메뉴 건너뛰기




Volumn 22, Issue 3, 2012, Pages 342-351

Impact of the phlebotomy training based on CLSI/NCCLS H03-A6 - procedures for the collection of diagnostic blood specimens by venipuncture

Author keywords

Blood specimen collection; CLSI documents; Extra analytical variability; Phlebotomy; Pre analytic variability; Tourniquet application time

Indexed keywords

ANTICOAGULANT AGENT;

EID: 84867280165     PISSN: 13300962     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (49)

References (69)
  • 1
    • 65649137803 scopus 로고    scopus 로고
    • Laboratory safety and the WHO World Alliance for Patient Safety
    • McCay L, Lemer C, Wu AW. Laboratory safety and the WHO World Alliance for Patient Safety. Clin Chim Acta 2009;404:6-11.
    • (2009) Clin Chim Acta , vol.404 , pp. 6-11
    • McCay, L.1    Lemer, C.2    Wu, A.W.3
  • 2
    • 43249110698 scopus 로고    scopus 로고
    • Quality improvement in laboratory medicine: Extra-analytical issues
    • Lippi G, Fostini R, Guidi GC. Quality improvement in laboratory medicine: extra-analytical issues. Clin Lab Med 2008;28:285-94.
    • (2008) Clin Lab Med , vol.28 , pp. 285-294
    • Lippi, G.1    Fostini, R.2    Guidi, G.C.3
  • 3
    • 35348827287 scopus 로고    scopus 로고
    • The laboratory and patient safety
    • Wagar EA, Yuan S. The laboratory and patient safety. Clin Lab Med 2007;27:909-30, viii-ix.
    • (2007) Clin Lab Med , vol.27
    • Wagar, E.A.1    Yuan, S.2
  • 4
    • 77953818955 scopus 로고    scopus 로고
    • Quality in laboratory diagnostics: From theory to practice
    • Lippi G, Plebani M, Simundic AM. Quality in laboratory diagnostics: from theory to practice. Biochem Med 2010;20:126-30.
    • (2010) Biochem Med , vol.20 , pp. 126-130
    • Lippi, G.1    Plebani, M.2    Simundic, A.M.3
  • 5
    • 77953821720 scopus 로고    scopus 로고
    • Overview on patient safety in healthcare and laboratory diagnostics
    • Lippi G, Simundic AM, Mattiuzzi C. Overview on patient safety in healthcare and laboratory diagnostics. Biochem Med 2010;20:131-43.
    • (2010) Biochem Med , vol.20 , pp. 131-143
    • Lippi, G.1    Simundic, A.M.2    Mattiuzzi, C.3
  • 6
    • 77953821393 scopus 로고    scopus 로고
    • Quality and diagnostic perspectives in laboratory diagnostics
    • Muller MM. Quality and diagnostic perspectives in laboratory diagnostics. Biochem Med 2010;20:144-6.
    • (2010) Biochem Med , vol.20 , pp. 144-146
    • Muller, M.M.1
  • 7
    • 67349222950 scopus 로고    scopus 로고
    • Governance of preanalytical variability: Travelling the right path to the bright side of the moon?
    • Lippi G. Governance of preanalytical variability: travelling the right path to the bright side of the moon? Clin Chim Acta 2009;404:32-6.
    • (2009) Clin Chim Acta , vol.404 , pp. 32-36
    • Lippi, G.1
  • 8
    • 34250741964 scopus 로고    scopus 로고
    • Risk management in the preanalytical phase of laboratory testing
    • Lippi G, Guidi GC. Risk management in the preanalytical phase of laboratory testing. Clin Chem Lab Med 2007;45:720-7.
    • (2007) Clin Chem Lab Med , vol.45 , pp. 720-727
    • Lippi, G.1    Guidi, G.C.2
  • 9
    • 33645757592 scopus 로고    scopus 로고
    • Preanalytical variability: The dark side of the moon in laboratory testing
    • Lippi G, Guidi GC, Mattiuzzi C, Plebani M. Preanalytical variability: the dark side of the moon in laboratory testing. Clin Chem Lab Med 2006;44:358-65.
    • (2006) Clin Chem Lab Med , vol.44 , pp. 358-365
    • Lippi, G.1    Guidi, G.C.2    Mattiuzzi, C.3    Plebani, M.4
  • 11
    • 34347402441 scopus 로고    scopus 로고
    • Errors in a stat laboratory: Types and frequencies 10 years later
    • Carraro P, Plebani M. Errors in a stat laboratory: types and frequencies 10 years later. Clin Chem 2007;53:1338-42.
    • (2007) Clin Chem , vol.53 , pp. 1338-1342
    • Carraro, P.1    Plebani, M.2
  • 12
    • 0030797124 scopus 로고    scopus 로고
    • Mistakes in a stat laboratory: Types and frequency
    • Plebani M, Carraro P. Mistakes in a stat laboratory: types and frequency. Clin Chem 1997;43:1348-51.
    • (1997) Clin Chem , vol.43 , pp. 1348-1351
    • Plebani, M.1    Carraro, P.2
  • 13
    • 77149152841 scopus 로고    scopus 로고
    • Total quality in laboratory diagnostics. It's time to think outside the box
    • Lippi G, Simundic A-M. Total quality in laboratory diagnostics. It's time to think outside the box. Biochem Med 2010;20:5-8.
    • (2010) Biochem Med , vol.20 , pp. 5-8
    • Lippi, G.1    Simundic, A-M.2
  • 14
    • 84867269244 scopus 로고    scopus 로고
    • Quality improvements in the preanalytical phase: Focus on urine specimen workflow
    • Stankovic AK, DeLauro E. Quality improvements in the preanalytical phase: focus on urine specimen workflow. MLO Med Lab Obs 2010;42:20,22,24-7.
    • (2010) MLO Med Lab Obs , vol.42
    • Stankovic, A.K.1    DeLauro, E.2
  • 15
    • 76649101418 scopus 로고    scopus 로고
    • Improving laboratory efficiencies through significant time reduction in the preanalytical phase
    • Prusa R, Doupovcova J, Warunek D, Stankovic AK. Improving laboratory efficiencies through significant time reduction in the preanalytical phase. Clin Chem Lab Med 2010;48:293-6.
    • (2010) Clin Chem Lab Med , vol.48 , pp. 293-296
    • Prusa, R.1    Doupovcova, J.2    Warunek, D.3    Stankovic, A.K.4
  • 16
    • 0036360554 scopus 로고    scopus 로고
    • The future for clinical scientists in laboratory medicine
    • Hallworth M, Hyde K, Cumming A, Peake I. The future for clinical scientists in laboratory medicine. Clin Lab Haematol 2002;24:197-204.
    • (2002) Clin Lab Haematol , vol.24 , pp. 197-204
    • Hallworth, M.1    Hyde, K.2    Cumming, A.3    Peake, I.4
  • 18
    • 79960130914 scopus 로고    scopus 로고
    • New ways to deal with known preanalytical issues: Use of transilluminator instead of tourniquet for easing vein access and eliminating stasis on clinical biochemistry
    • Lima-Oliveira G, Lippi G, Salvagno GL, Montagnana M, Mangueira C, Sumita N, et al. New ways to deal with known preanalytical issues: use of transilluminator instead of tourniquet for easing vein access and eliminating stasis on clinical biochemistry. Biochem Med 2011;21:152-9.
    • (2011) Biochem Med , vol.21 , pp. 152-159
    • Lima-Oliveira, G.1    Lippi, G.2    Salvagno, G.L.3    Montagnana, M.4    Mangueira, C.5    Sumita, N.6
  • 20
    • 79960131955 scopus 로고    scopus 로고
    • Transillumination: A new tool to eliminate the impact of venous stasis during the procedure for the collection of diagnostic blood specimens for routine haematological testing
    • Lima-Oliveira G, Lippi G, Salvagno GL, Montagnana M, Scartezini M, Guidi GC, et al. Transillumination: a new tool to eliminate the impact of venous stasis during the procedure for the collection of diagnostic blood specimens for routine haematological testing. Int J Lab Hematol 2011;33:457-62.
    • (2011) Int J Lab Hematol , vol.33 , pp. 457-462
    • Lima-Oliveira, G.1    Lippi, G.2    Salvagno, G.L.3    Montagnana, M.4    Scartezini, M.5    Guidi, G.C.6
  • 22
    • 72749105417 scopus 로고    scopus 로고
    • Incorrect guidelines for venipuncture affect the analytical results
    • Gren B. Incorrect guidelines for venipuncture affect the analytical results. Scand J Clin Lab Invest 2009;69:815-6.
    • (2009) Scand J Clin Lab Invest , vol.69 , pp. 815-816
    • Gren, B.1
  • 25
    • 78650232966 scopus 로고    scopus 로고
    • Impact of phlebotomy decision support application on sample collection errors and laboratory efficiency
    • Loh TP, Saw S, Chai V, Sethi SK. Impact of phlebotomy decision support application on sample collection errors and laboratory efficiency. Clin Chim Acta 2011;412:393-5.
    • (2011) Clin Chim Acta , vol.412 , pp. 393-395
    • Loh, T.P.1    Saw, S.2    Chai, V.3    Sethi, S.K.4
  • 26
    • 9644279422 scopus 로고    scopus 로고
    • Comparison of samples obtained from 3.2% sodium citrate glass and two 3.2% sodium citrate plastic blood collection tubes used in coagulation testing
    • Gosselin RC, Janatpour K, Larkin EC, Lee YP, Owings JT. Comparison of samples obtained from 3.2% sodium citrate glass and two 3.2% sodium citrate plastic blood collection tubes used in coagulation testing. Am J Clin Pathol 2004;122:843-8.
    • (2004) Am J Clin Pathol , vol.122 , pp. 843-848
    • Gosselin, R.C.1    Janatpour, K.2    Larkin, E.C.3    Lee, Y.P.4    Owings, J.T.5
  • 27
    • 30444433613 scopus 로고    scopus 로고
    • A comparison of glass and plastic blood collection tubes for routine and specialized coagulation assays: A comprehensive study
    • Kratz A, Stanganelli N, Van Cott EM. A comparison of glass and plastic blood collection tubes for routine and specialized coagulation assays: a comprehensive study. Arch Pathol Lab Med 2006;130:39-44.
    • (2006) Arch Pathol Lab Med , vol.130 , pp. 39-44
    • Kratz, A.1    Stanganelli, N.2    van Cott, E.M.3
  • 28
    • 22444448410 scopus 로고    scopus 로고
    • Influence of two different buffered sodium citrate concentrations on coagulation testing
    • Lippi G, Salvagno GL, Montagnana M, Guidi GC. Influence of two different buffered sodium citrate concentrations on coagulation testing. Blood Coagul Fibrinolysis 2005;16:381-3.
    • (2005) Blood Coagul Fibrinolysis , vol.16 , pp. 381-383
    • Lippi, G.1    Salvagno, G.L.2    Montagnana, M.3    Guidi, G.C.4
  • 29
    • 40449118414 scopus 로고    scopus 로고
    • Prevalence and type of pre-analytical problems for inpatients samples in coagulation laboratory
    • Salvagno GL, Lippi G, Bassi A, Poli G, Guidi GC. Prevalence and type of pre-analytical problems for inpatients samples in coagulation laboratory. J Eval Clin Pract 2008;14:351-3.
    • (2008) J Eval Clin Pract , vol.14 , pp. 351-353
    • Salvagno, G.L.1    Lippi, G.2    Bassi, A.3    Poli, G.4    Guidi, G.C.5
  • 30
    • 14544287715 scopus 로고    scopus 로고
    • Preanalytical variables and off-site blood collection: Influences on the results of the prothrombin time/international normalized ratio test and implications for monitoring of oral anticoagulant therapy
    • van Geest-Daalderop JH, Mulder AB, Boonman-de Winter LJ, Hoekstra MM, van den Besselaar AM. Preanalytical variables and off-site blood collection: influences on the results of the prothrombin time/international normalized ratio test and implications for monitoring of oral anticoagulant therapy. Clin Chem 2005;51:561-8.
    • (2005) Clin Chem , vol.51 , pp. 561-568
    • van Geest-Daalderop, J.H.1    Mulder, A.B.2    Boonman-de Winter, L.J.3    Hoekstra, M.M.4    van den Besselaar, A.M.5
  • 31
    • 0034938879 scopus 로고    scopus 로고
    • Preanalytical recommendations of the 'Groupe d'Etude sur l'Hemostase et la Thrombose' (GEHT) for venous blood testing in hemostasis laboratories
    • Polack B, Schved JF, Boneu B. Preanalytical recommendations of the 'Groupe d'Etude sur l'Hemostase et la Thrombose' (GEHT) for venous blood testing in hemostasis laboratories. Haemostasis 2001;31:61-8.
    • (2001) Haemostasis , vol.31 , pp. 61-68
    • Polack, B.1    Schved, J.F.2    Boneu, B.3
  • 32
    • 77953839835 scopus 로고    scopus 로고
    • Hemolysis detection and management of hemolyzed specimens
    • Simundic AM, Topic E, Nikolac N, Lippi G. Hemolysis detection and management of hemolyzed specimens. Biochem Med 2010;20:154-9.
    • (2010) Biochem Med , vol.20 , pp. 154-159
    • Simundic, A.M.1    Topic, E.2    Nikolac, N.3    Lippi, G.4
  • 33
    • 84857654702 scopus 로고    scopus 로고
    • Hemolysis, lipaemia and icterus in specimens for arterial blood gas analysis
    • Salvagno GL, Lippi G, Gelati M, Guidi GC. Hemolysis, lipaemia and icterus in specimens for arterial blood gas analysis. Clin Biochem 2012;45:372-3.
    • (2012) Clin Biochem , vol.45 , pp. 372-373
    • Salvagno, G.L.1    Lippi, G.2    Gelati, M.3    Guidi, G.C.4
  • 35
    • 79951706424 scopus 로고    scopus 로고
    • Effects of hemolysis interferences on routine biochemistry parameters
    • Koseoglu M, Hur A, Atay A, Cuhadar S. Effects of hemolysis interferences on routine biochemistry parameters. Biochem Med (Zagreb) 2011;21:79-85.
    • (2011) Biochem Med (Zagreb) , vol.21 , pp. 79-85
    • Koseoglu, M.1    Hur, A.2    Atay, A.3    Cuhadar, S.4
  • 36
    • 28444436955 scopus 로고    scopus 로고
    • Clinical Laboratory Standards Institute, CLSI H3-A6 document. 6th ed. Wayne, PA: Clinical Laboratory Standards Institute
    • Clinical Laboratory Standards Institute. Procedures for the collection of diagnostic blood specimens by venipuncture. CLSI H3-A6 document. 6th ed. Wayne, PA: Clinical Laboratory Standards Institute; 2007.
    • (2007) Procedures for the collection of diagnostic blood specimens by venipuncture
  • 37
    • 79952080060 scopus 로고    scopus 로고
    • The quality of the extra-analytical phase of laboratory practice in some developing European countries and Mexico-a multicentric study
    • Simundic AM, Bilic-Zulle L, Nikolac N, Supak-Smolcic V, Honovic L, Avram S, et al. The quality of the extra-analytical phase of laboratory practice in some developing European countries and Mexico-a multicentric study. Clin Chem Lab Med 2011;49:215-28.
    • (2011) Clin Chem Lab Med , vol.49 , pp. 215-228
    • Simundic, A.M.1    Bilic-Zulle, L.2    Nikolac, N.3    Supak-Smolcic, V.4    Honovic, L.5    Avram, S.6
  • 39
    • 84872430816 scopus 로고    scopus 로고
    • National System of Accreditation-Brazilian Society of Clinical Analyses, 5th ed, Brazilian Society of Clinical Analyses
    • National System of Accreditation-Brazilian Society of Clinical Analyses. Manual for accreditation of quality management system for clinical laboratories. 5th ed. http:// www.dicq.org.br/pdfs/manual_dicq_2011.pdf: Brazilian Society of Clinical Analyses; 2011.
    • (2011) Manual for accreditation of quality management system for clinical laboratories
  • 40
    • 0842343571 scopus 로고    scopus 로고
    • International Organization for Standardization, 2nd ed Geneva, Switzerland: International Organization for Standardization
    • International Organization for Standardization. Medical laboratories-Particular requirements for quality and competence ISO document 15189. 2nd ed Geneva, Switzerland: International Organization for Standardization; 2007.
    • (2007) Medical laboratories-Particular requirements for quality and competence ISO document 15189
  • 41
    • 34347401827 scopus 로고    scopus 로고
    • Laboratory errors: How to improve pre-and post-analytical phases?
    • Plebani M. Laboratory errors: how to improve pre-and post-analytical phases? Biochem Med (Zagreb) 2007;17:5-9.
    • (2007) Biochem Med (Zagreb) , vol.17 , pp. 5-9
    • Plebani, M.1
  • 42
    • 75149130955 scopus 로고    scopus 로고
    • Diagnosis and Classification of Diabetes Mellitus
    • ADA
    • ADA. Diagnosis and Classification of Diabetes Mellitus. Diabetes Care 2010;33:S62-S9.
    • (2010) Diabetes Care , vol.33
  • 44
    • 84857627791 scopus 로고    scopus 로고
    • Different in vivo reactivity profile in health care workers and patients with spina bifida to internal and external latex glove surface-derived allergen extracts
    • Peixinho CM, Tavares-Ratado P, Gabriel MF, Romeira AM, Lozoya-Ibanez C, Taborda-Barata L, et al. Different in vivo reactivity profile in health care workers and patients with spina bifida to internal and external latex glove surface-derived allergen extracts. Br J Dermatol 2012;166:518-24.
    • (2012) Br J Dermatol , vol.166 , pp. 518-524
    • Peixinho, C.M.1    Tavares-Ratado, P.2    Gabriel, M.F.3    Romeira, A.M.4    Lozoya-Ibanez, C.5    Taborda-Barata, L.6
  • 46
    • 84863022599 scopus 로고    scopus 로고
    • A case of anaphylactic shock attributed to latex allergy during gastric cancer surgery
    • Lee W, Lee JH, Park do J, Kim HH. A case of anaphylactic shock attributed to latex allergy during gastric cancer surgery. J Korean Surg Soc 2011;81 Suppl 1:S30-3.
    • (2011) J Korean Surg Soc , vol.81 , Issue.SUPPL 1
    • Lee, W.1    Lee, J.H.2    do Park, J.3    Kim, H.H.4
  • 48
    • 84861234251 scopus 로고    scopus 로고
    • Different manufacturers of syringes: A new source of variability in blood gas, acid-base balance and related laboratory test?
    • Lima-Oliveira G, Lippi G, Salvagno GL, Montagnana M, Picheth G, Guidi GC. Different manufacturers of syringes: A new source of variability in blood gas, acid-base balance and related laboratory test? Clin Biochem 2012;45:683-7.
    • (2012) Clin Biochem , vol.45 , pp. 683-687
    • Lima-Oliveira, G.1    Lippi, G.2    Salvagno, G.L.3    Montagnana, M.4    Picheth, G.5    Guidi, G.C.6
  • 53
    • 1442285364 scopus 로고    scopus 로고
    • Drawing blood with vacuum tubes
    • Rushing J. Drawing blood with vacuum tubes. Nursing 2004;34:26.
    • (2004) Nursing , vol.34 , pp. 26
    • Rushing, J.1
  • 54
    • 0030428619 scopus 로고    scopus 로고
    • The order of draw of blood specimens into additive containing tubes not affect potassium and calcium measurements
    • Majid A, Heaney DC, Padmanabhan N, Spooner R. The order of draw of blood specimens into additive containing tubes not affect potassium and calcium measurements. J Clin Pathol 1996;49:1019-20.
    • (1996) J Clin Pathol , vol.49 , pp. 1019-1020
    • Majid, A.1    Heaney, D.C.2    Padmanabhan, N.3    Spooner, R.4
  • 55
    • 17044405129 scopus 로고    scopus 로고
    • Preanalytical variability in laboratory testing: Influence of the blood drawing technique
    • Lippi G, Salvagno GL, Brocco G, Guidi GC. Preanalytical variability in laboratory testing: influence of the blood drawing technique. Clin Chem Lab Med 2005;43:319-25.
    • (2005) Clin Chem Lab Med , vol.43 , pp. 319-325
    • Lippi, G.1    Salvagno, G.L.2    Brocco, G.3    Guidi, G.C.4
  • 56
    • 17444444102 scopus 로고
    • Recommended "order of draw" for collecting blood specimens into additive-containing tubes
    • Calam RR, Cooper MH. Recommended "order of draw" for collecting blood specimens into additive-containing tubes. Clin Chem 1982;28:1399.
    • (1982) Clin Chem , vol.28 , pp. 1399
    • Calam, R.R.1    Cooper, M.H.2
  • 58
    • 84871962285 scopus 로고    scopus 로고
    • Collection, Transport, and Processing of Blood Specimens for Testing Plasma-Based Coagulation Assays and Molecular Hemostasis Assays
    • Clinical Laboratory Standards Institute, 5th ed. Wayne, PA: Clinical Laboratory Standards Institute
    • Clinical Laboratory Standards Institute. Collection, Transport, and Processing of Blood Specimens for Testing Plasma-Based Coagulation Assays and Molecular Hemostasis Assays. CLSI H21-A5 document. 5th ed. Wayne, PA: Clinical Laboratory Standards Institute; 2008.
    • (2008) CLSI H21-A5 document
  • 59
    • 67651093816 scopus 로고    scopus 로고
    • Influence of temperature and time before centrifugation of specimens for routine coagulation testing
    • Salvagno GL, Lippi G, Montagnana M, Franchini M, Poli G, Guidi GC. Influence of temperature and time before centrifugation of specimens for routine coagulation testing. Int J Lab Hematol 2009;31:462-7.
    • (2009) Int J Lab Hematol , vol.31 , pp. 462-467
    • Salvagno, G.L.1    Lippi, G.2    Montagnana, M.3    Franchini, M.4    Poli, G.5    Guidi, G.C.6
  • 62
    • 84872427246 scopus 로고    scopus 로고
    • Clinical Laboratory Standards Institute, Available at, Accessed February 16, 2012
    • Clinical Laboratory Standards Institute. Mission of Clinical and Laboratory Standards Institute. 2012; Available at: http://www.clsi.org/Content/NavigationMenu/AboutCLSI/ VisionMissionandValues/Vision_Mission_Value.htm. Accessed February 16, 2012.
    • (2012) Mission of Clinical and Laboratory Standards Institute
  • 63
    • 0025994345 scopus 로고
    • Protons in ischemia: Where do they come from; where do they go to?
    • Dennis SC, Gevers W, Opie LH. Protons in ischemia: where do they come from; where do they go to? J Mol Cell Cardiol 1991;23:1077-86.
    • (1991) J Mol Cell Cardiol , vol.23 , pp. 1077-1086
    • Dennis, S.C.1    Gevers, W.2    Opie, L.H.3
  • 67
    • 39449108716 scopus 로고    scopus 로고
    • Veinlite transillumination in the pediatric emergency department: A therapeutic interventional trial
    • Katsogridakis YL, Seshadri R, Sullivan C, Waltzman ML. Veinlite transillumination in the pediatric emergency department: a therapeutic interventional trial. Pediatr Emerg Care 2008;24:83-8.
    • (2008) Pediatr Emerg Care , vol.24 , pp. 83-88
    • Katsogridakis, Y.L.1    Seshadri, R.2    Sullivan, C.3    Waltzman, M.L.4
  • 69
    • 0031924814 scopus 로고    scopus 로고
    • Transillumination mapping prior to ambulatory phlebectomy
    • Weiss RA, Goldman MP. Transillumination mapping prior to ambulatory phlebectomy. Dermatol Surg 1998;24:447-50.
    • (1998) Dermatol Surg , vol.24 , pp. 447-450
    • Weiss, R.A.1    Goldman, M.P.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.