1
-
-
0020949243
-
Automation in coagulation testing. Clinical applications
-
Messmore H. L. Jr. Automation in coagulation testing. Clinical applications. Semin Thromb Hemost: 1983; 9 4 341 345
-
(1983)
Semin Thromb Hemost
, vol.9
, Issue.4
, pp. 341-345
-
-
Messmore Jr., H.L.1
-
2
-
-
63149161130
-
Milestones and perspectives in coagulation and hemostasis
-
Lippi G., Favaloro E. J., Franchini M., Guidi G. C. Milestones and perspectives in coagulation and hemostasis. Semin Thromb Hemost: 2009; 35 1 9 22
-
(2009)
Semin Thromb Hemost
, vol.35
, Issue.1
, pp. 9-22
-
-
Lippi, G.1
Favaloro, E.J.2
Franchini, M.3
Guidi, G.C.4
-
3
-
-
84872951853
-
Laboratory hemostasis: Milestones in clinical chemistry and laboratory medicine
-
Lippi G., Favaloro E. J. Laboratory hemostasis: milestones in clinical chemistry and laboratory medicine. Clin Chem Lab Med: 2013; 51 1 91 97
-
(2013)
Clin Chem Lab Med
, vol.51
, Issue.1
, pp. 91-97
-
-
Lippi, G.1
Favaloro, E.J.2
-
4
-
-
84875811560
-
The first 110 years of laboratory automation: Technologies, applications, and the creative scientist
-
Olsen K. The first 110 years of laboratory automation: technologies, applications, and the creative scientist. J Lab Autom: 2012; 17 6 469 480
-
(2012)
J Lab Autom
, vol.17
, Issue.6
, pp. 469-480
-
-
Olsen, K.1
-
5
-
-
84907479409
-
Total laboratory automation of routine hemostasis testing
-
doi: 10.1177/2211068213511246
-
Da Rin G., Lippi G. Total laboratory automation of routine hemostasis testing. J Lab Autom: 2013;; doi: 10.1177/2211068213511246
-
(2013)
J Lab Autom
-
-
Da Rin, G.1
Lippi, G.2
-
6
-
-
40449118414
-
Prevalence and type of pre-analytical problems for inpatients samples in coagulation laboratory
-
Salvagno G. L., Lippi G., Bassi A., Poli G., Guidi G. C. Prevalence and type of pre-analytical problems for inpatients samples in coagulation laboratory. J Eval Clin Pract: 2008; 14 2 351 353
-
(2008)
J Eval Clin Pract
, vol.14
, Issue.2
, pp. 351-353
-
-
Salvagno, G.L.1
Lippi, G.2
Bassi, A.3
Poli, G.4
Guidi, G.C.5
-
7
-
-
58149099650
-
Preanalytical and postanalytical variables: The leading causes of diagnostic error in hemostasis
-
Favaloro E. J., Lippi G., Adcock D. M. Preanalytical and postanalytical variables: the leading causes of diagnostic error in hemostasis? Semin Thromb Hemost: 2008; 34 7 612 634
-
(2008)
Semin Thromb Hemost
, vol.34
, Issue.7
, pp. 612-634
-
-
Favaloro, E.J.1
Lippi, G.2
Adcock, D.M.3
-
8
-
-
18844444286
-
High throughput coagulation analyzers review
-
Qari M. H. High throughput coagulation analyzers review. Comb Chem High Throughput Screen: 2005; 8 4 353 360
-
(2005)
Comb Chem High Throughput Screen
, vol.8
, Issue.4
, pp. 353-360
-
-
Qari, M.H.1
-
9
-
-
0028650372
-
Automation and quality control in the coagulation laboratory
-
Walenga J. M., Fareed J. Automation and quality control in the coagulation laboratory. Clin Lab Med: 1994; 14 4 709 728
-
(1994)
Clin Lab Med
, vol.14
, Issue.4
, pp. 709-728
-
-
Walenga, J.M.1
Fareed, J.2
-
10
-
-
84884211546
-
Interference in coagulation testing: Focus on spurious hemolysis, icterus, and lipemia
-
Lippi G., Plebani M., Favaloro E. J. Interference in coagulation testing: focus on spurious hemolysis, icterus, and lipemia. Semin Thromb Hemost: 2013; 39 3 258 266
-
(2013)
Semin Thromb Hemost
, vol.39
, Issue.3
, pp. 258-266
-
-
Lippi, G.1
Plebani, M.2
Favaloro, E.J.3
-
11
-
-
73349087188
-
Comparison of visual vs. Automated detection of lipemic, icteric and hemolyzed specimens: Can we rely on a human eye
-
Simundic A. M., Nikolac N., Ivankovic V., et al. Comparison of visual vs. automated detection of lipemic, icteric and hemolyzed specimens: can we rely on a human eye? Clin Chem Lab Med: 2009; 47 11 1361 1365
-
(2009)
Clin Chem Lab Med
, vol.47
, Issue.11
, pp. 1361-1365
-
-
Simundic, A.M.1
Nikolac, N.2
Ivankovic, V.3
-
12
-
-
70349492209
-
Hemolysis index: Quality indicator or criterion for sample rejection
-
Plebani M., Lippi G. Hemolysis index: quality indicator or criterion for sample rejection? Clin Chem Lab Med: 2009; 47 8 899 902
-
(2009)
Clin Chem Lab Med
, vol.47
, Issue.8
, pp. 899-902
-
-
Plebani, M.1
Lippi, G.2
-
13
-
-
0026604380
-
Methods for measuring plasma hemoglobin in micromolar concentration compared
-
Fairbanks V. F., Ziesmer S. C., O'Brien P. C. Methods for measuring plasma hemoglobin in micromolar concentration compared. Clin Chem: 1992; 38 1 132 140
-
(1992)
Clin Chem
, vol.38
, Issue.1
, pp. 132-140
-
-
Fairbanks, V.F.1
Ziesmer, S.C.2
O'Brien, P.C.3
-
14
-
-
0031474786
-
Plasma hemoglobin measurement techniques for the in vitro evaluation of blood damage caused by medical devices
-
Malinauskas R. A. Plasma hemoglobin measurement techniques for the in vitro evaluation of blood damage caused by medical devices. Artif Organs: 1997; 21 12 1255 1267
-
(1997)
Artif Organs
, vol.21
, Issue.12
, pp. 1255-1267
-
-
Malinauskas, R.A.1
-
15
-
-
0021981533
-
Quantitative measurement of plasma hemoglobin by second derivative spectrophotometry
-
Sanderink G. J., van Rijn H. J. Quantitative measurement of plasma hemoglobin by second derivative spectrophotometry. Clin Chim Acta: 1985; 146 1 65 73
-
(1985)
Clin Chim Acta
, vol.146
, Issue.1
, pp. 65-73
-
-
Sanderink, G.J.1
Van Rijn, H.J.2
-
16
-
-
0002427925
-
A method for determination of hemoglobin in plasma by near-ultraviolet spectrophotometry
-
Harboe M. A method for determination of hemoglobin in plasma by near-ultraviolet spectrophotometry. Scand J Clin Lab Invest: 1959; 11 66 70
-
(1959)
Scand J Clin Lab Invest
, vol.11
, pp. 66-70
-
-
Harboe, M.1
-
17
-
-
82255169401
-
Evaluation of the automated coagulation analyzer Sysmex(®) CS-2100i (Siemens) [in French]
-
Martin-Toutain I., Jobic L., Mancic T., Ankri A. Evaluation of the automated coagulation analyzer Sysmex(®) CS-2100i (Siemens) [in French]. Ann Biol Clin (Paris): 2011; 69 6 699 704
-
(2011)
Ann Biol Clin (Paris)
, vol.69
, Issue.6
, pp. 699-704
-
-
Martin-Toutain, I.1
Jobic, L.2
Mancic, T.3
Ankri, A.4
-
18
-
-
80052823578
-
Pre-acquisition system assessment of the Sysmex(®) Coagulation System CS-2100i and comparison with end-user verification; A model for the regional introduction of new analysers and methods
-
Molenaar P. J., Leyte A. Pre-acquisition system assessment of the Sysmex(®) Coagulation System CS-2100i and comparison with end-user verification; a model for the regional introduction of new analysers and methods. Clin Chem Lab Med: 2011; 49 9 1479 1489
-
(2011)
Clin Chem Lab Med
, vol.49
, Issue.9
, pp. 1479-1489
-
-
Molenaar, P.J.1
Leyte, A.2
-
19
-
-
84887459288
-
Technical evaluation of the novel preanalytical module on instrumentation laboratory ACL TOP: Advancing automation in hemostasis testing
-
Lippi G., Ippolito L., Favaloro E. J. Technical evaluation of the novel preanalytical module on instrumentation laboratory ACL TOP: advancing automation in hemostasis testing. J Lab Autom: 2013; 18 5 382 390
-
(2013)
J Lab Autom
, vol.18
, Issue.5
, pp. 382-390
-
-
Lippi, G.1
Ippolito, L.2
Favaloro, E.J.3
-
20
-
-
84866100238
-
Identification of spurious hemolysis in anticoagulated blood with Sysmex XE-2100 and Siemens Advia 2120
-
Lippi G., Pipitone S., Gennari D., Franchini M. Identification of spurious hemolysis in anticoagulated blood with Sysmex XE-2100 and Siemens Advia 2120. Clin Lab: 2012; 58 7-8 801 804
-
(2012)
Clin Lab
, vol.58
, Issue.78
, pp. 801-804
-
-
Lippi, G.1
Pipitone, S.2
Gennari, D.3
Franchini, M.4
-
21
-
-
84896735510
-
Advancements in laboratory diagnostics: An invaluable tool for assessing quality of blood transfusions
-
Lippi G., Franchini M. Advancements in laboratory diagnostics: an invaluable tool for assessing quality of blood transfusions. Blood Transfus: 2012; 1-2 1 2
-
(2012)
Blood Transfus
, vol.12
, pp. 1-2
-
-
Lippi, G.1
Franchini, M.2
-
22
-
-
34248149071
-
The role of ethylenediamine tetraacetic acid (EDTA) as in vitro anticoagulant for diagnostic purposes
-
Banfi G., Salvagno G. L., Lippi G. The role of ethylenediamine tetraacetic acid (EDTA) as in vitro anticoagulant for diagnostic purposes. Clin Chem Lab Med: 2007; 45 5 565 576
-
(2007)
Clin Chem Lab Med
, vol.45
, Issue.5
, pp. 565-576
-
-
Banfi, G.1
Salvagno, G.L.2
Lippi, G.3
-
23
-
-
22444448410
-
Influence of two different buffered sodium citrate concentrations on coagulation testing
-
Lippi G., Salvagno G. L., Montagnana M., Guidi G. C. Influence of two different buffered sodium citrate concentrations on coagulation testing. Blood Coagul Fibrinolysis: 2005; 16 5 381 383
-
(2005)
Blood Coagul Fibrinolysis
, vol.16
, Issue.5
, pp. 381-383
-
-
Lippi, G.1
Salvagno, G.L.2
Montagnana, M.3
Guidi, G.C.4
-
24
-
-
84860468068
-
Primary blood tubes mixing: Time for updated recommendations
-
Lippi G., Plebani M. Primary blood tubes mixing: time for updated recommendations. Clin Chem Lab Med: 2012; 50 4 599 600
-
(2012)
Clin Chem Lab Med
, vol.50
, Issue.4
, pp. 599-600
-
-
Lippi, G.1
Plebani, M.2
-
26
-
-
84883374677
-
Recommendations for collection of venous blood
-
Lippi G., Caputo M., Banfi G., et al. Recommendations for collection of venous blood. Biochim Clin: 2008; 32 569 577
-
(2008)
Biochim Clin
, vol.32
, pp. 569-577
-
-
Lippi, G.1
Caputo, M.2
Banfi, G.3
-
27
-
-
84865863660
-
Pre-analytical variables in coagulation testing associated with diagnostic errors in hemostasis
-
Favaloro E. J., Adcock Funk D. M., Lippi G. Pre-analytical variables in coagulation testing associated with diagnostic errors in hemostasis. Lab Med: 2012; 43 2 1 10
-
(2012)
Lab Med
, vol.43
, Issue.2
, pp. 1-10
-
-
Favaloro, E.J.1
Adcock Funk, D.M.2
Lippi, G.3
-
29
-
-
84871978272
-
Effects of vigorous mixing of blood vacuum tubes on laboratory test results
-
Lima-Oliveira G., Lippi G., Salvagno G. L., et al. Effects of vigorous mixing of blood vacuum tubes on laboratory test results. Clin Biochem: 2013; 46 3 250 254
-
(2013)
Clin Biochem
, vol.46
, Issue.3
, pp. 250-254
-
-
Lima-Oliveira, G.1
Lippi, G.2
Salvagno, G.L.3
-
30
-
-
43449123060
-
Dishomogeneous separation of citrated plasma in primary collection tubes for routine coagulation testing
-
Lippi G., Salvagno G. L., Bassi A., Montagnana M., Poli G., Guidi G. C. Dishomogeneous separation of citrated plasma in primary collection tubes for routine coagulation testing. Blood Coagul Fibrinolysis: 2008; 19 4 330 332
-
(2008)
Blood Coagul Fibrinolysis
, vol.19
, Issue.4
, pp. 330-332
-
-
Lippi, G.1
Salvagno, G.L.2
Bassi, A.3
Montagnana, M.4
Poli, G.5
Guidi, G.C.6
-
31
-
-
0033124713
-
Ergonomics in the clinical laboratory
-
Caskey C. R. Ergonomics in the clinical laboratory. Clin Lab Sci: 1999; 12 3 140 144
-
(1999)
Clin Lab Sci
, vol.12
, Issue.3
, pp. 140-144
-
-
Caskey, C.R.1
-
32
-
-
33645757592
-
Preanalytical variability: The dark side of the moon in laboratory testing
-
Lippi G., Guidi G. C., Mattiuzzi C., Plebani M. Preanalytical variability: the dark side of the moon in laboratory testing. Clin Chem Lab Med: 2006; 44 4 358 365
-
(2006)
Clin Chem Lab Med
, vol.44
, Issue.4
, pp. 358-365
-
-
Lippi, G.1
Guidi, G.C.2
Mattiuzzi, C.3
Plebani, M.4
-
33
-
-
79960272717
-
Preanalytical quality improvement: From dream to reality
-
Lippi G., Chance J. J., Church S., et al. Preanalytical quality improvement: from dream to reality. Clin Chem Lab Med: 2011; 49 7 1113 1126
-
(2011)
Clin Chem Lab Med
, vol.49
, Issue.7
, pp. 1113-1126
-
-
Lippi, G.1
Chance, J.J.2
Church, S.3
-
34
-
-
84865372924
-
Preanalytical phase-A continuous challenge for laboratory professionals
-
Simundic A. M., Lippi G. Preanalytical phase-a continuous challenge for laboratory professionals. Biochem Med (Zagreb): 2012; 22 2 145 149
-
(2012)
Biochem Med (Zagreb)
, vol.22
, Issue.2
, pp. 145-149
-
-
Simundic, A.M.1
Lippi, G.2
-
35
-
-
84873856212
-
Preanalytical quality improvement: In quality we trust
-
Lippi G., Becan-McBride K., Behúlová D., et al. Preanalytical quality improvement: in quality we trust. Clin Chem Lab Med: 2013; 51 1 229 241
-
(2013)
Clin Chem Lab Med
, vol.51
, Issue.1
, pp. 229-241
-
-
Lippi, G.1
Becan-Mcbride, K.2
Behúlová, D.3
-
36
-
-
33748924332
-
Influence of the needle bore size on platelet count and routine coagulation testing
-
Lippi G., Salvagno G. L., Montagnana M., Poli G., Guidi G. C. Influence of the needle bore size on platelet count and routine coagulation testing. Blood Coagul Fibrinolysis: 2006; 17 7 557 561
-
(2006)
Blood Coagul Fibrinolysis
, vol.17
, Issue.7
, pp. 557-561
-
-
Lippi, G.1
Salvagno, G.L.2
Montagnana, M.3
Poli, G.4
Guidi, G.C.5
-
37
-
-
20844456825
-
No influence of a butterfly device on routine coagulation assays and D-dimer measurement
-
Lippi G., Salvagno G. L., Guidi G. C. No influence of a butterfly device on routine coagulation assays and D-dimer measurement. J Thromb Haemost: 2005; 3 2 389 391
-
(2005)
J Thromb Haemost
, vol.3
, Issue.2
, pp. 389-391
-
-
Lippi, G.1
Salvagno, G.L.2
Guidi, G.C.3
-
38
-
-
7044239520
-
Effect of specimen collection on routine coagulation assays and D-dimer measurement
-
Lippi G., Guidi G. C. Effect of specimen collection on routine coagulation assays and D-dimer measurement. Clin Chem: 2004; 50 11 2150 2152
-
(2004)
Clin Chem
, vol.50
, Issue.11
, pp. 2150-2152
-
-
Lippi, G.1
Guidi, G.C.2
-
39
-
-
33748936698
-
Quality and reliability of routine coagulation testing: Can we trust that sample
-
Lippi G., Franchini M., Montagnana M., Salvagno G. L., Poli G., Guidi G. C. Quality and reliability of routine coagulation testing: can we trust that sample? Blood Coagul Fibrinolysis: 2006; 17 7 513 519
-
(2006)
Blood Coagul Fibrinolysis
, vol.17
, Issue.7
, pp. 513-519
-
-
Lippi, G.1
Franchini, M.2
Montagnana, M.3
Salvagno, G.L.4
Poli, G.5
Guidi, G.C.6
-
40
-
-
77955032343
-
Quality issues in laboratory haemostasis
-
05
-
Preston F. E., Lippi G., Favaloro E. J., Jayandharan G. R., Edison E. S., Srivastava A. Quality issues in laboratory haemostasis. Haemophilia: 2010; 16 05 93 99
-
(2010)
Haemophilia
, vol.16
, pp. 93-99
-
-
Preston, F.E.1
Lippi, G.2
Favaloro, E.J.3
Jayandharan, G.R.4
Edison, E.S.5
Srivastava, A.6
-
41
-
-
59849109926
-
Causes, consequences, detection, and prevention of identification errors in laboratory diagnostics
-
Lippi G., Blanckaert N., Bonini P., et al. Causes, consequences, detection, and prevention of identification errors in laboratory diagnostics. Clin Chem Lab Med: 2009; 47 2 143 153
-
(2009)
Clin Chem Lab Med
, vol.47
, Issue.2
, pp. 143-153
-
-
Lippi, G.1
Blanckaert, N.2
Bonini, P.3
-
42
-
-
79952620219
-
Identification errors in the blood transfusion laboratory: A still relevant issue for patient safety
-
Lippi G., Plebani M. Identification errors in the blood transfusion laboratory: a still relevant issue for patient safety. Transfus Apheresis Sci: 2011; 44 2 231 233
-
(2011)
Transfus Apheresis Sci
, vol.44
, Issue.2
, pp. 231-233
-
-
Lippi, G.1
Plebani, M.2
-
43
-
-
24044486250
-
Short-term venous stasis influences routine coagulation testing
-
Lippi G., Salvagno G. L., Montagnana M., Guidi G. C. Short-term venous stasis influences routine coagulation testing. Blood Coagul Fibrinolysis: 2005; 16 6 453 458
-
(2005)
Blood Coagul Fibrinolysis
, vol.16
, Issue.6
, pp. 453-458
-
-
Lippi, G.1
Salvagno, G.L.2
Montagnana, M.3
Guidi, G.C.4
-
44
-
-
84872151000
-
-
The Joint Commission Accessed: October 13, 2013
-
The Joint Commission National Patient Safety Goals Effective January 1, 2011. Available at: http://www.jointcommission.org/assets/1/6/NPSG-Chapter- Jan2012-OBS.pdf. Accessed: October 13, 2013
-
National Patient Safety Goals Effective January 1, 2011
-
-
-
45
-
-
67349218803
-
Pre-analytical workstations: A tool for reducing laboratory errors
-
Da Rin G. Pre-analytical workstations: a tool for reducing laboratory errors. Clin Chim Acta: 2009; 404 1 68 74
-
(2009)
Clin Chim Acta
, vol.404
, Issue.1
, pp. 68-74
-
-
Da Rin, G.1
-
46
-
-
84856521708
-
Appropriate labelling of blood collection tubes: A step ahead towards patient's safety
-
Lippi G., Sonntag O., Plebani M. Appropriate labelling of blood collection tubes: a step ahead towards patient's safety. Clin Chem Lab Med: 2011; 49 12 1921 1923
-
(2011)
Clin Chem Lab Med
, vol.49
, Issue.12
, pp. 1921-1923
-
-
Lippi, G.1
Sonntag, O.2
Plebani, M.3
-
47
-
-
84867280165
-
Impact of the phlebotomy training based on CLSI/NCCLS H03-a6 - Procedures for the collection of diagnostic blood specimens by venipuncture
-
Lima-Oliveira G., Lippi G., Salvagno G. L., Montagnana M., Picheth G., Guidi G. C. Impact of the phlebotomy training based on CLSI/NCCLS H03-a6 - procedures for the collection of diagnostic blood specimens by venipuncture. Biochem Med (Zagreb): 2012; 22 3 342 351
-
(2012)
Biochem Med (Zagreb)
, vol.22
, Issue.3
, pp. 342-351
-
-
Lima-Oliveira, G.1
Lippi, G.2
Salvagno, G.L.3
Montagnana, M.4
Picheth, G.5
Guidi, G.C.6
-
48
-
-
79956333080
-
Elimination of the venous stasis error for routine coagulation testing by transillumination
-
Lima-Oliveira G., Salvagno G. L., Lippi G., et al. Elimination of the venous stasis error for routine coagulation testing by transillumination. Clin Chim Acta: 2011; 412 15-16 1482 1484
-
(2011)
Clin Chim Acta
, vol.412
, Issue.1516
, pp. 1482-1484
-
-
Lima-Oliveira, G.1
Salvagno, G.L.2
Lippi, G.3
-
49
-
-
77954316512
-
Is laboratory medicine a dying profession? Blessed are those who have not seen and yet have believed
-
Plebani M., Lippi G. Is laboratory medicine a dying profession? Blessed are those who have not seen and yet have believed. Clin Biochem: 2010; 43 12 939 941
-
(2010)
Clin Biochem
, vol.43
, Issue.12
, pp. 939-941
-
-
Plebani, M.1
Lippi, G.2
-
50
-
-
84867781007
-
Laboratory networking and sample quality: A still relevant issue for patient safety
-
Lippi G., Simundic A. M. Laboratory networking and sample quality: a still relevant issue for patient safety. Clin Chem Lab Med: 2012; 50 10 1703 1705
-
(2012)
Clin Chem Lab Med
, vol.50
, Issue.10
, pp. 1703-1705
-
-
Lippi, G.1
Simundic, A.M.2
-
51
-
-
0019253029
-
A computer directed pneumatic tube system: Its effects on specimens
-
Pragay D. A., Fan P., Brinkley S., Chilcote M. E. A computer directed pneumatic tube system: its effects on specimens. Clin Biochem: 1980; 13 6 259 261
-
(1980)
Clin Biochem
, vol.13
, Issue.6
, pp. 259-261
-
-
Pragay, D.A.1
Fan, P.2
Brinkley, S.3
Chilcote, M.E.4
-
52
-
-
33847000181
-
Effects of a pneumatic tube system on routine and novel hematology and coagulation parameters in healthy volunteers
-
Kratz A., Salem R. O., Van Cott E. M. Effects of a pneumatic tube system on routine and novel hematology and coagulation parameters in healthy volunteers. Arch Pathol Lab Med: 2007; 131 2 293 296
-
(2007)
Arch Pathol Lab Med
, vol.131
, Issue.2
, pp. 293-296
-
-
Kratz, A.1
Salem, R.O.2
Van Cott, E.M.3
-
53
-
-
53849144983
-
Preanalytical effects of pneumatic tube transport on routine haematology, coagulation parameters, platelet function and global coagulation
-
Wallin O., Söderberg J., Grankvist K., Jonsson P. A., Hultdin J. Preanalytical effects of pneumatic tube transport on routine haematology, coagulation parameters, platelet function and global coagulation. Clin Chem Lab Med: 2008; 46 10 1443 1449
-
(2008)
Clin Chem Lab Med
, vol.46
, Issue.10
, pp. 1443-1449
-
-
Wallin, O.1
Söderberg, J.2
Grankvist, K.3
Jonsson, P.A.4
Hultdin, J.5
-
54
-
-
80051753675
-
Pneumatic tube delivery systems for patient samples: Evidence of quality and quality of evidence
-
Plebani M., Zaninotto M. Pneumatic tube delivery systems for patient samples: evidence of quality and quality of evidence. Clin Chem Lab Med: 2011; 49 8 1245 1246
-
(2011)
Clin Chem Lab Med
, vol.49
, Issue.8
, pp. 1245-1246
-
-
Plebani, M.1
Zaninotto, M.2
-
55
-
-
13244279451
-
The effect of a pneumatic tube transport system on PFA-100 trade mark closure time and whole blood platelet aggregation
-
Dyszkiewicz-Korpanty A., Quinton R., Yassine J., Sarode R. The effect of a pneumatic tube transport system on PFA-100 trade mark closure time and whole blood platelet aggregation. J Thromb Haemost: 2004; 2 2 354 356
-
(2004)
J Thromb Haemost
, vol.2
, Issue.2
, pp. 354-356
-
-
Dyszkiewicz-Korpanty, A.1
Quinton, R.2
Yassine, J.3
Sarode, R.4
-
56
-
-
70350515714
-
Pre-analytical effects of pneumatic tube transport on impedance platelet aggregometry
-
Bolliger D., Seeberger M. D., Tanaka K. A., et al. Pre-analytical effects of pneumatic tube transport on impedance platelet aggregometry. Platelets: 2009; 20 7 458 465
-
(2009)
Platelets
, vol.20
, Issue.7
, pp. 458-465
-
-
Bolliger, D.1
Seeberger, M.D.2
Tanaka, K.A.3
-
57
-
-
77950221899
-
The effect of a pneumatic tube transport system on platelet aggregation using optical aggregometry and the PFA-100
-
Hübner U., Böckel-Frohnhöfer N., Hummel B., Geisel J. The effect of a pneumatic tube transport system on platelet aggregation using optical aggregometry and the PFA-100. Clin Lab: 2010; 56 1-2 59 64
-
(2010)
Clin Lab
, vol.56
, Issue.12
, pp. 59-64
-
-
Hübner, U.1
Böckel-Frohnhöfer, N.2
Hummel, B.3
Geisel, J.4
-
58
-
-
84867753563
-
Effect of acceleration forces during transport through a pneumatic tube system on ROTEM® analysis
-
Amann G., Zehntner C., Marti F., Colucci G. Effect of acceleration forces during transport through a pneumatic tube system on ROTEM® analysis. Clin Chem Lab Med: 2012; 50 8 1335 1342
-
(2012)
Clin Chem Lab Med
, vol.50
, Issue.8
, pp. 1335-1342
-
-
Amann, G.1
Zehntner, C.2
Marti, F.3
Colucci, G.4
-
59
-
-
79960319116
-
Suitability of a transport box for blood sample shipment over a long period
-
Lippi G., Lima-Oliveira G., Nazer S. C., et al. Suitability of a transport box for blood sample shipment over a long period. Clin Biochem: 2011; 44 12 1028 1029
-
(2011)
Clin Biochem
, vol.44
, Issue.12
, pp. 1028-1029
-
-
Lippi, G.1
Lima-Oliveira, G.2
Nazer, S.C.3
-
60
-
-
84861232119
-
An integrated system for monitoring the quality of sample transportation
-
Zaninotto M., Tasinato A., Padoan A., et al. An integrated system for monitoring the quality of sample transportation. Clin Biochem: 2012; 45 9 688 690
-
(2012)
Clin Biochem
, vol.45
, Issue.9
, pp. 688-690
-
-
Zaninotto, M.1
Tasinato, A.2
Padoan, A.3
-
61
-
-
84867815439
-
Effects of sample transportation on commonly requested laboratory tests
-
Zaninotto M., Tasinato A., Padoan A., et al. Effects of sample transportation on commonly requested laboratory tests. Clin Chem Lab Med: 2012; 50 10 1755 1760
-
(2012)
Clin Chem Lab Med
, vol.50
, Issue.10
, pp. 1755-1760
-
-
Zaninotto, M.1
Tasinato, A.2
Padoan, A.3
|