메뉴 건너뛰기




Volumn 132, Issue 5, 2005, Pages 751-754

The "pull-back" technique for Nucleus 24 perimodiolar electrode insertion

Author keywords

[No Author keywords available]

Indexed keywords

ARTICLE; CLINICAL ARTICLE; COCHLEA PROSTHESIS; ELECTRODE; FEMALE; HUMAN; IMPEDANCE; INTRAOPERATIVE PERIOD; MALE; NERVE POTENTIAL; POSTOPERATIVE PERIOD; PROSPECTIVE STUDY; STIMULUS RESPONSE; TELEMETRY; X RAY;

EID: 18844441395     PISSN: 01945998     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.otohns.2005.01.046     Document Type: Article
Times cited : (20)

References (13)
  • 1
    • 0023121862 scopus 로고
    • Multichannel intracochlear electrodes: Mechanisms of insertion trauma
    • D.W. Kennedy Multichannel intracochlear electrodes mechanisms of insertion trauma Laryngoscope 97 1987 42 49
    • (1987) Laryngoscope , vol.97 , pp. 42-49
    • Kennedy, D.W.1
  • 2
    • 0036189781 scopus 로고    scopus 로고
    • Threshold, comfortable level and impedance changes as a function of electrode-modiolar distance
    • E. Saunders, L. Cohen, A. Aschendorff Threshold, comfortable level and impedance changes as a function of electrode-modiolar distance Ear Hearing 23 2002 28 40
    • (2002) Ear Hearing , vol.23 , pp. 28-40
    • Saunders, E.1    Cohen, L.2    Aschendorff, A.3
  • 3
    • 0345579405 scopus 로고    scopus 로고
    • 1st ed AIP Press, Springer New York
    • G. Clark Cochlear implants 1st ed 2003 AIP Press, Springer New York 526- 36
    • (2003) Cochlear Implants
    • Clark, G.1
  • 4
    • 0035186039 scopus 로고    scopus 로고
    • Adult cochlear implant patient performance with evolving electrode technology
    • T. Zwolan, P.R. Kileny, S. Smith Adult cochlear implant patient performance with evolving electrode technology Otol Neurootol 22 2001 844 849
    • (2001) Otol Neurootol , vol.22 , pp. 844-849
    • Zwolan, T.1    Kileny, P.R.2    Smith, S.3
  • 5
    • 1842729360 scopus 로고    scopus 로고
    • Effects of insertion depth of cochlear implant electrodes upon speech perception
    • K. Yukawa, L. Cohen, P. Blamey Effects of insertion depth of cochlear implant electrodes upon speech perception Audiol Neurootol 9 2004 163 172
    • (2004) Audiol Neurootol , vol.9 , pp. 163-172
    • Yukawa, K.1    Cohen, L.2    Blamey, P.3
  • 6
    • 0034107793 scopus 로고    scopus 로고
    • Comparison of electrode position in the human cochlea using various perimodiolar electrode arrays
    • M. Tykocinski, L.T. Cohen, B.C. Pyman Comparison of electrode position in the human cochlea using various perimodiolar electrode arrays Am J Otol 21 2000 205 211
    • (2000) Am J Otol , vol.21 , pp. 205-211
    • Tykocinski, M.1    Cohen, L.T.2    Pyman, B.C.3
  • 7
    • 0035056046 scopus 로고    scopus 로고
    • Perimodiolar electrodes in cochlear implant surgery
    • W.G. Gstöttner, O. Adunka, P. Franz Perimodiolar electrodes in cochlear implant surgery Acta Otolaryngol 121 2001 216 219
    • (2001) Acta Otolaryngol , vol.121 , pp. 216-219
    • Gstöttner, W.G.1    Adunka, O.2    Franz, P.3
  • 8
    • 0037336982 scopus 로고    scopus 로고
    • Comparative study of cochlear damage with three perimodiolar electrode designs
    • A.A. Eshraghi, N.W. Yang, T.J. Balkany Comparative study of cochlear damage with three perimodiolar electrode designs Laryngoscope 113 3 2003 415 419
    • (2003) Laryngoscope , vol.113 , Issue.3 , pp. 415-419
    • Eshraghi, A.A.1    Yang, N.W.2    Balkany, T.J.3
  • 9
    • 0033761913 scopus 로고    scopus 로고
    • A simple two-component model of electrically evoked compound action potential in the human cochlea
    • W.K. Lai, N. Dillier A simple two-component model of electrically evoked compound action potential in the human cochlea Audiol Neurootol 5 6 2000 333 345
    • (2000) Audiol Neurootol , vol.5 , Issue.6 , pp. 333-345
    • Lai, W.K.1    Dillier, N.2
  • 10
    • 0038299943 scopus 로고    scopus 로고
    • Spatial spread of neural excitation in cochlear implant recipients: Comparision of improved ECAP method and psychophysical forward masking
    • L.T. Cohen, L.M. Richardson, E. Saunders Spatial spread of neural excitation in cochlear implant recipients comparision of improved ECAP method and psychophysical forward masking Hear Res 179 2003 72 87
    • (2003) Hear Res , vol.179 , pp. 72-87
    • Cohen, L.T.1    Richardson, L.M.2    Saunders, E.3
  • 11
    • 0029868754 scopus 로고    scopus 로고
    • Improved and simplified methods for specitying positions of the electrode bands of a cochlear implant array
    • L.T. Cohen, J. Xu, S.A. Xu Improved and simplified methods for specitying positions of the electrode bands of a cochlear implant array Am J Otol 17 1996 859 865
    • (1996) Am J Otol , vol.17 , pp. 859-865
    • Cohen, L.T.1    Xu, J.2    Xu, S.A.3
  • 12
    • 0942265287 scopus 로고    scopus 로고
    • Electrophysiologic effects of placing cochlear implant electrodes in a perimodiolar position in young children
    • P.A. Wackym, J.B. Firszt, W. Gaggl Electrophysiologic effects of placing cochlear implant electrodes in a perimodiolar position in young children Laryngoscope 114 1 2004 71 76
    • (2004) Laryngoscope , vol.114 , Issue.1 , pp. 71-76
    • Wackym, P.A.1    Firszt, J.B.2    Gaggl, W.3
  • 13
    • 0025222018 scopus 로고
    • Dimensions of the scala tympani in the human and cat with reference to cochlea implants
    • S. Hatsushika, R.K. Sheperd, Y.C. Tong Dimensions of the scala tympani in the human and cat with reference to cochlea implants Ann Otolaryngol 99 1990 871 876
    • (1990) Ann Otolaryngol , vol.99 , pp. 871-876
    • Hatsushika, S.1    Sheperd, R.K.2    Tong, Y.C.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.