메뉴 건너뛰기




Volumn 40, Issue 5, 2012, Pages 767-772

Stroke volume variation as a predictor of fluid responsiveness in patients undergoing airway pressure release ventilation

Author keywords

Airway pressure release ventilation; Stroke volume variation; Vigileo FloTrac system

Indexed keywords

RINGER LACTATE SOLUTION;

EID: 84866539303     PISSN: 0310057X     EISSN: 14480271     Source Type: Journal    
DOI: 10.1177/0310057x1204000503     Document Type: Article
Times cited : (22)

References (28)
  • 2
    • 24744434154 scopus 로고    scopus 로고
    • Assessment of fluid responsiveness in mechanically ventilated cardiac surgical patients
    • W iesenack C, Fiegl C, Keyser A, Prasser C, Keyl C. Assessment of fluid responsiveness in mechanically ventilated cardiac surgical patients. Eur J Anaesthesiol 2005; 22:658-665.
    • (2005) Eur J Anaesthesiol , vol.22 , pp. 658-665
    • Wiesenack, C.1    Fiegl, C.2    Keyser, A.3    Prasser, C.4    Keyl, C.5
  • 3
    • 20644471623 scopus 로고    scopus 로고
    • Assessment of indices of preload and volume responsiveness
    • Pinsky MR, Teboul JL. Assessment of indices of preload and volume responsiveness. Curr Opin Crit Care 2005; 11:235-239.
    • (2005) Curr Opin Crit Care , vol.11 , pp. 235-239
    • Pinsky, M.R.1    Teboul, J.L.2
  • 4
    • 23044461875 scopus 로고    scopus 로고
    • Changes in arterial pressure during mechanical ventilation
    • quiz 449-445
    • Michard F. Changes in arterial pressure during mechanical ventilation. Anesthesiology 2005; 103:419-428; quiz 449-445.
    • (2005) Anesthesiology , vol.103 , pp. 419-428
    • Michard, F.1
  • 6
    • 0037348762 scopus 로고    scopus 로고
    • Fluid responsiveness in mechanically ventilated patients: A review of indices used in intensive care
    • Bendjelid K, Romand JA. Fluid responsiveness in mechanically ventilated patients: a review of indices used in intensive care. Intensive Care Med 2003; 29:352-360.
    • (2003) Intensive Care Med , vol.29 , pp. 352-360
    • Bendjelid, K.1    Romand, J.A.2
  • 7
    • 47549096309 scopus 로고    scopus 로고
    • Does central venous pressure predict fluid responsiveness? A systematic review of the literature and the tale of seven mares
    • Marik PE, Baram M, Vahid B. Does central venous pressure predict fluid responsiveness? A systematic review of the literature and the tale of seven mares. Chest 2008; 134:172-178.
    • (2008) Chest , vol.134 , pp. 172-178
    • Marik, P.E.1    Baram, M.2    Vahid, B.3
  • 8
    • 34648831355 scopus 로고    scopus 로고
    • Uncalibrated arterial pulse contour analysis versus continuous thermodilution technique: Effects of alterations in arterial waveform
    • Lorsomradee S, Lorsomradee S, Cromheecke S, De Hert SG. Uncalibrated arterial pulse contour analysis versus continuous thermodilution technique: effects of alterations in arterial waveform. J Cardiothorac Vasc Anesth 2007; 21:636-643.
    • (2007) J Cardiothorac Vasc Anesth , vol.21 , pp. 636-643
    • Lorsomradee, S.1    Lorsomradee, S.2    Cromheecke, S.3    De Hert, S.G.4
  • 10
    • 34648816655 scopus 로고    scopus 로고
    • Cardiac output measured by a new arterial pressure waveform analysis method without calibration compared with thermodilution after cardiac surgery
    • Breukers RM, Sepehrkhouy S, Spiegelenberg SR, Groeneveld AB. Cardiac output measured by a new arterial pressure waveform analysis method without calibration compared with thermodilution after cardiac surgery. J Cardiothorac Vasc Anesth 2007; 21:632-635.
    • (2007) J Cardiothorac Vasc Anesth , vol.21 , pp. 632-635
    • Breukers, R.M.1    Sepehrkhouy, S.2    Spiegelenberg, S.R.3    Groeneveld, A.B.4
  • 11
    • 33846669409 scopus 로고    scopus 로고
    • Cardiac output determination from the arterial pressure wave: Clinical testing of a novel algorithm that does not require calibration
    • Manecke GR Jr, Auger WR. Cardiac output determination from the arterial pressure wave: clinical testing of a novel algorithm that does not require calibration. J Cardiothorac Vasc Anesth 2007; 21:3-7.
    • (2007) J Cardiothorac Vasc Anesth , vol.21 , pp. 3-7
    • Manecke Jr., G.R.1    Auger, W.R.2
  • 12
    • 70349319987 scopus 로고    scopus 로고
    • Techniques for assessment of intravascular volume in critically ill patients
    • Marik PE. Techniques for assessment of intravascular volume in critically ill patients. J Intensive Care Med 2009; 24:329-337.
    • (2009) J Intensive Care Med , vol.24 , pp. 329-337
    • Marik, P.E.1
  • 13
    • 59649123027 scopus 로고    scopus 로고
    • The ability of stroke volume variations obtained with Vigileo/FloTrac system to monitor fluid responsiveness in mechanically ventilated patients
    • Cannesson M, Musard H, Desebbe O, Boucau C, Simon R, Henaine R et al. The ability of stroke volume variations obtained with Vigileo/FloTrac system to monitor fluid responsiveness in mechanically ventilated patients. Anesth Analg 2009; 108:513-517.
    • (2009) Anesth Analg , vol.108 , pp. 513-517
    • Cannesson, M.1    Musard, H.2    Desebbe, O.3    Boucau, C.4    Simon, R.5    Henaine, R.6
  • 14
    • 0037352554 scopus 로고    scopus 로고
    • Influence of tidal volume on left ventricular stroke volume variation measured by pulse contour analysis in mechanically ventilated patients
    • Reuter DA, Bayerlein J, Goepfert MSG, Weis FC, Kilger E, Lamm P et al. Influence of tidal volume on left ventricular stroke volume variation measured by pulse contour analysis in mechanically ventilated patients. Intensive Care Med 2003;29:476-480.
    • (2003) Intensive Care Med , vol.29 , pp. 476-480
    • Reuter, D.A.1    Bayerlein, J.2    Goepfert, M.S.G.3    Weis, F.C.4    Kilger, E.5    Lamm, P.6
  • 15
    • 0034968042 scopus 로고    scopus 로고
    • Implications of arterial pressure variation in patients in the intensive care unit
    • Gunn SR, Pinsky MR. Implications of arterial pressure variation in patients in the intensive care unit. Curr Opin Crit Care 2001; 7:212-217.
    • (2001) Curr Opin Crit Care , vol.7 , pp. 212-217
    • Gunn, S.R.1    Pinsky, M.R.2
  • 16
    • 0032420373 scopus 로고    scopus 로고
    • Assessing fluid responsiveness by the systolic pressure variation in mechanically ventilated patients. Systolic pressure variation as a guide to fluid therapy in patients with sepsis-induced hypotension
    • Perel A. Assessing fluid responsiveness by the systolic pressure variation in mechanically ventilated patients. Systolic pressure variation as a guide to fluid therapy in patients with sepsis-induced hypotension. Anesthesiology 1998; 89:1309-1310.
    • (1998) Anesthesiology , vol.89 , pp. 1309-1310
    • Perel, A.1
  • 17
    • 0033797681 scopus 로고    scopus 로고
    • Using heart-lung interactions to assess fluid responsiveness during mechanical ventilation
    • Michard F, Teboul JL. Using heart-lung interactions to assess fluid responsiveness during mechanical ventilation. Crit Care 2000; 4:282-289.
    • (2000) Crit Care , vol.4 , pp. 282-289
    • Michard, F.1    Teboul, J.L.2
  • 18
    • 0028906057 scopus 로고
    • The effect of graded hemorrhage and intravascular volume replacement on systolic pressure variation in humans during mechanical and spontaneous ventilation
    • Rooke GA, Schwid HA, Shapira Y. The effect of graded hemorrhage and intravascular volume replacement on systolic pressure variation in humans during mechanical and spontaneous ventilation. Anesth Analg 1995; 80:925-932.
    • (1995) Anesth Analg , vol.80 , pp. 925-932
    • Rooke, G.A.1    Schwid, H.A.2    Shapira, Y.3
  • 19
    • 0036283553 scopus 로고    scopus 로고
    • Predicting fluid responsiveness in ICU patients: A critical analysis of the evidence
    • Michard F, Teboul JL. Predicting fluid responsiveness in ICU patients: a critical analysis of the evidence. Chest 2002; 121:2000-2008.
    • (2002) Chest , vol.121 , pp. 2000-2008
    • Michard, F.1    Teboul, J.L.2
  • 20
    • 0037407062 scopus 로고    scopus 로고
    • Stroke volume variation as an indicator of fluid responsiveness using pulse contour analysis in mechanically ventilated patients
    • W iesenack C, Prasser C, Rodig G, Keyl C. Stroke volume variation as an indicator of fluid responsiveness using pulse contour analysis in mechanically ventilated patients. Anesth Analg 2003; 96:1254-1257.
    • (2003) Anesth Analg , vol.96 , pp. 1254-1257
    • Wiesenack, C.1    Prasser, C.2    Rodig, G.3    Keyl, C.4
  • 21
    • 54549102432 scopus 로고    scopus 로고
    • Prediction of fluid responsiveness in acute respiratory distress syndrome patients ventilated with low tidal volume and high positive end-expiratory pressure
    • H uang CC, Fu JY, Hu HC, Kao KC, Chen NH , Hsieh MJ et al. Prediction of fluid responsiveness in acute respiratory distress syndrome patients ventilated with low tidal volume and high positive end-expiratory pressure. Crit Care Med 2008; 36:2810-2816.
    • (2008) Crit Care Med , vol.36 , pp. 2810-2816
    • Huang, C.C.1    Fu, J.Y.2    Hu, H.C.3    Kao, K.C.4    Chen, N.H.5    Hsieh, M.J.6
  • 22
    • 0034756403 scopus 로고    scopus 로고
    • Influence of superior vena caval zone condition on cyclic changes in right ventricular outflow during respiratory support
    • Vieillard-Baron A, Augarde R, Prin S, Page B, Beauchet A, Jardin F. Influence of superior vena caval zone condition on cyclic changes in right ventricular outflow during respiratory support. Anesthesiology 2001; 95:1083-1088.
    • (2001) Anesthesiology , vol.95 , pp. 1083-1088
    • Vieillard-Baron, A.1    Augarde, R.2    Prin, S.3    Page, B.4    Beauchet, A.5    Jardin, F.6
  • 23
    • 17444414557 scopus 로고    scopus 로고
    • Pulse pressure variations to predict fluid responsiveness: Influence of tidal volume
    • De Backer D, Heenen S, Piagnerelli M, Koch M, Vincent JL. Pulse pressure variations to predict fluid responsiveness: influence of tidal volume. Intensive Care Med 2005; 31:517-523.
    • (2005) Intensive Care Med , vol.31 , pp. 517-523
    • De Backer, D.1    Heenen, S.2    Piagnerelli, M.3    Koch, M.4    Vincent, J.L.5
  • 24
    • 0029786702 scopus 로고    scopus 로고
    • Positive end-expiratory pressure-induced hemodynamic changes are reflected in the arterial pressure waveform
    • Pizov R, Cohen M, Weiss Y, Segal E, Cotev S, Perel A. Positive end-expiratory pressure-induced hemodynamic changes are reflected in the arterial pressure waveform. Crit Care Med 1996; 24:1381-1387.
    • (1996) Crit Care Med , vol.24 , pp. 1381-1387
    • Pizov, R.1    Cohen, M.2    Weiss, Y.3    Segal, E.4    Cotev, S.5    Perel, A.6
  • 25
    • 0034053741 scopus 로고    scopus 로고
    • Estimation of cardiac preload changes by systolic pressure variation in pigs undergoing pneumoperitoneum
    • Tournadre JP, Allaouchiche B, Cayrel V, Mathon L, Chassard D. Estimation of cardiac preload changes by systolic pressure variation in pigs undergoing pneumoperitoneum. Acta Anaesthesiol Scand 2000; 44:231-235.
    • (2000) Acta Anaesthesiol Scand , vol.44 , pp. 231-235
    • Tournadre, J.P.1    Allaouchiche, B.2    Cayrel, V.3    Mathon, L.4    Chassard, D.5
  • 26
    • 2942683043 scopus 로고    scopus 로고
    • Effects of mid-line thoracotomy on the interaction between mechanical ventilation and cardiac filling during cardiac surgery
    • Reuter DA, Goresch T, Goepfert MSG, Wildhirt SM, Kilger E, Goetz AE. Effects of mid-line thoracotomy on the interaction between mechanical ventilation and cardiac filling during cardiac surgery. Br J Anaesth 2004; 92:808-813.
    • (2004) Br J Anaesth , vol.92 , pp. 808-813
    • Reuter, D.A.1    Goresch, T.2    Goepfert, M.S.G.3    Wildhirt, S.M.4    Kilger, E.5    Goetz, A.E.6
  • 27
    • 0022148248 scopus 로고
    • Influence of lung and chest wall compliances on transmission of airway pressure to the pleural space in critically ill patients
    • Jardin F, Genevray B, Brun-Ney D, Bourdarias JP. Influence of lung and chest wall compliances on transmission of airway pressure to the pleural space in critically ill patients. Chest 1985; 88:653-658.
    • (1985) Chest , vol.88 , pp. 653-658
    • Jardin, F.1    Genevray, B.2    Brun-Ney, D.3    Bourdarias, J.P.4
  • 28
    • 33744905017 scopus 로고    scopus 로고
    • The influence of positive end-expiratory pressure on stroke volume variation and central blood volume during open and closed chest conditions
    • Kubitz JC, Annecke T, Kemming GI, Forkl S, Kronas N, Goetz AE et al. The influence of positive end-expiratory pressure on stroke volume variation and central blood volume during open and closed chest conditions. Eur J Cardiothorac Surg 2006; 30:90-95.
    • (2006) Eur J Cardiothorac Surg , vol.30 , pp. 90-95
    • Kubitz, J.C.1    Annecke, T.2    Kemming, G.I.3    Forkl, S.4    Kronas, N.5    Goetz, A.E.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.