메뉴 건너뛰기




Volumn 15, Issue 2, 2014, Pages 293-304

Examining the electro-neural interface of cochlear implant users using psychophysics, CT scans, and speech understanding

Author keywords

cochlear implants; electrode configuration; neural survival; psychophysics; speech reception; spiral ganglion cell

Indexed keywords

ADULT; AGED; ARTICLE; CELL POPULATION; CELL SURVIVAL; CLINICAL ARTICLE; COCHLEA PROSTHESIS; COMPUTER ASSISTED TOMOGRAPHY; ELECTRODE; ELECTROSTIMULATION; HUMAN; MIDDLE AGED; NERVE CELL; PATTERN RECOGNITION; PRIORITY JOURNAL; PSYCHOPHYSICS; SPEECH ANALYSIS; AUDITORY STIMULATION; AUDITORY THRESHOLD; PHYSIOLOGY; PROCEDURES; SPEECH PERCEPTION;

EID: 84897022325     PISSN: 15253961     EISSN: 14387573     Source Type: Journal    
DOI: 10.1007/s10162-013-0437-5     Document Type: Article
Times cited : (156)

References (36)
  • 1
    • 34147148014 scopus 로고    scopus 로고
    • Threshold and channel interaction in cochlear implant users: Evaluation of the tripolar electrode configuration
    • BIERER JA (2007) Threshold and channel interaction in cochlear implant users: evaluation of the tripolar electrode configuration. J Acoust Soc Am 121:1642.
    • (2007) J Acoust Soc Am , vol.121 , pp. 1642
    • Bierer, J.A.1
  • 2
    • 77955884367 scopus 로고    scopus 로고
    • Probing the electrode-neuron interface with focused cochlear implant stimulation
    • BIERER JA (2010) Probing the electrode-neuron interface with focused cochlear implant stimulation. Trends Amplif 14:84-95.
    • (2010) Trends Amplif , vol.14 , pp. 84-95
    • Bierer, J.A.1
  • 5
    • 0035038241 scopus 로고    scopus 로고
    • Psychophysics of a prototype peri-modiolar cochlear implant electrode array
    • COHEN LT, SAUNDERS E, CLARK GM (2001) Psychophysics of a prototype peri-modiolar cochlear implant electrode array. Hear Res 155:63-81
    • (2001) Hear Res , vol.155 , pp. 63-81
    • Cohen, L.T.1    Saunders, E.2    Clark, G.M.3
  • 6
    • 33746781766 scopus 로고    scopus 로고
    • Multichannel cochlear implants: Relation of histopathology to performance
    • FAYAD JN, LINTHICUM FH (2006) Multichannel cochlear implants: relation of histopathology to performance. Laryngoscope 116:1310-20.
    • (2006) Laryngoscope , vol.116 , pp. 1310-1320
    • Fayad, J.N.1    Linthicum, F.H.2
  • 7
    • 84863799796 scopus 로고    scopus 로고
    • Across-site patterns of modulation detection: Relation to speech recognition
    • GARADAT SN, ZWOLAN TA, PFINGST BE (2012) Across-site patterns of modulation detection: relation to speech recognition. J Acoust Soc Am 131:4030-41.
    • (2012) J Acoust Soc Am , vol.131 , pp. 4030-4041
    • Garadat, S.N.1    Zwolan, T.A.2    Pfingst, B.E.3
  • 8
    • 84875750582 scopus 로고    scopus 로고
    • From nucleus 24 to 513: Changing cochlear implant design affects auditory response thresholds
    • GORDON KA, PAPSIN BC (2013) From nucleus 24 to 513: changing cochlear implant design affects auditory response thresholds. Otol Neurotol 34:436-42.
    • (2013) Otol Neurotol , vol.34 , pp. 436-442
    • Gordon, K.A.1    Papsin, B.C.2
  • 11
    • 34249896416 scopus 로고    scopus 로고
    • Focused intracochlear electric stimulation with phased array channels
    • VAN DEN HONERT C, KELSALL DC (2007) Focused intracochlear electric stimulation with phased array channels. J Acoust Soc Am 121:3703-16.
    • (2007) J Acoust Soc Am , vol.121 , pp. 3703-3716
    • Van Den Honert, C.1    Kelsall, D.C.2
  • 13
    • 0031775797 scopus 로고    scopus 로고
    • Intracochlear factors contributing to psychophysical percepts following cochlear implantation
    • KAWANO A, SELDON HL, CLARK GM, RAMSDEN RT, RAINE CH (1998) Intracochlear factors contributing to psychophysical percepts following cochlear implantation. Acta Otolaryngol (Stockh) 118:313-326
    • (1998) Acta Otolaryngol (Stockh) , vol.118 , pp. 313-326
    • Kawano, A.1    Seldon, H.L.2    Clark, G.M.3    Ramsden, R.T.4    Raine, C.H.5
  • 14
    • 17244375713 scopus 로고    scopus 로고
    • Is word recognition correlated with the number of surviving spiral ganglion cells and electrode insertion depth in human subjects with cochlear implants?
    • KHAN AM, HANDZEL O, BURGESS BJ, DAMIAN D, EDDINGTON DK, NADOL JB (2005) Is word recognition correlated with the number of surviving spiral ganglion cells and electrode insertion depth in human subjects with cochlear implants? Laryngoscope 115:672-7.
    • (2005) Laryngoscope , vol.115 , pp. 672-677
    • Khan, A.M.1    Handzel, O.2    Burgess, B.J.3    Damian, D.4    Eddington, D.K.5    Nadol, J.B.6
  • 15
    • 84879478618 scopus 로고    scopus 로고
    • Chronic neurotrophin delivery promotes ectopic neurite growth from the spiral ganglion of deafened cochleae without compromising the spatial selectivity ofcochlear implants
    • doi:10.1002/cne.23318
    • LANDRY TG, FALLON JB, WISE AK, SHEPHERD RK (2013) Chronic neurotrophin delivery promotes ectopic neurite growth from the spiral ganglion of deafened cochleae without compromising the spatial selectivity ofcochlear implants. J Comp Neurol. doi:10.1002/cne.23318
    • (2013) J Comp Neurol
    • Landry, T.G.1    Fallon, J.B.2    Wise, A.K.3    Shepherd, R.K.4
  • 16
    • 84879601537 scopus 로고    scopus 로고
    • Effects of brain-derived neurotrophic factor (BDNF) and electrical stimulation on survival and function of cochlear spiral ganglion neurons in deafened, developing cats
    • LEAKE PA, STAKHOVSKAYA O, HETHERINGTON A, REBSCHER SJ, BONHAM B (2013) Effects of brain-derived neurotrophic factor (BDNF) and electrical stimulation on survival and function of cochlear spiral ganglion neurons in deafened, developing cats. J Assoc Res Otolaryngol 14:187-211.
    • (2013) J Assoc Res Otolaryngol , vol.14 , pp. 187-211
    • Leake, P.A.1    Stakhovskaya, O.2    Hetherington, A.3    Rebscher, S.J.4    Bonham, B.5
  • 17
    • 0015020347 scopus 로고
    • Transformed up-down methods in psychophysics
    • LEVITT H (1971) Transformed up-down methods in psychophysics. J Acoust Soc Am 49:467-477
    • (1971) J Acoust Soc Am , vol.49 , pp. 467-477
    • Levitt, H.1
  • 18
    • 35348821343 scopus 로고    scopus 로고
    • Analysis of intracochlear new bone and fibrous tissue formation in human subjects with cochlear implants
    • LI PM, SOMDAS MA, EDDINGTON DK, NADOL JB (2007) Analysis of intracochlear new bone and fibrous tissue formation in human subjects with cochlear implants. Ann Otol Rhinol Laryngol 116:731-8
    • (2007) Ann Otol Rhinol Laryngol , vol.116 , pp. 731-738
    • Li, P.M.1    Somdas, M.A.2    Eddington, D.K.3    Nadol, J.B.4
  • 20
    • 0024321237 scopus 로고
    • Survival of spiral ganglion cells in profound sensorineural hearing loss: Implications for cochlear implantation
    • NADOL JB, YOUNG YS, GLYNN RJ (1989) Survival of spiral ganglion cells in profound sensorineural hearing loss: implications for cochlear implantation. Ann Otol Rhinol Laryngol 98:411-6
    • (1989) Ann Otol Rhinol Laryngol , vol.98 , pp. 411-416
    • Nadol, J.B.1    Young, Y.S.2    Glynn, R.J.3
  • 22
    • 84883805335 scopus 로고    scopus 로고
    • Image-guidance enables new methods for customizing cochlear implant stimulation strategies
    • doi:10.1109/TNSRE.2013.2253333
    • NOBLE JH, LABADIE RF, GIFFORD R, DAWANT B (2013) Image-guidance enables new methods for customizing cochlear implant stimulation strategies. IEEE Trans Neural Syst Rehabil Eng. doi:10.1109/TNSRE.2013.2253333
    • (2013) IEEE Trans Neural Syst Rehabil Eng
    • Noble, J.H.1    Labadie, R.F.2    Gifford, R.3    Dawant, B.4
  • 23
    • 29244432721 scopus 로고
    • Revised CNC lists for auditory tests
    • PETERSON GE, LEHISTE I (1962) Revised CNC lists for auditory tests. J Speech Hear Dis 27:62-70
    • (1962) J Speech Hear Dis , vol.27 , pp. 62-70
    • Peterson, G.E.1    Lehiste, I.2
  • 24
    • 1542297696 scopus 로고    scopus 로고
    • Across-site variation in detection thresholds and maximum comfortable loudness levels for cochlear implants
    • PFINGST BE, XU L (2004) Across-site variation in detection thresholds and maximum comfortable loudness levels for cochlear implants. J Assoc Res Otolaryngol 5:11-24.
    • (2004) J Assoc Res Otolaryngol , vol.5 , pp. 11-24
    • Pfingst, B.E.1    Xu, L.2
  • 25
    • 8344255658 scopus 로고    scopus 로고
    • Across-site threshold variation in cochlear implants: Relation to speech recognition
    • PFINGST BE, XU L, THOMPSON CS (2004) Across-site threshold variation in cochlear implants: relation to speech recognition. Audiol Neurootol 9:341-52.
    • (2004) Audiol Neurootol , vol.9 , pp. 341-352
    • Pfingst, B.E.1    Xu, L.2    Thompson, C.S.3
  • 26
    • 0035437715 scopus 로고    scopus 로고
    • The biomedical imaging resource at Mayo Clinic
    • ROBB RA (2001) The biomedical imaging resource at Mayo Clinic. IEEE Trans Med Imaging 20:854-67.
    • (2001) IEEE Trans Med Imaging , vol.20 , pp. 854-867
    • Robb, R.A.1
  • 27
    • 23344447785 scopus 로고    scopus 로고
    • A model for cochlear implant electrode insertion and force evaluation: Results with a new electrode design and insertion technique
    • ROLAND JT (2005) A model for cochlear implant electrode insertion and force evaluation: results with a new electrode design and insertion technique. Laryngoscope 115:1325-39.
    • (2005) Laryngoscope , vol.115 , pp. 1325-1339
    • Roland, J.T.1
  • 28
    • 33748368281 scopus 로고    scopus 로고
    • Surgical aspects of cochlear implantation: Mechanisms of insertional trauma
    • ROLAND P, WRIGHT C (2006) Surgical aspects of cochlear implantation: mechanisms of insertional trauma. Adv Otorhinolaryngol 64:11-30
    • (2006) Adv Otorhinolaryngol , vol.64 , pp. 11-30
    • Roland, P.1    Wright, C.2
  • 31
    • 34247468300 scopus 로고    scopus 로고
    • Frequency map for the human cochlear spiral ganglion: Implications for cochlear implants
    • STAKHOVSKAYA O, SRIDHAR D, BONHAM BH, LEAKE PA (2007) Frequency map for the human cochlear spiral ganglion: implications for cochlear implants. J Assoc Res Otolaryngol 8:220-33.
    • (2007) J Assoc Res Otolaryngol , vol.8 , pp. 220-233
    • Stakhovskaya, O.1    Sridhar, D.2    Bonham, B.H.3    Leake, P.A.4
  • 32
    • 80051761865 scopus 로고    scopus 로고
    • Verification of computed tomographic estimates of cochlear implant array position: A micro-CT and histologic analysis
    • TEYMOURI J, HULLAR TE, HOLDEN TA, CHOLE RA (2011) Verification of computed tomographic estimates of cochlear implant array position: a micro-CT and histologic analysis. Otol Neurotol 32:980-6.
    • (2011) Otol Neurotol , vol.32 , pp. 980-986
    • Teymouri, J.1    Hullar, T.E.2    Holden, T.A.3    Chole, R.A.4
  • 33
    • 18844441395 scopus 로고    scopus 로고
    • The "pull-back" technique for Nucleus 24 perimodiolar electrode insertion
    • TODT I, BASTA D, EISENSCHENK A, ERNST A (2005) The "pull-back" technique for Nucleus 24 perimodiolar electrode insertion. Otolaryngol Head Neck Surg 132:751-4.
    • (2005) Otolaryngol Head Neck Surg , vol.132 , pp. 751-754
    • Todt, I.1    Basta, D.2    Eisenschenk, A.3    Ernst, A.4
  • 34
    • 84856194892 scopus 로고    scopus 로고
    • Assessing the placement of a cochlear electrode array by multidimensional scaling
    • VANPOUCKE F, BOERMANS P, FRIJNS J (2012) Assessing the placement of a cochlear electrode array by multidimensional scaling. IEEE Trans Biomed Eng 59:307-310
    • (2012) IEEE Trans Biomed Eng , vol.59 , pp. 307-310
    • Vanpoucke, F.1    Boermans, P.2    Frijns, J.3
  • 35
    • 0036768312 scopus 로고    scopus 로고
    • Imaging the intact guinea pig tympanic bulla by orthogonal-plane fluorescence optical sectioning microscopy
    • VOIE AH (2002) Imaging the intact guinea pig tympanic bulla by orthogonal-plane fluorescence optical sectioning microscopy. Hear Res 171:119-128
    • (2002) Hear Res , vol.171 , pp. 119-128
    • Voie, A.H.1
  • 36
    • 0031470082 scopus 로고    scopus 로고
    • Electrode discrimination and speech recognition in postlingually deafened adult cochlear implant subjects
    • ZWOLAN TA, COLLINS LM, WAKEFIELD GH (1997) Electrode discrimination and speech recognition in postlingually deafened adult cochlear implant subjects. J Acoust Soc Am 102:3673-85
    • (1997) J Acoust Soc Am , vol.102 , pp. 3673-3685
    • Zwolan, T.A.1    Collins, L.M.2    Wakefield, G.H.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.