메뉴 건너뛰기




Volumn 34, Issue 11, 2010, Pages 930-936

Improving oxygenator performance using computational simulation and flow field-based parameters

Author keywords

Computational fluid dynamics; Inlet outlet port design; Oxygenator; Parameterization

Indexed keywords

ARTIFICIAL ORGANS; BLOOD; FLOW PATTERNS; OXYGENATION; RESIDENCE TIME DISTRIBUTION;

EID: 78649584627     PISSN: 0160564X     EISSN: 15251594     Source Type: Journal    
DOI: 10.1111/j.1525-1594.2010.01157.x     Document Type: Article
Times cited : (20)

References (12)
  • 1
    • 70949086094 scopus 로고    scopus 로고
    • Extracorporeal membrane oxygenation in adults with severe respiratory failure: a multi-center database
    • Brogan TV, Thiagarajan RR, Rycus PT, Bartlett RH, Bratton SL. Extracorporeal membrane oxygenation in adults with severe respiratory failure: a multi-center database. Intensive Care Med 2009;35:2105-14.
    • (2009) Intensive Care Med , vol.35 , pp. 2105-2114
    • Brogan, T.V.1    Thiagarajan, R.R.2    Rycus, P.T.3    Bartlett, R.H.4    Bratton, S.L.5
  • 2
    • 78649583281 scopus 로고    scopus 로고
    • Description of a flow optimized oxygenator with integrated pulsatile pump
    • Borchardt R, Schlanstein P, Arens J, et al. Description of a flow optimized oxygenator with integrated pulsatile pump. Artif Organs 2010;34:904-10.
    • (2010) Artif Organs , vol.34 , pp. 904-910
    • Borchardt, R.1    Schlanstein, P.2    Arens, J.3
  • 3
    • 4444226266 scopus 로고    scopus 로고
    • Compact intra- and extracorporeal oxygenator developments
    • Cattaneo G, Strauss A, Reul H. Compact intra- and extracorporeal oxygenator developments. Perfusion 2004;19:251-5.
    • (2004) Perfusion , vol.19 , pp. 251-255
    • Cattaneo, G.1    Strauss, A.2    Reul, H.3
  • 4
    • 78649599592 scopus 로고    scopus 로고
    • Development of computational mass and momentum transfer models for extracorporeal hollow fiber membrane oxygenators. Dissertation, University of Pittsburgh
    • Gage KL. Development of computational mass and momentum transfer models for extracorporeal hollow fiber membrane oxygenators. Dissertation, University of Pittsburgh, 2007.
    • (2007)
    • Gage, K.L.1
  • 5
    • 33746778831 scopus 로고    scopus 로고
    • Development of an implantable oxygenator with cross-flow pump
    • Asakawa Y, Funakubo A, Fukunaga K, et al. Development of an implantable oxygenator with cross-flow pump. ASAIO J 2006;52:291-5.
    • (2006) ASAIO J , vol.52 , pp. 291-295
    • Asakawa, Y.1    Funakubo, A.2    Fukunaga, K.3
  • 6
    • 67650378943 scopus 로고    scopus 로고
    • Flow uniformity in oxygenators with different outlet port design
    • Hirano A, Yamamoto K-I, Matsuda M, et al. Flow uniformity in oxygenators with different outlet port design. ASAIO J 2009;55:209-12.
    • (2009) ASAIO J , vol.55 , pp. 209-212
    • Hirano, A.1    Yamamoto, K.2    Matsuda, M.3
  • 7
    • 78649619847 scopus 로고    scopus 로고
    • Optimierung der Strömungsformen in einem Oxygenator mittels empirischer Untersuchung des Bluteinlassbereichs. Master's thesis, RWTH Aachen University
    • Dieter J. Optimierung der Strömungsformen in einem Oxygenator mittels empirischer Untersuchung des Bluteinlassbereichs. Master's thesis, RWTH Aachen University, 2008.
    • (2008)
    • Dieter, J.1
  • 8
    • 1842471932 scopus 로고    scopus 로고
    • Non-Newtonian blood flow in human right coronary arteries: steady state simulations
    • Johnston BM, Johnston PR, Corney S, Kilpatrick D. Non-Newtonian blood flow in human right coronary arteries: steady state simulations. J Biomech 2004;37:709-20.
    • (2004) J Biomech , vol.37 , pp. 709-720
    • Johnston, B.M.1    Johnston, P.R.2    Corney, S.3    Kilpatrick, D.4
  • 9
    • 0035985026 scopus 로고    scopus 로고
    • Predicting membrane oxygenator pressure drop using computational fluid dynamics
    • Gage KL, Gartner MJ, Burgreen GW, Wagner WR. Predicting membrane oxygenator pressure drop using computational fluid dynamics. Artif Organs 2002;26:600-7.
    • (2002) Artif Organs , vol.26 , pp. 600-607
    • Gage, K.L.1    Gartner, M.J.2    Burgreen, G.W.3    Wagner, W.R.4
  • 10
    • 33644971637 scopus 로고    scopus 로고
    • Uniformity of the fluid flow velocities within hollow fiber membranes of blood oxygenation devices
    • Mazaheri AR, Ahmadi G. Uniformity of the fluid flow velocities within hollow fiber membranes of blood oxygenation devices. Artif Organs 2006;30:10-5.
    • (2006) Artif Organs , vol.30 , pp. 10-15
    • Mazaheri, A.R.1    Ahmadi, G.2
  • 11
    • 0034838318 scopus 로고    scopus 로고
    • Computational fluid dynamics as a development tool for rotary blood pumps
    • Burgreen GW, Antaki JF, Wu ZJ, Holmes AJ. Computational fluid dynamics as a development tool for rotary blood pumps. Artif Organs 2001;25:336-40.
    • (2001) Artif Organs , vol.25 , pp. 336-340
    • Burgreen, G.W.1    Antaki, J.F.2    Wu, Z.J.3    Holmes, A.J.4
  • 12
    • 27744527679 scopus 로고    scopus 로고
    • A validated computational fluid dynamics model to estimate hemolysis in a rotary blood pump
    • Arvand A, Hormes M, Reul H. A validated computational fluid dynamics model to estimate hemolysis in a rotary blood pump. Artif Organs 2005;29:531-40.
    • (2005) Artif Organs , vol.29 , pp. 531-540
    • Arvand, A.1    Hormes, M.2    Reul, H.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.