-
1
-
-
3543118454
-
Recognition of speech presented at soft to loud levels by adult cochlear implant recipients of three cochlear implant systems
-
Firszt JB, Holden LK, Skinner MW, et al. Recognition of speech presented at soft to loud levels by adult cochlear implant recipients of three cochlear implant systems. Ear Hear 2004; 25: 375–87.
-
(2004)
Ear Hear
, vol.25
, pp. 375-387
-
-
Firszt, J.B.1
Holden, L.K.2
Skinner, M.W.3
-
2
-
-
0020645036
-
Histopathology of profound sensorineural deafness
-
Hinojosa R, Marion M. Histopathology of profound sensorineural deafness. Ann N Y Acad Sci 1983; 405: 459–84.
-
(1983)
Ann N Y Acad Sci
, vol.405
, pp. 459-484
-
-
Hinojosa, R.1
Marion, M.2
-
3
-
-
0030868270
-
Patterns of neural degeneration in the human cochlea and auditory nerve: Implications for cochlear implantation
-
Nadol JB Jr. Patterns of neural degeneration in the human cochlea and auditory nerve: Implications for cochlear implantation. Otolaryngol Head Neck Surg 1997; 117: 220–8.
-
(1997)
Otolaryngol Head Neck Surg
, vol.117
, pp. 220-228
-
-
Nadol, J.B.1
-
4
-
-
0026749553
-
Diameter of the cochlear nerve in deaf humans: Implications for cochlear implantation
-
Nadol JB Jr, Xu WZ. Diameter of the cochlear nerve in deaf humans: Implications for cochlear implantation. Ann Otol Rhinol Laryngol 1992; 101: 988–93.
-
(1992)
Ann Otol Rhinol Laryngol
, vol.101
, pp. 988-993
-
-
Nadol, J.B.1
Xu, W.Z.2
-
6
-
-
0023187806
-
Correlative study of sensory cell density and cochlear length in humans
-
Ulehlova L, Voldrich L, Janisch R. Correlative study of sensory cell density and cochlear length in humans. Hear Res 1987; 28: 149–51.
-
(1987)
Hear Res
, vol.28
, pp. 149-151
-
-
Ulehlova, L.1
Voldrich, L.2
Janisch, R.3
-
7
-
-
0014370844
-
Cellular pattern and nerve supply of the human organ of Corti
-
Stockh
-
Bredberg G. Cellular pattern and nerve supply of the human organ of Corti. Acta Otolaryngol Suppl (Stockh) 1968 (suppl 236).
-
(1968)
Acta Otolaryngol Suppl
-
-
Bredberg, G.1
-
8
-
-
33746781363
-
Two temporal bone computed tomography measurements increase recognition of malformations and predict sensorineural hearing loss
-
Purcell DD, Fischbein NJ, Patel A, Johnson J, Lalwani AK. Two temporal bone computed tomography measurements increase recognition of malformations and predict sensorineural hearing loss. Laryngoscope 2006; 116: 1439–46.
-
(2006)
Laryngoscope
, vol.116
, pp. 1439-1446
-
-
Purcell, D.D.1
Fischbein, N.J.2
Patel, A.3
Johnson, J.4
Lalwani, A.K.5
-
9
-
-
0037330126
-
Simulations of tonotopically mapped speech processors for cochlear implant electrodes varying in insertion depth
-
Faulkner A, Rosen S, Stanton D. Simulations of tonotopically mapped speech processors for cochlear implant electrodes varying in insertion depth. J Acoust Soc Am 2003; 113: 1073–80.
-
(2003)
J Acoust Soc Am
, vol.113
, pp. 1073-1080
-
-
Faulkner, A.1
Rosen, S.2
Stanton, D.3
-
10
-
-
33746482065
-
The right information may matter more than frequency-place alignment: Simulations of frequency-aligned and upward shifting cochlear implant processors for a shallow electrode array insertion
-
Faulkner A, Rosen S, Norman C. The right information may matter more than frequency-place alignment: Simulations of frequency-aligned and upward shifting cochlear implant processors for a shallow electrode array insertion. Ear Hear 2006; 27: 139–52.
-
(2006)
Ear Hear
, vol.27
, pp. 139-152
-
-
Faulkner, A.1
Rosen, S.2
Norman, C.3
-
11
-
-
0344389021
-
Recognition of spectrally degraded and frequency-shifted vowels in acoustic and electric hearing
-
Fu QJ, Shannon RV. Recognition of spectrally degraded and frequency-shifted vowels in acoustic and electric hearing. J Acoust Soc Am 1999; 105: 1889–900.
-
(1999)
J Acoust Soc Am
, vol.105
, pp. 1889-1900
-
-
Fu, Q.J.1
Shannon, R.V.2
-
12
-
-
0032806729
-
Effects of electrode configuration and frequency allocation on vowel recognition with the Nucleus-22 cochlear implant
-
Fu QJ, Shannon RV. Effects of electrode configuration and frequency allocation on vowel recognition with the Nucleus-22 cochlear implant. Ear Hear 1999; 20: 332–44.
-
(1999)
Ear Hear
, vol.20
, pp. 332-344
-
-
Fu, Q.J.1
Shannon, R.V.2
-
13
-
-
0036788457
-
Perceptual learning following changes in the frequency-to-electrode assignment with the Nucleus-22 cochlear implant
-
Fu QJ, Shannon RV, Galvin JJ III. Perceptual learning following changes in the frequency-to-electrode assignment with the Nucleus-22 cochlear implant. J Acoust Soc Am 2002; 112: 1664–74.
-
(2002)
J Acoust Soc Am
, vol.112
, pp. 1664-1674
-
-
Fu, Q.J.1
Shannon, R.V.2
Galvin, J.J.3
-
14
-
-
2942717240
-
Long-term auditory adaptation to a modified peripheral frequency map
-
Stockh
-
Svirsky MA, Silveira A, Neuburger H, Teoh SW, Suarez H. Long-term auditory adaptation to a modified peripheral frequency map. Acta Otolaryngol (Stockh) 2004; 124: 381–6.
-
(2004)
Acta Otolaryngol
, vol.124
, pp. 381-386
-
-
Svirsky, M.A.1
Silveira, A.2
Neuburger, H.3
Teoh, S.W.4
Suarez, H.5
-
15
-
-
33750366207
-
A frequency-position function for the human cochlear spiral ganglion
-
Sridhar D, Stakhovskaya O, Leake PA. A frequency-position function for the human cochlear spiral ganglion. Audiol Neurotol 2006; 11 (suppl 1):16–20.
-
(2006)
Audiol Neurotol
, vol.11
, pp. 16-20
-
-
Sridhar, D.1
Stakhovskaya, O.2
Leake, P.A.3
-
16
-
-
18644362891
-
CT-derived estimation of cochlear morphology and electrode array position in relation to word recognition in Nucleus-22 recipients
-
Skinner MW, Ketten DR, Holden LK, et al. CT-derived estimation of cochlear morphology and electrode array position in relation to word recognition in Nucleus-22 recipients. J Assoc Res Otolaryngol 2002; 3: 332–50.
-
(2002)
J Assoc Res Otolaryngol
, vol.3
, pp. 332-350
-
-
Skinner, M.W.1
Ketten, D.R.2
Holden, L.K.3
-
17
-
-
12344252040
-
Quality control after cochlear impla, nt surgery by means of rotational tomography
-
Aschendorff A, Kubalek R, Turowski B, et al. Quality control after cochlear impla, nt surgery by means of rotational tomography. Otol Neurotol 2005; 26: 34–7.
-
(2005)
Otol Neurotol
, vol.26
, pp. 34-37
-
-
Aschendorff, A.1
Kubalek, R.2
Turowski, B.3
-
18
-
-
0032925099
-
Baumgartner W Czerny C. Intracochlear position of cochlear implant electrodes
-
Stockh
-
Gstoettner W, Franz P, Hamzavi J, Plenk H Jr Baumgartner W Czerny C. Intracochlear position of cochlear implant electrodes. Acta Otolaryngol (Stockh) 1999; 119: 229–33.
-
(1999)
Acta Otolaryngol
, vol.119
, pp. 229-233
-
-
Gstoettner, W.1
Franz, P.2
Hamzavi, J.3
Plenk, H.4
-
19
-
-
0030980713
-
Cochlear implant deep electrode insertion: Extent of insertional trauma
-
Stockh
-
Gstoettner W, Plenk H Jr, Franz P, et al. Cochlear implant deep electrode insertion: Extent of insertional trauma. Acta Otolaryngol (Stockh) 1997; 117: 274–7.
-
(1997)
Acta Otolaryngol
, vol.117
, pp. 274-277
-
-
Gstoettner, W.1
Plenk, H.2
Franz, P.3
-
20
-
-
0023121862
-
Multichannel intracochlear electrodes: Mechanism of insertion trauma
-
Kennedy DW. Multichannel intracochlear electrodes: Mechanism of insertion trauma. Laryngoscope 1987; 97: 42–9.
-
(1987)
Laryngoscope
, vol.97
, pp. 42-49
-
-
Kennedy, D.W.1
-
21
-
-
0022002625
-
Banded intracochlear electrode array: Evaluation of insertion trauma in human temporal bones
-
Shepherd RK, Clark GM, Pyman BC, Webb RL. Banded intracochlear electrode array: Evaluation of insertion trauma in human temporal bones. Ann Otol Rhinol Laryngol 1985; 94: 55–9.
-
(1985)
Ann Otol Rhinol Laryngol
, vol.94
, pp. 55-59
-
-
Shepherd, R.K.1
Clark, G.M.2
Pyman, B.C.3
Webb, R.L.4
-
22
-
-
18044386764
-
A temporal bone study of insertion trauma and intracochlear position of cochlear implant electrodes. II: Comparison of Spiral Clarion and HiFocus II electrodes
-
Wardrop P, Whinney D, Rebscher SJ, Luxford W, Leake P. A temporal bone study of insertion trauma and intracochlear position of cochlear implant electrodes. II: Comparison of Spiral Clarion and HiFocus II electrodes. Hear Res 2005; 203: 68–79.
-
(2005)
Hear Res
, vol.203
, pp. 68-79
-
-
Wardrop, P.1
Whinney, D.2
Rebscher, S.J.3
Luxford, W.4
Leake, P.5
-
23
-
-
18044377967
-
A temporal bone study of insertion trauma and intracochlear position of cochlear implant electrodes
-
Comparison of Nucleus banded and Nucleus Contour electrodes
-
Wardrop P, Whinney D, Rebscher SJ, Roland JT Jr, Lux-Ford W, Leake PA. A temporal bone study of insertion trauma and intracochlear position of cochlear implant electrodes. I: Comparison of Nucleus banded and Nucleus Contour electrodes. Hear Res 2005; 203: 54–67.
-
(2005)
Hear Res
, vol.203
, Issue.1
, pp. 54-67
-
-
Wardrop, P.1
Whinney, D.2
Rebscher, S.J.3
Roland, J.T.4
Lux-Ford, W.5
Leake, P.A.6
-
25
-
-
21244472017
-
Predicting basal cochlear length for electric-acoustic stimulation
-
Adunka O, Unkelbach MH, Mack MG, Radeloff A, Gstoettner W. Predicting basal cochlear length for electric-acoustic stimulation. Arch Otolaryngol Head Neck Surg 2005; 131: 488–92.
-
(2005)
Arch Otolaryngol Head Neck Surg
, vol.131
, pp. 488-492
-
-
Adunka, O.1
Unkelbach, M.H.2
Mack, M.G.3
Radeloff, A.4
Gstoettner, W.5
-
26
-
-
14844325764
-
The influence of insertion depth on the preservation of residual hearing after cochlear implantation [in German]
-
Neumann M, Aschendorff A, Schipper J, Laszig R, Klen-Zner T. The influence of insertion depth on the preservation of residual hearing after cochlear implantation [in German]. Laryngorhinootologie 2005; 84: 113–6.
-
(2005)
Laryngorhinootologie
, vol.84
, pp. 113-116
-
-
Neumann, M.1
Aschendorff, A.2
Schipper, J.3
Laszig, R.4
Klen-Zner, T.5
-
27
-
-
0032747977
-
Electric-acoustic stimulation of the auditory system. New technology for severe hearing loss
-
von Ilberg C, Kiefer J, Tillein J, et al. Electric-acoustic stimulation of the auditory system. New technology for severe hearing loss. ORL J Otorhinolaryngol Relat Spec 1999; 61: 334–40.
-
(1999)
ORL J Otorhinolaryngol Relat Spec
, vol.61
, pp. 334-340
-
-
von Ilberg, C.1
Kiefer, J.2
Tillein, J.3
-
28
-
-
0141752840
-
Combining acoustic and electrical hearing
-
Gantz BJ, Turner CW. Combining acoustic and electrical hearing. Laryngoscope 2003; 113: 1726–30.
-
(2003)
Laryngoscope
, vol.113
, pp. 1726-1730
-
-
Gantz, B.J.1
Turner, C.W.2
-
29
-
-
18044393419
-
Preservation of hearing in cochlear implant surgery: Advantages of combined electrical and acoustical speech processing
-
Gantz BJ, Turner C, Gfeller KE, Lowder MW. Preservation of hearing in cochlear implant surgery: Advantages of combined electrical and acoustical speech processing. Laryngoscope 2005; 115: 796–802.
-
(2005)
Laryngoscope
, vol.115
, pp. 796-802
-
-
Gantz, B.J.1
Turner, C.2
Gfeller, K.E.3
Lowder, M.W.4
-
30
-
-
2342455753
-
Conservation of low-frequency hearing in cochlear implantation
-
Stockh
-
Kiefer J, Gstoettner W, Baumgartner W, et al. Conservation of low-frequency hearing in cochlear implantation. Acta Otolaryngol (Stockh) 2004; 124: 272–80.
-
(2004)
Acta Otolaryngol
, vol.124
, pp. 272-280
-
-
Kiefer, J.1
Gstoettner, W.2
Baumgartner, W.3
-
31
-
-
2942739438
-
Hearing preservation in cochlear implantation for electric acoustic stimulation
-
Stockh
-
Gstoettner W, Kiefer J, Baumgartner WD, Pok S, Peters S, Adunka O. Hearing preservation in cochlear implantation for electric acoustic stimulation. Acta Otolaryngol (Stockh) 2004; 124: 348–52.
-
(2004)
Acta Otolaryngol
, vol.124
, pp. 348-352
-
-
Gstoettner, W.1
Kiefer, J.2
Baumgartner, W.D.3
Pok, S.4
Peters, S.5
Adunka, O.6
-
32
-
-
33750333181
-
The size of the cochlea and predictions of insertion depth angles for cochlear implant electrodes
-
Escudé B, James C, Deguine O, Cochard N, Eter E, Fraysse B. The size of the cochlea and predictions of insertion depth angles for cochlear implant electrodes. Audiol Neurotol 2006; 11 (suppl 1):27–33.
-
(2006)
Audiol Neurotol
, vol.11
, pp. 27-33
-
-
Escudé, B.1
James, C.2
Deguine, O.3
Cochard, N.4
Eter, E.5
Fraysse, B.6
-
33
-
-
0027503532
-
Electrical stimulation of the auditory nerve: The effect of electrode position on neural excitation
-
Shepherd RK, Hatsushika S, Clark GM. Electrical stimulation of the auditory nerve: The effect of electrode position on neural excitation. Hear Res 1993; 66: 108–20.
-
(1993)
Hear Res
, vol.66
, pp. 108-120
-
-
Shepherd, R.K.1
Hatsushika, S.2
Clark, G.M.3
-
34
-
-
0028961694
-
Cochlear pathology following reimplantation of a multichannel scala tympani electrode array in the macaque
-
Shepherd RK, Clark GM, Xu SA, Pyman BC. Cochlear pathology following reimplantation of a multichannel scala tympani electrode array in the macaque. Am J Otol 1995; 16: 186–99.
-
(1995)
Am J Otol
, vol.16
, pp. 186-199
-
-
Shepherd, R.K.1
Clark, G.M.2
Xu, S.A.3
Pyman, B.C.4
-
35
-
-
0034107793
-
Comparison of electrode position in the human cochlea using various peri-modiolar electrode arrays
-
Tykocinski M, Cohen LT, Pyman BC, et al. Comparison of electrode position in the human cochlea using various peri-modiolar electrode arrays. Am J Otol 2000; 21: 205–11.
-
(2000)
Am J Otol
, vol.21
, pp. 205-211
-
-
Tykocinski, M.1
Cohen, L.T.2
Pyman, B.C.3
-
36
-
-
0035039576
-
The effect of electrode configuration and duration of deafness on threshold and selectivity of responses to intracochlear electrical stimulation
-
Rebscher SJ, Snyder RL, Leake PA. The effect of electrode configuration and duration of deafness on threshold and selectivity of responses to intracochlear electrical stimulation. J Acoust Soc Am 2001; 109: 2035–48.
-
(2001)
J Acoust Soc Am
, vol.109
, pp. 2035-2048
-
-
Rebscher, S.J.1
Snyder, R.L.2
Leake, P.A.3
-
37
-
-
4944241801
-
Topographic spread of inferior colliculus activation in response to acoustic and intracochlear electric stimulation
-
Snyder RL, Bierer JA, Middlebrooks JC. Topographic spread of inferior colliculus activation in response to acoustic and intracochlear electric stimulation. J Assoc Res Otolaryngol 2004; 5: 305–22.
-
(2004)
J Assoc Res Otolaryngol
, vol.5
, pp. 305-322
-
-
Snyder, R.L.1
Bierer, J.A.2
Middlebrooks, J.C.3
-
38
-
-
0036089177
-
Auditory cortical images of cochlear-implant stimuli: Dependence on electrode configuration
-
Bierer JA, Middlebrooks JC. Auditory cortical images of cochlear-implant stimuli: Dependence on electrode configuration. J Neurophysiol 2002; 87: 478–92.
-
(2002)
J Neurophysiol
, vol.87
, pp. 478-492
-
-
Bierer, J.A.1
Middlebrooks, J.C.2
-
39
-
-
33846836289
-
Electro-anatomical models of the cochlear implant [Dissertation]
-
Boston, Mass: Massachusetts Institute of Technology
-
Whiten DM. Electro-anatomical models of the cochlear implant [Dissertation]. Boston, Mass: Massachusetts Institute of Technology, 2007.
-
(2007)
-
-
Whiten, D.M.1
-
40
-
-
0025126556
-
A cochlear frequency-position function for several species — 29 years later
-
Greenwood DD. A cochlear frequency-position function for several species — 29 years later. J Acoust Soc Am 1990; 87: 2592–605.
-
(1990)
J Acoust Soc Am
, vol.87
, pp. 2592-2605
-
-
Greenwood, D.D.1
-
41
-
-
0027236682
-
Radiologic evaluation of multichannel intracochlear implant insertion depth
-
Marsh MA, Xu J, Blamey PJ, et al. Radiologic evaluation of multichannel intracochlear implant insertion depth. Am J Otol 1993; 14: 386–91.
-
(1993)
Am J Otol
, vol.14
, pp. 386-391
-
-
Marsh, M.A.1
Xu, J.2
Blamey, P.J.3
-
42
-
-
0029868754
-
Improved and simplified methods for specifying positions of the electrode bands of a cochlear implant array
-
Cohen LT, Xu J, Xu SA, Clark GM. Improved and simplified methods for specifying positions of the electrode bands of a cochlear implant array. Am J Otol 1996; 17: 859–65.
-
(1996)
Am J Otol
, vol.17
, pp. 859-865
-
-
Cohen, L.T.1
Xu, J.2
Xu, S.A.3
Clark, G.M.4
-
43
-
-
0033985953
-
Cochlear view: Postoperative radiography for cochlear implantation
-
Xu J, Xu SA, Cohen LT, Clark GM. Cochlear view: Postoperative radiography for cochlear implantation. Am J Otol 2000; 21: 49–56.
-
(2000)
Am J Otol
, vol.21
, pp. 49-56
-
-
Xu, J.1
Xu, S.A.2
Cohen, L.T.3
Clark, G.M.4
-
44
-
-
0038097098
-
Evaluation of an X-ray analysis method: Comparison of electrode position estimates with information from phase contrast X-ray and histology
-
Antwerp, Belgium, 4–7 June Abstract #060
-
Cohen LT, Xu J, Tykocinski M, Saunders E, Raja D, Cowan RSC. Evaluation of an X-ray analysis method: Comparison of electrode position estimates with information from phase contrast X-ray and histology [Abstract]. In: 5th European Symposium on Paediatric Cochlear Implantation, Antwerp, Belgium, 4–7 June 2000. Abstract #060.
-
(2000)
5th European Symposium on Paediatric Cochlear Implantation
-
-
Cohen, L.T.1
Xu, J.2
Tykocinski, M.3
Saunders, E.4
Raja, D.5
Cowan, R.S.C.6
-
45
-
-
0031004726
-
Facial nerve stimulation after Nucleus 22-channel cochlear implantation
-
Kelsall DC, Shallop JK, Brammeier TG, Prenger EC. Facial nerve stimulation after Nucleus 22-channel cochlear implantation. Am J Otol 1997; 18: 336–41.
-
(1997)
Am J Otol
, vol.18
, pp. 336-341
-
-
Kelsall, D.C.1
Shallop, J.K.2
Brammeier, T.G.3
Prenger, E.C.4
-
46
-
-
0034755288
-
Cochlear implants: Three-dimensional localization by means of coregistration of CT and conventional radiographs
-
Whiting BR, Bae KT, Skinner MW. Cochlear implants: Three-dimensional localization by means of coregistration of CT and conventional radiographs. Radiology 2001; 221: 543–9.
-
(2001)
Radiology
, vol.221
, pp. 543-549
-
-
Whiting, B.R.1
Bae, K.T.2
Skinner, M.W.3
-
47
-
-
0031753048
-
In vivo measures of cochlear length and insertion depth of Nucleus cochlear implant electrode arrays
-
Ketten DR, Skinner MW, Wang G, Vannier MW, Gates GA, Neely JG. In vivo measures of cochlear length and insertion depth of Nucleus cochlear implant electrode arrays. Ann Otol Rhinol Laryngol Suppl 1998; 107 (suppl 175).
-
(1998)
Ann Otol Rhinol Laryngol Suppl
, vol.107
-
-
Ketten, D.R.1
Skinner, M.W.2
Wang, G.3
Vannier, M.W.4
Gates, G.A.5
Neely, J.G.6
-
48
-
-
0036145401
-
Nondestructive three-dimensional analysis of electrode to modiolus proximity
-
Husstedt HW, Aschendorff A, Richter B, Laszig R, Schumacher M. Nondestructive three-dimensional analysis of electrode to modiolus proximity. Otol Neurotol 2002; 23: 49–52.
-
(2002)
Otol Neurotol
, vol.23
, pp. 49-52
-
-
Husstedt, H.W.1
Aschendorff, A.2
Richter, B.3
Laszig, R.4
Schumacher, M.5
-
49
-
-
30444456222
-
Multisection CT as a valuable tool in the postoperative assessment of cochlear implant patients
-
Verbist BM, Frijns JH, Geleijns J, van Buchem MA. Multisection CT as a valuable tool in the postoperative assessment of cochlear implant patients. AJNR Am J Neuroradiol 2005; 26: 424–9.
-
(2005)
AJNR Am J Neuroradiol
, vol.26
, pp. 424-429
-
-
Verbist, B.M.1
Frijns, J.H.2
Geleijns, J.3
van Buchem, M.A.4
-
50
-
-
33748592553
-
Clinical evaluation of the Clarion CII HiFocus 1 with and without positioner
-
van der Beek FB, Boermans PP, Verbist BM, Briaire JJ, Frijns JH. Clinical evaluation of the Clarion CII HiFocus 1 with and without positioner. Ear Hear 2005; 26: 577–92.
-
(2005)
Ear Hear
, vol.26
, pp. 577-592
-
-
van der Beek, F.B.1
Boermans, P.P.2
Verbist, B.M.3
Briaire, J.J.4
Frijns, J.H.5
-
51
-
-
2942703955
-
Imaging procedures in cochlear implant patients — Evaluation of different radiological techniques
-
Stockh
-
Aschendorff A, Kubalek R, Hochmuth A, et al. Imaging procedures in cochlear implant patients — Evaluation of different radiological techniques. Acta Otolaryngol Suppl (Stockh) 2004 (suppl 552):46–9.
-
(2004)
Acta Otolaryngol Suppl
, pp. 46-49
-
-
Aschendorff, A.1
Kubalek, R.2
Hochmuth, A.3
-
52
-
-
0030071062
-
A microtomographic system for the nondestructive evaluation of bone architecture
-
Ruegsegger P, Koller B, Muller R. A microtomographic system for the nondestructive evaluation of bone architecture. Calcif Tissue Int 1996; 58: 24–9.
-
(1996)
Calcif Tissue Int
, vol.58
, pp. 24-29
-
-
Ruegsegger, P.1
Koller, B.2
Muller, R.3
-
53
-
-
0034330627
-
Multisection CT: Scanning techniques and clinical applications
-
Rydberg J, Buckwalter KA, Caldemeyer KS, et al. Multisection CT: Scanning techniques and clinical applications. Radiographics 2000; 20: 1787–806.
-
(2000)
Radiographics
, vol.20
, pp. 1787-1806
-
-
Rydberg, J.1
Buckwalter, K.A.2
Caldemeyer, K.S.3
-
54
-
-
0027270794
-
Orthogonal-plane fluorescence optical sectioning: Three-dimensional imaging of macroscopic biological specimens
-
Voie AH, Burns DH, Spelman FA. Orthogonal-plane fluorescence optical sectioning: Three-dimensional imaging of macroscopic biological specimens. J Microsc 1993; 170: 229–36.
-
(1993)
J Microsc
, vol.170
, pp. 229-236
-
-
Voie, A.H.1
Burns, D.H.2
Spelman, F.A.3
-
55
-
-
0036768312
-
Imaging the intact guinea pig tympanic bulla by orthogonal-plane fluorescence optical sectioning microscopy
-
Voie AH. Imaging the intact guinea pig tympanic bulla by orthogonal-plane fluorescence optical sectioning microscopy. Hear Res 2002; 171: 119–28.
-
(2002)
Hear Res
, vol.171
, pp. 119-128
-
-
Voie, A.H.1
-
56
-
-
0029371650
-
Three-dimensional reconstruction of the cochlea from two-dimensional images of optical sections
-
Voie AH, Spelman FA. Three-dimensional reconstruction of the cochlea from two-dimensional images of optical sections. Comput Med Imaging Graph 1995; 19: 377–84.
-
(1995)
Comput Med Imaging Graph
, vol.19
, pp. 377-384
-
-
Voie, A.H.1
Spelman, F.A.2
-
57
-
-
0029800924
-
Techniques for human temporal bone removal: Information for the scientific community
-
Nadol JB Jr. Techniques for human temporal bone removal: Information for the scientific community. Otolaryngol Head Neck Surg 1996; 115: 298–305.
-
(1996)
Otolaryngol Head Neck Surg
, vol.115
, pp. 298-305
-
-
Nadol, J.B.1
-
59
-
-
59449099584
-
HiRes 90K surgeon's manual for the HiFocus Helix and HiFocus 1j electrodes
-
Rev E Sylmar, Calif: Advanced Bionics Corporation
-
Advanced Bionics Corporation. HiRes 90K surgeon's manual for the HiFocus Helix and HiFocus 1j electrodes (Rev E). Sylmar, Calif: Advanced Bionics Corporation, 2005.
-
(2005)
-
-
-
60
-
-
0042343802
-
Risk of bacterial meningitis in children with cochlear implants
-
Reefhuis J, Honein MA, Whitney CG, et al. Risk of bacterial meningitis in children with cochlear implants. N Engl J Med 2003; 349: 435–45.
-
(2003)
N Engl J Med
, vol.349
, pp. 435-445
-
-
Reefhuis, J.1
Honein, M.A.2
Whitney, C.G.3
-
61
-
-
0035117414
-
Ad Hoc Subcommittee of the Committee on Hearing and Equilibrium of the American Academy of Otolaryngology-Head and Neck Surgery
-
Minimum speech test battery for postlingually deafened adult cochlear implant patients
-
Luxford WM; Ad Hoc Subcommittee of the Committee on Hearing and Equilibrium of the American Academy of Otolaryngology-Head and Neck Surgery. Minimum speech test battery for postlingually deafened adult cochlear implant patients. Otolaryngol Head Neck Surg 2001; 124: 125–6.
-
(2001)
Otolaryngol Head Neck Surg
, vol.124
, pp. 125-126
-
-
Luxford, W.M.1
-
62
-
-
0036775950
-
Effects of stimulation rate with the Nucleus 24 ACE speech coding strategy
-
Holden LK, Skinner MW, Holden TA, Demorest ME. Effects of stimulation rate with the Nucleus 24 ACE speech coding strategy. Ear Hear 2002; 23: 463–76.
-
(2002)
Ear Hear
, vol.23
, pp. 463-476
-
-
Holden, L.K.1
Skinner, M.W.2
Holden, T.A.3
Demorest, M.E.4
-
63
-
-
0000634903
-
The role of temporal bone imaging in cochlear implants
-
Ketten DR. The role of temporal bone imaging in cochlear implants. Curr Opin Otolaryngol Head Neck Surg 1994; 2: 401–8.
-
(1994)
Curr Opin Otolaryngol Head Neck Surg
, vol.2
, pp. 401-408
-
-
Ketten, D.R.1
-
64
-
-
34247513282
-
Three dimensional analysis of the human cochlea
-
Abstract
-
Voie A. Three dimensional analysis of the human cochlea [Abstract]. ARO Abstracts 2006; 29: 119.
-
(2006)
ARO Abstracts
, vol.29
, pp. 119
-
-
Voie, A.1
-
65
-
-
0030869629
-
Rapid decalcification of temporal bones with preservation of ultrastructure
-
Madden VJ, Henson MM. Rapid decalcification of temporal bones with preservation of ultrastructure. Hear Res 1997; 111: 76–84.
-
(1997)
Hear Res
, vol.111
, pp. 76-84
-
-
Madden, V.J.1
Henson, M.M.2
-
66
-
-
0034307499
-
Immunohistochemistry and microwave decalcification of human temporal bones
-
Keithley EM, Truong T, Chandronait B, Billings PB. Immunohistochemistry and microwave decalcification of human temporal bones. Hear Res 2000; 148: 192–6.
-
(2000)
Hear Res
, vol.148
, pp. 192-196
-
-
Keithley, E.M.1
Truong, T.2
Chandronait, B.3
Billings, P.B.4
-
67
-
-
0035437715
-
The biomedical imaging resource at Mayo Clinic
-
Robb RA. The biomedical imaging resource at Mayo Clinic. IEEE Trans Med Imaging 2001; 20: 854–67.
-
(2001)
IEEE Trans Med Imaging
, vol.20
, pp. 854-867
-
-
Robb, R.A.1
-
68
-
-
0032593926
-
Novel binning method for improved accuracy and speed of volume image coregistration using normalized mutual information
-
Camp JJ, Robb RA. Novel binning method for improved accuracy and speed of volume image coregistration using normalized mutual information. Proc SPIE 1999; 3661: 24–31.
-
(1999)
Proc SPIE
, vol.3661
, pp. 24-31
-
-
Camp, J.J.1
Robb, R.A.2
-
69
-
-
0024307395
-
Computer-aided three-dimensional reconstruction: A method of measuring temporal bone structures including the length of the cochlea
-
Takagi A, Sando I. Computer-aided three-dimensional reconstruction: A method of measuring temporal bone structures including the length of the cochlea. Ann Otol Rhinol Laryngol 1989; 98: 515–22.
-
(1989)
Ann Otol Rhinol Laryngol
, vol.98
, pp. 515-522
-
-
Takagi, A.1
Sando, I.2
-
70
-
-
0029832190
-
Computer-aided three-dimensional reconstruction in human cochlear maps: Measurement of the lengths of organ of Corti, outer wall, inner wall, and Rosenthal's canal
-
Kawano A, Seldon HL, Clark GM. Computer-aided three-dimensional reconstruction in human cochlear maps: Measurement of the lengths of organ of Corti, outer wall, inner wall, and Rosenthal's canal. Ann Otol Rhinol Laryngol 1996; 105: 701–9.
-
(1996)
Ann Otol Rhinol Laryngol
, vol.105
, pp. 701-709
-
-
Kawano, A.1
Seldon, H.L.2
Clark, G.M.3
-
71
-
-
21044435316
-
Preservation of residual hearing with cochlear implantation: How and why
-
Stockh
-
James C, Albegger K, Battmer R, et al. Preservation of residual hearing with cochlear implantation: How and why. Acta Otolaryngol (Stockh) 2005; 125: 481–91.
-
(2005)
Acta Otolaryngol
, vol.125
, pp. 481-491
-
-
James, C.1
Albegger, K.2
Battmer, R.3
-
72
-
-
18744380339
-
Measurements of electrode position inside the cochlea for different cochlear implant systems
-
Stockh
-
Kós MI, Boëx C, Sigrist A, Guyot JP, Pelizzone M. Measurements of electrode position inside the cochlea for different cochlear implant systems. Acta Otolaryngol (Stockh) 2005; 125: 474–80.
-
(2005)
Acta Otolaryngol
, vol.125
, pp. 474-480
-
-
Kós, M.I.1
Boëx, C.2
Sigrist, A.3
Guyot, J.P.4
Pelizzone, M.5
-
73
-
-
33744486066
-
Acoustic to electric pitch comparisons in cochlear implant subjects with residual hearing
-
Boëx C, Baud L, Cosendai G, Sigrist A, Kos MI, Pelizzone M. Acoustic to electric pitch comparisons in cochlear implant subjects with residual hearing. J Assoc Res Otolaryngol 2006; 7: 110–24.
-
(2006)
J Assoc Res Otolaryngol
, vol.7
, pp. 110-124
-
-
Boëx, C.1
Baud, L.2
Cosendai, G.3
Sigrist, A.4
Kos, M.I.5
Pelizzone, M.6
-
74
-
-
0032854282
-
Depth and quality of electrode insertion: A radiologic and pitch scaling assessment of two cochlear implant systems
-
Chen JM, Farb R, Hanusaik L, Shipp D, Nedzelski JM. Depth and quality of electrode insertion: A radiologic and pitch scaling assessment of two cochlear implant systems. Am J Otol 1999; 20: 192–7.
-
(1999)
Am J Otol
, vol.20
, pp. 192-197
-
-
Chen, J.M.1
Farb, R.2
Hanusaik, L.3
Shipp, D.4
Nedzelski, J.M.5
-
75
-
-
33750286196
-
Combined electroacoustic stimulation in conventional candidates for cochlear implantation
-
James CJ, Fraysse B, Deguine O, et al. Combined electroacoustic stimulation in conventional candidates for cochlear implantation. Audiol Neurotol 2006; 11 (suppl 1):57–62.
-
(2006)
Audiol Neurotol
, vol.11
, pp. 57-62
-
-
James, C.J.1
Fraysse, B.2
Deguine, O.3
-
76
-
-
1842729360
-
Effects of insertion depth of cochlear implant electrodes upon speech perception
-
Yukawa K, Cohen L, Blamey P, Pyman B, Tungvachi-Rakul V, O'Leary S. Effects of insertion depth of cochlear implant electrodes upon speech perception. Audiol Neurotol 2004; 9: 163–72.
-
(2004)
Audiol Neurotol
, vol.9
, pp. 163-172
-
-
Yukawa, K.1
Cohen, L.2
Blamey, P.3
Pyman, B.4
Tungvachi-Rakul, V.5
O'Leary, S.6
|