메뉴 건너뛰기




Volumn 119, Issue , 2014, Pages 100-105

Marking wire placement for improved accuracy in thoracic spinal surgery

Author keywords

Localization; Marking wire; Radiation exposure; Spine; Thoracic; Wrong level surgery

Indexed keywords

ACCURACY; ADULT; AGED; ARTICLE; BREAST CANCER; COMPUTER ASSISTED TOMOGRAPHY; DEGENERATIVE DISEASE; EMPYEMA; EPENDYMOMA; EPIFASCIAL EMPYEMA; FEMALE; HEMANGIOBLASTOMA; HUMAN; LIPOMA; MAJOR CLINICAL STUDY; MALE; MARKING WIRE; MENINGIOMA; METASTASIS; MIDDLE AGED; NEURILEMOMA; OPERATING ROOM PERSONNEL; PATIENT COMPLIANCE; PEROPERATIVE CARE; PROSPECTIVE STUDY; RADIATION DOSE; RADIATION EXPOSURE; RETROSPECTIVE STUDY; RISK REDUCTION; SARCOMA; SPINE RADIOGRAPHY; SPINE SURGERY; SURGICAL RISK; SURGICAL WIRE; THORACIC SPINE; VERY ELDERLY; YOUNG ADULT;

EID: 84896730573     PISSN: 03038467     EISSN: 18726968     Source Type: Journal    
DOI: 10.1016/j.clineuro.2014.01.025     Document Type: Article
Times cited : (5)

References (29)
  • 1
    • 3242676907 scopus 로고    scopus 로고
    • Estimation of patient dose and associated radiogenic risks from fluoroscopically guided pedicle screw insertion
    • DOI 10.1097/01.BRS.0000131214.57597.21
    • K. Perisinakis, N. Theocharopoulos, J. Damilakis, P. Katonis, G. Papadokostakis, A. Hadjipavlou, and N. Gourtsoyiannis Estimation of patient dose and associated radiogenic risks from fluoroscopically guided pedicle screw insertion Spine 29 14 2004 1555 1560 (Pubitemid 38943840)
    • (2004) Spine , vol.29 , Issue.14 , pp. 1555-1560
    • Perisinakis, K.1    Theocharopoulos, N.2    Damilakis, J.3    Katonis, P.4    Papadokostakis, G.5    Hadjipavlou, A.6    Gourtsoyiannis, N.7
  • 3
    • 1642313677 scopus 로고    scopus 로고
    • Wrong disc space level surgery: Medicolegal implications
    • [discussion 41-42]
    • R. Goodkin, and L.L. Laska Wrong disc space level surgery: medicolegal implications Surg Neurol 61 4 2004 323 341 [discussion 41-42]
    • (2004) Surg Neurol , vol.61 , Issue.4 , pp. 323-341
    • Goodkin, R.1    Laska, L.L.2
  • 4
    • 77951768022 scopus 로고    scopus 로고
    • Avoiding wrong site surgery: A systematic review
    • J. Devine, N. Chutkan, D.C. Norvell, and J.R. Dettori Avoiding wrong site surgery: a systematic review Spine 35 9 Suppl 2010 S28 S36
    • (2010) Spine , vol.35 , Issue.9 SUPPL.
    • Devine, J.1    Chutkan, N.2    Norvell, D.C.3    Dettori, J.R.4
  • 6
    • 33749519625 scopus 로고    scopus 로고
    • Radiation exposure during pedicle screw placement in adolescent idiopathic scoliosis: Is fluoroscopy safe?
    • DOI 10.1097/01.brs.0000238675.91612.2f, PII 0000763220061001000019
    • M. Ul Haque, H.L. Shufflebarger, M. O'Brien, and A. Macagno Radiation exposure during pedicle screw placement in adolescent idiopathic scoliosis: is fluoroscopy safe? Spine 31 21 2006 2516 2520 (Pubitemid 44527037)
    • (2006) Spine , vol.31 , Issue.21 , pp. 2516-2520
    • Ul Haque, M.1    Shufflebarger, H.L.2    O'Brien, M.3    Macagno, A.4
  • 7
    • 0034218849 scopus 로고    scopus 로고
    • Current surgical management of metastatic spinal disease
    • [discussion 24, 29-30]
    • P.C. Gerszten, and W.C. Welch Current surgical management of metastatic spinal disease Oncology 14 7 2000 1013 1024 [discussion 24, 29-30]
    • (2000) Oncology , vol.14 , Issue.7 , pp. 1013-1024
    • Gerszten, P.C.1    Welch, W.C.2
  • 8
    • 46049100655 scopus 로고    scopus 로고
    • Improving accuracy and reducing errors in spinal surgery - A new technique for thoracolumbar-level localization using computer-assisted image guidance
    • A. Nowitzke, M. Wood, and K. Cooney Improving accuracy and reducing errors in spinal surgery - a new technique for thoracolumbar-level localization using computer-assisted image guidance Spine J 8 4 2008 597 604
    • (2008) Spine J , vol.8 , Issue.4 , pp. 597-604
    • Nowitzke, A.1    Wood, M.2    Cooney, K.3
  • 9
    • 84865097361 scopus 로고    scopus 로고
    • Automatic localization of vertebral levels in X-ray fluoroscopy using 3D-2D registration: A tool to reduce wrong-site surgery
    • Y. Otake, S. Schafer, J.W. Stayman, W. Zbijewski, G. Kleinszig, R. Graumann, A.J. Khanna, and J.H. Siewerdsen Automatic localization of vertebral levels in X-ray fluoroscopy using 3D-2D registration: a tool to reduce wrong-site surgery Phys Med Biol 57 17 2012 5485 5508
    • (2012) Phys Med Biol , vol.57 , Issue.17 , pp. 5485-5508
    • Otake, Y.1    Schafer, S.2    Stayman, J.W.3    Zbijewski, W.4    Kleinszig, G.5    Graumann, R.6    Khanna, A.J.7    Siewerdsen, J.H.8
  • 11
    • 84864451582 scopus 로고    scopus 로고
    • Radiation exposure to the spine surgeon in lumbar and thoracolumbar fusions with the use of an intraoperative computed tomographic 3-dimensional imaging system
    • K.G. Abdullah, F.S. Bishop, D. Lubelski, M.P. Steinmetz, E.C. Benzel, and T.E. Mroz Radiation exposure to the spine surgeon in lumbar and thoracolumbar fusions with the use of an intraoperative computed tomographic 3-dimensional imaging system Spine 37 17 2012 E1074 E1078
    • (2012) Spine , vol.37 , Issue.17
    • Abdullah, K.G.1    Bishop, F.S.2    Lubelski, D.3    Steinmetz, M.P.4    Benzel, E.C.5    Mroz, T.E.6
  • 12
    • 84859955993 scopus 로고    scopus 로고
    • Accuracy of robot-assisted placement of lumbar and sacral pedicle screws: A prospective randomized comparison to conventional freehand screw implantation
    • F. Ringel, C. Stüer, A. Reinke, A. Preuss, M. Behr, F. Auer, M. Stoffel, and B. Meyer Accuracy of robot-assisted placement of lumbar and sacral pedicle screws: a prospective randomized comparison to conventional freehand screw implantation Spine 37 8 2012 E496 E501
    • (2012) Spine , vol.37 , Issue.8
    • Ringel, F.1    Stüer, C.2    Reinke, A.3    Preuss, A.4    Behr, M.5    Auer, F.6    Stoffel, M.7    Meyer, B.8
  • 14
    • 45149096355 scopus 로고    scopus 로고
    • Intraoperative localization of thoracic spine level with preoperative percutaneous placement of intravertebral polymethylmethacrylate
    • techniques
    • W. Hsu, D.M. Sciubba, A.D. Sasson, Y. Khavkin, J.P. Wolinsky, P. Gailloud, Z.L. Gokaslan, and K. Murphy Intraoperative localization of thoracic spine level with preoperative percutaneous placement of intravertebral polymethylmethacrylate J Spinal Disord 21 1 2008 72 75 & techniques
    • (2008) J Spinal Disord , vol.21 , Issue.1 , pp. 72-75
    • Hsu, W.1    Sciubba, D.M.2    Sasson, A.D.3    Khavkin, Y.4    Wolinsky, J.P.5    Gailloud, P.6    Gokaslan, Z.L.7    Murphy, K.8
  • 15
    • 84863258490 scopus 로고    scopus 로고
    • Avoidance of wrong-level thoracic spine surgery: Intraoperative localization with preoperative percutaneous fiducial screw placement
    • C.D. Upadhyaya, J.C. Wu, C.T. Chin, G. Balamurali, and P.V. Mummaneni Avoidance of wrong-level thoracic spine surgery: intraoperative localization with preoperative percutaneous fiducial screw placement J Neurosurg Spine 16 3 2012 280 284
    • (2012) J Neurosurg Spine , vol.16 , Issue.3 , pp. 280-284
    • Upadhyaya, C.D.1    Wu, J.C.2    Chin, C.T.3    Balamurali, G.4    Mummaneni, P.V.5
  • 17
    • 60549098114 scopus 로고    scopus 로고
    • Cervical spine imaging using standard C-arm fluoroscopy: Patient and surgeon exposure to ionizing radiation
    • B.D. Giordano, J.F. Baumhauer, T.L. Morgan, and G.R. Rechtine Cervical spine imaging using standard C-arm fluoroscopy: patient and surgeon exposure to ionizing radiation Spine 33 18 2008 1970 1976
    • (2008) Spine , vol.33 , Issue.18 , pp. 1970-1976
    • Giordano, B.D.1    Baumhauer, J.F.2    Morgan, T.L.3    Rechtine, G.R.4
  • 18
    • 77956413714 scopus 로고    scopus 로고
    • Percutaneous placement of radiopaque markers at the pedicle of interest for preoperative localization of thoracic spine level
    • M.J. Binning, and M.H. Schmidt Percutaneous placement of radiopaque markers at the pedicle of interest for preoperative localization of thoracic spine level Spine 35 19 2010 1821 1825
    • (2010) Spine , vol.35 , Issue.19 , pp. 1821-1825
    • Binning, M.J.1    Schmidt, M.H.2
  • 19
    • 82355194973 scopus 로고    scopus 로고
    • Intra-operative localisation of spinal level using pre-operative CT-guided placement of a flexible hook-wire marker
    • P.M. Sammon, R. Gibson, I. Fouyas, and M.A. Hughes Intra-operative localisation of spinal level using pre-operative CT-guided placement of a flexible hook-wire marker Br J Neurosurg 25 6 2011 778 779
    • (2011) Br J Neurosurg , vol.25 , Issue.6 , pp. 778-779
    • Sammon, P.M.1    Gibson, R.2    Fouyas, I.3    Hughes, M.A.4
  • 21
    • 68849100605 scopus 로고    scopus 로고
    • Cervical spine imaging using mini-C-arm fluoroscopy: Patient and surgeon exposure to direct and scatter radiation
    • B.D. Giordano, J.F. Baumhauer, T.L. Morgan, and G.R. Rechtine 2nd Cervical spine imaging using mini-C-arm fluoroscopy: patient and surgeon exposure to direct and scatter radiation J Spinal Disord Tech 22 6 2009 399 403
    • (2009) J Spinal Disord Tech , vol.22 , Issue.6 , pp. 399-403
    • Giordano, B.D.1    Baumhauer, J.F.2    Morgan, T.L.3    Rechtine II, G.R.4
  • 23
    • 84867213999 scopus 로고    scopus 로고
    • The 'nightmare' of wrong level in spine surgery: A critical appraisal
    • C. Irace, and S. Usai The 'nightmare' of wrong level in spine surgery: a critical appraisal Patient Saf Surg 6 1 2012 14
    • (2012) Patient Saf Surg , vol.6 , Issue.1 , pp. 14
    • Irace, C.1    Usai, S.2
  • 24
    • 17144473657 scopus 로고    scopus 로고
    • The application of ALARA for occupational exposures NCRP Statement No. 8, issued June 8, 1999. National Council on Radiation Protection
    • The application of ALARA for occupational exposures NCRP Statement No. 8, issued June 8, 1999. National Council on Radiation Protection Health Phys 78 Suppl. 5 2000 S76 S77
    • (2000) Health Phys , vol.78 , Issue.SUPPL. 5
  • 25
    • 34147141336 scopus 로고    scopus 로고
    • Achieving the national quality forum's never events: Prevention of wrong site, wrong procedure, and wrong patient operations
    • DOI 10.1097/01.sla.0000251573.52463.d2, PII 0000065820070400000006
    • R.K. Michaels, M.A. Makary, Y. Dahab, F.J. Frassica, E. Heitmiller, L.C. Rowen, R. Crotreau, H. Brem, and P.J. Pronovost Achieving the National Quality Forum's "Never Events": prevention of wrong site, wrong procedure, and wrong patient operations Ann Surg 245 4 2007 526 532 (Pubitemid 46555654)
    • (2007) Annals of Surgery , vol.245 , Issue.4 , pp. 526-532
    • Michaels, R.K.1    Makary, M.A.2    Dahab, Y.3    Frassica, F.J.4    Heitmiller, E.5    Rowen, L.C.6    Crotreau, R.7    Brem, H.8    Pronovost, P.J.9
  • 26
    • 80955135100 scopus 로고    scopus 로고
    • Accuracy of image-guided pedicle screw placement using intraoperative computed tomography-based navigation with automated referencing. Part II: Thoracolumbar spine
    • K.M. Scheufler, J. Franke, A. Eckardt, and H. Dohmen Accuracy of image-guided pedicle screw placement using intraoperative computed tomography-based navigation with automated referencing. Part II: thoracolumbar spine Neurosurgery 69 6 2011 1307 1316
    • (2011) Neurosurgery , vol.69 , Issue.6 , pp. 1307-1316
    • Scheufler, K.M.1    Franke, J.2    Eckardt, A.3    Dohmen, H.4
  • 28
    • 78649648086 scopus 로고    scopus 로고
    • Lumbosacral transitional vertebrae: Classification, imaging findings, and clinical relevance
    • G.P. Konin, and D.M. Walz Lumbosacral transitional vertebrae: classification, imaging findings, and clinical relevance Am J Neuroradiol 31 10 2010 1778 1786
    • (2010) Am J Neuroradiol , vol.31 , Issue.10 , pp. 1778-1786
    • Konin, G.P.1    Walz, D.M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.