with endotoxins
    • Vesentini S, Soncini M, Zaupa A, Silvestri V, Fiore GB, Redaelli A (2006) Multi-scale analysis of the toraymyxin adsorption cartridge. Part I: molecular interaction of polymyxin B with endotoxins. Int J Artif Organs 29(2): 239-250
    • (2006) Int J Artif Organs , vol.29 , Issue.2 , pp. 239-250
    • Vesentini, S.1    Soncini, M.2    Zaupa, A.3    Silvestri, V.4    Fiore, G.B.5    Redaelli, A.6
  • 42
    • 77955560669 scopus 로고    scopus 로고
    • Device Thrombogenicity Emulator (DTE)-design optimization methodology for cardiovascular devices: A study in two bileaflet MHV designs
    • 10.1016/j.jbiomech.2010.04.020
    • Xenos M, Girdhar G, Alemu Y, Jesty J, Slepian M, Einav S, Bluestein D (2010) Device Thrombogenicity Emulator (DTE)-design optimization methodology for cardiovascular devices: a study in two bileaflet MHV designs. J Biomech 43(12): 2400-2409. doi: 10.1016/j.jbiomech.2010.04.020
    • (2010) J Biomech , vol.43 , Issue.12 , pp. 2400-2409
    • Xenos, M.1    Girdhar, G.2    Alemu, Y.3    Jesty, J.4    Slepian, M.5    Einav, S.6    Bluestein, D.7
  • 43
    • 77952011367 scopus 로고    scopus 로고
    • Particle-based methods for multiscale modeling of blood flow in the circulation and in devices: Challenges and future directions. Sixth International Bio-Fluid Mechanics Symposium and Workshop March 28-30, 2008 Pasadena, California
    • Yamaguchi T, Ishikawa T, Imai Y, Matsuki N, Xenos M, Deng Y, Bluestein D (2010) Particle-based methods for multiscale modeling of blood flow in the circulation and in devices: challenges and future directions. Sixth International Bio-Fluid Mechanics Symposium and Workshop March 28-30, 2008 Pasadena, California. Ann Biomed Eng 38(3): 1225-1235
    • (2010) Ann Biomed Eng , vol.38 , Issue.3 , pp. 1225-1235
    • Yamaguchi, T.1    Ishikawa, T.2    Imai, Y.3    Matsuki, N.4    Xenos, M.5    Deng, Y.6    Bluestein, D.7
  • 44
    • 33847003023 scopus 로고    scopus 로고
    • Effect of biopassive and bioactive surface-coatings on the hemocompatibility of membrane oxygenators
    • 10.1002/jbm.b.30614
    • Zimmermann AK, Weber N, Aebert H, Ziemer G, Wendel HP (2007) Effect of biopassive and bioactive surface-coatings on the hemocompatibility of membrane oxygenators. J Biomed Mater Res B Appl Biomater 80(2): 433-439. doi: 10.1002/jbm.b.30614
    • (2007) J Biomed Mater Res B Appl Biomater , vol.80 , Issue.2 , pp. 433-439
    • Zimmermann, A.K.1    Weber, N.2    Aebert, H.3    Ziemer, G.4    Wendel, H.P.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.