Volumn 50, Issue 11, 2004, Pages 2150-2152

Effect of specimen collection on routine coagulation assays and D-dimer measurement

Author keywords

[No Author keywords available]

Indexed keywords

D DIMER; FIBRINOGEN;

EID: 7044239520     PISSN: 00099147     EISSN: None     Source Type: Journal    
DOI: 10.1373/clinchem.2004.036244     Document Type: Article
Times cited : (39)

References (6)
  • 1
    • 0035065278 scopus 로고    scopus 로고
    • Effects of blood-collection systems and tubes on hematologic, chemical, and coagulation tests and on plasma hemoglobin
    • Almagor M, Lavid-Levy O. Effects of blood-collection systems and tubes on hematologic, chemical, and coagulation tests and on plasma hemoglobin. Clin Chem 2001;47:794-5.
    • (2001) Clin Chem , vol.47 , pp. 794-795
    • Almagor, M.1    Lavid-Levy, O.2
  • 2
    • 0024602002 scopus 로고
    • ARIC Hemostasis Study - I. Development of a blood collection and processing system suitable for multicenter hemostatic studies
    • Papp AC, Hatzakis H, Bracey A, Wu KK. ARIC Hemostasis Study - I. Development of a blood collection and processing system suitable for multicenter hemostatic studies. Thromb Haemost 1989;61:15-9.
    • (1989) Thromb Haemost , vol.61 , pp. 15-19
    • Papp, A.C.1    Hatzakis, H.2    Bracey, A.3    Wu, K.K.4
  • 3
    • 0030159116 scopus 로고    scopus 로고
    • Erroneous D-dimer result on a paediatric citrated specimen
    • Carroll PA, Ray MJ. Erroneous D-dimer result on a paediatric citrated specimen. Blood Coagul Fibrinolysis 1996;7:502.
    • (1996) Blood Coagul Fibrinolysis , vol.7 , pp. 502
    • Carroll, P.A.1    Ray, M.J.2
  • 4
    • 0036721423 scopus 로고    scopus 로고
    • No influence of heparin plasma and other (pre)analytic variables on D-dimer determinations
    • Schutgens RE, Haas FJ, Ruven HJ, Spannagl M, Horn K, Biesma DH. No influence of heparin plasma and other (pre)analytic variables on D-dimer determinations. Clin Chem 2002;48:1611-3.
    • (2002) Clin Chem , vol.48 , pp. 1611-1613
    • Schutgens, R.E.1    Haas, F.J.2    Ruven, H.J.3    Spannagl, M.4    Horn, K.5    Biesma, D.H.6
  • 5
    • 0030927260 scopus 로고    scopus 로고
    • A reference material for harmonisation of D-dimer assays
    • Fibrinogen Subcommittee of the Scientific and Standardization Committee of the International Society of Thrombosis and Haemostasis
    • Nieuwenhuizen W. A reference material for harmonisation of D-dimer assays. Fibrinogen Subcommittee of the Scientific and Standardization Committee of the International Society of Thrombosis and Haemostasis. Thromb Haemost 1997;77:1031-3.
    • (1997) Thromb Haemost , vol.77 , pp. 1031-1033
    • Nieuwenhuizen, W.1
  • 6
    • 0031938396 scopus 로고    scopus 로고
    • Effects of tourniquet technique, order of draw, and sample storage on plasma fibrinogen
    • Rosenson RS, Staffileno BA, Tangney CC. Effects of tourniquet technique, order of draw, and sample storage on plasma fibrinogen. Clin Chem 1998;44:688-90.
    • (1998) Clin Chem , vol.44 , pp. 688-690
    • Rosenson, R.S.1    Staffileno, B.A.2    Tangney, C.C.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.